Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Spine J ; 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649486

RESUMO

PURPOSE: Barbed sutures are tissue control devices that can reduce operating room time and costs. We analyzed the utility of barbed sutures in posterior spinal surgery in order to prove non-inferiority to conventional methods for wound closure. METHODS: A cohort of patients undergoing elective posterior spinal surgery in which barbed (prospective) versus conventional sutures (retrospective) were used was analyzed. The primary endpoint was the occurrence of wound healing complications or the need for surgical revision. Secondary endpoints included postoperative stay, readmission rate, and duration and cost of wound closure. RESULT: A total of 483 patients participated in the study, 183 in the Barbed group and 300 in the Conventional group. Wound dehiscence or seroma occurred in 3.8% and 2.7% of the Barbed and Conventional groups, respectively (p = 0.6588). Both superficial (1.6% versus 4.0%, P = 0.2378) and deep infections (2.7% versus 4.7%, p = 0.4124) occurred similarly in both groups. Overall, the rate of re-intervention due to wound healing problems was also similar (4.9% versus 5.3%, p = 0.9906), as well as, total median hospital stay, postoperative stay and 30-day re-admission rates. The average duration of wound closure (1.66 versus 4.16 min per level operated, p < 0.0001) strongly favored the Barbed group. The mean cost of wound closure per patient was higher in the Barbed group (43.23 € versus 22.67 €, p < 0.0001). CONCLUSIONS: In elective posterior spinal procedures, the use of barbed sutures significantly reduced the duration of wound closure. The wound healing process was not hindered and the added cost related to the suture material was small.

2.
Neurocirugia (Astur : Engl Ed) ; 31(2): 64-75, 2020.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31611139

RESUMO

OBJECTIVE: To assess the effectiveness and safety of vancomycin powder as surgical site infection (SSI) prophylaxis in posterior bilateral elective spinal surgery. MATERIALS AND METHODS: Single-center quasi-experimental pre and postintervention comparative cohort study. The post-intervention group received standard intravenous antibiotic prophylaxis plus 1g of vancomycin powder into the surgical field before wound closure, and the pre-intervention group only the intravenous prophylaxis. RESULTS: 150 patients were included in each group. Twelve SSI (7 superficial and 5 deep) occurred in the post-intervention group and 16 SSI (7 superficial and 9 deep) in the pre-intervention group. The risk of deep SSI decreased from 6.0% to 3.3% (OR 0,54, 95%CI 0.17-1.65, p=0.411) with vancomycin powder. The percentage of deep SSI due to gram negative-positive germs were 80%-20% and 33%-67% for the post- and pre-intervention groups, respectively (p=0.265). No local or systemic adverse effects occurred attributable to vancomycin powder. CONCLUSION: In posterior elective spinal surgery, prophylaxis with vancomycin powder did not result in a significantly reduced incidence of superficial and deep SSI. There was a trend towards a higher incidence of deep SSI caused by gram negative microorganisms among those treated with vancomycin.


Assuntos
Infecção da Ferida Cirúrgica , Vancomicina , Antibacterianos/uso terapêutico , Antibioticoprofilaxia , Estudos de Coortes , Humanos , Pós/uso terapêutico , Estudos Retrospectivos , Infecção da Ferida Cirúrgica/tratamento farmacológico , Infecção da Ferida Cirúrgica/prevenção & controle , Vancomicina/uso terapêutico
3.
Neurocirugia (Astur : Engl Ed) ; 29(4): 187-200, 2018.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29636275

RESUMO

OBJECTIVE: To describe pros and cons of some radiation protection measures and the implications on the design of a neurosurgery operating room. MATERIAL AND METHODS: Concurring with the acquisition and use of an O-arm device, a structural remodeling of our neurosurgery operating room was carried out. The theater was enlarged, the shielding was reinforced and a foldable leaded screen was installed inside the operating room. Radiation doses were measured in front of and behind the screen. RESULTS: The screen provides whole-body radiation protection for all the personnel inside the theater (effective dose <5µSv at 2,5 m from the gantry per O-arm exploration; 0,0µSv received behind the screen per O-arm exploration; and undetectable cumulative annual radiation dose behind the screen), obviates the need for leaded aprons and personal dosimeters, and minimizes the circulation of personnel. Enlarging the size of the operating room allows storing the equipment inside and minimizes the risk of collision and contamination. Rectangular rooms provide greater distance from the source of radiation. CONCLUSION: Floor, ceiling and walls shielding, a rectangular-shaped and large enough theater, the presence of a foldable leaded screen, and the security systems precluding an unexpected irruption into the operating room during irradiation are relevant issues to consider when designing a neurosurgery operating theater.


Assuntos
Arquitetura Hospitalar , Procedimentos Neurocirúrgicos , Traumatismos Ocupacionais/prevenção & controle , Salas Cirúrgicas , Lesões por Radiação/prevenção & controle , Proteção Radiológica , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA