Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Rev Gastroenterol Mex (Engl Ed) ; 86(4): 348-355, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34272192

RESUMO

INTRODUCTION AND AIMS: The adenoma detection rate (ADR) is the most important quality indicator for the prevention of colorectal cancer but serrated polyps are also precursor lesions of the disease. The aim of our study was to compare the detection rate of proximal serrated polyps (PSPs) and that of clinically significant serrated polyps (CSSPs) between endoscopists and analyze the relation of those parameters to the ADR. METHODS: An observational, prospective, cross-sectional study was conducted on all patients that underwent colonoscopy at the Policlínico Peruano Japonés within the time frame of July 2015 and August 2016. The ADR and PSP and CSSP detection rates between endoscopists were compared through multivariate logistic regression and the association between those parameters was calculated through the Pearson correlation coefficient. RESULTS: The study included 15 endoscopists and 1,378 colonoscopies. The PSP detection rate ranged from 1.8-17% between endoscopists and had an almost perfect correlation with the CSSP detection rate (p = 0.922), as well as strongly correlating with the ADR (p = 0.769). CONCLUSIONS: There was great variability in the PSP detection rate between endoscopists. It also had an almost perfect correlation with the CSSP detection rate and strongly correlated with the ADR. Those results suggest a high CSSP miss rate at endoscopy and a low PSP detection rate.


Assuntos
Pólipos do Colo , Neoplasias Colorretais , Pólipos do Colo/diagnóstico , Colonoscopia , Neoplasias Colorretais/diagnóstico , Estudos Transversais , Humanos , Estudos Prospectivos
2.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32868136

RESUMO

INTRODUCTION AND AIMS: The adenoma detection rate (ADR) is the most important quality indicator for the prevention of colorectal cancer but serrated polyps are also precursor lesions of the disease. The aim of our study was to compare the detection rate of proximal serrated polyps (PSPs) and that of clinically significant serrated polyps (CSSPs) between endoscopists and analyze the relation of those parameters to the ADR. METHODS: An observational, prospective, cross-sectional study was conducted on all patients that underwent colonoscopy at the Policlínico Peruano Japonés within the time frame of July 2015 and August 2016. The ADR and PSP and CSSP detection rates between endoscopists were compared through multivariate logistic regression and the association between those parameters was calculated through the Pearson correlation coefficient. RESULTS: The study included 15 endoscopists and 1,378 colonoscopies. The PSP detection rate ranged from 1.8-17% between endoscopists and had an almost perfect correlation with the CSSP detection rate (p = 0.922), as well as strongly correlating with the ADR (p = 0.769). CONCLUSIONS: There was great variability in the PSP detection rate between endoscopists. It also had an almost perfect correlation with the CSSP detection rate and strongly correlated with the ADR. Those results suggest a high CSSP miss rate at endoscopy and a low PSP detection rate.

3.
J Biomed Mater Res A ; 102(6): 2008-16, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23853101

RESUMO

In this work, the effect of pulsed laser melting on the exhibited microstructure and properties of a cast Co-27Cr-5Mo-0.25C alloy was investigated. In particular, properties such as surface hardness and wear behavior of the laser modified microstructure were determined as a function of the implemented laser melting parameters. It was found that laser melting promotes significant grain refinement while preventing the precipitation of coarse carbide phases. Apparently, a refined dendritic grain structure develops which is surrounded by a fine carbide distribution in the interdendritic regions. Moreover, the high-temperature face centered cubic (FCC) phase remains untransformed at room temperature. Hardness measurements and wear testing using a Pin-On-Disk tribological machine indicate that the modified laser surfaces exhibit both, high wear resistance and high microhardness when compared with the untreated as-cast Co-27Cr-5Mo-0.25C alloy. In particular, it was found that the laser modified surfaces exhibit improved wear and friction properties comparable to the ones found in Co-Cr-Mo alloys with a predominantly hexagonal closest packed (HCP) matrix. However, surface defects associated with the laser process can be detrimental for the improved wear performance and they should be considered in identifying the proper laser parameters in alloy melting.


Assuntos
Materiais Biocompatíveis/química , Ligas de Cromo/química , Cobalto/química , Molibdênio/química , Dureza , Temperatura Alta , Lasers , Teste de Materiais , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA