Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-37516385

RESUMO

OBJECTIVES: The aim of this study was to investigate the clinical relevance of an isolated positive sonication fluid culture (SFC) in patients who underwent revision surgery of a prosthetic joint. We hypothesized that cases with a positive SFC have a higher rate of infection during follow-up compared with controls with a negative SFC. METHODS: This retrospective multicentre observational study was performed within the European Study Group of Implant-Associated Infections. All patients who underwent revision surgery of a prosthetic joint between 2013 and 2019 and had a minimum follow-up of 1 year were included. Patients with positive tissue cultures or synovial fluid cultures were excluded from the study. RESULTS: A total of 95 cases (positive SFC) and 201 controls (negative SFC) were included. Infection during follow-up occurred in 12 of 95 cases (12.6%) versus 14 of 201 controls (7.0%) (p = 0.125). In all, 79.8% of cases were with treated with antibiotics (76/95). Of the non-treated cases, 89% (17/19) had a positive SFC with a low virulent microorganism. When solely analysing patients who were not treated with antibiotics, 16% of the cases (3/19) had an infection during follow-up versus 5% of the controls (9/173) (p = 0.08). DISCUSSION: Although not statistically significant, infections were almost twice as frequent in patients with an isolated positive SFC. These findings require further exploration in larger trials and to conclude about the potential benefit of antibiotic treatment in these cases.

2.
Clin Orthop Relat Res ; 473(6): 2079-87, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25832007

RESUMO

BACKGROUND: Primary bone or soft tissue tumors of the femur sometimes present with severe and extensive bone destruction, leaving few limb-salvage options other than total femur replacement. However, there are few data available regarding total femur replacement and, in particular, regarding implant failures. QUESTIONS/PURPOSES: We asked: (1) What are the revision-free and overall implant survival rates of conventional total femur replacements in patients treated for sarcoma of the femur or soft tissues? (2) What are the revision-free and overall implant survival rates of expandable total femur replacements in skeletally immature patients? (3) Using the comprehensive International Society of Limb Salvage failure-mode classification, what types of complications occur with conventional and expandable total femur replacements? PATIENTS AND METHODS: Our retrospective, single-center cohort study was based on data prospectively collected for 50 patients who received a total femur replacement after tumor resection for indications other than carcinoma or metastatic disease. Of the 50 patients, six (12%) were lost to followup before 6 months. Ten of the remaining 44 patients received expandable implants. The mean followup was 57 months (range, 1-280 months) and 172 months (range, 43-289 months) for patients who underwent conventional and expandable total femur replacements, respectively. For implant survival, competing risk analyses were used. RESULTS: At 5 years, revision-free implant survival of conventional total femur replacements was 48% (95% CI, 0.37-0.73), and overall implant survival was 97% (95% CI, 0.004-0.20). Five-year revision-free implant survival of expandable total femur replacements was 30% (95% CI, 0.47-1.00) and overall implant survival was 100%. With conventional total femur replacements soft tissue failures occurred in 13 of 34 patients, structural failures in three, infection in six, and local tumor progression in one. No patient had aseptic loosening with conventional total femur replacements, but hip disarticulation occurred in two patients owing to extensive wound-healing problems and infection. With expandable total femur replacements soft tissue failure, aseptic loosening, and infection occurred in one patient each of 10, and structural failures in three of 10 (two periprosthetic fractures, one loosening of an enhanced tendon anchor). No hip disarticulations were performed. Additionally expandable total femur replacement-related failures included hip instability in eight of 10 patients, contractures attributable to massive scar tissue in six, and defect of the implant's expansion mechanism in four patients. CONCLUSIONS: Although the indications for total femoral resection are rare, we think that total femur replacement is a reasonable treatment option for reconstruction of massive femoral bone defects after tumor resection in adults and skeletally immature patients, and results in limb salvage in most patients. LEVEL OF EVIDENCE: Level IV, therapeutic study.


Assuntos
Neoplasias Femorais/cirurgia , Salvamento de Membro , Osteotomia , Procedimentos de Cirurgia Plástica/instrumentação , Falha de Prótese , Implantação de Prótese/instrumentação , Sarcoma/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Áustria , Criança , Pré-Escolar , Intervalo Livre de Doença , Neoplasias Femorais/diagnóstico por imagem , Neoplasias Femorais/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Osseointegração , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Radiografia , Procedimentos de Cirurgia Plástica/efeitos adversos , Procedimentos de Cirurgia Plástica/métodos , Reoperação , Estudos Retrospectivos , Fatores de Risco , Sarcoma/diagnóstico por imagem , Sarcoma/patologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
3.
Clin Orthop Relat Res ; 473(3): 839-46, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24748070

RESUMO

BACKGROUND: Limb salvage surgery has evolved to become the standard method of treating sarcomas of the extremities with acceptable oncologic results. However, little information exists relative to the activity level or ability to participate in sports after tumor reconstructions. QUESTIONS/PURPOSES: The aims of the study were to answer the following questions: (1) Which sports activity levels and what types of sports can be expected in the long term after tumor reconstruction? (2) Which frequency durations are patients with Ewing's sarcoma able to perform in long-term followup after local control? (3) Do surgical complications affect sports activity level? METHODS: Thirty patients (13 females, 17 males; mean age, 18 ± 8 years; range, 2-36 years at diagnosis; mean followup 16 ± 6 years [minimum, 5 years]) were included. Tumors were located in the pelvis, femur, tibia, and fibula. Surgical procedures included surgical resections alone (n = 8), surgical resection with biological reconstruction (n = 9), or endoprosthetic reconstruction (n = 13). We assessed UCLA sports activity levels, kinds of sports as well as the frequency per week and the duration of each training unit at long term (minimum followup, 5 years). RESULTS: In long-term followup 83% patients (25 of 30) were performing athletic activity regularly. The hours/week of sports depended on type of surgery and were highest after resections in the pelvis and femur (5.8) and were lowest after megaprosthetic reconstruction of the pelvis (1.0). Patients undergoing biologic reconstructions were able to perform high-impact sports. UCLA sports activity levels were high after joint-preserving vascularized fibula for tibia reconstruction (7.4) and after megaprosthetic reconstruction of the lower extremity (6.3-6.4) and were low after tumors located in the fibula (4.2). Complications during followup did not significantly influence sports activity in long-term survivors. CONCLUSIONS: Long-term survivors can achieve high levels of sports activity in many instances. Tumor sites are associated with the postoperative sports activity levels. This information can help surgeons counsel patients in terms of athletic expectations after limb salvage reconstruction for patients with Ewing's sarcoma. LEVEL OF EVIDENCE: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Neoplasias Ósseas/cirurgia , Salvamento de Membro , Extremidade Inferior/cirurgia , Sarcoma de Ewing/cirurgia , Esportes , Adolescente , Adulto , Neoplasias Ósseas/fisiopatologia , Criança , Pré-Escolar , Feminino , Humanos , Extremidade Inferior/fisiopatologia , Masculino , Procedimentos de Cirurgia Plástica/métodos , Sarcoma de Ewing/fisiopatologia , Sobreviventes , Resultado do Tratamento , Adulto Jovem
4.
Int Orthop ; 38(5): 983-9, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24492997

RESUMO

PURPOSE: The proximal chevron osteotomy provides high correctional power. However, relatively high rates of dorsiflexion malunion of up to 17 % are reported for this procedure. This leads to insufficient weight bearing of the first ray and therefore to metatarsalgia. Recent biomechanical and clinical studies pointed out the importance of rigid fixation of proximal metatarsal osteotomies. Therefore, the aim of the present study was to compare biomechanical properties of fixation of proximal chevron osteotomies with variable locking plate and cancellous screw respectively. METHODS: Ten matched pairs of human fresh frozen cadaveric first metatarsals underwent proximal chevron osteotomy with either variable locking plate or cancellous screw fixation after obtaining bone mineral density. Biomechanical testing included repetitive plantar to dorsal loading from 0 to 31 N with the 858 Mini Bionix(®) (MTS(®) Systems Corporation, Eden Prairie, MN, USA). Dorsal angulation of the distal fragment was recorded. RESULTS: The variable locking plate construct reveals statistically superior results in terms of bending stiffness and dorsal angulation compared to the cancellous screw construct. There was a statistically significant correlation between bone mineral density and maximum tolerated load until construct failure occurred for the screw construct (r = 0.640, p = 0.406). CONCLUSION: The results of the present study indicate that variable locking plate fixation shows superior biomechanical results to cancellous screw fixation for proximal chevron osteotomy. Additionally, screw construct failure was related to levels of low bone mineral density. Based on the results of the present study we recommend variable locking plate fixation for proximal chevron osteotomy, especially in osteoporotic bone.


Assuntos
Placas Ósseas , Parafusos Ósseos , Hallux Valgus/cirurgia , Ossos do Metatarso/cirurgia , Osteotomia/métodos , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Desenho de Equipamento , Humanos , Pessoa de Meia-Idade , Osteotomia/instrumentação
5.
Clin Biomech (Bristol, Avon) ; 26(6): 620-5, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21392869

RESUMO

INTRODUCTION: Arthrodesis is a well-established treatment option for end-stage osteoarthritis of the ankle. Osteoarthritis of the ankle can alter plantar pressure distribution. However, surprisingly little is known about the effect of ankle arthrodesis to alter plantar pressure distribution. The purpose of this study was to determine plantar pressure distribution in a selected group of patients with unilateral arthrodesis of the ankle joint. METHODS: 20 patients with an average age of 60 years who underwent isolated unilateral ankle arthrodesis using a 3-crossed screw technique by a single surgeon were included. After a mean of 25 months (range 12-75 months) post surgery plantar pressure distribution was determined in five regions of the foot. The outcome was evaluated clinically, using the American Orthopaedic Foot and Ankle Society hindfoot score, as well as radiographically. The contralateral normal foot was used as a control. FINDINGS: Comparing the foot that underwent tibiotalar arthrodesis to the contralateral normal foot, differences were found in the peak pressure and maximum force in the toe region and the lateral midfoot region. In addition, a decrease in the contact time in the forefoot region and a decrease of the contact area in the toe region of the operated foot were identified. The other regions did not show a significant difference. The mean American Orthopaedic Foot and Ankle Society score of the operated leg was 79 (range 46-92) at the last follow up, and the mean fixation angle of the arthrodesis on lateral weight bearing radiographs was 90° (range 86°-100°). INTERPRETATION: Our results indicate that arthrodesis of the ankle joint can provide high levels of function with minimal changes in the plantar pressure distribution.


Assuntos
Tornozelo/fisiologia , Artroplastia de Substituição/métodos , Pé/fisiologia , Osteoartrite/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Artrodese , Fenômenos Biomecânicos , Feminino , Alimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/patologia , Pressão , Estudos Retrospectivos , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA