Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
2.
Catheter Cardiovasc Interv ; 98(5): 904-913, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34398509

RESUMO

The Society for Cardiovascular Angiography and Interventions (SCAI) Think Tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community annually for high-level field-wide discussions. The 2021 Think Tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease. Each session was moderated by a senior content expert and co-moderated by a member of SCAI's Emerging Leader Mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialog from a broader base, and thereby aid SCAI, the industry community and external stakeholders in developing specific action items to move these areas forward.


Assuntos
Cardiologistas , Cardiologia , Cardiopatias Congênitas , Angiografia , Humanos , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 98(5): 950-956, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34227736

RESUMO

The aim of the study was to estimate the percentage of Medicare patients needing coronary access for percutaneous coronary intervention (PCI) or coronary angiography following aortic valve replacement (AVR). Indications for TAVR have expanded to include younger and low-risk patients, raising the question of coronary access for future procedures. Medicare patients <80 years old with an AVR between 2011 and 2018 were included. Time-to-event analyses were conducted using Cox hazard models to estimate risk of coronary access up to 7 years after AVR. Model adjustments included age, sex, race, region, comorbidity, concomitant CABG, and smoking. A total of 13,469 Medicare patients (mean age 70.6) met inclusion criteria. Models estimated that 2.5% of patients at 1-year post-index and 17% at over 7 years would need coronary access. For patients who had SAVR (with or without CABG), estimates for coronary access were similar and over 15% after 6.5 years. For TAVR patients, with a previous PCI, 28% at 4.5 years required coronary access, which was higher than TAVR patients without a previous PCI. SAVR patients with and without CAD at baseline were similar; however, TAVR patients with CAD had a 22% rate of coronary access versus 7% for those without at 3 years. Approximately half of patients who needed coronary access returned to the same hospital as their initial AVR. Coronary access is required in a substantial portion of AVR patients especially those with PCI or a history of CAD undergoing TAVR. The need for coronary access may increase as transcatheter AVR becomes accessible to younger patients with a longer life expectancy.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Medicare , Intervenção Coronária Percutânea/efeitos adversos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estados Unidos/epidemiologia
5.
JACC Cardiovasc Interv ; 14(9): 1009-1018, 2021 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-33640388

RESUMO

OBJECTIVES: The authors sought to determine whether coronary artery tortuosity negatively affects clinical outcomes after stent implantation. BACKGROUND: Coronary artery tortuosity is a common angiographic finding and has been associated with increased rates of early and late major adverse events after balloon angioplasty. METHODS: Individual patient data from 6 prospective, randomized stent trials were pooled. Outcomes at 30 days and 5 years following percutaneous coronary intervention of a single coronary lesion were analyzed according to the presence or absence of moderate/severe vessel tortuosity, as determined by an angiographic core laboratory. The primary endpoint was target vessel failure (TVF) (composite of cardiac death, target vessel-related myocardial infarction [TV-MI], or ischemia-driven target vessel revascularization [ID-TVR]). RESULTS: A total of 6,951 patients were included, 729 of whom (10.5%) underwent percutaneous coronary intervention in vessels with moderate/severe tortuosity. At 30 days, TVF was more frequent in patients with versus without moderate/severe tortuosity (3.8% vs. 2.4%; hazard ratio [HR]: 1.64; 95% confidence interval [CI]: 1.09 to 2.46; p = 0.02), a difference driven by a higher rate of TV-MI. At 5 years, TVF remained increased in patients with moderate/severe tortuosity (p = 0.003), driven by higher rates of TV-MI (p = 0.003) and ID-TVR (p = 0.01). Definite stent thrombosis was also greater in patients with versus without moderate/severe tortuosity (1.9% vs. 1.0%; HR: 1.86; 95% CI: 1.02 to 3.39; p = 0.04). After adjustment for baseline covariates, moderate/severe vessel tortuosity was independently associated with TV-MI and ID-TVR at 5 years (p = 0.04 for both). CONCLUSIONS: Stent implantation in vessels with moderate/severe coronary artery tortuosity is associated with increased rates of TVF due to greater rates of TV-MI and ID-TVR.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Fatores de Risco , Stents , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 96(6): 1258-1265, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32840956

RESUMO

The society for cardiovascular angiography and interventions (SCAI) think tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community for high-level field-wide discussions. The 2020 think tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease (CHD). Each session was moderated by a senior content expert and co-moderated by a member of SCAI's emerging leader mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialogue from a broader base, and thereby aid SCAI and the industry community in developing specific action items to move these areas forward.


Assuntos
Cateterismo Cardíaco/tendências , Cardiologia/tendências , Angiografia Coronária/tendências , Cardiopatias/diagnóstico por imagem , Cardiopatias/terapia , Intervenção Coronária Percutânea/tendências , Difusão de Inovações , Cardiopatias/fisiopatologia , Humanos
7.
JACC Cardiovasc Interv ; 13(2): 219-231, 2020 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-31973795

RESUMO

OBJECTIVES: This study sought to evaluate the ability of individual markers of frailty to predict outcomes after transcatheter aortic valve replacement (TAVR) and of their discriminatory value in different age groups. BACKGROUND: Appropriate patient selection for TAVR remains a dilemma, especially among the most elderly and potentially frail. METHODS: The study evaluated patients ≥65 years of age in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy registry, linked to Centers for Medicare and Medicaid administrative claims data, receiving elective TAVR from November 2011 to June 2016 (n = 36,242). Indices of frailty included anemia, albumin level, and 5-m walk speed. We performed Cox proportional hazards regression for 30-day and 1-year mortality, adjusting for risk factors known to be predictive of 30-day mortality in the Transcatheter Valve Therapy registry, as well as survival analysis. RESULTS: These indices are independently associated with mortality at 30 days and 1 year and provide incremental value in risk stratification for mortality, with low albumin providing the largest value (hazard ratio: 1.52). Those with low albumin and slower walking speed had longer lengths of stay and higher rates of bleeding and readmission (p < 0.001). Those with anemia also had higher rates of bleeding, readmission, and subsequent myocardial infarction (p < 0.001). CONCLUSIONS: This represents the largest study to date of the role of frailty indices after TAVR, further facilitating robust modeling and adjusting for a large number of confounders. These simple indices are easily attainable, and clinically relevant markers of frailty that may meaningfully stratify patients at risk for mortality after TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Idoso Fragilizado , Fragilidade/diagnóstico , Avaliação Geriátrica , Substituição da Valva Aórtica Transcateter , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Bases de Dados Factuais , Feminino , Fragilidade/mortalidade , Fragilidade/fisiopatologia , Hemodinâmica , Humanos , Masculino , Valor Preditivo dos Testes , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos
8.
Cardiovasc Revasc Med ; 21(3): 263-270, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31255552

RESUMO

BACKGROUND: Predictors of hospital readmissions and tools to predict readmissions after TAVR are scarce. Our objective was to identify predictors of early hospital readmission following TAVR in contemporary clinical practice and develop a risk calculator. METHODS: Patients with a contemporary self-expanding TAVR between 2015 and 2017 in the STS/ACC/TVT Registry™ database were included. Patients were divided into a derivation and validation cohort (2:1). A risk score was calculated using the derivation cohort based on multivariable predictors of 30-day unplanned readmissions and applied to the validation cohort. RESULTS: A total of 10,345 TAVR patients at 350 centers were included. Unplanned 30-day hospital readmission was 9.2%. Patients with an early readmission had higher 30-day rates for mortality (2.3% vs. 0.8%, p ≪ 0.001), stroke (4.1% vs. 2.7% p = 0.009), major vascular complications (2.0% vs. 1.0%, p = 0.003) and new pacemaker implantation (25.7% vs. 18.6%, p ≪ 0.001). Multivariable predictors of 30-day readmission included diabetes, atrial fibrillation, advanced heart failure symptoms, home oxygen, decreased 5-m gait speed or the inability to walk, serum creatinine ≫1.6 mg/dL, index hospitalization length of stay ≫5 days, major vascular complication and ≥ moderate post-procedure aortic or mitral valve regurgitation. Based on these predictors, we stratified 30-day readmission risk into low-, moderate- and high-risk subsets. There was a 2.5× difference in readmission rates between the low- (5.8%) and high-risk subsets (14.6%). CONCLUSION: We stratified the risk of early hospital readmission after TAVR based on a simple scoring system. This score may improve discharge planning centered on the individual's readmission risk. SUMMARY: Unplanned readmissions in the United States are prevalent and costly accounting for $41.3 billion in annual hospital payments and are associated with adverse clinical outcomes. We found that diabetes, atrial fibrillation, advanced heart failure symptoms, home oxygen, frailty, acute kidney injury, prolonged hospitalization, major vascular complications, and moderate or worse post-procedure aortic or mitral valve regurgitation predicted of 30-day readmission following self-expanding TAVR. This information may improve discharge planning centered on each patient's readmission risk.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Oxigênio , Readmissão do Paciente , Sistema de Registros , Fatores de Risco , Resultado do Tratamento , Estados Unidos/epidemiologia
9.
Circ Cardiovasc Interv ; 12(10): e008155, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31607151

RESUMO

BACKGROUND: Valve-in-valve transcatheter aortic valve replacement (TAVR) is an option when a surgical valve demonstrates deterioration and dysfunction. This study reports 3-year results following valve-in-valve with self-expanding TAVR. METHODS: The CoreValve US Expanded Use Study is a prospective, nonrandomized, single-arm study that evaluates safety and effectiveness of TAVR in extreme risk patients with symptomatic failed surgical biologic aortic valves. Study end points include all-cause mortality, need for valve reintervention, hemodynamic changes over time, and quality of life through 3 years. Patients were stratified by presence of preexisting surgical valve prosthesis-patient mismatch. RESULTS: From March 2013 to May 2015, 226 patients deemed extreme risk (STS-PROM [Society of Thoracic Surgeons Predicted Risk of Mortality] 9.0±7%) had attempted valve-in-valve TAVR. Preexisting surgical valve prosthesis-patient mismatch was present in 47.2% of the cohort. At 3 years, all-cause mortality or major stroke was 28.6%, and 93% of patients were in New York Heart Association I or II heart failure. Valve performance was maintained over 3 years with low valve reintervention rates (4.4%), an improvement in effective orifice area over time and a 2.7% rate of severe structural valve deterioration. Preexisting severe prosthesis-patient mismatch was not associated with 3-year mortality but was associated with significantly less improvement in quality of life at 3-year follow-up (P=0.01). CONCLUSIONS: Self-expanding TAVR in patients with failed surgical bioprostheses at extreme risk for surgery was associated with durable hemodynamics and excellent clinical outcomes. Preexisting surgical valve prosthesis-patient mismatch was not associated with mortality but did limit patient improvement in quality of life over 3-year follow-up. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01675440.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Bioprótese , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
10.
Am J Cardiol ; 124(7): 1091-1098, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31362879

RESUMO

Transcatheter aortic valve implantation with a bioprosthetic valve of insufficient size is associated with a higher risk of aortic regurgitation (AR). The 31-mm CoreValve and the next generation 34-mm Evolut R bioprostheses were designed to address the need for larger diameter aortic annuli. This analysis examined the clinical and hemodynamic outcomes following commercial transcatheter aortic valve implantation with the 31-mm CoreValve and 34-mm Evolut R in the Society of Thoracic Surgeons/the American College of Cardiology Transcatheter Valve Therapy Registry. Patients receiving a 31-mm CoreValve or 34-mm Evolut R valve for symptomatic severe native aortic stenosis from January 2014 to September 2017 in the Transcatheter Valve Therapy Registry underwent propensity score matching using baseline demographics, clinical and frailty measures, and procedural variables. Procedural characteristics, in-hospital and 30-day clinical and echocardiographic outcomes were compared. Of 4545 patients implanted with a 31-mm CoreValve and 3036 patients with a 34-mm Evolut R valve, matching resulted in 1813 patient sets. Most patients were male (>92%), elderly (∼80 years) with the Society of Thoracic Surgeons score of 6.6%. Use of the 34-mm versus 31-mm valve resulted in shorter median procedural time (113.0 [85.0, 150.0] vs 93.0 [71.0, 126.0] min, p <0.001), higher device success (98.1% vs 93.9%, p <0.001), fewer pacemakers (16.7% vs 24.6%, p <0.001), less ≥moderate AR with the 34-mm (5.5% vs 13.7%), p <0.001) and shorter hospital stay (3.0 [2.0, 4.0] vs 4.0 [3.0, 6.0] days, p <0.001). In conclusion, this largest experience with the 34-mm Evolut R valve showed higher device success, reduced hospital stay, lower pacemaker rates and less ≥moderate AR compared with the 31-mm CoreValve bioprosthesis.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Humanos , Tempo de Internação , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Pontuação de Propensão , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
11.
Am J Cardiol ; 124(5): 781-788, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31311661

RESUMO

Transcatheter aortic valve implantation (TAVI) is approved for treatment of symptomatic aortic stenosis in patients at increased risk for surgical valve replacement, but outcomes data in patients with severe native aortic regurgitation (AR) treated with TAVI remain limited. The objective of this analysis was to evaluate outcomes among patients identified in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapies Registry who underwent TAVI for native AR with a commercially available self-expanding valve system. From January 2014 to December 2017, 230 patients in the TVT Registry underwent TAVI for primary severe native AR using a commercially available self-expanding valve (n = 81, CoreValve; n = 149, Evolut R). For inclusion, AR was either pure or mixed with predominantly moderate/severe AR and mean aortic valve gradient ≤20 mm Hg. Thirty-day outcomes were evaluated using time-to-event methods. Device success was reported in 81.7% of patients (CoreValve, 72.2%; Evolut R, 86.9%; p = 0.0.01). Thirty-day all-cause mortality was 13.3%. All patients presented with moderate/severe AR at baseline; at 30 days, 9.1% of implanted patients with data continued to have moderate and 1.4% severe AR. There was a significant reduction in residual moderate/severe AR from the CoreValve to Evolut R device (19.1% vs 6.3%, p = 0.02). Multivariable analysis revealed factors associated with 30-day all-cause mortality include number of valves used (hazard ratio [HR] 2.361, 1.643 to 3.391, p <0.001), albumin < 3.3 mg/dL (HR 3.358, 1.551 to 7.273, p=0.002), and left ventricular ejection fraction (HR 0.978, 0.957 to 1.000, p = 0.047). Despite higher 30-day all-cause mortality, self-expanding TAVI may be an option in selected patients with AR who have no surgical options.


Assuntos
Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Causas de Morte , Feminino , Mortalidade Hospitalar/tendências , Humanos , Masculino , Análise Multivariada , Prognóstico , Modelos de Riscos Proporcionais , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Taxa de Sobrevida , Resultado do Tratamento
12.
Am Heart J ; 211: 45-53, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30831333

RESUMO

The Amulet IDE Trial is an ongoing, prospective, randomized, multi-national trial, designed to evaluate the safety and effectiveness of the AMPLATZER Amulet Left Atrial Appendage Occluder for stroke prevention in comparison to the WATCHMAN Left Atrial Appendage Closure Device in patients with non-valvular atrial fibrillation. METHODS: Non-valvular atrial fibrillation patients at high risk of stroke (CHADS2 score ≥2 or a CHA2DS2-VASc score of ≥3) who are suitable candidates for left atrial appendage occlusion (LAAO) will be fully informed and requested to participate in the trial. A total of 1878 patients at up to 150 sites worldwide will be randomized in a 1:1 ratio between the AMPLATZER Amulet device (investigational) and the Boston Scientific WATCHMAN device (control). Each patient will be followed for 5 years, with follow-up assessments at discharge, 45 days, 3, 6, 9, 12, 18, and 24 months and then annually. The trial has three primary endpoints: A composite of procedure-related complications, or all-cause death, or major bleeding through 12 months (safety); a composite of ischemic stroke or systemic embolism through 18 months (effectiveness); and effective device LAAO, defined as residual jet around the device ≤5 mm at the 45-day visit (mechanism of action). SUMMARY: The Amulet IDE Trial is the first randomized head-to-head LAAO device trial and will provide data for the AMPLATZER Amulet occluder in a population with a high risk of stroke and bleeding.


Assuntos
Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/instrumentação , Dispositivo para Oclusão Septal , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Cateterismo Cardíaco , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Causas de Morte , Fibrinolíticos/efeitos adversos , Fibrinolíticos/uso terapêutico , Hemorragia/induzido quimicamente , Hemorragia/prevenção & controle , Humanos , Complicações Pós-Operatórias , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Dispositivo para Oclusão Septal/efeitos adversos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
13.
Heart ; 105(21): 1622-1628, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30077993

RESUMO

OBJECTIVES: This study evaluates the 5-year clinical outcomes of transcatheter mitral valve (MV) repair with the MitraClip device in patients at high risk for MV surgery treated in the Endovascular Valve Edge-to-Edge Repair (EVEREST) II High Risk Study (HRS). METHODS: Patients with mitral regurgitation (MR) 3+ or 4+ and predicted surgical mortality risk ≥12% or surgeon assessment based on prespecified high-risk factors were enrolled. Patients prospectively consented to 5 years of follow-up. RESULTS: At 5 years, clinical follow-up was achieved in 90% of 78 enrolled patients. The rate of postprocedural adverse events declined from 30 days to 1 year follow-up and was stable thereafter through 5 years. Two patients (2.6%) developed mitral stenosis (MS). Two patients underwent MV surgery, including one due to MS. A total of 42 deaths were reported through 5 years. Effectiveness measures at 5 years showed reductions in MR severity to ≤2+ in 75% of patients (p=0.0107), left ventricular (LV) end-diastolic volume (-38.2 mL; 95% CI -55.0 to -21.4; p<0.0001) and LV end-systolic volume (-14.6 mL; 95% CI -27.7 to -1.5; p=0.0303) compared with baseline. The New York Heart Association (NYHA) functional class improved from baseline to 5 years (p<0.005), and septal-lateral annular dimensions remained stable with no indication of mitral annular dilation through 5 years. CONCLUSIONS: The EVEREST II HRS demonstrated long-term safety and efficacy of MitraClip in high-surgical-risk patients through 5 years. The observed mortality was most likely a consequence of the advanced age and comorbidity profile of the enrolled patients, while improvements in NYHA class in surviving patients were durable through long-term follow-up. TRIAL REGISTRATION NUMBER: NCT01940120.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Ventrículos do Coração/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Complicações Pós-Operatórias/epidemiologia , Medição de Risco/métodos , Idoso , Ecocardiografia , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Incidência , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/mortalidade , Estudos Prospectivos , Fatores de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Fatores de Tempo , Estados Unidos/epidemiologia , Função Ventricular Esquerda/fisiologia
14.
JAMA Cardiol ; 3(12): 1151-1159, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30476950

RESUMO

Importance: Improvements in symptoms, functional capacity, and quality of life are among the key goals of edge-to-edge transcatheter mitral valve repair (TMVR) for mitral regurgitation. Objective: To examine health status outcomes among patients undergoing TMVR in clinical practice and the factors associated with improvement. Design, Setting, and Participants: This cohort study used the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry, which contains data on patients with severe mitral regurgitation treated with TMVR from 2013 through 2017 in 217 US hospitals. Main Outcomes and Measures: Change in disease-specific health status (Kansas City Cardiomyopathy Questionnaire-Overall Summary score [KCCQ-OS]; range 0-100 points, with higher scores indicating better health status) at 30 days and 1 year after TMVR. We also examined factors associated with health status at 30 days after TMVR, by means of multivariable linear regression using a generalized estimating equations approach to account for clustering of patients within sites. Results: The KCCQ data were available in 81.2% at baseline, 69.3% of survivors at 30 days, and 47.4% of survivors at 1 year. Among 4226 patients who underwent TMVR, survived 30 days, and completed the KCCQ at baseline and follow-up, the KCCQ-OS increased from 41.9 before TMVR to 66.7 at 30 days (mean change 24.8 [95% CI, 24.0-25.6] points; P < .001), representing a large clinical improvement. The KCCQ scores remained stable from 30 days to 1 year after TMVR, with no further significant increase or decline. On multivariable analysis, atrial fibrillation (-2.2 [95% CI, -3.7 to -0.6] points; P = .01), permanent pacemaker (-2.1 [95% CI, -3.7 to -0.4] points; P = .01), severe lung disease (-3.9 [95% CI, -6.2 to -1.5] points; P = .001), home oxygen (-2.7 [95% CI, -4.9 to -0.4] points; P = .02), and lower KCCQ scores at baseline (3.9 points for each 10-point increase [95% CI, 3.6-4.2]; P < .001) were independently associated with lower 30-day KCCQ-OS scores. In-hospital renal failure was uncommon but was also associated with significant reductions in 30-day KCCQ-OS scores (-7.3 [95% CI -13.3 to -1.2] points). In estimates calculated with inverse probability weighting, after 1 year after TMVR, 54.2% (95% CI 52.2%-56.1%) of patients were alive and well; 23.0% had died, 21.9% had persistently poor health status (KCCQ-OS <60 points), 5.5% had a health status decline from baseline, and 4.6% had both poor health status and health status decline. Conclusions and Relevance: In a national cohort of US patients undergoing edge-to-edge TMVR in clinical practice, health status was impaired prior to the procedure, improved within 30 days, and remained stable through 1 year among surviving patients with available data. While long-term mortality remains high, most surviving patients demonstrate improvements in symptoms, functional status, and quality of life, with only modest differences by patient-level factors.


Assuntos
Cateterismo Cardíaco/métodos , Nível de Saúde , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Qualidade de Vida , Sistema de Registros , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Insuficiência da Valva Mitral/psicologia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
15.
J Am Coll Cardiol ; 72(22): 2687-2696, 2018 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-30249462

RESUMO

BACKGROUND: The CoreValve U.S. Pivotal High Risk Trial was the first randomized trial to show superior 1-year mortality of transcatheter aortic valve replacement (TAVR) compared with surgical aortic valve replacement (SAVR) among high operative mortality-risk patients. OBJECTIVES: The authors sought to compare TAVR to SAVR for mid-term 5-year outcomes of safety, performance, and durability. METHODS: Surgical high-risk patients were randomized (1:1) to TAVR with the self-expanding bioprosthesis or SAVR. VARC-1 (Valve Academic Research Consortium I) definitions were applied. Severe hemodynamic structural valve deterioration was defined as a mean gradient ≥40 mm Hg or a change in gradient ≥20 mm Hg or new severe aortic regurgitation. Five-year follow-up was planned. RESULTS: A total of 797 patients were randomized at 45 U.S. centers, of whom 750 underwent an attempted implant (TAVR = 391, SAVR = 359). The overall mean age was 83 years, and the STS score was 7.4%. All-cause mortality rates at 5 years were 55.3% for TAVR and 55.4% for SAVR. Subgroup analysis showed no differences in mortality. Major stroke rates were 12.3% for TAVR and 13.2% for SAVR. Mean aortic valve gradients were 7.1 ± 3.6 mm Hg for TAVR and 10.9 ± 5.7 mm Hg for SAVR. No clinically significant valve thrombosis was observed. Freedom from severe SVD was 99.2% for TAVR and 98.3% for SAVR (p = 0.32), and freedom from valve reintervention was 97.0% for TAVR and 98.9% for SAVR (p = 0.04). A permanent pacemaker was implanted in 33.0% of TAVR and 19.8% of SAVR patients at 5 years. CONCLUSIONS: This study shows similar mid-term survival and stroke rates in high-risk patients following TAVR or SAVR. Severe structural valve deterioration and valve reinterventions were uncommon. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902).


Assuntos
Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/cirurgia , Stents Metálicos Autoexpansíveis/tendências , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/tendências , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Mortalidade/tendências , Estudos Prospectivos , Fatores de Risco , Stents Metálicos Autoexpansíveis/efeitos adversos , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
16.
Curr Cardiol Rep ; 20(10): 101, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30173390

RESUMO

PURPOSE: This paper reviews the double-kiss crush (DK crush) technique in coronary artery bifurcation lesions. The technical aspects of the procedure and the clinical data supporting its use are summarized. RECENT FINDINGS: Randomized studies support the adoption of DK technique in complex bifurcation lesions for both left main and non-left-main lesions. For true bifurcation lesions, DK crush may become the default technique for lesions in which the side-branch disease is complex and long. Optimal technique is essential for obtaining the clinical outcomes noted in the DKCRUSH randomized studies.


Assuntos
Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/métodos , Stents , Angioplastia Coronária com Balão/métodos , Angiografia Coronária , Reestenose Coronária/cirurgia , Estenose Coronária/cirurgia , Stents Farmacológicos , Humanos , Infarto do Miocárdio/cirurgia , Revascularização Miocárdica , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Tempo , Resultado do Tratamento
17.
Am J Cardiol ; 121(11): 1358-1364, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29680171

RESUMO

The impact of predilatation (Pre-Dil) on prosthesis hemodynamics and clinical outcomes of subjects who underwent transcatheter aortic valve implantation (TAVI) with a self-expanding prosthesis remains unclear. Two thousand seven hundred twenty-one subjects from the extreme- and high-risk CoreValve Continued Access Study (CAS) were included in the analysis. Subjects who underwent Pre-Dil before TAVI were compared with subjects who underwent TAVI without Pre-Dil. Clinical outcomes included death, stroke, myocardial infarction, acute kidney injury, and new permanent pacemaker implantation. Serial echocardiograms were analyzed to evaluate prosthesis hemodynamics, specifically paravalvular regurgitation, effective orifice area, and mean gradient. Two thousand one hundred eighteen and 603 subjects underwent TAVI with and without Pre-Dil, respectively. Subjects in the Pre-Dil cohort were more commonly male, while subjects in the no Pre-Dil cohort had higher rates of previous stroke and lower mean aortic valve gradients. Outcomes at 30 days were comparable between Pre-Dil and no Pre-Dil subjects, with no significant difference in mortality (5.5% vs 4.3%, p = 0.27), major stroke (2.6% vs 2.2%, p = 0.54), major vascular complications (6.9% vs 8.0%, p = 0.37), major bleeding (24.4% vs 26.1%, p = 0.40), and permanent pacemaker implantation (21.3% vs 23.4%, p = 0.36). There were no significant differences in the same outcomes at 12 months. Effective orifice area and mean gradient were comparable between Pre-Dil and no-Pre-Dil subjects at discharge, at 30 days, and at 12 months. In conclusion, when performing TAVI with the self-expanding CoreValve device, performing direct implantation without Pre-Dil maintains an acceptable safety profile and still achieves desired and consistent prosthesis hemodynamics.


Assuntos
Estenose da Valva Aórtica/cirurgia , Dilatação/métodos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Injúria Renal Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Ecocardiografia , Feminino , Hemodinâmica , Humanos , Masculino , Mortalidade , Infarto do Miocárdio/epidemiologia , Marca-Passo Artificial , Índice de Gravidade de Doença , Acidente Vascular Cerebral/epidemiologia , Resultado do Tratamento
18.
J Thorac Cardiovasc Surg ; 153(6): 1293-1301.e1, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28249691

RESUMO

OBJECTIVE: Explore causes and timing of death from the CoreValve US Pivotal High-Risk Trial. METHODS: An independent clinical events committee adjudicated causes of death, followed by post hoc hierarchical classification. Baseline characteristics, early outcomes, and causes of death were evaluated for 3 time periods (selected based on threshold of surgical 30-day mortality and on the differences in the continuous hazard between the 2 groups): early (0-30 days), recovery (31-120 days), and late (121-365 days). RESULTS: Differences in the rate of death were evident only during the recovery period (31-120 days), whereas 15 patients undergoing transcatheter aortic valve replacement (TAVR) (4.0%) and 27 surgical aortic valve replacement (SAVR) patients (7.9%) died (P = .025). This mortality difference was largely driven by higher rates of technical failure, surgical complications, and lack of recovery following surgery. From 0 to 30 days, the causes of death were more technical failures in the TAVR group and lack of recovery in the SAVR group. Mortality in the late period (121-365 days) in both arms was most commonly ascribed to other circumstances, comprising death from medical complications from comorbid disease. CONCLUSIONS: Mortality at 1 year in the CoreValve US Pivotal High-Risk Trial favored TAVR over SAVR. The major contributor was that more SAVR patients died during the recovery period (31-121 days), likely affected by the overall influence of physical stress associated with surgery. Similar rates of technical failure and complications were observed between the 2 groups. This suggests that early TAVR results can improve with technical refinements and that high-risk surgical patients will benefit from reducing complications.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/mortalidade , Estudos Multicêntricos como Assunto/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos , Projetos de Pesquisa , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Animais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Causas de Morte , Comorbidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Sus scrofa , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estados Unidos
20.
Coron Artery Dis ; 28(1): 77-89, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27561169

RESUMO

Although current everolimus-eluting coronary stents have shown improved event-free survival within the first year following implantation compared with bare-metal stents or earlier generation drug-eluting stents, they remain associated with an ongoing risk for adverse outcomes (thrombosis, myocardial infarction, and restenosis) beyond 1 year at rates similar to those observed following bare-metal stent deployment. This ongoing very late hazard has been attributed to the permanent presence of the metal frame and/or polymer in these stents. The Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb BVS) has been developed to provide mechanical support and drug-delivery functions similar to metallic drug-eluting stents, followed by complete resorption with recovery of more normal vascular structure and function, thus avoiding the limitations associated with permanent metallic endovascular prostheses. Absorb BVS has shown safety and efficacy in the dedicated clinical trial development program of Abbott Vascular and in an array of investigator-sponsored studies involving a broad spectrum of clinical (patient) as well as coronary anatomic complexity. Longer-term evidence, largely limited to single-arm studies, appears to reflect durable safety and efficacy and suggests Absorb BVS to be an attractive therapeutic option. Interim evidence from a series of randomized-clinical trials (RCTs) comparing Absorb BVS with the Xience cobalt-chromium metallic everolimus-eluting stent has shown noninferiority of Absorb BVS with respect to target lesion failure (composite occurrence of cardiac death, target vessel-related myocardial infarction, and ischemia-driven target lesion revascularization) beyond the first year, with no statistically significant differences in other safety/efficacy measures. However, concerns do exist in terms of increased rates of scaffold thrombosis, the risk for which may be mitigated by improved patient and lesion selection, procedural technique, and device iteration. We provide an overview of the evolution of percutaneous coronary intervention, in-vivo characterization of Absorb BVS resorption, and a summary with a critical evaluation of available evidence from RCTs, pooled analyses, and meta-analyses of RCTs for the safety and efficacy of Absorb BVS obtained primarily following the treatment of noncomplex coronary lesions in patients with stable ischemic heart disease and/or stabilized acute coronary syndromes.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/instrumentação , Ensaios Clínicos Controlados Aleatórios como Assunto , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/etiologia , Estenose Coronária/etiologia , Medicina Baseada em Evidências , Humanos , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA