Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
J Arthroplasty ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38759818

RESUMO

BACKGROUND: Variations in defining poor response to total knee arthroplasty (TKA) impede comparisons of response after TKA over time and across hospitals. This study aimed to compare the prevalence, overlap, and discriminative accuracy of 15 definitions of poor response after TKA using two databases. METHODS: Data of patients one year after primary TKA from the Dutch Arthroplasty Register (LROI) (n = 12,275) and the Osteoarthritis Initiative (OAI) database (n = 204) were used to examine the prevalence, overlap (estimated by Cohen's kappa), and discriminative accuracy (sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and Youden index) of 15 different definitions of poor response after TKA. In the absence of a gold standard for measuring poor response to TKA, the numeric rating scale (NRS) satisfaction (≤ 6 'poor responder') and the global assessment of knee impact (dichotomized: ≥ 4 'poor responder') were used as anchors for assessing discriminative accuracy for the LROI and OAI dataset, respectively. These anchors were chosen based on a prior qualitative study that identified (dis)satisfaction as a central theme of poor responses to TKA by patients and knee specialists. RESULTS: The median (25th to 75th percentile) prevalence of poor responders in the examined definitions was 18.5% (14.0 to 25.5%), and the median Cohen's kappa for the overlap between pairs of definitions was 0.41 (0.32 to 0.59). Median (25th to 75th percentile) sensitivity was 0.45 (0.39 to 0.54), specificity was 0.86 (0.82 to 0.94), PPV was 0.45 (0.34 to 0.62), NPV was 0.89 (0.87 to 0.89), and the Youden index was 0.36 (0.20 to 0.43). CONCLUSION: This found a lack of overlap between different definitions of poor response to TKA. None of the examined definitions adequately classified poor responders to TKA. In contrast, the absence of a poor response could be classified with confidence.

2.
J Bone Jt Infect ; 9(1): 9-16, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38600999

RESUMO

Automated custom-made multiplex PCR techniques (mPCR) have become commercially available and are designed for intra-operative screening of concurrent periprosthetic joint infections (PJIs). The purpose of this study was to evaluate the value of a positive mPCR test in presumed aseptic revision total hip (THA) and knee (TKA) arthroplasties after a 1-year follow-up. In an earlier study, such an automated mPCR technique (Unyvero ITI G2; Curetis, Holzgerlingen, Germany) was tested on intra-operatively obtained synovial fluid in 200 patients with a presumed aseptic TKA or THA revision. At the time of revision, no therapeutic consequences were attached to a positive test result since treating personnel were blinded for the test results. We retrospectively reviewed the outcome of cases with respect to the occurrence of PJIs using the European Bone and Joint Infection Society (EBJIS) criteria during a 1-year follow-up postoperatively. A total of 10 out of 200 patients had a positive mPCR test result at the time of revision. Of these 10 cases, none encountered outcome parameters fulfilling the criteria to diagnose PJIs in the first year after surgery, and one required re-revision surgery for reasons other than infection. Of the other 190 negative mPCR cases, none developed a PJI. A positive mPCR test at the time of presumed aseptic revision surgery did not correspond with intra-operatively obtained tissue cultures, and none of the encountered positive mPCR tests had developed a PJI at the 1-year follow-up. We recommend careful evaluation and monitoring of modern diagnostic tests before widespread use.

3.
Knee Surg Sports Traumatol Arthrosc ; 32(2): 461-472, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38284904

RESUMO

PURPOSE: The purpose of this study was to evaluate a multidisciplinary intervention developed for patients with debilitating chronic pain after total knee arthroplasty (TKA) unresponsive to existing treatment options. METHODS: A treatment-based prospective cohort study was caried out in 30 TKA patients with debilitating chronic pain at least 1 year after TKA. The treatment was a multidisciplinary intervention. Main inclusion criteria: no indication for surgery. Primary outcome was function measured by KOOS-PS, OKS, OKS-APQ and WORQ. Secondary outcome measures were pain, fear of movement, self-efficacy, quality of life (QoL), health care and pain medication use, work rehabilitation and patient satisfaction. The assessments took place pre- and directly posttreatment, at 1, 3 and 12 months follow-up. The clinical relevance was assessed by predefined minimal important clinical change (MCIC). RESULTS: At baseline patients were on average 64.7 (±7.9) years old, 67% were female, and they had knee pain for 42 (10-360) months. The results at 12-month follow-up: first, a significant improvement was shown in function, pain, fear of movement, self-efficacy and QoL. Second, in 38.5%-69.2% of patients clinical relevant improvement was shown for functional outcome, 31% for pain, and 50% for self-efficacy. Third, 42% of patients reported 'no healthcare use in the past three months'. CONCLUSION: One year after a multidisciplinary treatment a clinically relevant improvement was shown in terms of function, pain, self-efficacy and QoL. It seems to be a promising treatment option in this difficult-to-treat patient group with debilitating chronic pain after TKA. Future research should examine the effect of the treatment in a larger study population, considering a control group, and focusing on the working population and evaluating cost-efficacy. LEVEL OF EVIDENCE: Level II.


Assuntos
Artroplastia do Joelho , Dor Crônica , Osteoartrite do Joelho , Humanos , Feminino , Masculino , Artroplastia do Joelho/efeitos adversos , Qualidade de Vida , Osteoartrite do Joelho/cirurgia , Dor Crônica/etiologia , Dor Crônica/terapia , Estudos Prospectivos , Recuperação de Função Fisiológica , Articulação do Joelho/cirurgia , Resultado do Tratamento , Medidas de Resultados Relatados pelo Paciente
4.
J Arthroplasty ; 39(3): 651-657.e1, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37611678

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) can have a number of adverse consequences for patients that might contribute to a poor outcome. This study aimed to prioritize these consequences, from the perspective of patients and knee specialists. METHODS: There were 95 TKA patients and 63 knee specialists who prioritized a set of 29 adverse consequences, based on a previous qualitative study, using a Maximum Difference Scaling method. A hierarchical Bayesian analysis was used to calculate relative importance scores. Differences and agreements between patients versus knee specialists and satisfied versus dissatisfied patients were analyzed using Mann-Whitney-U tests and Kendall's coefficients of concordance. RESULTS: There were 4 out of 5 items in the top-5 of both patients and knee specialists that were similar, however, the ranking was different. The highest-ranked consequence for patients was: "Inability to do normal activities such as walking, cycling, swimming and heavy household chores", while knee specialists ranked: "No improvement in pain during the day" as the highest. "No improvement in walking" was in the patients' top-5, but was not ranked in the top-5 of knee specialists. For satisfied and dissatisfied patients, the top-5 of consequences was similar. CONCLUSION: Comparable perspectives were found for patients versus knee specialists and satisfied versus dissatisfied patients on the importance of adverse consequences after TKA. However, when looking in more detail, differences in ranking of specific subitems suggest that patients place slightly more importance on the inability to perform valued activities, while knee specialists prioritize lack of pain relief to a higher degree.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Teorema de Bayes , Satisfação do Paciente , Osteoartrite do Joelho/cirurgia , Articulação do Joelho/cirurgia , Dor/cirurgia , Resultado do Tratamento
5.
Rheumatol Adv Pract ; 8(1): rkad111, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38152392

RESUMO

Objectives: A successful outcome according to the knee specialist is not a guarantee for treatment success as perceived by patients. In this study, we aimed to explore outcome expectations and experiences of patients with OA before and after total knee arthroplasty (TKA) surgery and knee specialists that might contribute to the negative appraisal of its effect, and differences in views between patients and knee specialists. Methods: Semi-structured interviews were held in Belgium and the Netherlands. Twenty-five patients (2 without indications for TKA, 11 on the waiting list for TKA and 12 postoperative TKA) and 15 knee specialists (9 orthopaedic surgeons, 1 physician assistant, 1 nurse practitioner and 4 physiotherapists) were interviewed. Conversations were audio recorded, transcribed verbatim, and analysed using thematic analysis following the grounded theory approach. Separate analyses were conducted for patients and knee specialists. Results: Patients were focused on the arduous process of getting used to the prosthesis, lingering pain, awareness of the artificial knee and limitations they experience during valued and daily activities, whereas knee specialists put emphasis on surgical failure, unexplained pain, limited walking ability and impairments that limit the physical functioning of patients. Conclusion: This study provides a comprehensive overview of potential adverse consequences from the perspective of both patients and knee specialists. Improving patients' awareness and expectations of adaptation to the knee prosthesis needs to be considered.

6.
J Arthroplasty ; 38(12): 2680-2684.e1, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37286056

RESUMO

BACKGROUND: Revision knee arthroplasty (R-KA) is rising globally. Technical difficulty of R-KA varies from liner exchange to full revision. Centralization has been shown to reduce mortality and morbidity rates. The present study aimed to evaluate the association between hospital R-KA volume and overall second revision rate, as well as revision rate for different types of revision. METHODS: The R -KAs between 2010 and 2020 with available data on the primary KA in the Dutch Orthopaedic Arthroplasty Register were included. Minor revisions were excluded. Implant data and anonymous patient characteristics were obtained from the Dutch Orthopaedic Arthroplasty Register. Survival analyses and competing risk analysis were performed per volume category (≤12, 13 to 24, or ≥25 cases/year) at 1, 3, and 5 years following R-KA. There were 8,072 R-KA cases available. Median follow-up was 3.7 years (range 0 to 13.7 years). There were a total of 1,460 second revisions (18.1%) at the end of follow-up. RESULTS: There were no statistically significant differences between second revision rates of the three volume groups. Adjusted hazard ratio for second revision were 0.97 (Confidence Interval (CI) 0.86 to 1.11) for hospitals with 13 to 24 cases/year and 0.94 (CI 0.83 to 1.07) with ≥25 cases/year compared to low volume (≤12 cases/year). Type of revision did not influence second revision rate. CONCLUSION: Second revision rate of R-KA does not seem to be dependent on hospital volume or type of revision in the Netherlands. LEVEL OF EVIDENCE: Level IV, Observational registry study.


Assuntos
Artroplastia do Joelho , Ortopedia , Humanos , Hospitais , Sistema de Registros , Reoperação , Resultado do Tratamento
7.
Acta Orthop ; 94: 185-190, 2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-37096567

RESUMO

BACKGROUND AND PURPOSE: Rotating hinged knee implants are highly constrained prostheses used in cases in which adequate stability is mandatory. Due to their constraint nature, multidirectional stresses are directed through the bone-cement-implant interface, which might affect fixation and survival. The goal of this study was to assess micromotion of a fully cemented rotating hinged implant using radiostereometric analysis (RSA). PATIENTS AND METHODS: 20 patients requiring a fully cemented rotating hinge-type implant were included. RSA images were taken at baseline, 6 weeks, and 3, 6, 12, and 24 months postoperatively. Micromotion of femoral and tibial components referenced to markers in the bone was assessed with model-based RSA software, using implant CAD models. Total translation (TT), total rotation (TR), and maximal total point motion (MTPM) were calculated (median and range). RESULTS: At 2 years, TTfemur was 0.38 mm (0.15-1.5), TRfemur was 0.71° (0.37-2.2), TTtibia was 0.40 mm (0.08-0.66), TRtibia was 0.53° (0.30-2.4), MTPMfemur was 0.87 mm (0.54-2.8), and MTPMtibia was 0.66 mm (0.29-1.6). Femoral components showed more outliers (> 1 mm, > 1°) compared with tibial components. CONCLUSION: Fixation of this fully cemented rotating hinge-type revision implant seems adequate in the first 2 years after surgery. Femoral components showed more outliers, in contrast to previous RSA studies on condylar revision total knee implants.


Assuntos
Prótese do Joelho , Osteoartrite do Joelho , Humanos , Seguimentos , Análise Radioestereométrica/métodos , Osteoartrite do Joelho/cirurgia , Desenho de Prótese , Articulação do Joelho/cirurgia , Resultado do Tratamento , Falha de Prótese
9.
Bone Joint J ; 105-B(1): 35-46, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36587259

RESUMO

AIMS: The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA). METHODS: A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively. Femorotibial contact point (CP) locations were determined at every flexion angle and compared between the groups. RSA images were taken at baseline, six weeks, three, six, 12, and 24 months postoperatively. Clinical and functional outcomes were compared postoperatively for two years. RESULTS: The BCR-TKA demonstrated a kinematic pattern comparable to the natural knee's screw-home mechanism in the step-up task. In the lunge task, the medial CP of the BCR-TKA was more anterior in the early flexion phase, while laterally the CP was more posterior during the entire movement cycle. The BCR-TKA group showed higher tibial migration. No differences were found for the clinical and functional outcomes. CONCLUSION: The BCR-TKA shows a different kinematic pattern in early flexion/late extension compared to the CR-TKA. The difference between both implants is mostly visible in the flexion phase in which the anterior cruciate ligament is effective; however, both designs fail to fully replicate the motion of a natural knee. The higher migration of the BCR-TKA was concerning and highlights the importance of longer follow-up.Cite this article: Bone Joint J 2023;105-B(1):35-46.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Ligamento Cruzado Posterior , Humanos , Artroplastia do Joelho/métodos , Análise Radioestereométrica , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Ligamento Cruzado Anterior/cirurgia , Fluoroscopia , Fenômenos Biomecânicos , Amplitude de Movimento Articular , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Ligamento Cruzado Posterior/diagnóstico por imagem , Ligamento Cruzado Posterior/cirurgia
10.
Bone Joint J ; 104-B(7): 875-883, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35775183

RESUMO

AIMS: Both the femoral and tibial component are usually cemented at revision total knee arthroplasty (rTKA), while stems can be added with either cemented or press-fit (hybrid) fixation. The aim of this study was to compare the long-term stability of rTKA with cemented and press-fitted stems, using radiostereometric analysis (RSA). METHODS: This is a follow-up of a randomized controlled trial, initially involving 32 patients, of whom 19 (nine cemented, ten hybrid) were available for follow-up ten years postoperatively, when further RSA measurements were made. Micromotion of the femoral and tibial components was assessed using model-based RSA software (RSAcore). The clinical outcome was evaluated using the Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score (KOOS), and visual analogue scale (pain and satisfaction). RESULTS: The median total femoral translation and rotation at ten years were 0.39 mm (interquartile range (IQR) 0.20 to 0.54) and 0.59° (IQR 0.46° to 0.73°) for the cemented group and 0.70 mm (IQR 0.15 to 0.77) and 0.78° (IQR 0.47° to 1.43°) for the hybrid group. For the tibial components this was 0.38 mm (IQR 0.33 to 0.85) and 0.98° (IQR 0.38° to 1.34°) for the cemented group and 0.42 mm (IQR 0.30 to 0.52) and 0.72° (IQR 0.62° to 0.82°) for the hybrid group. None of these values were significantly different between the two groups and there were no significant differences between the clinical scores in the two groups at this time. There was only one re-revision, in the hybrid group, for infection and not for aseptic loosening. CONCLUSION: These results show good long-term fixation with no difference in micromotion and clinical outcome between fully cemented and hybrid fixation in rTKA, which builds on earlier short- to mid-term results. The patients all had type I or II osseous defects, which may in part explain the good results. Cite this article: Bone Joint J 2022;104-B(7):875-883.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/métodos , Cimentos Ósseos , Humanos , Osteoartrite do Joelho/cirurgia , Desenho de Prótese , Falha de Prótese , Reoperação , Resultado do Tratamento
11.
Knee Surg Sports Traumatol Arthrosc ; 30(4): 1273-1281, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33860338

RESUMO

PURPOSE: The present study assessed the effect of insert articular surface geometry (anatomical versus conventional insert design) on anteroposterior (AP) translation and varus-valgus (VV) laxity in balanced posterior cruciate ligament (PCL) retaining total knee arthroplasty (TKA). Secondly, we evaluated if the AP translation and VV laxity in the reconstructed knee resembled the stability of the native knee. METHODS: Nine fresh-frozen full-leg cadaver specimens were used in this study. After testing the native knee, anatomical components of a PCL-retaining implant were implanted. The knee joints were subjected to anteriorly and posteriorly directed forces (at 20° and 90° flexion) and varus-valgus stresses (at 20°, 45° and 90° flexion) in both non-weightbearing and weightbearing situations in a knee kinematics simulator. Measurements were performed in the native knee, TKA with anatomical insert geometry (3° built-in varus, medial concave, lateral convex), and TKA with symmetrical insert geometry. RESULTS: In weightbearing conditions, anterior translations ranged between 2.6 and 3.9 mm at 20° flexion and were < 1 mm at 90° flexion. Posterior translation at 20° flexion was 2.7 mm for the native knee versus 4.0 mm (p = 0.047) and 7.0 mm (p = 0.02) for the symmetrical insert and the anatomical insert, respectively. Posterior translation at 90° flexion was < 1.1 mm and not significantly different between the native knee and insert types. In non-weightbearing conditions, the anterior translation at 20° flexion was 5.9 mm for the symmetrical and 4.6 mm for the anatomical insert (n.s.), compared with 3.0 mm for the native knee (p = 0.02). The anterior translation at 90° flexion was significantly higher for the reconstructed knees (anatomical insert 7.0 mm; symmetrical insert 9.2 mm), compared with 1.6 mm for the native knee (both p = 0.02). Varus-valgus laxity at different flexion angles was independent of insert geometry. A valgus force in weightbearing conditions led to significantly more medial laxity (1°-3° opening) in the native knee at 45° and 90° flexion compared with the reconstructed knee for all flexion angles. CONCLUSIONS: Insert geometry seems to have a limited effect with respect to AP translation and VV laxity, in the well-balanced PCL-retaining TKA with an anatomical femoral component. Secondly, AP translation and VV laxity in the reconstructed knee approximated the laxity of the native knee.


Assuntos
Artroplastia do Joelho , Instabilidade Articular , Prótese do Joelho , Ligamento Cruzado Posterior , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Cadáver , Humanos , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Ligamento Cruzado Posterior/cirurgia , Amplitude de Movimento Articular
12.
J Knee Surg ; 35(10): 1153-1158, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33485277

RESUMO

Hinged prostheses have been increasingly utilized in complex and revision total knee arthroplasty (TKA) cases requiring additional mechanical support and global stability. However, there is limited data detailing the outcomes of modern hinge designs in these procedures. The aim of this study is to report a minimum 2-year functional outcomes and survivorship of a novel-guided motion-hinged knee TKA system. A multicenter, retrospective cohort study was conducted on consecutive TKA patients between March 2013 and August 2017 with a novel-guided motion-hinged knee system. Demographics, change in range of motion (ΔROM), quality metrics, and implant survivorship were collected with a minimum of 2-year follow-up. Implant survival was analyzed by using the Kaplan-Meier method. Overall, 147 hinged knee cases (18 complex primaries and 129 revisions) were identified with an average follow-up duration of 3.8 ± 1.2 years. Patients presented with an average of 2.4 ± 1.6 prior knee surgeries, and 51 (34.7%) had a history of knee infections. The ROM improved postoperatively: Δ extension = 2 ± 1 degrees, Δflexion = 7 ± 3 degrees, Δtotal ROM = 9 ± 4 degrees. Kaplan-Meier survivorship analysis for implant revision at 2- and 5-year follow-up showed a survival rate of 100 and 98.5% (95% confidence interval: 94.3-99.6%), respectively, with one patient undergoing two-stage revision for infection and another undergoing femoral revision for aseptic loosening. Survivorship for aseptic all-cause reoperation at 2- and 5-year follow-up was 93.2% (87.7-96.3%) and 88.2% (80.0-93.2%), respectively. Fourteen patients underwent aseptic reoperation (patellar complications: n = 7 [4.8%]; instability: n = 5 [3.4%]; tuberosity fixation: n = 1 [0.7%]; extensor mechanism failure: n = 1 [1.1%]). Survivorship for all-cause reoperation at 2- and 5-year follow-up were 85% (78.2-90.0%) and 77.7% (68.8-84.3%), respectively. Fifteen patients underwent reoperation for infection (DAIR: n = 14 (9.5%); two-stage revision: n = 1 [0.7%]). Despite some reoperations, this guided-motion hinged-knee TKA system demonstrates excellent survivorship for component revision compared to other modern hinged knee implants reported in the literature. Patients also displayed an improvement in knee ROM at their latest follow-up.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/efeitos adversos , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Desenho de Prótese , Falha de Prótese , Reoperação/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
13.
J Arthroplasty ; 37(3): 482-487, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34864066

RESUMO

BACKGROUND: Clinical observations revealed higher rates of aseptic loosening for hybrid fixated rotating hinge knee implants compared to fully cemented ones. We hypothesize that the use of a fully cemented fixation technique had a higher survival rate for aseptic loosening compared to a hybrid fixation technique in a rotating hinge knee implant. METHODS: All procedures of patients who were treated with the RT-PLUS rotating hinge knee implant (Smith & Nephew, Memphis, TN) between 2010 and 2018 were included. Primary outcome was revision for aseptic loosening. Kaplan-Meier survivorship and Cox proportional hazard regression analysis were performed to calculate survival rates and hazard ratios. RESULTS: A total of 275 hinge knee implants were placed in 269 patients (60 primary procedures, 215 revisions). Median follow-up was 7.3 ± 3.9 years. In total, 24 components (16 hybrid femur, 2 fully cemented femur, 6 hybrid tibia; all revision procedures) in 19 patients were revised for aseptic loosening. Kaplan-Meier survivorship analysis showed superior survival rates of fully cemented components (femur 97.1%; tibia 100%) compared to hybrid fixated components (femur 89.5%; tibia 95.9%) at the 10-year follow-up. Multivariate Cox hazard analysis showed a significantly higher risk of aseptic loosening for hybrid fixated components, a prior stemmed component and the femoral component. CONCLUSION: Fully cemented fixation showed superior survival rates for aseptic loosening compared to hybrid fixation in a single design rotating hinge knee implant. A prior stemmed component appears to be a risk factor for aseptic loosening and the femoral component seems to be more prone to loosening.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/efeitos adversos , Fêmur/cirurgia , Humanos , Prótese do Joelho/efeitos adversos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
14.
BMC Musculoskelet Disord ; 22(1): 700, 2021 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-34404359

RESUMO

BACKGROUND: Patients undergoing total knee arthroplasty (TKA) tend to be younger and tend to receive TKA at an earlier stage compared to 20 years ago. The Oxford Knee Score - Activity and Participation (OKS-APQ) questionnaire evaluates higher levels of activity and participation, reflecting activity patterns of younger or more active people. The purpose of this study was to translate the OKS-APQ questionnaire into Dutch, and to evaluate its measurement properties in pre- and postoperative TKA patients. METHODS: The OKS-APQ was translated and adapted according to the forward-backward translation multi step approach and tested for clinimetric quality. Floor and ceiling effects, structural validity, construct validity, internal consistency and test-retest reliability were evaluated using COSMIN quality criteria. The OKS-APQ, the Oxford Knee Score (OKS), the Short Form-36 (SF-36), a Visual Analogue Scale (VAS) for pain and the Forgotten Joint Score (FJS) were assessed in 131 patients (72 preoperative and 59 postoperative TKA patients), and the OKS-APQ was administered twice in 50 patients (12 preoperative and 38 postoperative TKA patients), after an interval of minimal 2 weeks. RESULTS: Floor effects were observed in preoperative patients. Confirmatory factor analyses (CFA) indicated a good fit of a 1-factor model by the following indices: (Comparative Fit Index (CFI): 0.97, Tucker-Lewis Index (TLI): 0.96 and Standardized Root Mean Square Residual (SRMR): 0.03). Construct validity was supported as > 75% of the hypotheses were confirmed. Internal consistency (Cronbach α's from 0.81 to 0.95) was good in the pooled and separate pre- and postoperative samples and test-retest reliability (Intraclass Correlation Coefficients (ICCs) from 0.63 - 0.85) were good in postoperative patients and moderate in preoperative patients. The standard Error of Measurements (SEMs) ranged from 8.5 - 12.2 and the Smallest Detectable Changes in individuals (SDCind) ranged from 23.5 - 34.0 (on a scale from 0 to 100). CONCLUSIONS: Preliminary findings suggest that the Dutch version of the OKS-APQ is reliable and valid for a Dutch postoperative TKA patient sample. However, in a preoperative TKA sample, the OKS-APQ seems less suitable, because of floor effects and lower test-retest reliability. The Dutch version of the OKS-APQ can be used alongside the OKS to discriminate among levels of activity and participation in postoperative patients.


Assuntos
Comparação Transcultural , Osteoartrite do Joelho , Humanos , Osteoartrite do Joelho/diagnóstico , Osteoartrite do Joelho/cirurgia , Psicometria , Reprodutibilidade dos Testes , Inquéritos e Questionários , Traduções
15.
Eur J Clin Microbiol Infect Dis ; 40(6): 1283-1290, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33479882

RESUMO

Ruling out an infection in one-stage knee and hip revisions for presumed aseptic failure by conventional tissue cultures takes up to 14 days. Multiplex polymerase chain reaction (mPCR) is a quick test (4-5 h) for detecting pathogens. The purpose of this study was to evaluate the diagnostic accuracy of an automated mPCR of synovial fluid obtained intraoperatively in unsuspected knee and hip revisions. A prospective study was conducted with 200 patients undergoing a one-stage knee or hip revision. Synovial fluid was analyzed with the mPCR Unyvero implant and tissue infection G2 cartridge (U-ITI G2) system and compared to intraoperative tissue cultures. The primary outcome measure was the diagnostic accuracy, including sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), of the mPCR U-ITI G2 system compared to conventional cultures. In the knee revision group, there were no patients with a positive mPCR in combination with positive cultures. This resulted in a non-calculable sensitivity and PPV. The specificity and NPV in the knee revision group of the mPCR compared to tissue cultures was 96.8% and 96.8%, respectively. In the hip revision group, the sensitivity, specificity, PPV, and NPV of the mPCR compared to tissue cultures was 36.4%, 96.6%, 57.1%, and 92.5%, respectively. Sixteen mismatches occurred between the mPCR and tissue cultures. The mPCR U-ITI G2 system is a quick and reliable synovium fluid test for ruling out infection in presumed aseptic knee and hip revisions with a high NPV compared with tissue cultures, although some mismatches were observed. Periprosthetic tissue cultures are still advised as back-up for false negative and positive mPCR test results.


Assuntos
Bactérias/isolamento & purificação , Quadril/microbiologia , Joelho/microbiologia , Reação em Cadeia da Polimerase Multiplex/métodos , Infecções Relacionadas à Prótese/microbiologia , Idoso , Artroplastia de Quadril/efeitos adversos , Bactérias/classificação , Bactérias/genética , Bactérias/crescimento & desenvolvimento , Feminino , Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infecções Relacionadas à Prótese/etiologia
16.
Knee ; 28: 97-103, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33321414

RESUMO

BACKGROUND: Instability is an infrequently encountered diagnosis in rotating hinge knee (rHK) implants. With the introduction of a new rHK implant, we encountered multiple patients who complained of instability. This article presents its prevalence while describing our diagnostic and treatment algorithms. METHODS: A retrospective analysis of a cohort of all consecutive patients treated with the Legion™ Hinge Knee System (Smith&Nephew, Memphis, Tennessee) as primary or revision procedure between July 2014 and December 2018 was performed. All patients reporting a sense of instability or having recurrent joint effusion after activity were suspected of experiencing instability. Stress X-rays were performed and brace treatment was started. In patients with insufficient effect of brace treatment, a liner exchange to a thicker liner was performed. Prevalence of instability and the effect of treatment was analysed descriptively. RESULTS: In total, six patients were categorized as patients having instability problems (prevalence 3.5%; male:female ratio 5:1; median age 69.5 years; all revision procedures). Indication for revision to the Legion rHK implant was infection (three), instability (two) and aseptic loosening (one). In two patients, a prior rHK implant was revised. All patients showed tilting beyond the tolerance on stress X-ray examination. Brace treatment was adequate in three patients; in the other three patients a liner exchange was performed, two of which were satisfied. CONCLUSION: Instability is an infrequently encountered diagnosis in rHK implants. The design of the Legion rHK implant seems prone to this problem with a prevalence of 3.5%. If brace treatment is insufficient a liner exchange might be considered.


Assuntos
Artroplastia do Joelho/métodos , Instabilidade Articular/diagnóstico , Articulação do Joelho/cirurgia , Prótese do Joelho , Radiografia/métodos , Idoso , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Reoperação/métodos , Estudos Retrospectivos
17.
BMC Musculoskelet Disord ; 21(1): 378, 2020 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-32534571

RESUMO

BACKGROUND: A significant proportion of patients experiences poor response (i.e. no or little improvement) after total knee arthroplasty (TKA) because of osteoarthritis. It is difficult to quantify the proportion of patients who experiences poor response to TKA, as different definitions of, and perspectives (clinician's and patient's) on poor response are being used. The aim of this study was therefore to review the literature and summarize definitions of poor response to TKA. METHODS: A systematic search was performed to identify and review studies that included dichotomous definitions of poor outcome after primary TKA. The type, amount and combination of domains (e.g. functioning), outcome measures, type of thresholds (absolute/relative, change/cut-off), values and moments of follow-up used in definitions were summarized. RESULTS: A total of 47 different dichotomous definitions of poor response to TKA were extracted from 2163 initially identified studies. Thirty-six definitions incorporated one domain, seven definitions comprised two domains and four definitions comprised three domains. Eight different domains were used in identified definitions: pain, function, physical functioning, quality of life (QoL), patient satisfaction, anxiety, depression and patient global assessment. The absolute cut-off value was the most common type of threshold, with large variety in value and timing of follow-up. CONCLUSIONS: Our inventory review shows that definitions of poor response to TKA are heterogeneous. Our findings stresses the need for an unambiguous definition of poor response to draw conclusions about the prevalence of poor-responders to TKA across hospitals and countries, and to identify patients at risk.


Assuntos
Artroplastia do Joelho/efeitos adversos , Osteoartrite do Joelho/cirurgia , Medidas de Resultados Relatados pelo Paciente , Satisfação do Paciente/estatística & dados numéricos , Artroplastia do Joelho/psicologia , Humanos , Osteoartrite do Joelho/psicologia , Medição da Dor , Qualidade de Vida , Recuperação de Função Fisiológica , Resultado do Tratamento
18.
BMC Med Inform Decis Mak ; 20(1): 92, 2020 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-32414368

RESUMO

BACKGROUND: To evaluate the effect of a stand-alone mobile and web-based educational intervention (eHealth tool) compared to usual preparation of a first orthopedic consultation of patients with hip or knee osteoarthritis (OA) on patients' satisfaction. METHODS: A two-armed randomized controlled trial involving 286 patients with (suspicion of) hip or knee OA, randomly allocated to either receiving an educational eHealth tool to prepare their upcoming consultation (n = 144) or usual care (n = 142). Satisfaction with the consultation on three subscales (range 1-4) of the Consumer Quality Index (CQI - primary outcome) and knowledge (assessed using 22 statements on OA, range 0-22), treatment beliefs (assessed by the Treatment beliefs in OsteoArthritis questionnaire, range 1-5), assessment of patient's involvement in consultation by the surgeon (assessed on a 5-point Likert scale) and patient satisfaction with the outcome of the consultation (numeric rating scale), were assessed. RESULTS: No differences between groups were observed on the 3 subscales of the CQI (group difference (95% CI): communication 0.009 (- 0.10, 0.12), conduct - 0.02 (- 0.12, 0.07) and information provision 0.02 (- 0.18, 0.21)). Between group differences (95% CI) were in favor of the intervention group for knowledge (1.4 (0.6, 2.2)), negative beliefs regarding physical activities (- 0.19 (- 0.37, - 0.002) and pain medication (- 0.30 (- 0.49, - 0.01)). We found no differences on other secondary outcomes. CONCLUSIONS: An educational eHealth tool to prepare a first orthopedic consultation for hip or knee OA does not result in higher patient satisfaction with the consultation, but it does influence cognitions about osteoarthritis. TRIAL REGISTRATION: Dutch Trial Register (trial number NTR6262). Registered 30 January 2017.


Assuntos
Osteoartrite do Quadril , Osteoartrite do Joelho , Telemedicina , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/tratamento farmacológico , Osteoartrite do Joelho/tratamento farmacológico , Pacientes , Encaminhamento e Consulta , Resultado do Tratamento
19.
Arch Orthop Trauma Surg ; 140(10): 1495-1501, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32468168

RESUMO

INTRODUCTION: Physiological motion after total knee arthroplasty (TKA) should result in a large range of motion, which would lead to good clinical outcomes. An adjusted design of a bicruciate-stabilizing TKA was developed to reproduce physiological motion. The aim of this study was to (1) investigate the maximal knee flexion of this knee system, 1 year post-operatively; (2) determine the clinical and functional improvement and compare the outcomes between patients with and without high maximal flexion; and (3) evaluate the adverse events. MATERIALS AND METHODS: In this prospective study, 62 patients with osteoarthritis received a bicruciate-stabilizing TKA. Maximum flexion was measured on a lateral X-ray pre- and post-operatively. Clinical and functional scores and the adverse events were reported up until 2 years after surgery. RESULTS: Pre-operatively, the median (range) maximal flexion was 131.5 (90-153)° and 1 year post-operatively, it was 130 (82-150)°. The results for the clinical scores showed an improvement between pre-operative values and post-operative values. The Kujala score and Knee Osteoarthritis Outcome Score (KOOS) symptoms, sport and quality of life score were better in patients with high maximal flexion (≥ 125°). Ten (serious) adverse device events were reported. CONCLUSIONS: In conclusion, the bicruciate-stabilizing TKA obtained a maximal flexion comparable to the flexion pre-operatively and resulted in good clinical and functional outcomes. Patients with high flexion ability seem to perform better on clinical and functional outcomes. Furthermore, the adjusted design of the bicruciate-stabilizing TKA reduced the number of adverse events. LEVEL OF EVIDENCE: Prospective cohort study, Level II.


Assuntos
Artroplastia do Joelho , Amplitude de Movimento Articular/fisiologia , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Artroplastia do Joelho/estatística & dados numéricos , Humanos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Estudos Prospectivos , Resultado do Tratamento
20.
Global Spine J ; 10(3): 294-302, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32313795

RESUMO

STUDY DESIGN: Prospective cohort study. OBJECTIVE: To investigate the primary stability of the Prodisc-C Vivo cervical disc arthroplasty with regard to the adjacent cervical vertebrae using radiostereometric analysis (RSA), and to monitor its clinical performance. METHODS: Sixteen patients with degenerative cervical disc disease were included. RSA radiographs were obtained at the first postoperative day, at 6 weeks, 3 months, and 6 months postoperatively. Migration (translation [mm]) of the superior and inferior implant components were measured with model-based RSA, expressed along the 3 orthogonal axes, and calculated as total translation. Clinical outcomes were Neck Disability Index, numeric rating scales for neck and arm pain, Likert-type scales for satisfaction, and adverse events. Range of motion was reported as C2-C7 flexion-extension mobility (ROM). RESULTS: At final follow-up, no significant increase over time in median total translation was found. One inferior and 3 superior components subsided but were asymptomatic. ROM remained stable and clinical outcomes improved over time. Although 3 patients were unsatisfied and 3 adverse events occurred, this was not related to translation of the components. CONCLUSIONS: On a group level, both components of the Prodisc-C Vivo cervical disc arthroplasty remained stable over time and below the clinical threshold of 1 mm. Individual outliers for translation were not clinically relevant and probably related to settling of the components into the vertebral endplates. RSA allowed us to perform a preliminary but accurate study on the micromotion of a new cervical disc replacement in a small sample size, without putting large numbers of patients at risk.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA