Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Int J Bioprint ; 9(4): 727, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37323487

RESUMO

Despite advances in prosthesis materials, operating microscopes and surgical techniques during the last 50 years, long-lasting hearing improvement remains a challenge in ossicular chain reconstruction. Failures in the reconstruction are mainly due to inadequate length or shape of the prosthesis, or defects in the surgical procedure. 3D-printed middle ear prosthesis might offer a solution to individualize treatment and obtain better results. The aim of the study was to study the possibilities and limitations of 3D-printed middle ear prostheses. Design of the 3D-printed prosthesis was inspired by a commercial titanium partial ossicular replacement prosthesis. 3D models of different lengths (1.5-3.0 mm) were created with Solidworks 2019-2021 software. The prostheses were 3D-printed with vat photopolymerization using liquid photopolymer Clear V4. Accuracy and reproducibility of 3D printing were evaluated with micro-CT imaging. The acoustical performance of the prostheses was determined in cadaver temporal bones with laser Doppler vibrometry. In this paper, we present an outline of individualized middle ear prosthesis manufacturing. 3D printing accuracy was excellent when comparing dimensions of the 3D-printed prostheses and their 3D models. Reproducibility of 3D printing was good if the diameter of the prosthesis shaft was 0.6 mm. 3D-printed partial ossicular replacement prostheses were easy to manipulate during surgery even though they were a bit stiffer and less flexible than conventional titanium prostheses. Their acoustical performance was similar to that of a commercial titanium partial ossicular replacement prosthesis. It is possible to 3D print functional individualized middle ear prostheses made of liquid photopolymer with good accuracy and reproducibility. These prostheses are currently suitable for otosurgical training. Further research is needed to explore their usability in a clinical setting. In the future, 3D printing of individualized middle ear prostheses may provide better audiological outcomes for patients.

2.
BMC Med Imaging ; 23(1): 51, 2023 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-37038130

RESUMO

BACKGROUND: Multi slice computed tomography (MSCT) is the most common used method in middle ear imaging. However, MSCT lacks the ability to distinguish the ossicular chain microstructures in detail resulting in poorer diagnostic outcomes. Novel cone beam computed tomography (CBCT) devices' image resolution is, on the other hand, better than MSCT resolution. The aim of this study was to optimize imaging parameters of a novel full body CBCT device to obtain optimal contrast to noise ratio (CNR) with low effective dose, and to optimize its clinical usability. METHODS: Imaging of five anonymous excised human cadaver temporal bones, the acquisition of the effective doses and the CNR measurements were performed for images acquired on using Planmed XFI® full body CBCT device (Planmed Oy, Helsinki, Finland) with a voxel size of 75 µm. All images acquired from the specimens using 10 different imaging protocols varying from their tube current exposure time product (mAs) and tube voltage (kVp) were analyzed for eight anatomical landmarks and evaluated by three evaluators. RESULTS: With the exception of protocol with 90 kVp 100 mAs, all other protocols used are competent to image the finest structures. With a moderate effective dose (86.5 µSv), protocol with 90 kV 450 mAs was chosen the best protocol used in this study. A significant correlation between CNR and clinical image quality of the protocols was observed in linear regression model. Using the optimized imaging parameters, we were able to distinguish even the most delicate middle ear structures in 2D images and produce accurate 3D reconstructions. CONCLUSIONS: In this ex vivo experiment, the new Planmed XFI® full body CBCT device produced excellent 2D resolution and easily created 3D reconstructions in middle ear imaging with moderate effective doses. This device would be suitable for middle ear diagnostics and for e.g., preoperative planning. Furthermore, the results of this study can be used to optimize the effective dose by selecting appropriate exposure parameters depending on the diagnostic task.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada por Raios X/métodos , Orelha Média/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA