Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Minerva Anestesiol ; 88(3): 121-128, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34527406

RESUMO

BACKGROUND: Double-lumen endobronchial tubes (DLT) continue to be the most widely used method for obtaining lung isolation during anesthesia. We compared recommendations for DLT size selection with radiologically assessed lower airway dimensions gathered from a large patient population. METHODS: For this retrospective comparative study, we assessed computed tomography (CT) scans of 150 adults with no known airway pathologies. Using these scans, we measured the diameter and length of the trachea and the diameter of the mainstem bronchi. These airway dimensions were then compared to the dimensions of left-sided DLTs of three different manufacturers. Size selection was based on one standard textbook's recommendations. RESULTS: We found the recommended DLT sizes were occasionally too small but more often too large, particularly in the endobronchial airway. With the DLT Vivasight-DL®, mismatching occurred in 28.7% (43/150) of the patients at the distal mainstem bronchus and 8% (12/150) at the tracheal level. This mismatching happened most often in females (left distal mainstem bronchus 34/68, 50%; trachea 9/68, 13.2%). Conversely, the DLT was more often too small for male patients in both the left main bronchus (SHER-I-BRONCH®: 8/82, 9.8%) and the trachea (SHER-I-BRONCH®: 2/82, 2.4%). The endobronchial tube portion was more often too long in females (Vivasight® DLT: 11/68, 16%) than males (9/82, 11%). CONCLUSIONS: A considerable proportion of the recommended DLT sizes from all three manufacturers was incompatible with individual patient's lower airway dimensions.


Assuntos
Intubação Intratraqueal , Traqueia , Adulto , Brônquios/diagnóstico por imagem , Feminino , Humanos , Intubação Intratraqueal/métodos , Pulmão , Masculino , Estudos Retrospectivos , Traqueia/diagnóstico por imagem
2.
Artigo em Alemão | MEDLINE | ID: mdl-26147408

RESUMO

In a 20-year old parturient general anesthesia is induced by inhalation and without venous access because of severe needle phobia. This article discusses risks associated with inhalational induction of anesthesia in this special situation. It deals with needle phobia, an anxiety disorder belonging to the group of blood-injury-injection phobia. This psychic illness can cause severe problems for the anaesthetic management in acute or in elective situations.


Assuntos
Anestesia por Inalação/psicologia , Cesárea/efeitos adversos , Cesárea/psicologia , Agulhas/efeitos adversos , Transtornos Fóbicos/psicologia , Complicações na Gravidez/psicologia , Feminino , Humanos , Aceitação pelo Paciente de Cuidados de Saúde/psicologia , Transtornos Fóbicos/etiologia , Gravidez , Complicações na Gravidez/diagnóstico , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA