Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Health Promot Int ; 34(1): 113-122, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29040581

RESUMO

Health promotion intervention in schools is a useful strategy to improve students' health awareness. The purpose of this study was to assess the effect of eye health promotion interventions on eye health literacy in school children in Vietnam. A piloted questionnaire was administered to 300 children from five secondary schools in Ba Ria-Vung Tau, Vietnam at baseline and re-administered after the eye health promotion interventions. McNemar chi-square and logistic regression were used for statistical analysis. A total of 300 children aged 12-15 years (mean, 13.3 ± 1.3 years; 60% female) participated in the baseline survey. The participation rate in the post-health promotion survey was 94.7%. After the health promotion interventions, number of children who had correct eye health knowledge increased by 10-20% (60-75% to 70-95%), more children reported having had an eye examination (63.3% to 84.7%; p < 0.001) and more reported wearing spectacles (36.1% to 43.4%; p = 0.04). Children in urban schools were twice as likely to have improved knowledge of vision loss compared with children in rural schools (odds ratio, 2.1-4.1; p = 0.01 to p < 0.001). Children from rural schools had significantly higher odds of visiting doctor after the eye problems worsened (odds ratio, 4.5; p < 0.001). These results imply that eye health promotion interventions significantly improve eye health knowledge, attitudes and practices of school children. Additionally, participation of parents and teachers as change agents may further improve children's health literacy.


Assuntos
Saúde da Criança , Olho , Serviços de Saúde Escolar , Estudantes/estatística & dados numéricos , Seleção Visual/métodos , Adolescente , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Letramento em Saúde , Humanos , Masculino , População Rural , Inquéritos e Questionários , Vietnã
2.
Clin Exp Optom ; 100(6): 683-689, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27862287

RESUMO

PURPOSE: The aim was to develop and validate an instrument to measure job satisfaction in eye-care personnel and assess the job satisfaction of one-year trained vision technicians in India. METHODS: A pilot instrument for assessing job satisfaction was developed, based on a literature review and input from a public health expert panel. Rasch analysis was used to assess psychometric properties and to undertake an iterative item reduction. The instrument was then administered to vision technicians in vision centres of Andhra Pradesh in India. Associations between vision technicians' job satisfaction and factors such as age, gender and experience were analysed using t-test and one-way analysis of variance. RESULTS: Rasch analysis confirmed that the 15-item job satisfaction in eye-care personnel (JSEP) was a unidimensional instrument with good fit statistics, measurement precisions and absence of differential item functioning. Overall, vision technicians reported high rates of job satisfaction (0.46 logits). Age, gender and experience were not associated with high job satisfaction score. Item score analysis showed non-financial incentives, salary and workload were the most important determinants of job satisfaction. CONCLUSIONS: The 15-item JSEP instrument is a valid instrument for assessing job satisfaction among eye-care personnel. Overall, vision technicians in India demonstrated high rates of job satisfaction.


Assuntos
Satisfação no Emprego , Assistentes de Oftalmologia/estatística & dados numéricos , Psicometria/instrumentação , Inquéritos e Questionários , Adulto , Feminino , Humanos , Índia , Masculino , Qualidade de Vida , Adulto Jovem
3.
Arq Bras Oftalmol ; 79(2): 73-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27224066

RESUMO

PURPOSE: To compare visual acuity (VA), contrast sensitivity, stereopsis, and subjective visual performance of Acuvue® Oasys® for Presbyopia (AOP), Air Optix® Aqua Multifocal (AOMF), and Air Optix® Aqua Single Vision (AOSV) lenses in patients with presbyopia. METHODS: A single-blinded crossover trial was conducted. Twenty patients with mild presbyopia (add ≤+1.25 D) and 22 with moderate/severe presbyopia (add ≥+1.50 D) who wore lenses bilaterally for 1 h, with a minimum overnight washout period between the use of each lens. Measurements included high- and low-contrast visual acuity (HCVA and LCVA, respectively) at a distance, contrast sensitivity (CS) at a distance, HCVA at intermediate (70 cm) and near (50 cm & 40 cm) distances, stereopsis, and subjective questionnaires regarding vision clarity, ghosting, overall vision satisfaction, and comfort. The test variables were compared among the lens types using repeated-measures ANOVA. RESULTS: Distance variables (HCVA, LCVA, and CS) were significantly worse with multifocal lens than with AOSV lens (p≤0.008), except for AOMF lens in the mild presbyopia group in which no significant difference was observed (p>0.05). Multifocal lenses had significantly greater HCVA at 40 cm than AOSV lens (p≤0.026). AOMF lens had greater intermediate HCVA than AOP lens (p<0.03). AOP lens demonstrated greater improvements in stereopsis than AOMF and AOSV lens in the moderate/severe presbyopia group (p≤0.03). Few significant differences in subjective variables were observed, with no significant difference in the overall vision satisfaction observed between lens types (p>0.05). The proportions of patients willing to buy AOSV, AOMF, and AOP lenses were 20%, 40%, and 50%, respectively, in the mild presbyopia group and 14%, 32%, and 23%, respectively, in the moderate/severe presbyopia group; however, these differences were not statistically significant (p≥0.159). CONCLUSIONS: Further development of multifocal lenses is required before significant advantages of multifocal lenses over single vision lens are observed in patients with presbyopia.


Assuntos
Lentes de Contato Hidrofílicas , Desenho de Equipamento , Presbiopia/reabilitação , Idoso , Sensibilidades de Contraste/fisiologia , Estudos Cross-Over , Percepção de Profundidade/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Presbiopia/classificação , Estudos Prospectivos , Método Simples-Cego , Inquéritos e Questionários , Testes Visuais , Acuidade Visual/fisiologia
4.
Br J Ophthalmol ; 100(12): 1697-1702, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27033693

RESUMO

PURPOSE: To describe a new combined myopia and glaucoma visual field classification system in order to report the visual field defects in a population of mostly young Chinese high myopes aged 7-70 years. METHODS: A total of 1434 visual fields (including confirmatory repeats of abnormal defects) from 487 high myopes (sphere ≤-6.0 D) were analysed from the prospective Zhongshan Ophthalmic Center-Brien Holden Vision Institute (ZOC-BHVI) High Myopia Registry Study. The predefined classification definitions covering high myopia and glaucoma categories were: normal, enlarged blind spot, abnormal suspect and abnormal with nine subtypes. Two independent graders reviewed the first 150 of 1434 fields for initial grading calibration and the remaining 1284 fields were used to assess intergrader agreement. For the percentage distribution of visual fields, the repeats and unreliable fields were excluded, leaving 894 fields. RESULTS: The intergrader agreement of this combined classification system was a κ value of 0.61 (95% CI 0.59 to 0.63). Among the 894 unique fields, the most common visual field was normal at 33.7% followed by enlarged blind spot at 25.6%. The per cent of 'arcuate-like' field defects (combining nasal step, early arcuate and advanced arcuate) was 16.1% with advanced arcuate at 3.4%. CONCLUSIONS: A proposed combined visual field classification for high myopia and glaucoma demonstrates acceptable intergrader agreement. A total of 16.1% of defects in young high myopes were found to mimic classic glaucomatous defects. These subjects are being followed prospectively to assess which ones will progress to differentiate myopic from glaucomatous field defects.


Assuntos
Miopia/complicações , Refração Ocular/fisiologia , Sistema de Registros , Escotoma/classificação , Campos Visuais/fisiologia , Adolescente , Adulto , Idoso , Criança , China , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/diagnóstico , Miopia/fisiopatologia , Disco Óptico/diagnóstico por imagem , Estudos Prospectivos , Escotoma/diagnóstico , Escotoma/etiologia , Fatores de Tempo , Testes de Campo Visual , Adulto Jovem
5.
Arq. bras. oftalmol ; 79(2): 73-77, Mar.-Apr. 2016. tab
Artigo em Inglês | LILACS | ID: lil-782797

RESUMO

ABSTRACT Purpose: To compare visual acuity (VA), contrast sensitivity, stereopsis, and subjective visual performance of Acuvue® Oasys® for Presbyopia (AOP), Air Optix® Aqua Multifocal (AOMF), and Air Optix® Aqua Single Vision (AOSV) lenses in patients with presbyopia. Methods: A single-blinded crossover trial was conducted. Twenty patients with mild presbyopia (add ≤+1.25 D) and 22 with moderate/severe presbyopia (add ≥+1.50 D) who wore lenses bilaterally for 1 h, with a minimum overnight washout period between the use of each lens. Measurements included high- and low-contrast visual acuity (HCVA and LCVA, respectively) at a distance, contrast sensitivity (CS) at a distance, HCVA at intermediate (70 cm) and near (50 cm & 40 cm) distances, stereopsis, and subjective questionnaires regarding vision clarity, ghosting, overall vision satisfaction, and comfort. The test variables were compared among the lens types using repeated-measures ANOVA. Results: Distance variables (HCVA, LCVA, and CS) were significantly worse with multifocal lens than with AOSV lens (p≤0.008), except for AOMF lens in the mild presbyopia group in which no significant difference was observed (p>0.05). Multifocal lenses had significantly greater HCVA at 40 cm than AOSV lens (p≤0.026). AOMF lens had greater intermediate HCVA than AOP lens (p<0.03). AOP lens demonstrated greater improvements in stereopsis than AOMF and AOSV lens in the moderate/severe presbyopia group (p≤0.03). Few significant differences in subjective variables were observed, with no significant difference in the overall vision satisfaction observed between lens types (p>0.05). The proportions of patients willing to buy AOSV, AOMF, and AOP lenses were 20%, 40%, and 50%, respectively, in the mild presbyopia group and 14%, 32%, and 23%, respectively, in the moderate/severe presbyopia group; however, these differences were not statistically significant (p≥0.159). Conclusions: Further development of multifocal lenses is required before significant advantages of multifocal lenses over single vision lens are observed in patients with presbyopia.


RESUMO Objetivo: Comparar a acuidade visual, sensibilidade ao contraste, estereopsia e desempenho visual subjetivo de présbitas usando lentes de contato Acuvue Oasys para presbiopia (AOP), Air Optix Aqua Multifocal (AOMF) e Air Optix Aqua Single Vision (AOSV). Método: Foi realizado estudo mascarado simples, cruzado. Vinte pacientes com presbiopia baixa (adição ≤+1,25 D) e 22 com presbiopia média/alta (adição ≥+1,50 D) usaram cada lente bilateralmente durante 1 hora, com descanso mínimo de uma noite entre as diferentes lentes. As medições incluíram acuidade visual para distância em alto e baixo contraste (HCVA, LCVA), sensibilidade ao contraste para distância (CS), HCVA para distância intermediária (70 cm) e para perto (50 cm e 40 cm), estereopsia e questionários subjetivos sobre nitidez visual, fantasmas, satisfação visão geral e conforto. As variáveis foram comparadas entre os tipos de lentes, utilizando medidas repetidas ANOVA. Resultados: As variáveis para distância (HCVA, LCVA, CS) foram significativamente piores com as multifocais em relação a AOSV (p≤0,008), exceto para AOMF no grupo de baixa adição, que não foi significativamente diferente (p>0,05). As multifocais foram significativamente melhores do que a AOSV para HCVA em 40 cm (p≤0,026). AOMF superou AOP para HCVA intermediária (p<0,03). AOP superou AOMF e AOSV em relação à estereopsia no grupo de presbiopia médio/alto (p≤0,03). Houve poucas diferenças significativas nas variáveis subjetivas, mas a satisfação visual global não foi significativamente diferente entre as lentes (p>0,05). A disposição para comprar lentes AOSV, AOMF e AOP foi: 20%, 40%, 50%, respectivamente, no grupo de presbiopia baixa; 14%, 32%, 23% no grupo de presbiopia média/alto, mas essas diferenças não foram estatisticamente significativas (p≥0,159). Conclusões: Melhorias futuras parecem ser necessárias para produção de uma lente multifocal que forneça aos présbitas uma vantagem significativa sobre a lente de visão única.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Presbiopia/reabilitação , Lentes de Contato Hidrofílicas , Desenho de Equipamento , Presbiopia/classificação , Testes Visuais , Sensibilidades de Contraste/fisiologia , Acuidade Visual/fisiologia , Método Simples-Cego , Estudos Prospectivos , Inquéritos e Questionários , Satisfação do Paciente , Estudos Cross-Over , Percepção de Profundidade/fisiologia
6.
Ophthalmic Physiol Opt ; 36(2): 120-31, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26890701

RESUMO

PURPOSE: To investigate the effects of the duration of contact lens (CL) wear on the meibomian glands (MGs), eyelid and tear film. METHODS: This was a cross-sectional study of CL wearers and non-wearers (NWs) aged between 18 and 35 years. The sample comprised of: (i) Three groups of CL wearers of different duration profiles (short, moderate and long experience of CL wear); (ii) a group of previous CL wearers (PWs) who had ceased wear for at least 6 months prior to the present study; (iii) healthy non-wearers as a control group. Study procedures were conducted in the order from least invasive to most invasive as follows: symptom assessment, lipid assessment, non-invasive break-up time, tear meniscus area, tear osmolarity and evaporation, Phenol red thread, MG expressibility, ocular surface and eyelid assessments, meibography, Marx line and lid wiper assessment using lissamine green. For statistical comparison of continuous data, one-way analysis of variance was used with Bonferroni post-hoc correction, where appropriate. Kruskal-Wallis test and Pearson Chi-Square respectively were used for ordinal and categorical variables. RESULTS: A total of 100 participants (49 males and 51 females; mean age ± SD: 25.4 ± 4.1) were enrolled across the five groups, such that each was composed of 20 age/sex matched individuals. Significant differences between the study groups were found for MG expressibility (p < 0.001), number of plugged orifices (p = 0.001), number of expressed orifices (p < 0.001), MG dropout (p = 0.001), Marx line score (p < 0.001), palpebral redness (p = 0.003), and roughness (p = 0.002), non-invasive break-up time (p < 0.001), Phenol red thread (p = 0.005), and tear meniscus area (p = 0.029). For all these variables, the NW group was statistically different from all other groups. Duration of wear was not a significant factor, except for Marx line score which was different in PWs compared to those with longer experience of CL wear (p = 0.03) CONCLUSION: Alterations to MG morphology and function accompany contact lens wear. Although these changes onset during the first 2 years of wear, prolonged CL exposure beyond this point does not appear to be associated with further modification. Cessation of wear for at up to 6 months does not lead to resolution.


Assuntos
Lentes de Contato Hidrofílicas/efeitos adversos , Síndromes do Olho Seco/fisiopatologia , Glândulas Tarsais/fisiopatologia , Adulto , Estudos Transversais , Síndromes do Olho Seco/etiologia , Feminino , Humanos , Masculino , New South Wales , Concentração Osmolar , Lágrimas/metabolismo , Adulto Jovem
7.
Ophthalmology ; 123(5): 1036-42, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26875007

RESUMO

PURPOSE: Myopia is a common cause of vision loss, with uncorrected myopia the leading cause of distance vision impairment globally. Individual studies show variations in the prevalence of myopia and high myopia between regions and ethnic groups, and there continues to be uncertainty regarding increasing prevalence of myopia. DESIGN: Systematic review and meta-analysis. METHODS: We performed a systematic review and meta-analysis of the prevalence of myopia and high myopia and estimated temporal trends from 2000 to 2050 using data published since 1995. The primary data were gathered into 5-year age groups from 0 to ≥100, in urban or rural populations in each country, standardized to definitions of myopia of -0.50 diopter (D) or less and of high myopia of -5.00 D or less, projected to the year 2010, then meta-analyzed within Global Burden of Disease (GBD) regions. Any urban or rural age group that lacked data in a GBD region took data from the most similar region. The prevalence data were combined with urbanization data and population data from United Nations Population Department (UNPD) to estimate the prevalence of myopia and high myopia in each country of the world. These estimates were combined with myopia change estimates over time derived from regression analysis of published evidence to project to each decade from 2000 through 2050. RESULTS: We included data from 145 studies covering 2.1 million participants. We estimated 1406 million people with myopia (22.9% of the world population; 95% confidence interval [CI], 932-1932 million [15.2%-31.5%]) and 163 million people with high myopia (2.7% of the world population; 95% CI, 86-387 million [1.4%-6.3%]) in 2000. We predict by 2050 there will be 4758 million people with myopia (49.8% of the world population; 3620-6056 million [95% CI, 43.4%-55.7%]) and 938 million people with high myopia (9.8% of the world population; 479-2104 million [95% CI, 5.7%-19.4%]). CONCLUSIONS: Myopia and high myopia estimates from 2000 to 2050 suggest significant increases in prevalences globally, with implications for planning services, including managing and preventing myopia-related ocular complications and vision loss among almost 1 billion people with high myopia.


Assuntos
Saúde Global/tendências , Miopia Degenerativa/epidemiologia , Miopia/epidemiologia , Humanos , População Rural/estatística & dados numéricos , População Urbana/estatística & dados numéricos
8.
Obesity (Silver Spring) ; 24(3): 743-9, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26833805

RESUMO

OBJECTIVE: To explore the associations of 5-year trend and fluctuation in body mass index (BMI) with retinal vascular caliber in a middle-aged and elderly Chinese population. METHODS: Participants age ≥40 years were recruited in a prospective study. Baseline BMI data were collected in 2008, and the participants were re-examined annually until 2012. Retinal vascular caliber was measured from fundus photographs collected in 2012. BMI trend was calculated as the slope of BMI against the time of examinations. BMI fluctuation was defined as the root mean square error around the regression line of BMI over time (BMI RMSE) and the coefficient of variation of BMI (BMI CV). RESULTS: Rising BMI trend was associated with narrower retinal arteriolar and wider venular calibers in the overall subjects, especially among persons with overweight and obesity (BMI ≥ 25 kg/m(2) , P = 0.004 and 0.033, respectively). Rising BMI trend was also significantly associated with narrower retinal arteriole even in nonobese individuals with BMI < 25 kg/m(2) (P = 0.017) when eliminating the effects of hypertension and diabetes. Neither BMI RMSE nor BMI CV was statistically associated with retinal vascular caliber (all P > 0.05). CONCLUSIONS: Annual rising trending BMI was associated with retinal microvascular alteration. The results suggest that weight gain probably increases the risk of cardiovascular diseases among middle-aged and elderly people.


Assuntos
Microvasos/fisiopatologia , Obesidade/epidemiologia , Obesidade/fisiopatologia , Adulto , Idoso , Povo Asiático/estatística & dados numéricos , Índice de Massa Corporal , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/fisiopatologia , China/epidemiologia , Comorbidade , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Vasos Retinianos/fisiopatologia
9.
Optom Vis Sci ; 93(4): 435-44, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26808384

RESUMO

PURPOSE: To compare the objective and subjective visual performance of a novel contact lens which extends depth of focus by deliberate manipulation of higher-order spherical aberrations and a commercially available zonal-refractive multifocal lens. METHODS: A prospective, cross-over, randomized, single-masked, short-term clinical trial comprising 41 presbyopes (age 45 to 70 years) wearing novel Extended Depth of Focus lenses (EDOF) and ACUVUE OAYS for Presbyopia (AOP). Each design was assessed on different days with a minimum overnight wash-out. Objective measures comprised high-contrast visual acuity (HCVA, logMAR) at 6 m, 70 cm, 50 cm, and 40 cm; low-contrast visual acuity (LCVA, logMAR) and contrast sensitivity (log units) at 6 m; and stereopsis (seconds of arc) at 40 cm. HCVA at 70 cm, 50 cm, and 40 cm were measured as "comfortable acuity" rather than conventional resolution acuity. Subjective performance was assessed on a 1-10 numeric rating scale for clarity of vision and ghosting at distance, intermediate and near, overall vision satisfaction, ocular comfort, and lens purchase. Statistical analysis included repeated measures ANOVA and paired t tests. RESULTS: HCVA, clarity of vision, and ghosting with EDOF were significantly better than AOP (p < 0.01); however, differences were dependent on testing distances and add groups. Post hoc analysis showed EDOF was significantly better than AOP for HCVA at 70 cm (0.11 ± 0.11 vs. 0.21 ± 0.16, p < 0.001), 50 cm (0.26 ± 0.17 vs. 0.36 ± 0.18, p = 0.003), 40 cm (0.42 ± 0.17 vs. 0.52 ± 0.21, p = 0.001), and LCVA at 6 m (0.22 ± 0.08 vs. 0.27 ± 0.12, p = 0.024). EDOF was significantly better than AOP for clarity of vision at distance (7.7 ± 1.6 vs. 6.8 ± 2.3, p = 0.029), intermediate (8.8 ± 1.4 vs. 7.0 ± 2.2, p < 0.001), and near (7.4 ± 2.4 vs. 5.2 ± 2.7, p < 0.001), ghosting at distance (9.1 ± 1.2 vs. 8.1 ± 2.5, p = 0.005), and overall vision satisfaction (7.6 ± 1.6 vs. 6.0 ± 2.6, p < 0.001). More participants chose to purchase EDOF compared to AOP (61 vs. 39%) and significantly more chose to only-purchase EDOF compared to only-purchase AOP (27 vs. 5%, p = 0.022). CONCLUSIONS: When compared with AOP, EDOF lenses provide better intermediate and near vision performance in presbyopic participants without compromising distance vision.


Assuntos
Lentes de Contato Hidrofílicas , Percepção de Profundidade/fisiologia , Presbiopia/terapia , Idoso , Sensibilidades de Contraste/fisiologia , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Presbiopia/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Método Simples-Cego , Acuidade Visual/fisiologia
10.
Ocul Surf ; 14(1): 49-55, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26524238

RESUMO

PURPOSE: To compare the lipid composition of human meibum across three different meibum expression techniques. METHODS: Meibum was collected from five healthy non-contact lens wearers (aged 20-35 years) after cleaning the eyelid margin using three meibum expression methods: cotton buds (CB), meibomian gland evaluator (MGE) and meibomian gland forceps (MGF). Meibum was also collected using cotton buds without cleaning the eyelid margin (CBn). Lipids were analyzed by chip-based, nano-electrospray mass spectrometry (ESI-MS). Comparisons were made using linear mixed models. RESULTS: Tandem MS enabled identification and quantification of over 200 lipid species across ten lipid classes. There were significant differences between collection techniques in the relative quantities of polar lipids obtained (P<.05). The MGE method returned smaller polar lipid quantities than the CB approaches. No significant differences were found between techniques for nonpolar lipids. No significant differences were found between cleaned and non-cleaned eyelids for polar or nonpolar lipids. CONCLUSION: Meibum expression technique influences the relative amount of phospholipids in the resulting sample. The highest amounts of phospholipids were detected with the CB approaches and the lowest with the MGE technique. Cleaning the eyelid margin prior to expression was not found to affect the lipid composition of the sample. This may be a consequence of the more forceful expression resulting in cell membrane contamination or higher risk of tear lipid contamination as a result of reflex tearing.


Assuntos
Lipídeos/análise , Glândulas Tarsais/metabolismo , Lágrimas/química , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Espectrometria de Massas , Adulto Jovem
11.
Cont Lens Anterior Eye ; 39(1): 38-46, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26228543

RESUMO

PURPOSE: To assess visual performance of single vision and multifocal soft contact lenses. METHODS: At baseline, forty-four myopic participants (aged 18-35 years) were fitted bilaterally with a control lens (AirOptix Aqua). At the four follow-up visits, a total of 16 study lenses (5 single vision, 11 multifocal lenses) were fitted contralaterally. After 1h of lens wear, participants rated (scale 1-10) vision clarity (distance, intermediate and near), magnitude of ghosting at distance, comfort during head movement, and overall comfort. Distance high contrast visual acuity (HCVA), central refraction and higher order aberrations, and contact lens centration were measured. RESULTS: For single vision lenses, vision ratings were not significantly different to the control (p>0.005). The control outperformed Acuvue Oasys, Clariti Monthly and Night and Day in HCVA (mean VA: -0.10 ± 0.07 logMAR, p<0.005). Most refraction and higher order aberration measures were not different between lenses. The Night and Day lens showed greatest differences compared to the control, i.e., C[4, 0] was more positive (p<0.005) at distance (Δ=0.019 µm) and near (Δ=0.028 µm). For multifocal lenses, the majority of vision ratings (84%) were better with the control (p<0.005). HCVA was better with the control (p<0.005). Proclear Multifocal lenses showed greatest differences for M, C[3, -1] and C[4, 0] at distance and near, and were inferiorly de-centered (p<0.005). CONCLUSION: Design differences between single vision lenses had a small impact on visual performance. Lenses featuring multifocality decreased visual performance, in particular when power variations across the optic zone were large and/or the lens was significantly de-centered.


Assuntos
Lentes de Contato Hidrofílicas , Sensibilidades de Contraste/fisiologia , Miopia/fisiopatologia , Acuidade Visual/fisiologia , Adolescente , Adulto , Desenho de Equipamento , Feminino , Humanos , Masculino , Miopia/terapia , Presbiopia , Estudos Prospectivos , Testes Visuais , Adulto Jovem
13.
Ophthalmic Epidemiol ; 22(6): 409-16, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26653263

RESUMO

PURPOSE: To assess clinical competency of 1-year trained vision technicians (VTs) in detecting and referring causes of visual impairment in India. METHODS: Eye examination results and management plans for 328 patients examined by 24 VTs in 24 vision centers of LV Prasad Eye Institute in Andhra Pradesh were compared with those of a standard optometrist who examined the same patients. Eye examinations included retinoscopy and subjective refraction, slit lamp examination, applanation tonometry and undilated direct ophthalmoscopy. Data were analyzed for level of concordance in retinoscopy, spectacle prescription, disease detection and referral. RESULTS: VTs demonstrated moderate to good levels of agreement in refraction, disease detection and referral. Sensitivity and specificity for ocular pathology identification were 77.4% (95% confidence interval, CI, 69.4-84.2%) and 86.6% (95% CI 81.1-91.1%), respectively. The highest sensitivity was demonstrated in detecting significant cataract (91.5%) and refractive error (83.0%). VT spectacle prescriptions were accurate 76% of the time for mean spherical equivalent and 65% of the time for astigmatism. VT sensitivity in detecting posterior segment abnormalities was low (18.5%) resulting in failure to detect retinal conditions such as diabetic retinopathy and maculopathy. Despite lack of recognition of the specific pathology, referral decisions were correct in 78.4% of cases. CONCLUSION: VTs in India competently detect and manage or refer the two most common causes of visual impairment; uncorrected refractive error and cataract. Over two-thirds of patients received accurate and appropriate services from VTs, suggesting that they are a useful and competent cadre for rural and remote eye care.


Assuntos
Competência Clínica/normas , Avaliação Educacional , Assistentes de Oftalmologia/educação , Assistentes de Oftalmologia/normas , Testes Visuais/normas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Estudos Transversais , Óculos/normas , Reações Falso-Positivas , Feminino , Humanos , Índia , Masculino , Pessoa de Meia-Idade , Oftalmoscopia/normas , Valor Preditivo dos Testes , Prescrições/normas , Refração Ocular , Reprodutibilidade dos Testes , Retinoscopia/normas , Serviços de Saúde Rural , Sensibilidade e Especificidade , Lâmpada de Fenda/normas , Tonometria Ocular/normas , Pessoas com Deficiência Visual/reabilitação
15.
Invest Ophthalmol Vis Sci ; 56(11): 6490-500, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26447984

RESUMO

PURPOSE: Differences in the spectral composition of lighting between indoor and outdoor scenes may contribute to the higher prevalence of myopia in children who spend low amounts of time outdoors. Our goal was to determine whether environments dominated by long-wavelength light promote the development of myopia. METHODS: Beginning at 25 ± 2 days of age, infant monkeys were reared with long-wavelength-pass (red) filters in front of one (MRL, n = 6) or both eyes (BRL, n = 7). The filters were worn continuously until 146 ± 7 days of age. Refractive development, corneal power, and vitreous chamber depth were assessed by retinoscopy, keratometry, and ultrasonography, respectively. Control data were obtained from 6 monkeys reared with binocular neutral density (ND) filters and 33 normal monkeys reared with unrestricted vision under typical indoor lighting. RESULTS: At the end of the filter-rearing period, the median refractive error for the BRL monkeys (+4.25 diopters [D]) was significantly more hyperopic than that for the ND (+2.22 D; P = 0.003) and normal monkeys (+2.38 D; P = 0.0001). Similarly, the MRL monkeys exhibited hyperopic anisometropias that were larger than those in normal monkeys (+1.70 ± 1.55 vs. -0.013 ± 0.33 D, P < 0.0001). The relative hyperopia in the treated eyes was associated with shorter vitreous chambers. Following filter removal, the filter-reared monkeys recovered from the induced hyperopic errors. CONCLUSIONS: The observed hyperopic shifts indicate that emmetropization does not necessarily target the focal plane that maximizes luminance contrast and that reducing potential chromatic cues can interfere with emmetropization. There was no evidence that environments dominated by long wavelengths necessarily promote myopia development.


Assuntos
Córnea/efeitos da radiação , Iluminação , Refração Ocular/efeitos da radiação , Erros de Refração/fisiopatologia , Animais , Animais Recém-Nascidos , Modelos Animais de Doenças , Macaca mulatta , Estimulação Luminosa , Erros de Refração/diagnóstico
16.
Ophthalmology ; 122(8): 1706-10, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26190438

RESUMO

PURPOSE: The onset of presbyopia in middle adulthood results in potential losses in productivity among otherwise healthy adults if uncorrected or undercorrected. The economic burden could be significant in lower-income countries, where up to 94% of cases may be uncorrected or undercorrected. This study estimates the global burden of potential productivity lost because of uncorrected functional presbyopia. DESIGN: Population data from the US Census Bureau were combined with the estimated presbyopia prevalence, age of onset, employment rate, gross domestic product (GDP) per capita in current US dollars, and near vision impairment disability weights from the Global Burden of Disease 2010 study to estimate the global loss of productivity from uncorrected and undercorrected presbyopia in each country in 2011. To allow comparison with earlier work, we also calculated the loss with the conservative assumption that the contribution to productivity extends only up to 50 years of age. PARTICIPANTS: The economic modeling did not require the use of subjects. METHODS: We estimated the number of cases of uncorrected or undercorrected presbyopia in each country among the working-age population. The number of working-age cases was multiplied by the labor force participation rate, the employment rate, a disability weight, and the GDP per capita to estimate the potential loss of GDP due to presbyopia. MAIN OUTCOME MEASURES: The outcome being measured is the lost productivity in 2011 US dollars resulting from uncorrected or undercorrected presbyopia. RESULTS: There were an estimated 1.272 billion cases of presbyopia worldwide in 2011. A total of 244 million cases, uncorrected or undercorrected among people aged <50 years, were associated with a potential productivity loss of US $11.023 billion (0.016% of global GDP). If all those people aged <65 years are assumed to be productive, the potential productivity loss would be US $25.367 billion or 0.037% of global GDP. Correcting presbyopia to the level achieved in Europe would reduce the burden to US $1.390 billion (0.002% of global GDP). CONCLUSIONS: Even with conservative assumptions regarding the productive population, presbyopia is a significant burden on productivity, and correction would have a significant impact on productivity in lower-income countries.


Assuntos
Efeitos Psicossociais da Doença , Eficiência , Saúde Global , Presbiopia/economia , Desemprego/estatística & dados numéricos , Transtornos da Visão/economia , Pessoas com Deficiência Visual/estatística & dados numéricos , Adulto , Idade de Início , Idoso , Feminino , Produto Interno Bruto , Humanos , Masculino , Pessoa de Meia-Idade , Presbiopia/terapia , Prevalência , Transtornos da Visão/terapia , Organização Mundial da Saúde
17.
Optom Vis Sci ; 92(2): 157-66, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25951477

RESUMO

PURPOSE: The purpose of the study was to assess what effect daily cleaning of contact lenses with a multipurpose disinfection solution (MPDS), during 30 nights extended wear, would have on contact lens-related adverse events. METHODS: This was a prospective, open-label, randomized, controlled, parallel-group, 3-month clinical study in which 193 participants were dispensed with lotrafilcon A silicone hydrogel lenses for a 30-day extended-wear schedule and with lenses replaced monthly. Participants were randomized to a control or test group. Test subjects were required to remove lenses daily after waking, clean them with the MPDS, and reinsert the lenses. Control subjects wore lenses without removal for 30 days extended wear. Handling-related lens contamination was assessed at the baseline visit. RESULTS: There was no significant difference between the test and control groups for the incidence of significant corneal infiltrative events (1.3 vs. 4.9%, p = 0.368), total corneal infiltrative events (2.6 vs. 4.9%, p = 0.682), or mechanical events (1.3 vs. 2.5%, p = 1.00). The test group had greater corneal staining (p < 0.047) and fewer mucin balls (p = 0.033). Handling-related lens contamination (unworn lenses) resulted in isolation of Gram-positive bacteria from 92.5% of test lenses compared with 87.5% of control lenses (p = 0.712). Gram-negative bacteria were isolated from 5% of test subjects compared with 2.5% of control subjects (p = 1.00). Fungus was isolated from 2.5% of subjects in both the test and control groups (p = 1.00). CONCLUSIONS: The intervention of daily morning cleaning of the lens surface with an MPDS during extended wear did not significantly influence the incidence of adverse events.


Assuntos
Soluções para Lentes de Contato/uso terapêutico , Lentes de Contato de Uso Prolongado/efeitos adversos , Lentes de Contato de Uso Prolongado/microbiologia , Infecções Oculares Bacterianas/etiologia , Fungos/isolamento & purificação , Bactérias Gram-Negativas/isolamento & purificação , Bactérias Gram-Positivas/isolamento & purificação , Adolescente , Contagem de Colônia Microbiana , Feminino , Desinfecção das Mãos , Humanos , Hidrogéis , Incidência , Masculino , Estudos Prospectivos , Silicones
18.
Optom Vis Sci ; 92(7): 741-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26002010

RESUMO

This article, an edited version of the 2014 Charles F. Prentice Medal presentation, recounts my 50-year journey in research, from graduation in 1965 to PhD to 2015. The most important lessons I have learned are that great people, "Giants" as I call them, are generous of spirit, creative, insightful, sharing, and caring, and second, that collaboration is really the only way to do what I want to get done. I have been very fortunate to have worked with many outstanding people. As someone said to me at the Prentice Medal presentation, "I don't like you very much but the people you work with are wonderful."My journey started with a PhD investigation into seeing if orthokeratology could control myopia at the City University London in 1966. It then moved to Australia where all aspects of contact lenses were researched to try to make contact lenses safer and more effective by understanding the cornea and anterior eye systems. That journey has now turned to making contact lenses the best they can be to slow the progress of myopia. An extremely high proportion of people who are involved with global eye care initiatives and ambitious projects to develop treatments and interventions for the major vision problems impacting the world are a joy to work with. Evidence-based systems for delivering vision to the more than 600 million people globally that are blind or vision impaired because of uncorrected refractive error have involved amazing people and collaborations. This article pays tribute to the generosity and humanity of my family and the Giants in and outside the field, and many more not so well known, and the people I work with, who have punctuated and greatly enriched this journey and made many of the scientific advances documented here possible.


Assuntos
Distinções e Prêmios , Optometria/história , Austrália , Lentes de Contato/história , Comportamento Cooperativo , História do Século XX , História do Século XXI , Humanos , Miopia/história , Miopia/terapia , Procedimentos Ortoceratológicos/história , Sociedades Médicas
20.
Invest Ophthalmol Vis Sci ; 56(2): 842-8, 2015 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-25613941

RESUMO

PURPOSE: Structural changes of retinal vasculature, such as altered retinal vascular calibers, are considered as early signs of systemic vascular damage. We examined the associations of 5-year mean level, longitudinal trend, and fluctuation in fasting plasma glucose (FPG) with retinal vascular caliber in people without established diabetes. METHODS: A prospective study was conducted in a cohort of Chinese people age ≥40 years in Guangzhou, southern China. The FPG was measured at baseline in 2008 and annually until 2012. In 2012, retinal vascular caliber was assessed using standard fundus photographs and validated software. A total of 3645 baseline nondiabetic participants with baseline and follow-up data on FPG for 3 or more visits was included for statistical analysis. The associations of retinal vascular caliber with 5-year mean FPG level, longitudinal FPG trend (slope of linear regression-FPG), and fluctuation (standard deviation and root mean square error of FPG) were analyzed using multivariable linear regression analyses. RESULTS: Multivariate regression models adjusted for baseline FPG and other potential confounders showed that a 10% annual increase in FPG was associated independently with a 2.65-µm narrowing in retinal arterioles (P = 0.008) and a 3.47-µm widening in venules (P = 0. 0.004). Associations with mean FPG level and fluctuation were not statistically significant. CONCLUSIONS: Annual rising trend in FPG, but not its mean level or fluctuation, is associated with altered retinal vasculature in nondiabetic people.


Assuntos
Glicemia/metabolismo , Retinopatia Diabética/sangue , Jejum/sangue , Vasos Retinianos/patologia , Adulto , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Microvasos/patologia , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA