Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Forensic Sci ; 68(6): 2205-2210, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37658657

RESUMO

Xylazine sedative, muscle relaxant, and analgesic used in a veterinary setting. Although xylazine was never approved for therapeutic use in humans, it has become popular in the street drug market as a cutting or bulking agent in the fentanyl and heroin supply. Recently, there has been a significant increase in the detection of xylazine in postmortem forensic toxicology casework. Xylazine can be identified during routine toxicology screening utilizing instrumentation such as gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry. Using the Miami-Dade Medical Examiner's LIMS system, all cases received between 2015 and 2022 in which xylazine was reported were reviewed. The cases studied include accidental drug overdose deaths in Miami-Dade County as well as Collier County (Naples), Florida. In total, there are 170 cases; the majority are accidental polydrug overdoses involving White males between the ages of 25 and 44 years old. Of the 170 cases, 37% listed xylazine as the cause of death. 13% of cases contained only xylazine and fentanyl while the remaining 87% of deaths were attributed to polydrug toxicity involving two or more substances. The prevalence of xylazine can be attributed to its increasing popularity rather than an increase in caseload. In 2019, xylazine was present in only 4% of all accidental fentanyl overdoses. By 2021, this percentage has increased sixfold, with xylazine present in 24% of all accidental fentanyl overdoses. Despite a decrease in fentanyl overdoses in 2022, the percentage of xylazine detection remained the same.


Assuntos
Depressores do Sistema Nervoso Central , Overdose de Drogas , Masculino , Humanos , Adulto , Xilazina , Médicos Legistas , Prevalência , Florida/epidemiologia , Fentanila/análise , Overdose de Drogas/epidemiologia , Analgésicos Opioides/análise
2.
J Anal Toxicol ; 45(8): 885-891, 2021 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34107045

RESUMO

Carbon monoxide (CO) poisoning presents an interesting challenge for postmortem toxicology laboratories. The discontinuation of the CO-oximeter manufactured by Instrumentation Laboratories has left many forensic laboratories without this simple but reliable choice for the analysis of CO in blood. A comparable alternative that is quick and simple is analysis using a standard ultraviolet-visible spectrophotometer, which offers sufficient precision and accuracy for the measurement of percentage carboxyhemoglobin (%COHb) in postmortem blood. The hurdle for laboratories then becomes the selection of an appropriate spectrophotometric method since a variety of procedures have been published over the years. Four methods were evaluated based on literature findings and/or the appropriateness for postmortem testing. These methods are based on (i) relating %COHb to the ratio of COHb and Hb absorbance of a two-component system (two wavelengths), (ii) the multicomponent analysis of all hemoglobin species, (iii) the multicomponent analysis of a two-component system, and (iv) derivative spectroscopy. While all four methods performed similarly in terms of typical validation requirements, the ability to more effectively handle decomposed samples and the ease of sample preparation afforded (v) the multicomponent analysis of a two-component system-the most suitable for routine postmortem testing.


Assuntos
Intoxicação por Monóxido de Carbono , Carboxihemoglobina , Autopsia , Intoxicação por Monóxido de Carbono/diagnóstico , Carboxihemoglobina/análise , Medicina Legal , Humanos , Espectrofotometria
3.
J Anal Toxicol ; 2020 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-33305793

RESUMO

N-ethylpentylone (NEP, ephylone, bk-EBDP) was the most prevalent synthetic cathinone detected by the Miami-Dade Medical Examiner Toxicology Laboratory from 2016-2018. There is limited information regarding the toxicity of NEP, however the few published reports suggest that NEP can cause serious toxic effects and sudden death. The purpose of this publication is to describe a validated LC-MS/MS method for seven synthetic cathinones (methylone, ethylone, butylone, dibutylone, α-PVP, pentylone, and NEP) and to present a detailed summary regarding the presence of NEP in postmortem casework at the Miami-Dade Medical Examiner Department. Post-mortem iliac blood, serum, liver, and brain specimens were prepared by solid-phase extraction with analysis by ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS-MS). Analyte linearity was established from 0.01 to 0.5 mg/L on a six-point calibration curve. A total of 101 NEP quantitations were performed using this method. Concentrations in postmortem case samples ranged from 0.01 mg/L to 2.7 mg/L. Iliac blood concentrations averaged 0.312 mg/L with a median of 0.137 mg/L (n=72) across all causes and manners of death. Approximately half of the cases were homicides in which the decedent was the victim of gunshot wounds or stabbing. Two of the three highest concentration cases of NEP (2.7 mg/L and 1.7 mg/L) involved 38-year old white males who were tasered by police prior to death. The psychostimulant effect of NEP may result in an excited delirium and/or hallucinogenic state. The concentration of NEP detected in accidental intoxication and polydrug cases overlapped with those attributed to other causes, including homicides and police involved deaths.

4.
J Anal Toxicol ; 43(8): 666-672, 2019 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-31424072

RESUMO

The (±)-threo-4-fluoromethylphenidate (4F-MPH) is a fluorinated analog of the prescription central nervous system stimulant medication, methylphenidate. This novel psychoactive substance was first detected in drug paraphernalia at the Miami-Dade County Medical Examiner Department Toxicology Laboratory in 2016 but was not detected in a biological specimen until 2018. Limited literature is available on 4F-MPH, with predominate literature being published out of Europe, and no known toxicities reported in the USA. Post-mortem specimens were screened using both gas chromatography mass spectrometry and liquid chromatography ion trap mass spectrometry (LC-Ion Trap-MSn). In addition, a validated method for the quantification of 4F-MPH was developed using liquid chromatography-tandem mass spectrometry (LC-MS-MS), with a linear range of 0.01-0.500 mg/L and acceptable validation criteria including precision, bias, carry-over, linearity and endogenous/exogenous interferences. In addition to the detection of 4F-MPH, 3-methoxy-PCP, amphetamine, methamphetamine, 6-monoacetylmorphine, morphine, codeine and tetrahydrocannabinol were also identified in the decedent. A single source of blood was collected (femoral vein) and quantified in all blood tubes used for collection, with concentrations varying from 0.012 to 0.05 mg/L. Additional specimens available for screening included gastric contents and urine. An additional peak having the same targeted ions and transitions as 4F-MPH was identified in both the LC-Ion Trap-MSn screening procedure and the LC-MS-MS quantitative procedure. This peak suggests the presence of a structural isomer, possibly (±)-erythro-4-fluoromethylphenidate, which cannot be confirmed due to there being no available certified reference material. This case report presents the first time that 4F-MPH was detected in a decedent, as well as the first time 4F-MPH has been listed in the official cause of death of a decedent in Florida.


Assuntos
Estimulantes do Sistema Nervoso Central/análise , Estimulantes do Sistema Nervoso Central/toxicidade , Toxicologia Forense , Metilfenidato/análogos & derivados , Transtornos Relacionados ao Uso de Substâncias/diagnóstico , Adulto , Cromatografia Líquida de Alta Pressão , Evolução Fatal , Humanos , Masculino , Metilfenidato/análise , Metilfenidato/toxicidade , Reprodutibilidade dos Testes , Manejo de Espécimes , Espectrometria de Massas em Tandem
5.
J Forensic Sci ; 64(1): 314-317, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29772071

RESUMO

A case demonstrating the necessity of thorough death investigation processes where toxicology plays an active role is presented. A 33-year-old white man presented to the emergency room in respiratory distress after an overdose episode where he was revived on the scene by fire rescue. His condition continued to deteriorate and he expired 6 days after the initial incident. No admission specimens were available for testing; however, there were specimens drawn 4 and 5 days after the incident. Drug paraphernalia from the scene was obtained by the laboratory through collaboration with local law enforcement. Drug paraphernalia was initially tested in the laboratory and after obtaining the results, the antemortem and postmortem specimens were tested identifying mitragynine and U-47700, among other drugs. These results indicate the value in obtaining and testing drug paraphernalia, and the value of testing antemortem specimens even in the event of a delay.


Assuntos
Overdose de Drogas/diagnóstico , Drogas Ilícitas/análise , Transtornos Relacionados ao Uso de Substâncias/diagnóstico , Injúria Renal Aguda/induzido quimicamente , Adulto , Toxicologia Forense , Humanos , Drogas Ilícitas/farmacocinética , Masculino , Síndrome do Desconforto Respiratório/induzido quimicamente , Transtornos Relacionados ao Uso de Substâncias/complicações , Fatores de Tempo , Distribuição Tecidual
6.
J Anal Toxicol ; 42(8): 570-580, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30371841

RESUMO

Since 2013, opioid-related deaths have increased in Miami-Dade County, FL due to fentanyl and fentanyl analogs in the local heroin supply. From 2014 to 2015, a near 600% increase in fentanyl and fentanyl analog-related deaths was observed, followed by another 200% increase in 2016. In addition to fentanyl, six fentanyl analogs were identified in this time period: ß-hydroxythiofentanyl, acetyl fentanyl, furanyl fentanyl, carfentanil, butyryl fentanyl and para-fluoroisobutyryl fentanyl. As a result, an analytical method to quantify these compounds in postmortem biological fluids and tissues using solid-phase extraction with analysis by ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS-MS) was developed and validated. All analytes except carfentanil were linear from 1 to 50 ng/mL with a limit of detection (LOD) of 0.5 ng/mL; carfentanil was linear from 0.2 to 10 ng/mL with a LOD of 0.1 ng/mL. For all analytes, bias was within ±14%, intra- and inter-day precision were ≤5% and extraction efficiency was >87%. Dilution integrity was assessed at 1:1, 1:4 and 1:9 (v/v) ratios; percent error from target was <12% for all analytes. No exogenous interferences were observed. Analytes were stable in preserved whole blood stored at 4°C for 9 months; extracted samples were stable in the refrigerated autosampler (15°C) for up to 72 h. The ability to distinguish the isomer pairs isobutyryl/butyryl fentanyl and p-fluoroisobutyryl/p-fluorobutyryl fentanyl is achieved by this method. The method was applied to 312 cases in which fentanyl and/or fentanyl analogs were previously identified. Postmortem concentrations in blood ranged from <0.2 to 0.73 ng/mL for carfentanil and from 30.6 to 91.7 ng/mL for p-fluoroisobutyryl fentanyl in cases in which these analytes were listed as the sole cause of death.


Assuntos
Fentanila/análogos & derivados , Fentanila/análise , Toxicologia Forense/métodos , Drogas Ilícitas/análise , Detecção do Abuso de Substâncias/métodos , Cromatografia Líquida de Alta Pressão , Toxicologia Forense/instrumentação , Humanos , Limite de Detecção , Mudanças Depois da Morte , Reprodutibilidade dos Testes , Extração em Fase Sólida , Detecção do Abuso de Substâncias/instrumentação , Espectrometria de Massas em Tandem
7.
J Anal Toxicol ; 41(6): 484-492, 2017 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-28633314

RESUMO

Since 2013, the Miami-Dade County Medical Examiner Department has experienced an increase in the number of opioid-related deaths. The majority of cases coincided with the introduction of fentanyl into the local heroin supply. From 2014 to 2015, Miami-Dade County experienced a near 600% increase in fentanyl-related deaths, followed by an additional 200% increase in 2016. In 2015, two novel fentanyl analogs were identified in medical examiner cases: beta-hydroxythiofentanyl and acetyl fentanyl. In 2016, four additional fentanyl analogs emerged: para-fluoroisobutyryl fentanyl, butyryl fentanyl, furanyl fentanyl and carfentanil, as well as the synthetic opioid U-47700. In order to address this epidemic, a method was developed and validated to identify 44 opioid-related and analgesic compounds in postmortem samples using ultra high performance liquid chromatography ion trap mass spectrometry with MSn capabilities. The limit of detection for all compounds ranged from 0.1 to 5 ng/mL, with a majority having MS3 spectral fragmentation. Blood, urine, liver or brain specimens from ~500 postmortem cases were submitted for analysis based on case history and/or initial screening results. Of those cases, 375 were positive for illicit fentanyl and/or one or more fentanyl analogs. Due to the potency of these compounds, they were almost always included in the cause of death. Worth emphasizing and extremely alarming is the detection of carfentanil in 134 cases, 104 of which were initially missed by gas chromatography mass spectrometry. By incorporating this sensitive, highly specific, and evolving screening procedure into the workflow, the toxicology laboratory continues to effectively assist the medical examiners in determining the cause and manner of death of decedents in Miami-Dade County.


Assuntos
Analgésicos Opioides/análise , Cromatografia Líquida de Alta Pressão/métodos , Fentanila/análise , Detecção do Abuso de Substâncias/métodos , Autopsia , Overdose de Drogas , Toxicologia Forense , Humanos
8.
J Anal Toxicol ; 29(5): 394-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16105268

RESUMO

In February 2003, the Miami-Dade County Medical Examiner Department reported the first known death in the country related to alpha-methyltryptamine (AMT). AMT is an indole analogue of amphetamine investigated in the 1960s as an antidepressant, stimulant, and monoamine oxidase inhibitor. Today, AMT is recognized as a powerful psychedelic drug among high school and college-aged men and women. Its popularity is partly due to the multitude of anecdotal websites discussing AMT as well as its legality and availability for purchase via the Internet prior to April 2003. Emergency designation of AMT as a Schedule 1 controlled substance by the Drug Enforcement Administration occurred shortly after the death in Miami-Dade County. The case in Miami involved a young college student who, prior to death, advised his roommate that he was "taking hallucinating drugs" and as a result had "discovered the secret of the universe". Approximately 12 h later, the roommate discovered the deceased lying in bed unresponsive. An empty 1-g vial of AMT was recovered from the scene and sent to the toxicology laboratory. Initial screening of urine by enzyme-multiplied immunoassay technique was positive for amphetamines, and the basic drug blood screen detected a small peak later identified by mass spectrometry as AMT. For quantitation, AMT was isolated using solid-phase extraction, derivatized with pentafluoropropionic anhydride, and analyzed using gas chromatography-mass spectrometry. Quantitative analysis was based upon m/z 276, 303, and 466 for AMT and m/z 306, 333, and 496 for the internal standard, 5-methoxy-alpha-methyltryptamine. A linear calibration curve from 50 to 500 ng/mL was used to calculate the concentration of AMT in the samples and controls. Blood, tissue, and gastric specimens were diluted to bring the observed concentration within the limits of the standard curve. Matrix matched controls were extracted and analyzed with each run. Postmortem iliac vein blood revealed 2.0 mg/L, gastric contents (48 g collected at autopsy) contained 9.6 mg total of AMT, liver contained 24.7 mg/kg, and the brain contained 7.8 mg/kg. An additional Medical Examiner case from another jurisdiction revealed 1.5 mg/L in antemortem serum.


Assuntos
Química Encefálica , Alucinógenos/intoxicação , Triptaminas/intoxicação , Adulto , Overdose de Drogas , Evolução Fatal , Cromatografia Gasosa-Espectrometria de Massas , Conteúdo Gastrointestinal/química , Alucinógenos/sangue , Alucinógenos/urina , Humanos , Veia Ilíaca , Fígado/química , Masculino , Distribuição Tecidual , Triptaminas/análise , Triptaminas/sangue , Triptaminas/urina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA