1.
JACC Clin Electrophysiol ; 10(5): 916-926, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38520434

RESUMO

BACKGROUND: Past clinical trials have shown the benefit of implantable cardioverter-defibrillators (ICDs) for reducing sudden cardiac death in at-risk patients. However, heart failure management and ICD technology have changed since these trials were first published. An updated assessment of ICD mortality benefit is needed. OBJECTIVES: The purpose of this study was to compare mortality rates between patients with a primary prevention (PP) indication for an ICD who did or did not receive an ICD using a contemporary, real-world data set. METHODS: Data was obtained from a large electronic health record data set covering patients in the United States from 2012 through 2020 who had a PP indication for an ICD and survived at least 1-year postindication. RESULTS: A total of 25,296 patients were identified as having a PP indication for ICD implantation, of which 2,118 (8.4%) were treated with an ICD within a year. Treated patients were younger than nontreated patients (age 63.4 years vs 66.1 years) with a smaller proportion of women (25.0% vs 36.7%). After 4-to-1 propensity matching, treated patients had similar clinical characteristics to nontreated patients. A Cox proportional hazard model estimated a 24.3% lower risk of all-cause mortality in patients when treated vs not treated with an ICD (HR: 0.757; 95% CI: 0.678-0.835; P <0.001). There was no detectable difference in ICD benefit between patients with ischemic and nonischemic heart disease (P = 0.50). CONCLUSIONS: ICD treatment of patients with a PP indication is associated with improved mortality even in the context of evolving adjunctive HF treatment, consistent with earlier landmark trials.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Prevenção Primária , Humanos , Desfibriladores Implantáveis/estatística & dados numéricos , Feminino , Masculino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Pessoa de Meia-Idade , Idoso , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/epidemiologia , Estados Unidos/epidemiologia , Estudos Retrospectivos
2.
Pacing Clin Electrophysiol ; 37(7): 820-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24484075

RESUMO

BACKGROUND: Remote monitoring (RM) of defibrillators (implantable cardioverter defibrillators [ICDs]) and cardiac resynchronization therapy devices (CRTDs) has been shown to be cost effective, convenient, and associated with reduced mortality and a reduction in the time to physician intervention for actionable events. However, patient compliance with monitoring over time and what factors might influence such compliance have not been well described. This study sought to identify factors contributing to patient noncompliance with RM of ICDs and CRTDs in a large real-world population. METHODS: Deidentified data on U.S. patients enrolled in the Medtronic CareLink RM system were used to compare patients with no (noncompliant, n = 14,848) and with ≥ 2 RM transmissions (compliant, n = 103,284) during a 14-month period. RESULTS: Overall noncompliance with RM was 21%. Younger age (≤ 40), female sex, wanded device, Medicare Census Division, and small clinic size all predicted patient noncompliance (P < 0.01). Device type (ICD vs CRTD) did not (P = 0.52). Multivariate analysis suggested clinically important predictors of noncompliance to be: age ≤ 40, odds ratio (OR) 2.64 (95% confidence interval, 2.42-2.88); Medicare Census Division (Mountain vs West North Central), OR 2.15 (1.96-2.37); and small clinic size (1-4 vs >100 patients), OR 4.38 (3.92-4.91). CONCLUSIONS: There is room for improvement in RM usage among enrolled patients. Younger patients, smaller clinics, and certain geographic areas may be targets for research into interventions to further improve the use of RM.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Cooperação do Paciente/estatística & dados numéricos , Tecnologia de Sensoriamento Remoto , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos