J Endovasc Ther ; : 15266028241234001, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38410837

RESUMO

PURPOSE: To compare procedural and long-term costs associated with the use of Balloon-Expandable Covered Stents (BECS) in the management of Aortoiliac Occlusive Disease (AIOD). MATERIALS AND METHODS: A cost-consequence model was developed to simulate the intra- and post-operative management of patients with AIOD from the perspective of private health-payers. The study assessed the costs of the LifeStream (BD, Franklin Lakes, New Jersey), iCAST/Advanta V12 (Getinge, Goteborg, Sweden), BeGraft Peripheral (Bentley, Hechingen, Germany), and Viabahn Balloon Expandable (VBX) (W.L. Gore, Flagstaff, Arizona) BECS devices. Device costs were identified from the Australian Prosthesis List, whereas clinical outcomes of BECS were estimated from a systematic review of the literature. Costs were calculated over 24 and 36 month time horizons and reported in US dollars. RESULTS: Long-term, per-patient cost of each device at 24 and 36 months was $6253/$6634 for the LifeStream; $6359/$6869 for the iCAST/Advanta V12; $4806 (data available to 24 months) for the BeGraft Peripheral; and $4839/$5046 for the Viabahn VBX, respectively. Most of the cost difference was attributed to the number of stents required per treated limb and frequency of clinically-driven target lesion revascularization events. CONCLUSIONS: Best-available clinical evidence and economic modeling demonstrates that the BeGraft Peripheral and Viabahn VBX were of similar cost and the least costly options at 24 months, whereas at 36 months, the lowest cost BECS option for the treatment of AIOD was the Viabahn VBX. CLINICAL IMPACT: This analysis supports economically informed decision-making for health-payers managing systems that care for patients with AIOD. Stent length and avoiding reintervention were identified as key areas of cost-saving for future BECS development.

2.
J Vasc Surg ; 79(5): 1090-1100.e4, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38185214

RESUMO

OBJECTIVE: To determine the safety and efficacy of treating abdominal aortic aneurysm (AAA) sacs with polyurethane shape memory polymer (SMP) devices during endovascular aneurysm repair (EVAR), using a technique to fully treat the target lumen after endograft placement (aortic flow volume minus the endograft volume). SMP devices self-expand in the sac to form a porous scaffold that supports thrombosis throughout its structure. METHODS: Two identical prospective, multicenter, single-arm studies were conducted in New Zealand and the Netherlands. The study population was adult candidates for elective EVAR of an infrarenal AAA (diameter of ≥55 mm in men and ≥50 mm in women). Key exclusion criteria were an inability to adequately seal a common iliac artery aneurysm, patent sac feeding vessels of >4 mm, and a target lumen volume of <20 mL or >135 mL. Target lumen volumes were estimated by subtracting endograft volumes from preprocedural imaging-based flow lumen volumes. SMP devices were delivered immediately after endograft deployment via a 6F sheath jailed in a bowed position in the sac. The primary efficacy end point was technical success, defined as filling the actual target lumen volume with fully expanded SMP at the completion of the procedure. Secondary efficacy outcome measures during follow-up were the change in sac volume and diameter, rate of type II endoleak and type I or III endoleaks, and the rate of open repair and related reinterventions, with data collection at 30 days, 6 months, and 1 year (to date). Baseline sac volumes and diameters for change in sac size analyses were determined from 30-day imaging studies. Baseline and follow-up volumes were normalized by subtraction of the endograft volume. RESULTS: Of 34 patients treated with SMP devices and followed per protocol, 33 patients were evaluable at 1 year. Preprocedural aneurysm volume was 181.4 mL (95% confidence interval [CI], 150.7-212.1 mL) and preprocedural aneurysm diameter was 60.8 mm (95% CI, 57.8-63.9 mm). The target lumen volume was 56.3 mL (95% CI, 46.9-65.8 mL). Technical success was 100% and the ratio of SMP fully expanded volume to estimated target lumen volume was 1.4 ± 0.3. Baseline normalized sac volume and diameter were 140.7 mL (95% CI, 126.6-154.9 mL) and 61.0 mm (95% CI, 59.7-62.3 mm). The adjusted mean percentage change in normalized volume at 1 year was -28.8% (95% CI, -35.3 to -22.3%; P < .001). The adjusted mean change in sac diameter at 1 year was -5.9 mm (95% CI, -7.5 to -4.4 mm; P < .001). At 1 year, 81.8% of patients (95% CI, 64.5%-93.0%) achieved a ≥10% decrease in normalized volume and 57.6% of patients (95% CI, 39.2%-74.5%) achieved a ≥5 mm decrease in diameter. No device- or study procedure-related major adverse events occurred through 1 year after the procedure. CONCLUSIONS: Treatment of AAA sacs with SMP devices during EVAR resulted in significant sac volume and diameter regression at 1 year with an acceptable safety profile in this prospective study.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Feminino , Prótese Vascular , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Estudos Prospectivos , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Seguimentos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Fatores de Risco
4.
N Engl J Med ; 390(1): 9-19, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-37888915

RESUMO

BACKGROUND: Among patients with chronic limb-threatening ischemia (CLTI) and infrapopliteal artery disease, angioplasty has been associated with frequent reintervention and adverse limb outcomes from restenosis. The effect of the use of drug-eluting resorbable scaffolds on these outcomes remains unknown. METHODS: In this multicenter, randomized, controlled trial, 261 patients with CLTI and infrapopliteal artery disease were randomly assigned in a 2:1 ratio to receive treatment with an everolimus-eluting resorbable scaffold or angioplasty. The primary efficacy end point was freedom from the following events at 1 year: amputation above the ankle of the target limb, occlusion of the target vessel, clinically driven revascularization of the target lesion, and binary restenosis of the target lesion. The primary safety end point was freedom from major adverse limb events at 6 months and from perioperative death. RESULTS: The primary efficacy end point was observed (i.e., no events occurred) in 135 of 173 patients in the scaffold group and 48 of 88 patients in the angioplasty group (Kaplan-Meier estimate, 74% vs. 44%; absolute difference, 30 percentage points; 95% confidence interval [CI], 15 to 46; one-sided P<0.001 for superiority). The primary safety end point was observed in 165 of 170 patients in the scaffold group and 90 of 90 patients in the angioplasty group (absolute difference, -3 percentage points; 95% CI, -6 to 0; one-sided P<0.001 for noninferiority). Serious adverse events related to the index procedure occurred in 2% of the patients in the scaffold group and 3% of those in the angioplasty group. CONCLUSIONS: Among patients with CLTI due to infrapopliteal artery disease, the use of an everolimus-eluting resorbable scaffold was superior to angioplasty with respect to the primary efficacy end point. (Funded by Abbott; LIFE-BTK ClinicalTrials.gov number, NCT04227899.).


Assuntos
Angioplastia , Implante de Prótese Vascular , Isquemia Crônica Crítica de Membro , Stents Farmacológicos , Doença Arterial Periférica , Artéria Poplítea , Humanos , Implantes Absorvíveis , Angioplastia/efeitos adversos , Angioplastia/métodos , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos , Implante de Prótese Vascular/métodos , Doença Crônica , Isquemia Crônica Crítica de Membro/etiologia , Isquemia Crônica Crítica de Membro/cirurgia , Everolimo/administração & dosagem , Everolimo/efeitos adversos , Everolimo/uso terapêutico , Imunossupressores/administração & dosagem , Imunossupressores/efeitos adversos , Imunossupressores/uso terapêutico , Isquemia/tratamento farmacológico , Isquemia/etiologia , Isquemia/cirurgia , Doença Arterial Periférica/complicações , Doença Arterial Periférica/tratamento farmacológico , Doença Arterial Periférica/cirurgia , Artéria Poplítea/cirurgia , Alicerces Teciduais , Resultado do Tratamento
5.
J Vasc Interv Radiol ; 35(2): 232-240.e1, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37931844

RESUMO

PURPOSE: A prospective, single-arm, open-label, multicenter, first-in-human, early feasibility study was completed to evaluate the safety and performance of the GPX Embolic Device (Fluidx, Salt Lake City, Utah), a novel liquid embolic agent, for use in the peripheral vasculature when deep distal embolization is desired. MATERIALS AND METHODS: The early feasibility study evaluated the use of the device in the peripheral vasculature. Enrollment consisted of 17 patients with diverse embolization needs requiring deep distal vessel/vessel bed occlusion. Technical success, freedom from adverse events (AEs), and handling/performance characteristics were assessed with follow-up at 30 days. RESULTS: The trial enrolled 17 patients requiring distal vascular penetration of the embolic agent, including 7 with renal angiomyolipomas, 4 with renal cell carcinomas (primary and secondary), 4 with portal veins needing embolization, 1 with pelvic sarcoma, and 1 with polycystic kidney. In all cases (100%), technical success was achieved with target regions fully occluded on the first angiogram (taken immediately after delivery). Furthermore, the material received high usability ratings, as measured by a postprocedural investigator questionnaire. Most patients (15/17, 88.2%) were free from device-related severe AEs, and there were no unanticipated AEs during the study. Each patient completed a 30-day follow-up evaluation, and sites remained fully occluded in each case where imaging was available (6 [35.3%] of 17 patients had follow-up imaging where all sites were deemed occluded [100%] with a mean of 30.2 days after the procedure). CONCLUSIONS: The results of this first-in-human, early feasibility study demonstrate that the GPX Embolic Device may provide safe and effective embolization for arterial or venous applications where deep distal penetration is desired.


Assuntos
Embolia , Embolização Terapêutica , Líquidos Iônicos , Humanos , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Estudos Prospectivos , Resultado do Tratamento
6.
JMIR Res Protoc ; 12: e51480, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38048145

RESUMO

BACKGROUND: The recommendations for the use of and selection of covered stent grafts in patients with aortoiliac occlusive disease are limited. OBJECTIVE: The GORE VBX FORWARD clinical study aims to demonstrate the superiority of the GORE VIABAHN VBX Balloon Expandable Endoprosthesis (VBX device) for primary patency when compared to bare metal stenting (BMS) for the treatment of complex iliac artery occlusive disease. METHODS: A prospective, multicenter, randomized control study in the United States, European Union, United Kingdom, Australia, and New Zealand will enroll patients with symptomatic, complex iliac artery occlusive disease. In this study, iliac artery occlusive disease is defined as a unilateral or bilateral disease with single or multiple lesions (with >50% stenosis or chronic total occlusion) each between 4 and 11 cm in length. In an attempt to more closely match real-world practices, patients with minor tissue loss (Rutherford class 5) and patients requiring hemodialysis will be included. Baseline aortoiliac angiography will be performed to assess target lesion characteristics and determine final patient eligibility. Once the patient is confirmed and guidewires are in place across the target lesions, the patient will be randomized in a 1:1 format to treatment with either the VBX device or a BMS. The BMS can be balloon- or self-expanding and must be approved for the iliac artery occlusive disease indication. Patients, the independent core laboratory reviewers, and Clinical Events Committee members will be blinded from the assigned treatment. Dual antithrombotic medical therapy is required through a minimum of 3 months post procedure. The primary end point is 12­month primary patency and will be adjudicated by an independent imaging core laboratory and Clinical Events Committee. Key secondary end points will be tested for superiority and include technical, acute procedural, and clinical success; changes in Ankle-brachial index; patient quality of life; primary patency; freedom from restenosis; primary-assisted patency; secondary patency; freedom from target lesion revascularizations; cumulative reintervention rate; amputation-free survival; survival; and change in Rutherford category. Study follow-up will continue through 5 years. RESULTS: Outcomes will be reported following study completion. Enrollment is anticipated to start in October 2023. CONCLUSIONS: The results of this study will provide definitive, level 1 clinical evidence to clinicians on the optimal choice of stent device to use for the treatment of complex iliac artery occlusive disease. The FORWARD study is powered for superiority and includes only complex, unilateral, or bilateral lesions involving the common or external iliac arteries. This study is a multidisciplinary endeavor involving vascular surgery, interventional cardiology, and interventional radiology across multiple countries with a blinded core laboratory review of end points in hopes that the outcomes will be widely accepted and incorporated into practice guidelines for optimal treatment of patients with complex iliac artery occlusive disease. TRIAL REGISTRATION: ClinicalTrials.gov NCT05811364; https://clinicaltrials.gov/study/NCT05811364. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): PRR1-10.2196/51480.

7.
JACC Cardiovasc Interv ; 16(13): 1654-1664, 2023 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-37438033

RESUMO

BACKGROUND: Hypoechoic peri-stent areas in duplex ultrasonography (DUS) (ie, "halo") have been noted following femoropopliteal artery stenting. OBJECTIVES: This study sought to investigate the prevalence, risk factors, and potential safety implications of hypoechoic halos identified with DUS following stent implantation in the IMPERIAL (ELUVIA Drug-Eluting Stent Versus Zilver PTX Stent) and EMINENT (Trial Comparing ELUVIA Versus Bare Metal Stent in Treatment of Superficial Femoral and/or Proximal Popliteal Artery) trials. METHODS: The IMPERIAL and EMINENT studies of femoropopliteal artery stenting included polymer-based drug-eluting stent, nonpolymer drug-coated stent, and bare metal stent treatment arms. A dedicated DUS protocol was implemented for core laboratory assessment of halo presence at study follow-up visits. Logistic regressions were used to investigate risk factors for a halo sign and its impact on clinically driven target lesion revascularization and primary patency. RESULTS: Diagnostic DUS imaging from 659 patients was obtained at time points ranging from 6 months to 5 years post-stent implantation. Halo prevalence ranged from 20% to 35% of patients with diagnostic DUS and was present at all time intervals. Halos were identified surrounding all stent types. In analyses of patients with diagnostic imaging from at least 2 visits, halo presence typically persisted, with occasional cases of regression and development at later times. No statistically significant association was found for halo status (ie, halo vs no halo) on 1-year clinically driven target lesion revascularization (OR: 1.27; 95% CI: 0.70-2.30; P = 0.4240) or primary patency (OR: 0.68; 95% CI: 0.43-1.07; P = 0.0927). CONCLUSIONS: A hypoechoic halo following a femoropopliteal stent procedure is a common occurrence associated with all studied stent types. The presence of a halo appears to be benign with no associated clinical sequelae or effect on target vessel revascularization rates within 1 year of stent implantation.


Assuntos
Stents Farmacológicos , Humanos , Resultado do Tratamento , Artéria Femoral/diagnóstico por imagem , Fatores de Risco , Stents
8.
J Vasc Surg Cases Innov Tech ; 9(3): 101241, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37496654

RESUMO

Preprocedural image analysis and intraprocedural techniques to fully treat infrarenal abdominal aortic aneurysm sacs outside of the endograft with shape memory polymer (SMP) devices during endovascular aneurysm repair were developed. Prospective, multicenter, single-arm studies were performed. SMP is a porous, self-expanding polyurethane polymer material. Target lumen volumes (aortic flow lumen volume minus endograft volume) were estimated from the preprocedural imaging studies and endograft dimensions. SMP was delivered immediately after endograft deployment via a 6F sheath jailed in a bowed position in the sac. Technical success was achieved in all cases, defined as implanting enough fully expanded SMP volume to treat the actual target lumen volume.

9.
J Vasc Interv Radiol ; 34(12): 2093-2102.e7, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37460061

RESUMO

PURPOSE: To present the 36-month outcomes of the prospective randomized IN.PACT AV Access study of participants with obstructive de novo or restenotic native upper extremity arteriovenous dialysis fistula lesions treated with drug-coated balloon (DCBs) or standard percutaneous transluminal angioplasty (PTA) following successful high-pressure PTA. MATERIALS AND METHODS: Participants at 29 international sites were randomized 1:1 to receive an IN.PACT AV DCB (n = 170) or undergo PTA (n = 160). The outcomes through 36 months included target lesion primary patency (TLPP) and access circuit primary patency (ACPP) (composites of clinically driven target lesion or access circuit revascularization and/or access circuit thrombosis), number of reinterventions, and serious adverse events involving the access circuit. RESULTS: TLPP was 52.1% in the DCB group compared with 36.7% in the PTA group through 24 months and 43.1% in the DCB group compared with 28.6% in the PTA group through 36 months (both log-rank P < .001). ACPP was 39.4% in the DCB group compared with 25.3% in the PTA group through 24 months and 26.4% in the DCB group compared with 16.6% in the PTA group through 36 months (both log-rank P < .001). Cumulative incidence of access circuit thrombosis through 36 months was 8.2% in the DCB group compared with 18.3% in the PTA group (log-rank P = .040). Cumulative incidence of mortality through 36 months was 26.6% in the DCB group compared with 30.8% in the PTA group (log-rank P = .71). CONCLUSIONS: This study demonstrated superior TLPP and ACPP with DCBs compared with PTA, with no difference in mortality through 3 years. Access circuit thrombosis was statistically significantly higher in the PTA group at 3 years.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Trombose , Dispositivos de Acesso Vascular , Humanos , Angioplastia com Balão/efeitos adversos , Artéria Femoral , Artéria Poplítea , Estudos Prospectivos , Materiais Revestidos Biocompatíveis , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Fatores de Tempo , Método Simples-Cego , Grau de Desobstrução Vascular , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/terapia , Resultado do Tratamento
10.
J Endovasc Ther ; : 15266028231179589, 2023 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-37314243

RESUMO

BACKGROUND: The randomized Chocolate Touch Study demonstrated that in patients undergoing treatment of femoropopliteal artery lesions, the Chocolate Touch drug-coated balloon (DCB) was safe and had superior efficacy at 12 months compared with the Lutonix DCB. We report the prespecified diabetes subanalysis comparing outcomes among patients with and without diabetes mellitus (DM). METHODS: Patients with claudication or ischemic rest pain (Rutherford class 2-4) were randomized to Chocolate Touch or Lutonix DCB. The primary efficacy endpoint was DCB success defined as primary patency at 12 months (peak systolic velocity ratio <2.4 by duplex ultrasound without clinically driven target lesion revascularization in the absence of bailout stenting). The primary safety endpoint was freedom from major adverse events at 12 months, a composite of target limb-related death, major amputation, or reintervention. RESULTS: A total of 313 patients (38% DM [n=119]) were randomized to either Chocolate Touch (n=66/152) or Lutonix DCB (n=53/161). Among patients with DM, DCB success was 77.2% and 60.5% (p=0.08), and in non-DM patients, DCB success was 80% and 71.3% (p=0.2114) for the Chocolate Touch and Lutonix DCB, respectively. The primary safety endpoint was similar for both cohorts regardless of DM status (interaction test, p=0.96). CONCLUSIONS: This randomized trial demonstrated similar safety and efficacy for the treatment of femoropopliteal disease with the Chocolate Touch DCB compared with using the Lutonix DCB regardless of DM status at 12 months. CLINICAL IMPACT: This substudy of the Chocolate Touch Study demonstrated similar safety and efficacy for treatment of femoropopliteal disease of the Chocolate Touch DCB compared with the Lutonix DCB regardless of diabetes (DM) status at 12 months. Endovascular therapy has become the therapy of choice for the treatment of most symptomatic femoropopliteal lesions regardless of DM status. These results give clinicians another option when treating femoropopliteal disease in this high-risk patient population.

11.
J Vasc Surg ; 78(4): 929-935.e1, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37330148

RESUMO

OBJECTIVE: There is no proven therapy to reduce growth rates of small- to medium-sized abdominal aortic aneurysms (AAAs). Ex vivo and animal studies have demonstrated that a novel stabilizing agent, 1,2,3,4,6-pentagalloyl glucose (PGG), delivered locally to the aneurysm sac, can bind to elastin and collagen to re-establish strength and resist enzymatic degradation. We aimed to demonstrate that a one-time administration of PGG solution to the aneurysm wall is safe and potentially effective to slow the growth of small- to medium-sized AAAs. METHODS: Patients with small- to medium-sized infrarenal AAAs (maximum diameter <5.5 cm) were recruited. Via transfemoral access, a 14F or 16F dual-balloon delivery catheter was introduced into the aneurysm sac. A single, 3-minute, localized endoluminal infusion of PGG was delivered via a 'weeping' balloon to the aneurysm wall. Independent core laboratory measurements of maximum aneurysm sac diameter and sac volume measurements based on computed tomography angiography (CTA) were used for assessments at 1, 6, 12, 24, and 36 months. The primary endpoints were technical success and safety (major adverse events at 30 days). The secondary endpoint was growth stabilization, defined as freedom from aneurysm sac enlargement (diameter increase >5 mm per year or volume increase of >10% per year). RESULTS: Twenty patients (19 male) were enrolled at five centers from May 2019 to June 2022 (mean age, 67.8 years; range, 50-87 years). All procedures were technically successful. The safety profile was consistent with standard interventional procedures. Four patients demonstrated transient elevations of liver enzymes levels that returned to normal by 30 days with no clinical symptoms. Through November 2022, follow-up CTA data is available on the first 11 patients. The average changes in maximum aneurysm diameter from baseline to 6, 12, 24, and 36 months were 0.2 mm, 1.1 mm, 1.2 mm, and 0.8 mm, respectively, and the average changes in volume were 2.0%, 9.6%, 18.1%, and 11.6%, respectively. At 12 months, none of the aneurysms showed growth >5.0 mm, and three had volume growth >10%. CONCLUSIONS: The early results of this first-in-human, small cohort study demonstrated that a single, localized PGG administration to patients with small- to medium-sized infrarenal AAAs is safe. Longer term follow-up on all 20 treated patients is needed to better assess the potential impact on aneurysm growth.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Idoso , Projetos Piloto , Estudos de Coortes , Aorta Abdominal , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Tomografia Computadorizada por Raios X , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Prótese Vascular , Desenho de Prótese
12.
J Vasc Interv Radiol ; 34(10): 1664-1673.e3, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37302473

RESUMO

PURPOSE: To use safety and efficacy outcomes following treatment with percutaneous transluminal angioplasty (PTA) and/or stent placement for thoracic central venous obstruction in hemodialysis-dependent patients to establish objective performance goals (OPGs). METHODS: A systematic literature review and meta-analysis were conducted for articles published between January 1, 2000, and August 31, 2021. Efficacy outcomes included primary patency rates at 6 and 12 months, and safety outcomes included adverse events (AEs) categorized as access loss, procedure-related AEs, and serious AEs (SAEs). OPGs were derived from the upper and lower bounds of the 95% confidence intervals for primary patency and SAE rates. RESULTS: Of 66 articles reviewed, 17 met the inclusion criteria (PTA, n = 4; stent placement, n = 5; PTA/stent, n = 8). The 6- and 12-month primary patency rates for PTA were 50.9% and 36.7%, respectively. Based on these findings, the proposed 6- and 12-month primary patency OPGs identifying superiority against PTA were 66.5% and 52.6%, respectively, and those for noninferiority were 39.0% and 25.7%, respectively. For stent placement, the 6- and 12-month primary patency rates were 69.7% and 47.9%, respectively. The proposed 6- and 12-month primary patency OPGs identifying superiority were 82.1% and 64.1%, respectively, and those for noninferiority were 59.3% and 35.8%, respectively. SAE rates for PTA and stent placement were 3.8% and 8.1%, respectively. Proposed safety OPGs for noninferiority versus superiority for PTA and stent placement were 10.1% versus 1.4% and 13.6% versus 4.8%, respectively. CONCLUSION: The OPGs derived from real-world studies of PTA and stent placement may serve as a benchmark for future interventions indicated for this patient population.


Assuntos
Angioplastia com Balão , Doenças Vasculares , Humanos , Objetivos , Angioplastia com Balão/efeitos adversos , Grau de Desobstrução Vascular , Angioplastia , Doenças Vasculares/terapia , Stents , Diálise Renal , Resultado do Tratamento
13.
Vascular ; : 17085381231177851, 2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37218283

RESUMO

OBJECTIVES: Porous, radiolucent, shape memory polymer is a new technology available in discrete peripheral vascular embolization devices. Shape memory polymers can exist in two stable shapes; crimped for catheter delivery and expanded for vessel embolization. The expanded shape memory polymer in these new devices is hemostatic, and the porous polymeric scaffold has been shown to support tissue ingrowth and eventually bioabsorbs in preclinical animal studies. This report describes clinical experience with this novel material in vascular plug devices. METHODS: a prospective, single-arm, safety study at a single center in New Zealand with longer term follow-up via retrospective imaging review. The study device was a pushable shape memory polymer vascular plug with a distal nitinol anchor coil and a proximal radiopaque marker. RESULTS: Ten male patients were each implanted with a single shape memory polymer vascular plug. Three inferior mesenteric arteries and an accessory renal artery were embolized during endovascular aneurysm repair. An internal iliac artery was treated prior to the open surgical repair of aorto-iliac aneurysms. An internal iliac artery and a subclavian artery were embolized to treat/prophylactically address potential endoleaks. A profunda branch was embolized prior to tumor resection, and two testicular veins were embolized to treat varicoceles. Acute technical success of target vessel embolization was achieved in all implantation cases. Patients were followed for 30 days as part of the study, and no serious adverse events with a relationship to the study device occurred. No recurrent clinical symptoms attributable to treated vessel embolization or recanalization were documented. There was no evidence of recanalization on retrospective review of follow-up imaging through a mean of 22.2 months (range, <1-44 months) post-procedure. CONCLUSIONS: Shape memory polymer vascular embolization devices were safe and effective over the follow-up period of this small safety study. Further experience and longer term follow-up will assess further applicability.

14.
J Endovasc Ther ; : 15266028231165723, 2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37073512

RESUMO

INTRODUCTION: This physician-initiated study provides 5-year (i.e., long-term) treatment durability data from 3 top recruitment sites that participated in the prospective, multicenter, nonrandomized, single-arm VBX FLEX clinical study (ClinicalTrials.gov identifier: NCT02080871). It evaluates the long-term treatment durability of the GORE VIABAHN VBX Balloon Expandable Endoprosthesis (VBX Stent-Graft) in the treatment of subjects with de novo or restenotic aortoiliac lesions. MATERIALS AND METHODS: A total of 59 subjects with 94 treated lesions were enrolled at the 3 participating sites from the original 140 intent-to-treat subjects in the VBX FLEX study. The primary durability endpoint was long-term primary patency. Secondary long-term outcomes included freedom from target lesion revascularization (TLR), freedom from target vessel revascularization (TVR), as well as resting ankle-brachial index (ABI), Rutherford category, EuroQol 5 Dimensions, and Walking Impairment status. RESULTS: Fifty-nine subjects participated and twenty-eight (47.5%) were available through the end of the study at 5-year follow-up (the median follow-up time was 6.6 years due to complications resulting from COVID-19 precautions). At 3 and 5 years, the Kaplan-Meier estimates for freedom from all-cause mortality were 94.5% and 81.7%, respectively. The Kaplan-Meier estimates for primary patency at 3 and 5 years were 94.0% and 89.5% (by lesion) and 91.7% and 84.4% (by subject). Primary assisted patency at 3 and 5 years were 93.3% and 93.3%. Kaplan-Meier estimate for freedom from TLR at 5 years was 89.1%. The majority of subjects were asymptomatic (Rutherford category 0) at 3 years (29/59; 72%), and at 5-year follow-up (18/28; 64%). The 5-year mean resting ankle-brachial index was 0.95±0.18, an improvement of 0.15±0.26 from the baseline (p<0.001). Quality of life measures also showed sustained improvement through long-term follow-up. CONCLUSION: The 5-year long-term follow-up data underscore the robustness and durability of the Viabahn Balloon-Expandable Endoprosthesis for treating aortoiliac occlusive disease. CLINICAL IMPACT: Durable improvement after endovascular treatment of iliac occlusive disease is clinically important because many of these patients are claudicants with significant life expectancy. This study is the first to evaluate the long-term outcomes in patients with iliac occlusive disease treated with the Viabahn VBX balloon-expandable endopirostheses. The study reports excellent long-term patency outcomes with prolonged clinical benefit. These durable results are likely to be an important consideration for clinicians undertaking iliac artery revascularization procedures.

15.
Cardiovasc Intervent Radiol ; 46(1): 100-111, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36450994

RESUMO

PURPOSE: To assess occlusion success and adverse events associated with the use of a self-expanding device for peripheral artery embolization. METHODS: This prospective, single-arm, feasibility study was conducted using the Caterpillar™ Arterial Embolization Device composed of opposing nitinol fibers and a flow-occluding membrane. Twenty patients (24 embolization sites) were treated at four investigational centers in New Zealand and Australia and followed for 30 days. Embolization sites included mesenteric, accessory renal, and iliac arteries and their branches. Primary outcome measures were peri-procedural occlusion confirmed by angiography and freedom from device-related serious adverse events (SAEs) at 30 days. Secondary observations included time to occlusion and assessment of adverse events. RESULTS: Peri-procedural occlusion was 100%, and freedom from a device-related SAE was 94.7% at 30 days. One patient had abdominal bloating that required hospitalization deemed possibly related to the device or procedure. Twenty-two of 24 embolization sites were occluded with one device (91.7%). Mean procedure duration was 11.7 ± 8.6 min (device deployment time: 1.8 ± 1.0 min), and mean fluoroscopy time was 241 ± 290.7 s. All embolization sites occluded during the procedure with 62.5% occluded within three minutes and 91.6% occluded within ten minutes. No devices migrated or required re-embolization. Freedom from device- and procedure-related adverse events was 84.2%. One patient died from aortic rupture during a subsequent adjunctive abdominal aortic endovascular procedure deemed unrelated to the embolization device or procedure. CONCLUSIONS: This first-in-human study of the Caterpillar embolization device achieved peri-procedural occlusion in all patients with a 94.7% freedom from device-related SAE at 30 days. LEVEL OF EVIDENCE: Level 2b-prospective, multicenter, single-arm, first-in-human clinical study. Pre-specified endpoints were analyzed using descriptive statistics.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Humanos , Prótese Vascular , Stents , Estudos Prospectivos , Resultado do Tratamento , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Abdominal/cirurgia
16.
Vascular ; 31(2): 234-243, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34963378

RESUMO

OBJECTIVE: Practice patterns and durability of parallel stent graft techniques in complex endovascular aneurysm repair (EVAR) remain poorly defined. We aimed to quantify and compare the impact of renal chimney intra-aortic stent length (IASL) on geometric deformations of renal arteries in complex EVAR. METHODS: Thirty-eight nonconsecutive patients underwent EVAR utilizing parallel stent graft techniques (chimney EVAR [chEVAR], n = 28; chimney endovascular aneurysm sealing [chEVAS], n = 10) between 2010 and 2016. A total of 59 renal chimney stent grafts were used. Geometric quantification was derived from three-dimensional model-based centerline extraction. Renal chimney intra-aortic stent length (IASL) was defined as the length of chimney stent that extended from the proximal edge of the chimney stent to the ostium of the corresponding renal artery. RESULTS: Mean IASL for both left and right renal arteries in the cohort was 35.7 mm. Renal arteries containing chimney IASL <30 mm trended toward a greater branch angle (135.4 vs. 127.8°, p = .06). Left renal arteries showed significantly greater branch angle among those with IASL <40 mm (135.5 vs. 121.7°, p = .045). Mean IASL for renal arteries in chEVAR was significantly longer compared to chEVAS (39.2 vs. 26.3 mm, p = .003). No difference was noted in overall branch angle or end-stent angle based on procedure type. ChEVAR with IASL <30 mm had significantly greater end-stent angle (48.2 vs. 33.5°, p = .03). In contrast, chEVAS patients showed no difference in end-stent angle based on IASL thresholds, but did have significantly greater branch angle among those with IASL <30 mm when grouped by both all renal arteries (133.5 vs. 113.5°, p = .004) and right renal arteries (134.3 vs. 111.6°, p = .02). CONCLUSIONS: Renal chimney stents with longer IASL appear to exhibit less renal artery deformation, suggesting a more gradual and perpendicular transition of the chimney stent across the renal ostium.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Correção Endovascular de Aneurisma , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Aortografia/métodos , Stents , Desenho de Prótese
17.
Ann Surg ; 277(2): e460-e466, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33714965

RESUMO

OBJECTIVE: To assess the initial clinical experience with a novel endograft system (NEXUS Aortic Arch Stent Graft System) designed to treat aortic arch pathologies and address the morphology and hemodynamic challenges of the aortic arch. SUMMARY BACKGROUND DATA: The aortic arch remains the most challenging part of the aorta for both open and endovascular repair. Transcatheter aortic arch repair has the potential to significantly reduce surgical risks. METHODS: Patients underwent transcatheter aortic arch repair with a single branch, 2 stent graft system, implanted over a through-and-through guidewire from the brachiocephalic trunk, to the descending aorta with an ascending aorta stent graft. The ascending aorta stent graft is deployed into a designated docking sleeve to connect the 2 stent grafts and isolate the aortic arch pathology. Proximal landing zone in all cases was in Zone 0. Anatomical inclusion criteria included adequate landing zone in the ascending aorta, brachiocephalic trunk, and descending thoracic aorta. Preparatory debranching procedure was performed in all patients with carotid-carotid crossover bypass and left carotid to left subclavian bypass, or parallel graft from descending aorta to left subclavian artery. Safety and performance were evaluated through 1 year. Survival analysis used the Kaplan-Meier method. RESULTS: Twenty-eight patients, 79% males, with a mean age of 72.2 ± 6.2 years were treated with 100% procedural success. Isolated aortic arch aneurysm was the principle pathology in 17 (60.7%) of patients, while chronic aortic dissection was the principle pathology in 6 (21.4%) of patients. The remaining 5 (17.8%) had combined or other pathologies. At 1 month, the vascular pathology was excluded in 25 of 26 alive patients (96.1%). The 30 days mortality rate was 7.1%, stroke rate was 3.6% (all nondisabling), and combined mortality/stroke rate was 10.7%. One-year mortality was 10.7%, without device or aneurysm-related death. Two patients (7.1%) reported stroke or transient ischemic attack at 1 year that recovered completely. One year combined mortality/stroke rate was 17.8%. There were 3 patients (10.7%) that had device-related unplanned reinterventions through 1 year. CONCLUSIONS: The NEXUS Aortic Arch Stent Graft System, a novel single branch, 2 stent graft system used for endovascular aortic arch repair that requires landing in the ascending aorta, demonstrates a high success rate with excellent 1 year safety and performance.


Assuntos
Dissecção Aórtica , Acidente Vascular Cerebral , Masculino , Humanos , Idoso , Feminino , Aorta Torácica/cirurgia , Aorta , Stents , Dissecção Aórtica/cirurgia
18.
Eur J Cardiothorac Surg ; 63(1)2022 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-36484696

RESUMO

OBJECTIVES: Endovascular aortic arch stent grafting with branched devices has shown initial promising results. The aim of this prospective, multicentre study was to evaluate 3-year outcomes of aortic arch stent grafting with NEXUS® Aortic Arch Stent Graft System (Nexus), a single-branch, bi-modular, off-the-shelf aortic arch stent graft system in high-risk patients. METHODS: Patients treated with Nexus, either under the feasibility clinical study or as compassionate use procedures in 5 centres, were included in this study. The primary end point was overall survival. The secondary end points included the incidence of procedure-related unplanned intervention, stroke, paraplegia and endoleak. Clinical and radiologic follow-up was performed at each study site at 30 days, 6 months and on a yearly basis thereafter up to 3 years postoperatively. RESULTS: We analysed data from a total of 28 patients. The overall median follow-up was 1132 (interquartile range: 809-1537). There were no device or procedure-related deaths between 1 and 3 years. Overall survival at 1 and 3 years was 89% and 71%, respectively. The cumulative incidence of unplanned reintervention at 1 and 3 years was 11% and 29%, respectively. There were no reports of stroke, paraplegia, aneurysm rupture, myocardial infarction or new aortic valve insufficiency. In this study's 1-3 year follow-up period, 1 type Ib (4%), 1 type II (4%) and 2 type III (8%; between Nexus' distal end and Thoracic endovascular aortic repair (TEVAR) extensions) endoleak were detected. CONCLUSIONS: Endovascular aortic arch exclusion with the single-branch, off-the-shelf Nexus system provides promising clinical and radiologic results at 3-year follow-up in a high-risk patient cohort.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Prótese Vascular/efeitos adversos , Endoleak/epidemiologia , Endoleak/etiologia , Correção Endovascular de Aneurisma , Seguimentos , Estudos Prospectivos , Complicações Pós-Operatórias , Stents/efeitos adversos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Estudos Retrospectivos
19.
Nephrology (Carlton) ; 27(11): 859-868, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36068700

RESUMO

AIM: The recent IN.PACT AV Access study found drug-coated balloon therapy to be associated with reduced reinterventions compared to percutaneous transluminal angioplasty using standard balloons in the management of arteriovenous fistula stenosis. The economic implications of drug-coated balloon use in Asia, including Japan and Korea, remain unknown. METHODS: A decision-analytic model was developed to calculate strategy-specific costs for Korea and Japan through 5-year follow-up. The analysis assumed maintained therapy benefit beyond current trial follow-up of 1 year in the base case, with several alternative scenarios explored in sensitivity analysis. Costs were derived from claims and reimbursement data, and projections were evaluated at 3 and 5 years post-index procedure. RESULTS: Model-projected access circuit reintervention events for drug-coated versus standard balloons were 1.70 versus 2.76 (-1.06) and 2.53 versus 4.10 (-1.57) at 3 and 5 years in the base case. Corresponding 3- and 5-year costs were ₩6 211 103 versus ₩7 605 553 (-₩1 394 451) and ₩7 766 051 versus ₩10 124 954 (-₩2 358 904) in Korea, and ¥1 469 824 versus ¥1 504 161 (-¥34 337) and ¥1 956 931 versus ¥2 106 632 (-¥149 701) in Japan. In scenario analyses, drug-coated balloons remained cost saving at 3- and 5-year follow-up in Korea, but required up to 5 years to reach cost-savings in Japan. Drug-coated balloon use in reinterventions increased projected savings, as did younger treatment age. CONCLUSION: Treatment of arteriovenous fistulas with the IN.PACT AV drug-coated balloon, based on preliminary data, may lead to meaningful reductions in reintervention costs that would render it cost-saving at timeframes of around 1 year in Korea and between 3 and 5 years in Japan.


Assuntos
Angioplastia com Balão , Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Fármacos Cardiovasculares , Angioplastia com Balão/métodos , Materiais Revestidos Biocompatíveis , Constrição Patológica , Humanos , Japão , Paclitaxel , Diálise Renal/métodos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
20.
J Vasc Interv Radiol ; 33(12): 1559-1569.e2, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36084842

RESUMO

PURPOSE: To assess the safety and effectiveness of transarterial radioembolization (TARE) in the treatment of hepatic metastases from pancreatic ductal adenocarcinoma (PDAC). MATERIALS AND METHODS: A systematic search of the Embase and MEDLINE databases was conducted using keywords and Medical Subject Headings terms related to TARE and hepatic metastases from PDAC. Observational studies and clinical trials reporting overall survival (OS), hepatic progression-free survival (hPFS), or tumor response after TARE were included. RESULTS: Eight studies, comprising 145 patients with metastatic PDAC, met the inclusion criteria. No randomized controlled trials were identified, and 4 studies were prospective. Forty-four (30.3%) patients underwent previous pancreatic resection, and 66 (45.5%) had extrahepatic metastases at the time of TARE. Most studies (n = 6) used resin microspheres for TARE. The pooled disease control rate was 69.4% at a median of 3 months. The median OS from the time of TARE ranged from 3.7 to 9 months. The median hPFS ranged from 2.4 to 5.2 months. There were 31 Grade 3-4 biochemical toxicities and 4 treatment-related deaths. CONCLUSIONS: The role of TARE in patients with hepatic metastases from PDAC remains unclear owing to low patient numbers, limited prospective data, and heterogeneity in the study design. Further prospective studies are required to evaluate the role of TARE in carefully selected patients with liver-only metastatic disease.


Assuntos
Adenocarcinoma , Carcinoma Hepatocelular , Carcinoma Ductal Pancreático , Embolização Terapêutica , Neoplasias Hepáticas , Neoplasias Pancreáticas , Humanos , Radioisótopos de Ítrio/efeitos adversos , Adenocarcinoma/terapia , Neoplasias Pancreáticas/patologia , Resultado do Tratamento , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/patologia , Embolização Terapêutica/efeitos adversos , Carcinoma Hepatocelular/terapia , Estudos Retrospectivos , Neoplasias Pancreáticas