Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Resuscitation ; 119: 81-88, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28800887

RESUMO

AIM OF THE STUDY: The purpose of this study was to examine continuous oxygen insufflation (COI) in a swine model of cardiac arrest. The primary hypothesis was COI during standard CPR (S-CPR) should result in higher intrathoracic pressure (ITP) during chest compression and lower ITP during decompression versus S-CPR alone. These changes with COI were hypothesized to improve hemodynamics. The second hypothesis was that changes in ITP with S-CPR+COI would result in superior hemodynamics compared with active compression decompression (ACD) + impedance threshold device (ITD) CPR, as this method primarily lowers ITP during chest decompression. METHODS: After 6min of untreated ventricular fibrillation, S-CPR was initiated in 8 female swine for 4min, then 3min of S-CPR+COI, then 3min of ACD+ITD CPR, then 3min of S-CPR+COI. ITP and hemodynamics were continuously monitored. RESULTS: During S-CPR+COI, ITP was always positive during the CPR compression and decompression phases. ITP compression values with S-CPR+COI versus S-CPR alone were 5.5±3 versus 0.2±2 (p<0.001) and decompression values were 2.8±2 versus -1.3±2 (p<0.001), respectively. With S-CPR+COI versus ACD+ITD the ITP compression values were 5.5±3 versus 1.5±2 (p<0.01) and decompression values were 2.8±2 versus -4.7±3 (p<0.001), respectively. CONCLUSION: COI during S-CPR created a continuous positive pressure in the airway during both the compression and decompression phase of CPR. At no point in time did COI generate a negative intrathoracic pressures during CPR in this swine model of cardiac arrest.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Parada Cardíaca/terapia , Massagem Cardíaca/métodos , Insuflação/métodos , Intubação Intratraqueal/instrumentação , Fibrilação Ventricular/terapia , Animais , Gasometria , Reanimação Cardiopulmonar/efeitos adversos , Reanimação Cardiopulmonar/métodos , Modelos Animais de Doenças , Feminino , Parada Cardíaca/fisiopatologia , Intubação Intratraqueal/efeitos adversos , Suínos
2.
Resuscitation ; 121: 195-200, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28827197

RESUMO

AIM OF THE STUDY: As most cardiopulmonary resuscitation (CPR) efforts last longer than 15min, the aim of this study was to compare brain blood flow between the Head Up (HUP) and supine (SUP) body positions during a prolonged CPR effort of 15min, using active compression-decompression (ACD) CPR and impedance threshold device (ITD) in a swine model of cardiac arrest. METHODS: Ventricular fibrillation (VF) was induced in anesthetized pigs. After 8min of untreated VF followed by 2min of ACD-CPR+ITD in the SUP position, pigs were randomized to 18min of continuous ACD-CPR+ITD in either a 30° HUP or SUP position. Microspheres were injected before VF and then 5 and 15min after start of CPR. RESULTS: The mean blood flow (ml/min/g, mean±SD) to the brain after 15min of CPR was 0.42±0.05 in the HUP group (n=8) and 0.21±0.04 SUP (n=10), respectively, (p<0.01). The HUP group also had statistically significantly lower intracranial pressures and higher calculated cerebral perfusion pressures after 5, 15, 19 (before adrenaline) and 20 (after adrenaline) minutes of HUT versus SUP CPR. CONCLUSIONS: After prolonged ACD-CPR+ITD in the HUP position, brain blood flow was 2-fold higher versus the SUP position. These positive findings provide strong pre-clinical support to proceed with a clinical evaluation of elevation of the head and thorax during ACD-CPR+ITD in humans in cardiac arrest.


Assuntos
Reanimação Cardiopulmonar/instrumentação , Circulação Cerebrovascular/fisiologia , Parada Cardíaca/fisiopatologia , Parada Cardíaca/terapia , Hemodinâmica/fisiologia , Postura , Animais , Encéfalo/fisiopatologia , Modelos Animais de Doenças , Cabeça , Humanos , Distribuição Aleatória , Suínos , Tórax , Fatores de Tempo
3.
Resuscitation ; 116: 56-59, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28461164

RESUMO

INTRODUCTION: Chest compliance plays a fundamental role in the generation of circulation during cardiopulmonary resuscitation (CPR). To study potential changes in chest compliance over time, anterior posterior (AP) chest height measurements were performed on newly deceased (never frozen) human cadavers during CPR before and after 5min of automated CPR. We tested the hypothesis that after 5min of CPR chest compliance would be significantly increased. METHODS: Static compression (30, 40, and 50kg) and decompression forces (-10, -15kg) were applied with a manual ACD-CPR device (ResQPUMP, ZOLL) before and after 5min of automated CPR. Lateral chest x-rays were obtained with multiple reference markers to assess changes in AP distance. RESULTS: In 9 cadavers, changes (mean±SD) in the AP distance (cm) during the applied forces were 2.1±1.2 for a compression force of 30kg, 2.9±1.3 for 40kg, 4.3±1.0 for 50kg, 1.0±0.8 for a decompression force of -10kg and 1.8±0.6 for -15kg. After 5min of automated CPR, AP excursion distances were significantly greater (p<0.05). AP distance increased to 3.7±1.4 for a compression force of 30kg, 4.9±1.6 for 40kg, 6.3±1.9 for 50kg, 2.3±0.9 for -10kg of lift and 2.7±1.1 for -15kg of lift. CONCLUSIONS: These data demonstrate chest compliance increases significantly over time as demonstrated by the significant increase in the measured AP distance after 5min of CPR. These findings suggest that adjustments in compression and decompression forces may be needed to optimize CPR over time.


Assuntos
Reanimação Cardiopulmonar/instrumentação , Descompressão , Complacência Pulmonar/fisiologia , Pressão , Cadáver , Feminino , Parada Cardíaca/terapia , Humanos , Masculino , Parede Torácica/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA