Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 455
Filtrar
2.
Artigo em Inglês | MEDLINE | ID: mdl-38661605

RESUMO

BACKGROUND: Recent clinical studies have indicated the presence of localized electrical abnormalities in idiopathic ventricular fibrillation and J-wave syndrome patients. OBJECTIVES: This study aims to characterize the specific electrical signatures of localized repolarization and conduction heterogeneities and their respective role in vulnerability to arrhythmias. METHODS: Optical mapping was performed in porcine right ventricles with local: 1) repolarization shortening; 2) conduction slowing; or 3) structural heterogeneity induced by locally perfusing: 1) pinacidil (20 µmol/L, n = 13); or 2) flecainide (2 µmol/L, n = 13) via an epicardial catheter; or 3) by local epicardial tissue destruction (9 radiofrequency lesions n = 12). Electrograms were recorded (n = 5 in each group) and spontaneous and induced arrhythmias were quantified and optically mapped. RESULTS: Electrograms were normal in (1) but showed local fragmentation in 40% of preparations in (2) with greater effects observed at high pacing frequencies dependent on the wavefront direction. In (3), the structural substrate alone increased the width and number of peaks in the electrograms, and addition of flecainide induced pronounced fragmentation (≥3 peaks and ≥70 ms) in all cases. Occurrence of spontaneous arrhythmias was significantly increased in (1) and (2) (P < 0.0001 and 0.05, respectively, vs baseline) and were triggered by ectopies. Vulnerability to arrhythmias at high pacing frequencies (≥2 Hz) was the lowest in (1) and greatest in (2). CONCLUSIONS: Microstructural substrates have the most pronounced impact on electrograms, especially when combined with sodium channel blockers, whereas local action potential duration shortening does not lead to electrogram fragmentation even though it is associated with the highest prevalence of spontaneous arrhythmias.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38609733

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.

4.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Catéteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
6.
Heart Rhythm ; 2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38286245

RESUMO

BACKGROUND: Differentiating between atypical atrioventricular nodal reentrant tachycardia (AVNRT) and orthodromic reciprocating tachycardia utilizing a septal accessory pathway is a complex challenge. OBJECTIVE: The purpose of this study was to describe the "local VA index," a straightforward method based on signals from the coronary sinus catheter, to distinguish between these arrhythmias during tachycardia and entrainment. The ventriculoatrial (VA) interval on the coronary sinus catheter is measured during tachycardia and entrainment, at the site of earliest atrial activity. The difference between these 2 situations defines the "local VA index." We also propose a mechanism to clarify the limitations of historical pacing maneuvers, such as postpacing interval minus tachycardia cycle length (PPI-TCL) and stimulus-atrial interval minus ventriculoatrial interval (SA-VA), by examining nodal decrement and intraventricular conduction delay. METHODS: In a retrospective study of 75 patients referred for supraventricular tachycardia evaluation, 37 were diagnosed with atrioventricular reentrant tachycardia (AVRT) with orthodromic reciprocating tachycardia, and 38 with AVNRT (27 typical, 11 atypical). RESULTS: In comparison to AVRT patients, AVNRT patients exhibited longer PPI-TCL (176 ± 47 ms vs 113 ± 42 ms; P <.01) and SA-VA (138 ± 47 ms vs 64 ± 28 ms; P <.01). The AVRT group had mean local VA index of -1 ± 13 ms, whereas the AVNRT group had a significantly longer index of 91 ± 46 ms (P <.01). An optimal threshold for differentiation was a local VA index of 40 ms. Importantly, there was no significant correlation between pacing cycle length and nodal decrement as well as intraventricular delay related to pathway location. This interindividual variability might explain misleading interpretations of PPI-TCL and SA-VA. CONCLUSION: This novel approach is advantageous because of its simplicity and effectiveness, requiring only 2 diagnostic catheters. A local VA interval difference <40 ms provides a clear distinction for AVRT.

7.
JACC Clin Electrophysiol ; 10(1): 1-12, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37855774

RESUMO

BACKGROUND: There are few data on ventricular fibrillation (VF) initiation in patients with inferolateral J waves. OBJECTIVES: This multicenter study investigated the characteristics of triggers initiating spontaneous VF in inferolateral J-wave syndrome. METHODS: A total of 31 patients (age 37 ± 14 years, 24 male) with spontaneous VF episodes associated with inferolateral J waves were evaluated to determine the origin and characteristics of triggers. The J-wave pattern was recorded in inferior leads in 11 patients, lateral leads in 3, and inferolateral leads in 17. RESULTS: The VF triggers (n = 37) exhibited varying QRS durations (176 ± 21 milliseconds, range 119-219 milliseconds) and coupling intervals (339 ± 46 milliseconds, range 250-508 milliseconds) with a right (70%) or left (30%) bundle branch block (BBB) pattern. Trigger patterns were associated with J-wave location: left BBB triggers with inferior J waves and right BBB triggers with lateral J waves. Electrophysiologic study was performed for 22 VF triggers in 19 patients. They originated from the left or right Purkinje system in 6 and from the ventricular myocardium in 10 and were undetermined in 6. Purkinje vs myocardial triggers showed distinct electrocardiographic characteristics in coupling interval and QRS-complex duration and morphology. Abnormal epicardial substrate associated with fragmented electrograms was identified in 9 patients, with triggers originating from the same region in 7 patients. Catheter ablation resulted in VF suppression in 15 patients (79%). CONCLUSIONS: VF initiation in inferolateral J-wave syndrome is associated with significant individual heterogeneity in trigger characteristics. Myocardial triggers have electrocardiographic features distinct from Purkinje triggers, and their origin often colocalizes with an abnormal epicardial substrate.


Assuntos
Síndrome de Brugada , Fibrilação Ventricular , Humanos , Masculino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Eletrocardiografia/métodos , Doença do Sistema de Condução Cardíaco , Ventrículos do Coração
8.
Circ Arrhythm Electrophysiol ; 16(10): e012241, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37728002

RESUMO

BACKGROUND: Abnormal atrial potentials (AAPs) recorded during sinus rhythm/atrial pacing may indicate areas of slow conduction capable of supporting reentrant atrial tachycardia (AT). Therefore, we sought to examine the relationship between AAPs and AT circuits. METHODS: One hundred twenty-three reentrant ATs in 104 patients were analyzed. AAPs, consisting of fragmented potentials and split potentials, were assessed using the Rhythmia LUMIPOINT algorithm. RESULTS: There was 93±13% overlap between areas with AAPs during sinus rhythm/atrial pacing and areas of slow conduction along the reentry circuit during AT. The cumulative area of AAPs was smaller in patients with localized-reentrant ATs compared with anatomic macro-reentrant ATs (20.0 [14.6-30.5] versus 28.9 [21.8-35.6] cm2; P=0.021). Patients with perimitral ATs had larger areas of AAPs on the lateral wall whereas patients with roof-dependent ATs had larger areas of AAPs on the roof and posterior wall (P≤0.018 for all comparisons). The patchy scar that was associated with localized-reentrant AT exhibited a larger area of AAPs at its periphery than the scar that did not participate in localized-reentrant AT (3.1 [2.4-4.5] versus 1.0 [0.7-1.6] cm2; P<0.001). CONCLUSIONS: AAPs recorded during sinus rhythm/atrial pacing are associated with areas of slow conduction during reentrant AT. The burden and distribution of AAPs may provide actionable insights into AT circuit features, including in cases in which ATs are difficult to map.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Cicatriz , Átrios do Coração , Frequência Cardíaca , Estimulação Cardíaca Artificial
9.
JACC Clin Electrophysiol ; 9(10): 2054-2066, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37715740

RESUMO

BACKGROUND: Substrate abnormalities can alter atrial activation during atrial tachycardias (ATs) thereby influencing AT-wave morphology on the surface electrocardiogram. OBJECTIVES: This study sought to identify determinants of isoelectric intervals during ATs with complex atrial activation patterns. METHODS: High-density activation maps of 126 ATs were studied. To assess the impact of the activated atrial surface on the presence of isoelectric intervals, this study measured the minimum activated area throughout the AT cycle, defined as the smallest activated area within a 50-millisecond period, by using signal processing algorithms (LUMIPOINT). RESULTS: ATs with isoelectric intervals (P-wave ATs) included 23 macro-re-entrant ATs (40%), 26 localized-re-entrant ATs (46%), and 8 focal ATs (14%), whereas those without included 46 macro-re-entrant ATs (67%), 21 localized-re-entrant ATs (30%), and 2 focal ATs (3%). Multivariable regression identified smaller minimum activated area and larger very low voltage area as independent predictors of P-wave ATs (OR: 0.732; 95% CI: 0.644-0.831; P < 0.001; and OR: 1.042; 95% CI: 1.006-1.080; P = 0.023, respectively). The minimum activated area with the cutoff value of 10 cm2 provided the highest predictive accuracy for P-wave ATs with sensitivity, specificity, and positive and negative predictive values of 96%, 97%, 97%, and 95%, respectively. In re-entrant ATs, smaller minimum activated area was associated with lower minimum conduction velocity within the circuit and fewer areas of delayed conduction outside of the circuit (standardized ß: 0.524; 95% CI: 0.373-0.675; P < 0.001; and standardized ß: 0.353; 95% CI: 0.198-0.508; P < 0.001, respectively). CONCLUSIONS: Reduced atrial activation area and voltage were associated with isoelectric intervals during ATs.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Eletrocardiografia
10.
Heart Rhythm ; 20(10): 1370-1377, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37414109

RESUMO

BACKGROUND: Omnipolar technology (OT) was recently proposed to generate electroanatomic voltage maps with orientation-independent electrograms. We describe the first cohort of patients undergoing ventricular tachycardia (VT) ablation guided by OT. OBJECTIVE: The purpose of this study was to compare omnipolar and bipolar high-density maps with regard to voltage amplitude, late potential (LP) annotation, and isochronal late activation mapping distribution. METHODS: A total of 24 patients (16 [66%] ischemic cardiomyopathy and 12 [50%] redo cases) underwent VT ablation under OT guidance. Twenty-seven sinus rhythm substrate maps and 10 VT activation maps were analyzed. Omnipolar and bipolar (HD Wave Solution algorithm, Abbott, Abbott Park, IL) voltages were compared. Areas of LPs were correlated with the VT isthmus areas, and late electrogram misannotation was evaluated. Deceleration zones based on isochronal late activation maps were analyzed by 2 blinded operators and compared to the VT isthmuses. RESULTS: OT maps had higher point density (13.8 points/cm2 vs 8.0 points/cm2). Omnipolar points had 7.1% higher voltages than bipolar points within areas of dense scar and border zone. The number of misannotated points was significantly lower for OT maps (6.8% vs 21.9%; P = .01), showing comparable sensitivity (53% vs 59%) but higher specificity (79% vs 63%). The sensitivity and specificity of detection of the VT isthmus in the deceleration zones were, respectively, 75% and 65% for OT and 35% and 55% for bipolar mapping. At 8.4 months, 71% freedom from VT recurrence was achieved. CONCLUSION: OT is a valuable tool for guiding VT ablation, providing more accurate identification of LPs and isochronal crowding due to slightly higher voltages.

11.
JACC Clin Electrophysiol ; 9(10): 2041-2051, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37480873

RESUMO

BACKGROUND: Slow-conductive structural abnormalities located in the epicardium of the right ventricle (RV) underlie Brugada syndrome (BrS). The extent of such substrate in the left ventricle (LV) has not been investigated. OBJECTIVES: This study sought to characterize the extent of epicardial substrate abnormalities in BrS. METHODS: We evaluated 22 consecutive patients (mean age 46 ± 11 years, 21 male) referred for recurrent ventricular arrhythmias (mean 10 ± 13 episodes) in the setting of BrS. The patients underwent clinical investigations and wide genetic screening to identify SCN5A mutations and common risk variants. High-density biventricular epicardial mapping was performed to detect prolonged (>70 ms) fragmented electrograms, indicating abnormal substrate area. RESULTS: All patients presented with abnormal substrate in the epicardial anterior RV (27 ± 11 cm2). Abnormal substrate was also identified on the LV epicardium in 10 patients (45%), 9 at baseline and 1 after ajmaline infusion, covering 15 ± 11 cm2. Of these, 4 had severe LV fascicular blocks. Patients with LV substrate had a longer history of arrhythmia (11.4 ± 6.7 years vs 4.3 ± 4.3 years; P = 0.003), longer PR (217 ± 24 ms vs 171 ± 14 ms; P < 0.001) and HV (60 ± 12 ms vs 46 ± 5 ms; P = 0.005) intervals, and abnormal substrate also extending into the inferior RV (100% vs 33%; P = 0.001). SCN5A mutation was present in 70% of patients with LV substrate (vs 25%; P = 0.035). SCN5A BrS patients with recurrent ventricular arrhythmias present a higher polygenic risk score compared with a nonselected BrS population (median of differences: -0.86; 95% CI: -1.48 to -0.27; P = 0.02). CONCLUSIONS: A subset of patients with BrS present an abnormal substrate extending onto the LV epicardium and inferior RV that is associated with SCN5A mutations and multigenic variants.


Assuntos
Síndrome de Brugada , Ventrículos do Coração , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Ventrículos do Coração/diagnóstico por imagem , Síndrome de Brugada/diagnóstico , Eletrocardiografia , Mapeamento Epicárdico , Arritmias Cardíacas
12.
J Cardiovasc Electrophysiol ; 34(8): 1708-1717, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37431258

RESUMO

BACKGROUND: The impact of filtering on bipolar electrograms (EGMs) has not been systematically examined. We tried to clarify the optimal filter configuration for ventricular tachycardia (VT) ablation. METHODS: Fifteen patients with VT were included. Eight different filter configurations were prospectively created for the distal bipoles of the ablation catheter: 1.0-250, 10-250, 100-250, 30-50, 30-100, 30-250, 30-500, and 30-1000 Hz. Pre-ablation stable EGMs with good contact (contact force > 10 g) were analyzed. Baseline fluctuation, baseline noise, bipolar peak-to-peak voltage, and presence of local abnormal ventricular activity (LAVA) were compared between different filter configurations. RESULTS: In total, 2276 EGMs with multiple bipolar configurations in 246 sites in scar and border areas were analyzed. Baseline fluctuation was only observed in the high-pass filter of (HPF) ≤ 10 Hz (p < .001). Noise level was lowest at 30-50 Hz (0.018 [0.012-0.029] mV), increased as the low-pass filter (LPF) extended, and was highest at 30-1000 Hz (0.047 [0.041-0.061] mV) (p < .001). Conversely, the HPF did not affect the noise level at ≤30 Hz. As the HPF extended to 100 Hz, bipolar voltages significantly decreased (p < .001), but were not affected when the LPF was extended to ≥100 Hz. LAVAs were most frequently detected at 30-250 Hz (207/246; 84.2%) and 30-500 Hz (208/246; 84.6%), followed by 30-1000 Hz (205/246; 83.3%), but frequently missed at LPF ≤ 100 Hz or HPF ≤ 10 Hz (p < .001). A 50-Hz notch-filter reduced the bipolar voltage by 43.9% and LAVA-detection by 34.5% (p < .0001). CONCLUSION: Bipolar EGMs are strongly affected by filter settings in scar/border areas. In all, 30-250 or 30-500 Hz may be the best configuration, minimizing the baseline fluctuation, baseline noise, and detecting LAVAs. Not applying the 50-Hz notch filter may be beneficial to avoid missing VT substrate.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Cicatriz , Ablação por Cateter/efeitos adversos
13.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37428890

RESUMO

AIMS: Although the mechanism of an atrial tachycardia (AT) can usually be elucidated using modern high-resolution mapping systems, it would be helpful if the AT mechanism and circuit could be predicted before initiating mapping. OBJECTIVE: We examined if the information gathered from the cycle length (CL) of the tachycardia can help predict the AT-mechanism and its localization. METHODS: One hundred and thirty-eight activation maps of ATs including eight focal-ATs, 94 macroreentrant-ATs, and 36 localized-ATs in 95 patients were retrospectively reviewed. Maximal CL (MCL) and minimal CL (mCL) over a minute period were measured via a decapolar catheter in the coronary sinus. CL-variation and beat-by-beat CL-alternation were examined. Additionally, the CL-respiration correlation was analysed by the RhythmiaTM system. : Both MCL and mCL were significantly shorter in macroreentrant-ATs [MCL = 288 (253-348) ms, P = 0.0001; mCL = 283 (243-341) ms, P = 0.0012], and also shorter in localized-ATs [MCL = 314 (261-349) ms, P = 0.0016; mCL = 295 (248-340) ms, P = 0.0047] compared to focal-ATs [MCL = 506 (421-555) ms, mCL = 427 (347-508) ms]. An absolute CL-variation (MCL-mCL) < 24 ms significantly differentiated re-entrant ATs from focal-ATs with a sensitivity = 96.9%, specificity = 100%, positive predictive value (PPV) = 100%, and negative predictive value (NPV) = 66.7%. The beat-by-beat CL-alternation was observed in 10/138 (7.2%), all of which showed the re-entrant mechanism, meaning that beat-by-beat CL-alternation was the strong sign of re-entrant mechanism (PPV = 100%). Although the CL-respiration correlation was observed in 28/138 (20.3%) of ATs, this was predominantly in right-atrium (RA)-ATs (24/41, 85.7%), rather than left atrium (LA)-ATs (4/97, 4.1%). A positive CL-respiration correlation highly predicted RA-ATs (PPV = 85.7%), and negative CL-respiration correlation probably suggested LA-ATs (NPV = 84.5%). CONCLUSION: Detailed analysis of the tachycardia CL helps predict the AT-mechanism and the active AT chamber before an initial mapping.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Humanos , Estudos Retrospectivos , Técnicas Eletrofisiológicas Cardíacas , Taquicardia , Átrios do Coração , Resultado do Tratamento
16.
J Cardiovasc Electrophysiol ; 34(6): 1395-1404, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37232426

RESUMO

AIM: Ventricular arrhythmias (VAs) are the most common cause of death in patients with repaired Tetralogy of Fallot (rTOF). However, risk stratifying remains challenging. We examined outcomes following programmed ventricular stimulation (PVS) with or without subsequent ablation in patients with rTOF planned for pulmonary valve replacement (PVR). METHODS: We included all consecutive patients with rTOF referred to our institution from 2010 to 2018 aged ≥18 years for PVR. Right ventricular (RV) voltage maps were acquired and PVS was performed from two different sites at baseline, and if non-inducible under isoproterenol. Catheter and/or surgical ablation was performed when patients were inducible or when slow conduction was present in anatomical isthmuses (AIs). Postablation PVS was undertaken to guide implantable cardioverter-defibrillator (ICD) implantation. RESULTS: Seventy-seven patients (36.2 ± 14.3 years old, 71% male) were included. Eighteen were inducible. In 28 patients (17 inducible, 11 non-inducible but with slow conduction) ablation was performed. Five had catheter ablation, surgical cryoablation in 9, both techniques in 14. ICDs were implanted in five patients. During a follow-up of 74 ± 40 months, no sudden cardiac death occurred. Three patients experienced sustained VAs, all were inducible during the initial EP study. Two of them had an ICD (low ejection fraction for one and important risk factor for arrhythmia for the second). No VAs were reported in the non-inducible group (p < .001). CONCLUSION: Preoperative EPS can help identifying patients with rTOF at risk for VAs, providing an opportunity for targeted ablation and may improve decision-making regarding ICD implantation.


Assuntos
Implante de Prótese de Valva Cardíaca , Valva Pulmonar , Taquicardia Ventricular , Tetralogia de Fallot , Humanos , Masculino , Adolescente , Adulto , Adulto Jovem , Pessoa de Meia-Idade , Feminino , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/complicações , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
17.
JACC Clin Electrophysiol ; 9(8 Pt 1): 1248-1261, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37227351

RESUMO

BACKGROUND: Brugada syndrome is a significant cause of sudden cardiac death (SCD), but the underlying mechanisms remain hypothetical. OBJECTIVES: This study aimed to elucidate this knowledge gap through detailed ex vivo human heart studies. METHODS: A heart was obtained from a 15-year-old adolescent boy with normal electrocardiogram who experienced SCD. Postmortem genotyping was performed, and clinical examinations were done on first-degree relatives. The right ventricle was optically mapped, followed by high-field magnetic resonance imaging and histology. Connexin-43 and NaV1.5 were localized by immunofluorescence, and RNA and protein expression levels were studied. HEK-293 cell surface biotinylation assays were performed to examine NaV1.5 trafficking. RESULTS: A Brugada-related SCD diagnosis was established for the donor because of a SCN5A Brugada-related variant (p.D356N) inherited from his mother, together with a concomitant NKX2.5 variant of unknown significance. Optical mapping demonstrated a localized epicardial region of impaired conduction near the outflow tract, in the absence of repolarization alterations and microstructural defects, leading to conduction blocks and figure-of-8 patterns. NaV1.5 and connexin-43 localizations were normal in this region, consistent with the finding that the p.D356N variant does not affect the trafficking, nor the expression of NaV1.5. Trends of decreased NaV1.5, connexin-43, and desmoglein-2 protein levels were noted; however, the RT-qPCR results suggested that the NKX2-5 variant was unlikely to be involved. CONCLUSIONS: This study demonstrates for the first time that SCD associated with a Brugada-SCN5A variant can be caused by localized functionally, not structurally, impaired conduction.


Assuntos
Síndrome de Brugada , Masculino , Adolescente , Humanos , Células HEK293 , Eletrocardiografia , Doença do Sistema de Condução Cardíaco , Morte Súbita Cardíaca , Conexinas
18.
Curr Cardiol Rep ; 25(6): 535-542, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37115434

RESUMO

PURPOSE OF REVIEW: Imaging plays a crucial role in the therapy of ventricular tachycardia (VT). We offer an overview of the different methods and provide information on their use in a clinical setting. RECENT FINDINGS: The use of imaging in VT has progressed recently. Intracardiac echography facilitates catheter navigation and the targeting of moving intracardiac structures. Integration of pre-procedural CT or MRI allows for targeting the VT substrate, with major expected impact on VT ablation efficacy and efficiency. Advances in computational modeling may further enhance the performance of imaging, giving access to pre-operative simulation of VT. These advances in non-invasive diagnosis are increasingly being coupled with non-invasive approaches for therapy delivery. This review highlights the latest research on the use of imaging in VT procedures. Image-based strategies are progressively shifting from using images as an adjunct tool to electrophysiological techniques, to an integration of imaging as a central element of the treatment strategy.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Coração , Frequência Cardíaca , Ablação por Cateter/métodos , Resultado do Tratamento
19.
IEEE Trans Biomed Eng ; 70(7): 2131-2138, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37018681

RESUMO

OBJECTIVE: About half of patients experience recurrence of atrial fibrillation (AF) within three to five years after a single catheter ablation procedure. The suboptimality of the long-term outcomes likely results from the inter-patient variability of AF mechanisms, which can be remedied by improved patient screening. We aim to improve the interpretation of body surface potentials (BSPs), such as 12-lead electrocardiograms and 252-lead BSP maps, to aid preoperative patient screening. METHODS: We developed the Atrial Periodic Source Spectrum (APSS), a novel patient-specific representation based on atrial periodic content, computed on the f-wave segments of patient BSPs, using a second-order blind source separation and a Gaussian Process for regression. With follow-up data, Cox's proportional hazard model was used to select the most relevant feature from preoperative APSSs responsible for AF recurrence. RESULTS: Over 138 persistent AF patients, the presence of highly periodic content with cycle lengths between 220-230 ms or 350-400 ms indicates higher risks of 4-year post-ablation AF recurrence (log-rank test, p-value ). CONCLUSION AND SIGNIFICANCE: Preoperative BSPs demonstrate effective prediction in the long-term outcomes, highlighting their potential for patient screening in AF ablation therapy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Recidiva , Fatores de Tempo , Átrios do Coração , Ablação por Cateter/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA