1.
Nat Commun ; 11(1): 4191, 2020 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-32826892

RESUMO

The nascent field of bioelectronic medicine seeks to decode and modulate peripheral nervous system signals to obtain therapeutic control of targeted end organs and effectors. Current approaches rely heavily on electrode-based devices, but size scalability, material and microfabrication challenges, limited surgical accessibility, and the biomechanically dynamic implantation environment are significant impediments to developing and deploying peripheral interfacing technologies. Here, we present a microscale implantable device - the nanoclip - for chronic interfacing with fine peripheral nerves in small animal models that begins to meet these constraints. We demonstrate the capability to make stable, high signal-to-noise ratio recordings of behaviorally-linked nerve activity over multi-week timescales. In addition, we show that multi-channel, current-steering-based stimulation within the confines of the small device can achieve multi-dimensional control of a small nerve. These results highlight the potential of new microscale design and fabrication techniques for realizing viable devices for long-term peripheral interfacing.


Assuntos
Microeletrodos , Nervos Periféricos/fisiologia , Impressão Tridimensional , Animais , Engenharia Biomédica , Eletrodos Implantados , Potenciais Evocados , Tentilhões/fisiologia , Masculino , Microtecnologia , Modelos Animais , Nervos Periféricos/cirurgia , Razão Sinal-Ruído
2.
Diabetologia ; 61(3): 700-710, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29332196

RESUMO

AIMS/HYPOTHESIS: A new class of treatments termed bioelectronic medicines are now emerging that aim to target individual nerve fibres or specific brain circuits in pathological conditions to repair lost function and reinstate a healthy balance. Carotid sinus nerve (CSN) denervation has been shown to improve glucose homeostasis in insulin-resistant and glucose-intolerant rats; however, these positive effects from surgery appear to diminish over time and are heavily caveated by the severe adverse effects associated with permanent loss of chemosensory function. Herein we characterise the ability of a novel bioelectronic application, classified as kilohertz frequency alternating current (KHFAC) modulation, to suppress neural signals within the CSN of rodents. METHODS: Rats were fed either a chow or high-fat/high-sucrose (HFHSu) diet (60% lipid-rich diet plus 35% sucrose drinking water) over 14 weeks. Neural interfaces were bilaterally implanted in the CSNs and attached to an external pulse generator. The rats were then randomised to KHFAC or sham modulation groups. KHFAC modulation variables were defined acutely by respiratory and cardiac responses to hypoxia (10% O2 + 90% N2). Insulin sensitivity was evaluated periodically through an ITT and glucose tolerance by an OGTT. RESULTS: KHFAC modulation of the CSN, applied over 9 weeks, restored insulin sensitivity (constant of the insulin tolerance test [KITT] HFHSu sham, 2.56 ± 0.41% glucose/min; KITT HFHSu KHFAC, 5.01 ± 0.52% glucose/min) and glucose tolerance (AUC HFHSu sham, 1278 ± 20.36 mmol/l × min; AUC HFHSu KHFAC, 1054.15 ± 62.64 mmol/l × min) in rat models of type 2 diabetes. Upon cessation of KHFAC, insulin resistance and glucose intolerance returned to normal values within 5 weeks. CONCLUSIONS/INTERPRETATION: KHFAC modulation of the CSN improves metabolic control in rat models of type 2 diabetes. These positive outcomes have significant translational potential as a novel therapeutic modality for the purpose of treating metabolic diseases in humans.


Assuntos
Seio Carotídeo/inervação , Diabetes Mellitus Tipo 2/sangue , Animais , Glicemia/metabolismo , Peptídeo C/sangue , Corticosterona/sangue , Diabetes Mellitus Tipo 2/fisiopatologia , Eletromiografia , Insulina/sangue , Resistência à Insulina/fisiologia , Masculino , Óxido Nítrico/sangue , Pletismografia , Ratos
3.
J Neural Eng ; 15(1): 016010, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28905812

RESUMO

OBJECTIVE: Most preparations for making neural recordings degrade over time and eventually fail due to insertion trauma and reactive tissue response. The magnitudes of these responses are thought to be related to the electrode size (specifically, the cross-sectional area), the relative stiffness of the electrode, and the degree of tissue tolerance for the material. Flexible carbon fiber ultra-microelectrodes have a much smaller cross-section than traditional electrodes and low tissue reactivity, and thus may enable improved longevity of neural recordings in the central and peripheral nervous systems. Only two carbon fiber array designs have been described previously, each with limited channel densities due to limitations of the fabrication processes or interconnect strategies. Here, we describe a method for assembling carbon fiber electrodes on a flexible polyimide substrate that is expected to facilitate the construction of high-density recording and stimulating arrays. APPROACH: Individual carbon fibers were aligned using an alignment tool that was 3D-printed with sub-micron resolution using direct laser writing. Indium deposition on the carbon fibers, followed by low-temperature microsoldering, provided a robust and reliable method of electrical connection to the polyimide interconnect. MAIN RESULTS: Spontaneous multiunit activity and stimulation-evoked compound responses with SNR >10 and >120, respectively, were recorded from a small (125 µm) peripheral nerve. We also improved the typically poor charge injection capacity of small diameter carbon fibers by electrodepositing 100 nm-thick iridium oxide films, making the carbon fiber arrays usable for electrical stimulation as well as recording. SIGNIFICANCE: Our innovations in fabrication technique pave the way for further miniaturization of carbon fiber ultra-microelectrode arrays. We believe these advances to be key steps to enable a shift from labor intensive, manual assembly to a more automated manufacturing process.


Assuntos
Fibra de Carbono , Eletrodos Implantados , Nervo Hipoglosso/fisiologia , Resinas Sintéticas , Animais , Fibra de Carbono/química , Feminino , Tentilhões , Masculino , Microeletrodos , Resinas Sintéticas/química
4.
J Neural Eng ; 14(3): 036006, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28323640

RESUMO

OBJECTIVE: The vision of bioelectronic medicine is to treat disease by modulating the signaling of visceral nerves near various end organs. In small animal models, the nerves of interest can have small diameters and limited surgical access. New high-resolution methods for building nerve interfaces are desirable. In this study, we present a novel nerve interface and demonstrate its use for stimulation and recording in small nerves. APPROACH: We design and fabricate micro-scale electrode-laden nanoclips capable of interfacing with nerves as small as 50 µm in diameter. The nanoclips are fabricated using a direct laser writing technique with a resolution of 200 nm. The resolution of the printing process allows for incorporation of a number of innovations such as trapdoors to secure the device to the nerve, and quick-release mounts that facilitate keyhole surgery, obviating the need for forceps. The nanoclip can be built around various electrode materials; here we use carbon nanotube fibers for minimally invasive tethering. MAIN RESULTS: We present data from stimulation-evoked responses of the tracheal syringeal (hypoglossal) nerve of the zebra finch, as well as quantification of nerve functionality at various time points post implant, demonstrating that the nanoclip is compatible with healthy nerve activity over sub-chronic timescales. SIGNIFICANCE: Our nerve interface addresses key challenges in interfacing with small nerves in the peripheral nervous system. Its small size, ability to remain on the nerve over sub-chronic timescales, and ease of implantation, make it a promising tool for future use in the treatment of disease.


Assuntos
Potenciais de Ação/fisiologia , Eletrodos Implantados , Neuroestimuladores Implantáveis , Nanotecnologia/instrumentação , Nervos Periféricos/fisiologia , Impressão Tridimensional , Animais , Remoção de Dispositivo/instrumentação , Remoção de Dispositivo/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Traqueia/inervação , Traqueia/fisiologia , Estimulação Elétrica Nervosa Transcutânea , Peixe-Zebra
5.
IEEE Trans Biomed Circuits Syst ; 10(4): 902-11, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26978832

RESUMO

Neural pathways can be artificially activated through the use of electrical stimulation. For individuals with a spinal cord injury, intraspinal microstimulation, using electrical currents on the order of 125 µ A, can produce muscle contractions and joint torques in the lower extremities suitable for restoring walking. The work presented here demonstrates an integrated circuit implementing a state-based control strategy where sensory feedback and intrinsic feed forward control shape the stimulation waveforms produced on-chip. Fabricated in a 0.5 µ m process, the device was successfully used in vivo to produce walking movements in a model of spinal cord injury. This work represents progress towards an implantable solution to be used for restoring walking in individuals with spinal cord injuries.


Assuntos
Locomoção/fisiologia , Animais , Gatos , Estimulação Elétrica , Eletrodos Implantados , Desenho de Equipamento , Modelos Biológicos , Traumatismos da Medula Espinal/fisiopatologia , Transistores Eletrônicos
6.
Artigo em Inglês | MEDLINE | ID: mdl-22255658

RESUMO

The overall objective of this project is to develop a feedback-driven intraspinal microstimulation (ISMS) system. We hypothesize that ISMS will enhance the functionality of stepping by reducing muscle fatigue and producing synergistic movements by activating neural networks in the spinal cord. In the present pilot study, the controller was tested with ISMS and external sensors (force plates, gyroscopes, and accelerometers). Cats were partially supported in a sling and bi-laterally stepped overground on a 4-m instrumented walkway. The walkway had variable friction. Limb angle was controlled to within 10° even in the presence of variable friction. Peak ground reaction forces in each limb were approximately 12% of body weight (12.5% was full load bearing in this experimental setup); rarely, the total supportive force briefly decreased to as low as 4.1%. Magnetic resonance images were acquired of the excised spinal cord and the implanted array. The majority of electrodes (75%) were implanted successfully into their target regions. This represents the first successful application of ISMS for overground walking.


Assuntos
Terapia por Estimulação Elétrica/métodos , Transtornos Neurológicos da Marcha/fisiopatologia , Transtornos Neurológicos da Marcha/reabilitação , Marcha , Traumatismos da Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/reabilitação , Medula Espinal/fisiopatologia , Animais , Biorretroalimentação Psicológica/métodos , Gatos , Feminino , Transtornos Neurológicos da Marcha/etiologia , Recuperação de Função Fisiológica , Traumatismos da Medula Espinal/complicações , Resultado do Tratamento , Caminhada