Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Front Cardiovasc Med ; 9: 922357, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35966546

RESUMO

Background: During on-pump coronary artery bypass grafting (ONCAB), graft flushing for distal anastomoses testing also perfuses the downstream myocardium. This single-center retrospective study evaluated the impact of specific preservation solutions on myocardial protection during ONCAB. Materials and methods: Between July 2019 and March 2020 either DuraGraft (DG) or 0.9% Saline/Biseko (SB) was applied to 272 ONCAB. Overall, 166 patients were propensity-matched into two groups. Cardiac enzymes [high-sensitive Troponin I (hs-TnI) and creatine kinase (CK)] were evaluated 7 days post-surgery. Results: Post-surgery, hs-TnI values were significantly lower from 3 to 6 h (h) up to 4 days in the DG group: 3-6 h: 4,034 ng/L [IQR 1,853-8,654] vs. 5,532 ng/L [IQR 3,633-8,862], p = 0.05; 12-24 h: 2,420 ng/L [IQR 1,408-5,782] vs. 4,166 [IQR 2,052-8,624], p < 0.01; 2 days: 1,095 ng/L [IQR 479-2,311] vs. 1,564 ng/L [IQR 659-5,057], p = 0.02 and at 4 days: 488 ng/L [IQR 232-1,061] vs. 745 ng/L [IQR 319-1,820], p = 0.03. The maximum value: 4,151 ng/L [IQR 2,056-8,621] vs. 6,349 ng/L [IQR 4,061-12,664], p < 0.01 and the median area under the curve (AUC): 6,146 ng/L/24 h [IQR 3,121-13,248] vs. 10,735 ng/L/24 h [IQR 4,859-21,484], p = 0.02 were lower in the DG group. CK values were not significantly different between groups: maximum value 690 [IQR 417-947] vs. 631 [464-979], p = 0.61 and AUC 1,986 [1,226-2,899] vs. 2,081 [1,311-3,063], p = 0.37. Conclusion: Repeated graft flushing with DG resulted in lower Troponin values post-surgery suggesting enhanced myocardial protection compared to SB. Additional studies are warranted to further assess the myocardial protection properties of DG.

2.
Eur J Cardiothorac Surg ; 62(5)2022 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-35543473

RESUMO

OBJECTIVES: The aim of this study was to explore sex and gender differences regarding aortic events in Marfan patients. METHODS: We analysed all data from our connective tissue disorder database. Only patients with Marfan syndrome were included. For analysis, patients were divided by sex. Female patients were further divided into 2 subgroups: with versus without children. Aortic events were defined as Stanford type A aortic dissection (TAAD) or type B aortic dissection (TBAD) or any aortic intervention. RESULTS: A population of 183 Marfan patients was analysed for the purpose of this study. One hundred four (57%) were male and 79 (43%) were female patients. Thirty-seven (47%) of the 79 female patients had at least 1 child. Male patients had a significantly higher probability of experiencing an aortic event (P = 0.015) compared to female patients. However, there was no increased probability for recurrent events in male patients compared to female patients (P = 0.063). Follow-up revealed no sex and gender differences in the occurrence of Stanford TAAD or TBAD between male and female patients (P = 0.324/P = 0.534). While 11% of women with children suffered from peripartum aortic events, 24% experienced Stanford TAAD unrelated to pregnancy. CONCLUSIONS: Male patients have a higher risk of aortic events than female patients. The majority of women were not aware of their Marfan syndrome diagnosis before conceiving. One out of 10 women suffered from peripartum Stanford TAAD or TBAD. Twice as many female patients with children suffered from aortic dissection unrelated to childbirth. There were no sex and gender differences affecting mortality in Marfan patients.


Assuntos
Dissecção Aórtica , Síndrome de Marfan , Criança , Humanos , Feminino , Masculino , Síndrome de Marfan/complicações , Síndrome de Marfan/epidemiologia , Síndrome de Marfan/cirurgia , Dissecção Aórtica/epidemiologia , Dissecção Aórtica/etiologia , Aorta/diagnóstico por imagem , Aorta/cirurgia
4.
Swiss Med Wkly ; 149: w20096, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31269224

RESUMO

AIM OF STUDY: To report our experience of late correction after infancy in patients with tetralogy of Fallot (ToF). METHODS: Observational single-centre retrospective analysis of the surgical techniques and perioperative development of patients from developing countries undergoing total surgical correction of ToF after infancy, between 1 November 2011 and 30 November 2016. Variables are presented as numbers with percentages or as mean ± standard deviation. Due to the setting of the humanitarian programme, clinical and echocardiographic follow-up procedures could be conducted for only one month postoperatively. RESULTS: Twenty-five children (mean age: 70.8 ± 42 months, range 23-163; 44% female) underwent total surgical correction of ToF. Two patients (0.8%) initially received a Blalock-Taussig shunt and underwent subsequent correction 24 and 108 months later, respectively. Preoperative mean right ventricular/pulmonary artery (RV/PA) gradient was 84 ± 32 mm Hg, with a Nakata index of 164 ± 71 mm2/m2. Major aortopulmonary collateral arteries (MAPCAs) were observed in eight children (32%), six (26%) of whom underwent transcatheter closure before surgery. 24 children (96%) underwent a valve-sparing pulmonary valve repair and one patient received a transannular patch (TAP). There were no cases which saw major adverse cardiac and cerebrovascular events (MACCE). Mean duration of mechanical ventilation was 28 ± 19.6 hours (range 7-76). Pre-discharge echocardiography demonstrated a mean RV/PA gradient of 25 ± 5.7 mm Hg, with left ventricular ejection fraction >60% in all cases. Overall length of hospital stay was 11.7 ± 4.5 days. There were no in-hospital mortality cases. CONCLUSIONS: Late surgical correction of ToF can be safely performed and produce highly satisfying early postoperative results comparable to those of classical “timely” correction. A valve-sparing technique can be applied in the majority of children.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Artéria Pulmonar/fisiopatologia , Reoperação/estatística & dados numéricos , Tetralogia de Fallot/cirurgia , Pré-Escolar , Ecocardiografia , Feminino , Humanos , Masculino , Estudos Retrospectivos
5.
J Cardiothorac Surg ; 12(1): 47, 2017 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-28606165

RESUMO

BACKGROUND: Simultaneous transapical implantation of transcatheter heart valves in the native mitral and aortic position may be considered as an alternative to surgical valve replacement in high-risk patients presenting with combined valve disease. CASE PRESENTATION: A 59-year-old female with severe aortic stenosis, severe mitral stenosis with mild mitral insufficiency, persistent atrial fibrillation, severe chronic obstructive pulmonary disease and NYHA class of IV was evaluated by our interdisciplinary heart team. Due to the calculated Euroscore II, logistic Euroscore with 10% and 17% a decision was made towards a transapical TAVI approach. The implantation of a Sapien 3 (Edwards Lifesciences) valve in the aortic position was performed and the perioperative TEE showed a good result. The preoperative imaging revealed a narrow LVOT with risk for post interventional left ventricular outflow tract obstruction. Accordingly, it was decided against the use of balloon-expanding valves for the mitral valve position in the interdisciplinary team, as it is not repositionable. Instead, it was decided for the use of a Lotus (Boston Scientific) valve, as it is repositionable and therefore possible to retract in case of LVOT obstruction. In the present case of double valve intervention, the implantation attempt of a fully repositionable transcatheter heart valve into the native mitral annulus resulted in acute LVOT obstruction requiring immediate removal of the device. The patient was extubated and experienced uneventful postoperative recovery. CONCLUSIONS: The case shows that improved preoperative work-up is necessary for better prediction of significant LVOT obstruction following transcatheter mitral valve implantation. In borderline cases, the use of a fully repositionable device is preferred.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Estenose da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Ecocardiografia/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Estenose da Valva Mitral/complicações , Estenose da Valva Mitral/diagnóstico , Desenho de Prótese , Índice de Gravidade de Doença
6.
Ann Thorac Surg ; 103(1): 342-350, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27780561

RESUMO

The pathophysiologic side effects of cardiopulmonary bypass have already been identified. Minimally invasive extracorporeal circulation technologies (MiECT) and off-pump coronary artery bypass graft surgery (OPCABG) aim to reduce these problems. This meta-analysis provides a comparison of MiECT and OPCABG in randomized and observational studies. A fully probabilistic, Bayesian approach of primary and secondary endpoints was conducted. MiECT does not give inferior results when compared with OPCABG. However, there is a trend to borderline significantly higher blood loss in this group in randomized controlled trials. The question whether MiECT is equivalent to OPCABG can be answered with the affirmative, but long-term follow-up data are needed to detect any advantage over time.


Assuntos
Teorema de Bayes , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Doença da Artéria Coronariana/cirurgia , Circulação Extracorpórea/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Humanos
7.
Eur J Cardiothorac Surg ; 50(1): 98-104, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26719402

RESUMO

OBJECTIVES: Long-term follow-up reports after implantation of the Shelhigh® (Shelhigh, Inc., NJ, USA) No-React® aortic valved conduit used for aortic root replacement do not exist. METHODS: Between November 1998 and December 2007, the Shelhigh® No-React® aortic valved conduit was implanted in 291 consecutive patients with a mean age of 69.6 ± 9.1 years, and 33.7% were female (n = 98). Indications were annulo-aortic ectasia (n = 202), aortic valve stenosis combined with ascending aortic aneurysm (n = 67), acute type A aortic dissection (n = 29), endocarditis (n = 26) and other related pathologies (n = 48) including 62 patients with previous cardiac surgery. Data from two cardiac institutions were analysed retrospectively using SPSS (SPSS Software IBM, Inc., 2014, NY, USA). RESULTS: Operative mortality was 10% (n = 29). Main cause of death was cardiac failure in 15 patients (51.8%), neurological events in 6 patients (20.7%), respiratory failure in 4 patients (13.8%), bleeding complications in 2 patients (6.9%) and gastrointestinal ischaemia in 2 cases (6.9%). There were 262 hospital survivors and all were entered in the follow-up study (100% complete). During the long-term follow-up (mean 70.3 ± 53.1 in months), a total of 126/262 patients (44.3%) died. Main causes of death in patients after discharge were cardiac (n = 37, 14.1%), neurological (n = 15, 5.7%) respiratory (n = 12, 4.6%), endocarditis (n = 12, 4.6%) and peripheral vascular disease (n = 5, 1.9%). In 29 (11.1%) patients, the cause of death could not be determined. Reoperation was required in 25 (8.6%) patients due to infection of the conduit (n = 9), aortoventricular disconnection (n = 4), pseudoaneurysm formation (n = 4) and structural valve degeneration (n = 8). Reoperations were performed 5.0 ± 3.8 (range 0.1-11.7) years after index surgery. CONCLUSIONS: The Shelhigh® No-React® aortic valved conduit showed satisfactory short-term operative results. However, the long-term follow-up revealed a relatively high rate of deaths, which may be explained by the epidemiology of the patient group, but a substantial proportion of deaths could not be clarified. The overall rate of reoperation (8.6%) during the mid-term follow-up is worrisome and the failures due to aortoventricular disconnection, endocarditis and pseudoaneurysm formation remain unexplained. The redo-procedures were technically demanding. We recommend close follow-up of patients with the Shelhigh® No-React® aortic valved conduit, because besides classical structural valve degeneration, unexpected findings may be observed.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Adolescente , Adulto , Assistência ao Convalescente , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/cirurgia , Insuficiência da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/mortalidade , Endocardite/etiologia , Endocardite/mortalidade , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA