Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 112(5): 050801, 2014 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-24580583

RESUMO

We report a high-accuracy direct measurement of the blackbody radiation shift of the 133Cs ground-state hyperfine transition. This frequency shift is one of the largest systematic frequency biases encountered in realizing the current definition of the International System of Units (SI) second. Uncertainty in the blackbody radiation frequency shift correction has led to its being the focus of intense theoretical effort by a variety of research groups. Our experimental measurement of the shift used three primary frequency standards operating at different temperatures. We achieved an uncertainty a factor of five smaller than the previous best direct measurement. These results tend to validate the claimed accuracy of the recently calculated values.

2.
Phys Rev Lett ; 103(6): 063001, 2009 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-19792559

RESUMO

We experimentally investigate an optical clock based on ;{171}Yb (I = 1/2) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of 3.4 x 10;{-16}, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.

3.
Phys Rev Lett ; 98(7): 070801, 2007 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-17359009

RESUMO

We report tests of local position invariance and the variation of fundamental constants from measurements of the frequency ratio of the 282-nm 199Hg+ optical clock transition to the ground state hyperfine splitting in 133Cs. Analysis of the frequency ratio of the two clocks, extending over 6 yr at NIST, is used to place a limit on its fractional variation of <5.8x10(-6) per change in normalized solar gravitational potential. The same frequency ratio is also used to obtain 20-fold improvement over previous limits on the fractional variation of the fine structure constant of |alpha/alpha|<1.3x10(-16) yr-1, assuming invariance of other fundamental constants. Comparisons of our results with those previously reported for the absolute optical frequency measurements in H and 171Yb+ vs other 133Cs standards yield a coupled constraint of -1.5x10(-15)

4.
Phys Rev Lett ; 98(7): 070802, 2007 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-17359010

RESUMO

We report the most sensitive tests to date of the assumption of local position invariance (LPI) underlying general relativity, based on a 7 yr comparison of cesium and hydrogen atomic clocks (frequency standards). The latest results place an upper limit that is over 20 times smaller than the previous most sensitive tests; this is consistent with the null shift predicted by LPI. The result is based on precise comparisons of frequencies of four hydrogen masers maintained by NIST, with four independent Cs fountain clocks--one at NIST and three in Europe--as the Sun's gravitational potential at Earth's surface varies due to Earth's orbital eccentricity.

5.
Phys Rev Lett ; 97(2): 020801, 2006 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-16907426

RESUMO

For the past 50 years, atomic standards based on the frequency of the cesium ground-state hyperfine transition have been the most accurate time pieces in the world. We now report a comparison between the cesium fountain standard NIST-F1, which has been evaluated with an inaccuracy of about 4 x 10(-16), and an optical frequency standard based on an ultraviolet transition in a single, laser-cooled mercury ion for which the fractional systematic frequency uncertainty was below 7.2 x 10(-17). The absolute frequency of the transition was measured versus cesium to be 1,064,721,609,899,144.94 (97) Hz, with a statistically limited total fractional uncertainty of 9.1 x 10(-16) the most accurate absolute measurement of an optical frequency to date.

6.
Artigo em Inglês | MEDLINE | ID: mdl-15244277

RESUMO

We have measured a previously unobserved systematic frequency shift in our cesium-fountain frequency standard, NIST-F1. This shift, predicted theoretically previously, mimics the well-known end-to-end phase shift in atomic beam standards when synchronous thermal transients are present. Detuning the microwave cavity several megahertz from resonance reduces this effect to the deltaf/f = 1o(-16) level.

7.
Phys Rev Lett ; 90(15): 150802, 2003 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-12732024

RESUMO

Over a two-year duration, we have compared the frequency of the 199Hg+ 5d(10)6s (2)S(1/2)(F=0)<-->5d(9)6s(2) (2)D(5/2)(F=2) electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral 133Cs. These measurements show that any fractional time variation of the ratio nu(Cs)/nu(Hg) between the two frequencies is smaller than +/-7 x 10(-15) yr(-1) (1sigma uncertainty). According to recent atomic structure calculations, this sets an upper limit to a possible fractional time variation of g(Cs)(m(e)/m(p))alpha(6.0) at the same level.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA