Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Neuroradiol ; 49(1): 9-16, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34023361

RESUMO

INTRODUCTION: In patients with ulnar neuropathy at the elbow (UNE) the precise determination of the site of lesion is important for subsequent differential diagnostic considerations and therapeutic management. Due to a paucity of comparable data, to better define the role of different diagnostic tests, we performed the first prospective study comparing the diagnostic accuracy of short segment nerve stimulation, nerve ultrasonography, MR neurography (MRN), and diffusion tensor imaging (DTI) in patients with UNE. METHODS: UNE was clinically diagnosed in 17 patients with 18 affected elbows. For all 18 affected elbows in patients and 20 elbows in 10 healthy volunteers, measurements of all different diagnostic tests were performed at six anatomical positions across the elbow with measuring points from distal (D4) to proximal (P6) in relation to the medial epicondyle (P0). Additional qualitative assessment regarding structural changes of surrounding nerve anatomy was conducted. RESULTS: The difference between affected arms of patients and healthy control arms were most frequently the largest at measure intervals D2 to P0 and P0 to P2 for electrophysiological testing, or measure points P0 and P2 for all other devices, respectively. At both levels P0 and at P2, T2 contrast-to-noise ratio (CNR) of MRN and mean diffusivity (MD) of DTI-based MRN showed best accuracies. DISCUSSION: This study revealed differences in diagnostic performance of tests concerning a specific location of UNE, with better results for T2 contrast to noise ratio (CNR) in MRN and mean diffusivity of DTI-based MRN. Additional testing with MRN and nerve ultrasonography is recommended to uncover anatomical changes.


Assuntos
Cotovelo , Neuropatias Ulnares , Imagem de Tensor de Difusão , Cotovelo/diagnóstico por imagem , Eletrodiagnóstico , Humanos , Condução Nervosa , Estudos Prospectivos , Nervo Ulnar , Neuropatias Ulnares/diagnóstico por imagem
2.
Magn Reson Med Sci ; 18(2): 150-157, 2019 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-30416178

RESUMO

PURPOSE: Diffusion tensor imaging (DTI) adds functional information to morphological magnetic resonance neurography (MRN) in the assessment of the brachial nerve plexus. To determine the most appropriate pulse sequence in scan times suited for diagnostic imaging in clinical routine, we compared image quality between simultaneous multi-slice readout-segmented (rs-DTI) and conventional single-shot (ss-DTI) echo-planar imaging techniques. METHODS: Institutional Review Board (IRB) approved study including 10 healthy volunteers. The supraclavicular brachial plexus, covering the nerve roots and trunks from C5 to C7, was imaged on both sides with rs-DTI and ss-DTI. Both sequences were acquired in scan times <7 min with b-values of 900 s/mm2 and with isotropic spatial resolution. RESULTS: In rs-DTI image, the overall quality was significantly better and distortion artifacts were significantly lower (P = 0.001-0.002 and P = 0.001-0.002, respectively) for both readers. In ss-DTI, a trend toward lower degree of ghosting and motion artifacts was elicited (reader 1, P = 0.121; reader 2, P = 0.264). No significant differences between the two DTI techniques were found for signal-to-noise ratios (SNR), contrast-to-noise ratios (CNR) and fractional anisotropy (FA) (P ≥ 0.475, P ≥ 0.624, and P ≥ 0.169, respectively). Interreader agreement for all examined parameters and all sequences ranged from intraclass correlation coefficient (ICC) 0.064 to 0.905 and Kappa 0.40 to 0.851. CONCLUSION: Incomparable acquisition times rs-DTI showed higher image quality and less distortion artifacts than ss-DTI. The trend toward a higher degree of ghosting and motion artifacts in rs-DTI did not deteriorate image quality to a significant degree. Thus, rs-DTI should be considered for functional MRN of the brachial plexus.


Assuntos
Plexo Braquial/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Imagem Ecoplanar , Neuroimagem/métodos , Adulto , Anisotropia , Artefatos , Plexo Braquial/patologia , Meios de Contraste , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
3.
eNeurologicalSci ; 10: 31-36, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29736426

RESUMO

INTRODUCTION: The purpose of this study was to analyze the results of patients with ruptured aneurysms who were treated with a specific microstent in the acute phase of subarachnoid hemorrhage. METHODS: Data from patients with acutely-ruptured intracranial aneurysm treated with the Neuroform stent in the period between 2003 and 2016 were retrospectively assessed, addressing aneurysm occlusion and clinical outcome with a focus on periprocedural complications. RESULTS: Twenty-nine consecutive patients with ruptured intracranial aneurysms were included in the analysis. Periprocedural hemorrhagic complications were stated in six patients, leading to death in four. Thromboembolic complications were observed in seven patients, among whom only one affected the clinical outcome with death due to basilar thrombosis. Immediate complete occlusion and occlusion with residual neck was achieved in 79.3% of cases. CONCLUSION: Stent-assisted coiling of acutely-ruptured aneurysms achieves good immediate aneurysm occlusion. Rates of intra- and periprocedural adverse events observed in this series were significant, but did not translate to corresponding morbidity and mortality in all cases. The retrospective analysis did not allow assessing the overall risks of endovascular therapy with stent use in ruptured and complex aneurysm when compared to the overall risks with other alternative options.

4.
Invest Radiol ; 52(8): 482-487, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28291025

RESUMO

OBJECTIVE: The aim of this study was to evaluate the reproducibility of 3 T magnetic resonance imaging diffusion tensor imaging (DTI) of the brachial plexus in healthy subjects. METHODS: Ten healthy volunteers were included, and morphological and DTI sequences of the nerve roots of the brachial plexus from C5 to T1 of both sides were repeatedly acquired on a 3 T magnetic resonance system (MAGNETOM Skyra; Siemens Healthcare, Erlangen, Germany). A prototype diffusion-weighted single-shot echo-planar imaging sequence-enabling slice-specific shim adjustments was performed with b-values of 0 and 800 s/mm in 30 gradient directions, resulting in an acquisition time of about 6 minutes each in axial orientation. Between scans, subjects were moved and repositioned in the scanner, coils were reinserted, and new localizers were acquired. Image analysis was performed using MITK Diffusion software toolkit. Two independent readers performed diffusion data postprocessing, and regions of interest (ROIs) were set on the proximal postganglionic trunk at each spinal level, bilaterally to obtain values for fractional anisotropy (FA) and mean diffusivity (MD). Interreader and intrareader agreement as well as test-retest reproducibility of DTI metrics were assessed. RESULTS: Intraclass correlation coefficients (ICCs) for interreader and intrareader agreement did not differ significantly between measurements for FA and MD. In particular, ICCs for interreader agreement of FA ranged from 0.741 to 0.961 and that of MD ranged from 0.802 to 0.998, and ICCs for intrareader agreement of FA ranged from 0.759 to 0.949 and that of MD ranged from 0.796 to 0.998. The test-retest reproducibility of DTI metrics showed an overall moderate to strong correlation (r > 0.707), with few minor exceptions, for both FA and MD values. CONCLUSIONS: Diffusion tensor imaging metrics in the brachial plexus are reproducible. Future applications of DTI for a possible clinical use should be further investigated.


Assuntos
Plexo Braquial/anatomia & histologia , Imagem de Tensor de Difusão/métodos , Adulto , Plexo Braquial/diagnóstico por imagem , Imagem Ecoplanar/métodos , Feminino , Humanos , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA