Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anal Methods ; 16(3): 420-426, 2024 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-38165136

RESUMO

The efficient extraction of phthalic acid esters (PAEs) is challenging due to their extremely low concentration, complicated matrices and hydrophilicity. Herein, hollow microspheres, as an ideal coating, possess significant potential for solid-phase microextraction (SPME) due to their fascinating properties. In this study, multiwalled carbon nanotube hollow microspheres (MWCNT-HMs) were utilized as a fiber coating for the SPME of PAEs from tea beverages. MWCNT-HMs were obtained by dissolving the polystyrene (PS) cores with organic solvents. Interestingly, MWCNT-HMs well maintain the morphology of the MWCNTs@PS precursors. The layer-by-layer (LBL) assembly of MWCNTs on PS microsphere templates was achieved through electrostatic interactions. Six PAEs, di-ethyl phthalate (DEP), di-iso-butyl phthalate (DIBP), di-n-butyl phthalate (DBP), benzyl butyl phthalate (BBP), di-2-ethylhexyl phthalate (DEHP) and di-n-octyl phthalate (DOP), were selected as target analytes for assessing the efficiency of the coating for SPME. The stirring rate, sample solution pH and extraction time were optimized by using the Box-Behnken design. Under optimal working conditions, the proposed MWCNT-HMs/SPME was coupled with gas chromatography-tandem mass spectrometry (GC-MS/MS) to achieve high enrichment factors (118-2137), wide linearity (0.0004-10 µg L-1), low limits of detection (0.00011-0.0026 µg L-1) and acceptable recovery (80.2-108.5%) for the detection of PAEs. Therefore, the MWCNT-HM coated fibers are promising alternatives in the SPME method for the sensitive detection of PAEs at trace levels in tea beverages.


Assuntos
Nanotubos de Carbono , Ácidos Ftálicos , Microextração em Fase Sólida/métodos , Microesferas , Cromatografia Gasosa-Espectrometria de Massas/métodos , Espectrometria de Massas em Tandem , Ácidos Ftálicos/análise , Ácidos Ftálicos/química , Bebidas/análise , Chá
2.
Se Pu ; 41(5): 409-416, 2023 May 08.
Artigo em Chinês | MEDLINE | ID: mdl-37087606

RESUMO

In this work, carbon nanotubes (CNTs) on silica rod (SiO2) composite materials were prepared to extract six perfluorinated compounds (PFCs) in real environmental water samples by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The as-synthesized sorbents, hereafter referred to as CNT@SiO2, were employed for dispersive solid-phase extraction (d-SPE). Perfluoroheptanoic acid (PFHpA), perfluorohexane sulfonate (PFHxS), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), perfluorooctane sulfonate (PFOS), and perfluorodecanoic acid (PFDA) were selected as target analytes. The main extraction parameters were systematically optimized using the single-factor optimization method. The optimum adsorption parameters were as follows: adsorption time of 30 min, sorbent amount of 10 mg, pH 6 and NaCl concentration of 1.7 mol/L for sample solution, and 4 mL acetone as desorption solvent, desorption for 4 min. LC-triple quadrupole MS was conducted to quantify the selected PFCs in water samples. The mobile phase was 5 mmol/L ammonium acetate and methanol, the flow rate was set to 0.4 mL/min, the column temperature was set to 40 ℃, and the injection volume was 5.0 µL. The chromatographic separation system was equipped with a Kinetex C18 column (100 mm×2.1 mm, 1.7 µm). The mass spectrometer was operated with negative electrospray ionization in multi-reaction monitoring mode. CNT@SiO2 was prepared in five batches and used as the d-SPE sorbent, and the relative standard deviations (RSDs) of the PFC recoveries among these five batches ranged from 4.9% to 9.3%. The reusability of the CNT@SiO2 sorbent was assessed. After eight d-SPE cycles using the same sorbent, the RSDs of the PFC recoveries were 3.7%-8.2%. These results indicated that the sorbent had good stability and reusability for d-SPE. Excellent results were achieved under optimal extraction conditions. The method validation results indicated that the linear ranges were 0.4-1000 ng/L for PFNA, PFOS, and PFDA, 0.9-1000 ng/L for PFHpA, 0.7-1000 ng/L for PFHxS, and 0.6-1000 ng/L for PFOA. The correlation coefficients were 0.973-0.997. The limit of detection (LOD) and limit of quantification of the method were 0.10-0.26 ng/L and 0.33-0.87 ng/L, respectively. At 20 ng/L, the RSDs of the intra- and inter-day precisions were 2.73%-7.75% and 3.38%-8.21%, respectively. At 100 ng/L, the RSDs of the intra- and inter-day precisions were 2.95%-8.46% and 4.16%-9.14%, respectively. Finally, at 500 ng/L, the RSDs of the intra- and inter-day precisions were 2.51%-7.48% and 3.59%-9.63%, respectively. The developed method was applied to analyze six PFCs in tap water, barreled drinking water, and river water samples. PFOA and PFOS were determined in tap water at mass concentrations of 5.6 and 8.7 ng/L, respectively. No PFCs were found in barreled drinking water and river water. Satisfactory recoveries of 72.1%-109.6% at low, middle, and high spiking levels were also obtained. In conclusion, the d-SPE-LC-MS/MS method based on CNT@SiO2 composite sorbents is accurate and sensitive. The results of this study demonstrate that CNT@SiO2 is a good choice for the rapid and effective determination of PFCs from water samples. Further exploration of the use of CNT@SiO2 sorbents for the extraction and determination of trace organic pollutions in environmental samples is in progress.

3.
PeerJ ; 10: e12944, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35291486

RESUMO

Background: Immediate early response 3 (IER3) is correlated to the prognosis of several cancers, but the precise mechanisms underlying the regulation by IER3 of the occurrence and development of hepatocellular carcinoma (HCC) remain unknown. Methods: The expression level of IER3 was examined by using in-house immunohistochemistry (IHC), public gene chip, and public RNA-sequencing (RNA-seq). The standardized mean difference (SMD) was calculated to compare the expression levels of IER3 between HCC patients and controls. The summary receiver operating characteristics (sROC) was plotted to comprehensively understand the discriminatory capability of IER3 between HCC and non-HCC group. The Kaplan-Meier curves and the combined hazard ratios (HRs) were used to determine the prognostic value of IER3 in HCC. Moreover, differentially expressed genes (DEGs) and co-expression genes (CEGs) were used to explored the molecular mechanisms of IER3 underlying HCC. hTFtarget was used to predict the transcription factors (TFs) of IER3. The binding site of TFs and the IER3 promoter region was forecasted using the JASPAR website. The relevant ChIP-seq data were used to determine whether TF peaks were present in the IER3 transcription initiation. Results: A significantly increased expression of IER3 protein was found in HCC tissue relative to non-HCC tissue as detected by IHC (p < 0.001). Compared to 1,263 cases of non-HCC tissues, IER3 in 1483 cases of HCC tissues was upregulated (SMD = 0.42, 95% confidence interval [CI] [0.09-0.76]). The sROC showed that IER3 had a certain ability at differentiating HCC tissues (area under the curve (AUC) = 0.65, 95% CI [0.61-0.69]). Comprehensive analysis of the effect of IER3 on the prognosis of patients with HCC demonstrated that higher IER3 expression was associated with poor prognosis in HCC (HRs = 1.30, 95% CI [1.03-1.64]). Pathway enrichment analysis revealed that IER3-related genes were mostly enriched in the PI3K-Akt signaling pathway, cancer-related signaling pathways, the p53 signaling pathway, and other signaling pathways. Regulatory factor X5 (RFX5) was identified as a possible regulator of IER3-related TF. Conclusion: IER3 may be a potential prognostic marker for HCC. The molecular mechanisms of IER3 in HCC warrant further study.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/genética , Neoplasias Hepáticas/genética , Fosfatidilinositol 3-Quinases , Prognóstico , Modelos de Riscos Proporcionais , Proteínas de Membrana , Proteínas Reguladoras de Apoptose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA