Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
1.
AIDS ; 38(8): 1120-1130, 2024 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-38224350

RESUMO

OBJECTIVE: The immunogenic nature of coronavirus disease 2019 (COVID-19) mRNA vaccines led to some initial concern that these could stimulate the HIV reservoir. We analyzed changes in plasma HIV loads (pVL) and reservoir size following COVID-19 mRNA vaccination in 62 people with HIV (PWH) receiving antiretroviral therapy (ART), and analyzed province-wide trends in pVL before and after the mass vaccination campaign. DESIGN: Longitudinal observational cohort and province-wide analysis. METHODS: Sixty-two participants were sampled prevaccination, and one month after their first and second COVID-19 immunizations. Vaccine-induced anti-SARS-CoV-2-Spike antibodies in serum were measured using the Roche Elecsys Anti-S assay. HIV reservoirs were quantified using the intact proviral DNA assay; pVL were measured using the cobas 6800 (lower limit of quantification: 20 copies/ml). The province-wide analysis included all 290 401 pVL performed in British Columbia, Canada between 2012 and 2022. RESULTS: Prevaccination, the median intact reservoir size was 77 [interquartile range (IQR): 20-204] HIV copies/million CD4 + T-cells, compared to 74 (IQR: 27-212) and 65 (IQR: 22-174) postfirst and -second dose, respectively (all comparisons P > 0.07). Prevaccination, 82% of participants had pVL <20 copies/ml (max: 110 copies/ml), compared to 79% postfirst dose (max: 183 copies/ml) and 85% postsecond dose (max: 79 copies/ml) ( P  > 0.4). There was no evidence that the magnitude of the vaccine-elicited anti-SARS-CoV-2-Spike immune response influenced pVL nor changes in reservoir size ( P  > 0.6). We found no evidence linking the COVID-19 mass vaccination campaign to population-level increases in detectable pVL frequency among all PWH in the province, nor among those who maintained pVL suppression on ART. CONCLUSION: We found no evidence that COVID-19 mRNA vaccines induced changes in HIV reservoir size nor plasma viremia.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Infecções por HIV , SARS-CoV-2 , Carga Viral , Viremia , Humanos , Infecções por HIV/tratamento farmacológico , Infecções por HIV/prevenção & controle , Masculino , Feminino , Pessoa de Meia-Idade , Vacinas contra COVID-19/imunologia , Vacinas contra COVID-19/administração & dosagem , COVID-19/prevenção & controle , Adulto , SARS-CoV-2/imunologia , Estudos Longitudinais , Anticorpos Antivirais/sangue , Colúmbia Britânica , Vacinação , Reservatórios de Doenças/virologia
2.
Am Heart J ; 268: 29-36, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37992794

RESUMO

BACKGROUND: The prognostic association between dysnatremia and outcomes in out-of-hospital cardiac arrest (OHCA) is not well understood. Given hypernatremia is associated with poor outcomes in critical illness and hyponatremia may exacerbate cerebral edema, we hypothesized that dysnatremia on OHCA hospital admission would be associated with worse neurological outcomes. METHODS: We studied adults (≥19 years) with non-traumatic OHCA between 2009 and 2016 who were enrolled in the British Columbia Cardiac Arrest Registry and survived to hospital admission at 2 quaternary urban hospitals. We stratified cases by admission serum sodium into hyponatremic (<135 mmol/L), normonatremic (135-145 mmol/L), and hypernatremic (>145 mmol/L) groups. We used logistic regression models, adjusted for age, sex, shockable rhythm, admission serum lactate, and witnessed arrest, to estimate the association between admission sodium and favorable neurological outcome (cerebral performance category 1-2 or modified Rankin scale 0-3). RESULTS: Of 414 included patients, 63 were hyponatremic, 330 normonatremic, and 21 hypernatremic. In each respective group, 21 (33.3%), 159 (48.2%), and 3 (14.3%) experienced good neurological outcomes. In univariable models, hyponatremia (OR 0.53, 95% CI 0.30-0.93) and hypernatremia (OR 0.19, 95% CI 0.05-0.65) were associated with lower odds of good neurological outcomes compared to the normonatremia group. After adjustment, only hypernatremia was associated with lower odds of good neurological outcomes (OR 0.22, 95% CI 0.05-0.98). CONCLUSIONS: Hypernatremia at admission was independently associated with decreased probability of good neurological outcomes at discharge post-OHCA. Future studies should focus on elucidating the pathophysiology of dysnatremia following OHCA.


Assuntos
Reanimação Cardiopulmonar , Hipernatremia , Hiponatremia , Parada Cardíaca Extra-Hospitalar , Adulto , Humanos , Hipernatremia/etiologia , Hipernatremia/complicações , Hiponatremia/etiologia , Hiponatremia/complicações , Parada Cardíaca Extra-Hospitalar/etiologia , Parada Cardíaca Extra-Hospitalar/terapia , Sódio , Prognóstico
3.
Pathog Immun ; 8(1): 117-135, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38035132

RESUMO

Introduction: While older adults generally mount weaker antibody responses to a primary COVID-19 vaccine series, T-cell responses remain less well characterized in this population. We compared SARS-CoV-2 spike-specific T-cell responses after 2- and 3-dose COVID-19 mRNA vaccination and subsequent breakthrough infection in older and younger adults. Methods: We quantified CD4+ and CD8+ T-cells reactive to overlapping peptides spanning the ancestral SARS-CoV-2 spike protein in 40 older adults (median age 79) and 50 younger health care workers (median age 39), all COVID-19 naive, using an activation-induced marker assay. T-cell responses were further assessed in 24 participants, including 8 older adults, who subsequently experienced their first SARS-CoV-2 breakthrough infection. Results: A third COVID-19 mRNA vaccine dose significantly boosted spike-specific CD4+ and CD8+ T-cell frequencies to above 2-dose levels in older and younger adults. T-cell frequencies did not significantly differ between older and younger adults after either dose. Multivariable analyses adjusting for sociodemographic, health, and vaccine-related variables confirmed that older age was not associated with impaired cellular responses. Instead, the strongest predictors of CD4+ and CD8+ T-cell frequencies post-third-dose were their corresponding post-second-dose frequencies. Breakthrough infection significantly increased both CD4+ and CD8+ T-cell frequencies, to comparable levels in older and younger adults. Exploratory analyses revealed an association between HLA-A*02:03 and higher post-vaccination CD8+ T-cell frequencies, which may be attributable to numerous strong-binding HLA-A*02:03-specific CD8+ T-cell epitopes in the spike protein. Conclusion: Older adults mount robust T-cell responses to 2- and 3-dose COVID-19 mRNA vaccination, which are further boosted following breakthrough infection.

4.
medRxiv ; 2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37873490

RESUMO

Objective: The immunogenic nature of COVID-19 mRNA vaccines led to some initial concern that these could stimulate the HIV reservoir. We analyzed changes in plasma HIV loads (pVL) and reservoir size following COVID-19 mRNA vaccination in 62 people with HIV (PWH) receiving antiretroviral therapy (ART), and analyzed province-wide trends in pVL before and after the mass vaccination campaign. Design: Longitudinal observational cohort and province-wide analysis. Methods: 62 participants were sampled pre-vaccination, and one month after their first and second COVID-19 immunizations. Vaccine-induced anti-SARS-CoV-2-Spike antibodies in serum were measured using the Roche Elecsys Anti-S assay. HIV reservoirs were quantified using the Intact Proviral DNA Assay; pVL were measured using the cobas 6800 (LLOQ:20 copies/mL). The province-wide analysis included all 290,401 pVL performed in British Columbia, Canada between 2012-2022. Results: Pre-vaccination, the median intact reservoir size was 77 (IQR:20-204) HIV copies/million CD4+ T-cells, compared to 74 (IQR:27-212) and 65 (IQR:22-174) post-first and -second dose, respectively (all comparisons p>0.07). Pre-vaccination, 82% of participants had pVL<20 copies/mL (max:110 copies/mL), compared to 79% post-first dose (max:183 copies/mL) and 85% post-second dose (max:79 copies/mL) (p>0.4). The magnitude of the vaccine-elicited anti-SARS-CoV-2-Spike antibody response did not correlate with changes in reservoir size nor detectable pVL frequency (p>0.6). We found no evidence linking the COVID-19 mass vaccination campaign to population-level increases in detectable pVL frequency among all PWH in the province, nor among those who maintained pVL suppression on ART. Conclusion: We found no evidence that COVID-19 mRNA vaccines induced changes in HIV reservoir size nor plasma viremia.

5.
Clin Biochem ; 121-122: 110680, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37884086

RESUMO

INTRODUCTION: In this study, we aimed to create reference intervals (RI) using a large Canadian population-based cohort, for plasma protein biomarkers with potential utility to screen, diagnosis, prognosticate and manage a variety of neurological diseases and disorders. RIs were generated for: the ratio of amyloid beta 42 over 40 (Aß42/40), phosphorylated tau-181 (p-tau-181), neurofilament light (NfL), and glial fibrillary acidic protein (GFAP). METHODS: 900 plasma specimens from male and female participants aged 3-79 years old were obtained from the Statistics Canada Biobank, which holds specimens from the Canadian Health Measures Survey. Analysis of Aß42/40, p-tau-181, NfL and GFAP was performed on the Quanterix Simoa HD-X analyzer using the Neurology 4-plex E and p-tau-181 assays. Discrete RIs were produced according to Clinical Laboratory Standards Institute guidelines (EP28-A3c). Continuous RIs were created using quantile regression. RESULTS: For discrete RIs, significant age partitions were determined for each biomarker. No significant sex partitions were found. The following ranges and age partitions were determined: Aß42/40: 3-<55y = 0.053-0.098, 55-<80y = 0.040-0.090; p-tau-181: 3-<12y = 1.4-5.6 pg/ml, 12-<60y = 0.8-3.1 pg/ml, 60-<80y = 0.9-4.0 pg/ml; NfL: 3-<40y = 2.6-11.3 pg/ml, 40-<60y = 4.6-17.7 pg/ml, 60-<80y = 8.1-47.1 pg/ml; GFAP; 3-<10y = 47.0-226 pg/ml, 10-<60y = 21.2-91.9 pg/ml, 60-<80y = 40.7-228 pg/ml. Continuous RIs produced smooth centile curves across the age range, from which point estimates for each year of age were calculated. CONCLUSIONS: Discrete and continuous RIs for neurological plasma biomarkers will help refine normative cut-offs across the lifespan and improve the precision of interpretating biomarker levels. Continuous RIs are recommended for use in age groups, such as pediatrics and older adults, that experience rapid concentration changes by age.


Assuntos
Doença de Alzheimer , Peptídeos beta-Amiloides , Humanos , Masculino , Criança , Feminino , Idoso , Pré-Escolar , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Canadá , Proteínas tau , Biomarcadores
6.
J Affect Disord ; 339: 471-477, 2023 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-37442446

RESUMO

OBJECTIVE: This study aims to estimate the prevalence of and determine physician approaches to the screening and management of lithium-associated thyroid and parathyroid disorders in British Columbia, Canada. METHODS: Serum lithium and thyroid/parathyroid laboratory data were collected retrospectively for patients with lithium levels measured at seven BC hospitals between 2012 and 2021. A mail-out survey about screening and management of thyroid/parathyroid disorders in patients on lithium was sent to the ordering physicians of patients with abnormal results. Three months after, a follow-up questionnaire was sent to respondents, and the original survey was re-sent to non-responders. RESULTS: Of 4917 patients, 1.9 % had PTH (mean 22.33 ± 23.00 pmol/L) and 77.1 % had TSH (mean 3.61 ± 6.69 pmol/L) measured. Of 222 hypercalcemic patients (defined as any serum calcium or ionized calcium above the laboratory reference), 17.6 % had a PTH level measured. From 294 surveys sent to 214 physicians, the overall response rate was 31.6 % (n = 93) with twelve fully completed surveys. All twelve respondents monitored TSH levels every 6-12 months, and eight physicians monitored PTH and/or calcium at variable intervals. Two physicians routinely ordered both thyroid and parathyroid screening laboratory tests. Of the 80 non-respondents, limited patient contact was the most common reason for opting out (n = 27). CONCLUSIONS: Our results suggest biochemical screening for lithium-associated parathyroid disorders is less common than for thyroid disorders. There is insufficient data to determine the true prevalence of lithium-associated thyroid and parathyroid disorders. This highlights the need for updated clinical guidelines for management of lithium-associated thyroid and parathyroid disorders.

7.
Clin Biochem ; 116: 100-104, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37084998

RESUMO

OBJECTIVES: Bone turnover markers (BTM) are measures for understanding the effect of anti-resorptives upon osteoclast activity. Post-hoc trial data suggests reduction in BTM of 40% may represent a target for defining appropriate response to therapy. We modeled clinical application of this target threshold in an individual patient setting where assay measurement uncertainty and biological variation are included. DESIGN: Using serum C-telo-peptide (ß-CTX), we constructed hypothetical scenarios of ß-CTX measurement pre and post bisphosphonate therapy. Using typical ß-CTX assay characteristics (analytical coefficient of variation, CV 5.0%) and published intra-individual ß-CTX data for post-menopausal women (CV 18.0%), we calculated the post-therapy ß-CTX that must be seen on single repeat measure for 95% confidence that the observed result was ≥40% below baseline. Sensitivity analyses considered greater and lesser variations in the combined sources of variation. RESULTS: The one-tailed 95% reference change value for any detectable therapeutic decrease in ß-CTX was 22%. However, to have 95% confidence of having achieved a reduction ≥40%, an observed ß-CTX decrease of ≥56% is required. Larger decreases are needed for scenarios of greater analytical or intra-individual variation. CONCLUSIONS: Although population data suggest a ß-CTX decrease of 40% is commensurate with adequate therapeutic response to anti-resorptives, application to an individual patient where measurement and natural variation are present is problematic. ß-CTX decreases much >40% are required to be confident of having achieved the optimal treatment response. It is uncertain whether this is a legitimate change to be expected in all individual patients and therefore clinical application of this threshold is uncertain.


Assuntos
Densidade Óssea , Peptídeos , Humanos , Feminino , Densidade Óssea/fisiologia , Incerteza , Peptídeos/uso terapêutico , Difosfonatos/farmacologia , Difosfonatos/uso terapêutico , Remodelação Óssea , Biomarcadores , Colágeno Tipo I/farmacologia
8.
Open Forum Infect Dis ; 10(3): ofad073, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36910697

RESUMO

Background: Longer-term immune response data after 3 doses of coronavirus disease 2019 (COVID-19) mRNA vaccine remain limited, particularly among older adults and after Omicron breakthrough infection. Methods: We quantified wild-type- and Omicron-specific serum immunoglobulin (Ig)G levels, angiotensin-converting enzyme 2 displacement activities, and live virus neutralization up to 6 months after third dose in 116 adults aged 24-98 years who remained COVID-19 naive or experienced their first severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection during this time. Results: Among the 78 participants who remained COVID-19 naive throughout follow up, wild-type- and Omicron-BA.1-specific IgG concentrations were comparable between younger and older adults, although BA.1-specific responses were consistently significantly lower than wild-type-specific responses in both groups. Wild-type- and BA.1-specific IgG concentrations declined at similar rates in COVID-19-naive younger and older adults, with median half-lives ranging from 69 to 78 days. Antiviral antibody functions declined substantially over time in COVID-19-naive individuals, particularly in older adults: by 6 months, BA.1-specific neutralization was undetectable in 96% of older adults, versus 56% of younger adults. Severe acute respiratory syndrome coronavirus 2 infection, experienced by 38 participants, boosted IgG levels and neutralization above those induced by vaccination alone. Nevertheless, BA.1-specific neutralization remained significantly lower than wild-type, with BA.5-specific neutralization lower still. Higher Omicron BA.1-specific neutralization 1 month after third dose was an independent correlate of lower SARS-CoV-2 infection risk. Conclusions: Results underscore the immune benefits of the third COVID-19 mRNA vaccine dose in adults of all ages and identify vaccine-induced Omicron-specific neutralization as a correlate of protective immunity. Systemic antibody responses and functions however, particularly Omicron-specific neutralization, decline rapidly in COVID-19-naive individuals, particularly in older adults, supporting the need for additional booster doses.

9.
J Appl Lab Med ; 8(1): 41-52, 2023 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-36610407

RESUMO

BACKGROUND: Due to supply chain shortages of reagents for real-time (RT)-PCR for SARS-CoV-2 and increasing demand on technical staff, an end-to-end data automation strategy for SARS-CoV-2 sample pooling and singleton analysis became necessary in the summer of 2020. METHODS: Using entirely open source software tools-Linux, bash, R, RShiny, ShinyProxy, and Docker-we developed a modular software application stack to manage the preanalytical, analytical, and postanalytical processes for singleton and pooled testing in a 5-week time frame. RESULTS: Pooling was operationalized for 81 days, during which time 64 pooled runs were performed for a total of 5320 sample pools and approximately 21 280 patient samples in 4:1 format. A total of 17 580 negative pooled results were released in bulk. After pooling was discontinued, the application stack was used for singleton analysis and modified to release all viral RT-PCR results from our laboratory. To date, 236 109 samples have been processed avoiding over 610 000 transcriptions. CONCLUSIONS: We present an end-to-end data automation strategy connecting 11 devices, one network attached storage, 2 Linux servers, and the laboratory information system.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/epidemiologia , Teste para COVID-19 , Reação em Cadeia da Polimerase em Tempo Real
10.
J Infect Dis ; 227(7): 838-849, 2023 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-35668700

RESUMO

BACKGROUND: Longer-term humoral responses to 2-dose coronavirus disease 2019 (COVID-19) vaccines remain incompletely characterized in people living with human immunodeficiency virus (HIV) (PLWH), as do initial responses to a third dose. METHODS: We measured antibodies against the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein receptor-binding domain, angiotensin-converting enzyme 2 (ACE2) displacement, and viral neutralization against wild-type and Omicron strains up to 6 months after 2-dose vaccination, and 1 month after the third dose, in 99 PLWH receiving suppressive antiretroviral therapy and 152 controls. RESULTS: Although humoral responses naturally decline after 2-dose vaccination, we found no evidence of lower antibody concentrations or faster rates of antibody decline in PLWH compared with controls after accounting for sociodemographic, health, and vaccine-related factors. We also found no evidence of poorer viral neutralization in PLWH after 2 doses, nor evidence that a low nadir CD4+ T-cell count compromised responses. Post-third-dose humoral responses substantially exceeded post-second-dose levels, though Omicron-specific responses were consistently weaker than responses against wild-type virus. Nevertheless, post-third-dose responses in PLWH were comparable to or higher than controls. An mRNA-1273 third dose was the strongest consistent correlate of higher post-third-dose responses. CONCLUSION: PLWH receiving suppressive antiretroviral therapy mount strong antibody responses after 2- and 3-dose COVID-19 vaccination. Results underscore the immune benefits of third doses in light of Omicron.


Assuntos
COVID-19 , Infecções por HIV , Humanos , HIV , Vacinas contra COVID-19 , COVID-19/prevenção & controle , SARS-CoV-2 , Anticorpos , Vacinação , Infecções por HIV/tratamento farmacológico , Anticorpos Antivirais
12.
Front Immunol ; 13: 947021, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36148225

RESUMO

SARS-CoV-2 Omicron infections are common among individuals who are vaccinated or have recovered from prior variant infection, but few reports have immunologically assessed serial Omicron infections. We characterized SARS-CoV-2 humoral responses in an individual who acquired laboratory-confirmed Omicron BA.1.15 ten weeks after a third dose of BNT162b2, and BA.2 thirteen weeks later. Responses were compared to 124 COVID-19-naive vaccinees. One month post-second and -third vaccine doses, the participant's wild-type and BA.1-specific IgG, ACE2-displacement and virus neutralization activities were average for a COVID-19-naive triple-vaccinated individual. BA.1 infection boosted the participant's responses to the cohort ≥95th percentile, but even this strong "hybrid" immunity failed to protect against BA.2. Reinfection increased BA.1 and BA.2-specific responses only modestly. Though vaccines clearly protect against severe disease, results highlight the continued importance of maintaining additional protective measures to counteract the immune-evasive Omicron variant, particularly as vaccine-induced immune responses naturally decline over time.


Assuntos
COVID-19 , Vacinas Virais , Enzima de Conversão de Angiotensina 2 , Anticorpos Antivirais , Vacina BNT162 , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Humanos , Imunoglobulina G , SARS-CoV-2 , Vacinação
13.
Methods Mol Biol ; 2546: 45-54, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36127577

RESUMO

Accurate determination of serum and plasma aldosterone is essential for screening, diagnosis, and subtype classification of primary aldosteronism (PA). Its measurement is also used in the investigation of adrenal incidentaloma, adrenal carcinoma, Addison's disease, congenital adrenal hyperplasia, renal artery stenosis, and renal tubular channelopathies. We describe a simple and robust method for the accurate and precise measurement of aldosterone in serum or plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). After addition of internal standard, aldosterone is extracted from serum samples using supported liquid extraction (SLE) with methyl tert-butyl ether (MtBE). The MtBE is evaporated to dryness, and the sample is reconstituted with mobile phase before injection onto the LC-MS/MS and quantitation using an eight-point calibration curve. The assay calibration range is approximately 50-6500 pM (0.16-234 ng/dL) with total imprecision between 6.8% and 4.1% for concentrations between about 50 and 1000 pM, respectively.


Assuntos
Aldosterona , Éteres Metílicos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos
14.
Methods Mol Biol ; 2546: 205-216, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36127591

RESUMO

Serum IgG subclasses (IgGSC) are measured for a number of indications, but the most common are the identification of selective immunodeficiency disease and the diagnosis of IgG4-related disease (IgG4RD). Traditional nephelometric (IN) assays can suffer from two issues impacting the accuracy of the results: (1) hook effect and (2) antibody cross-reactivity between the subclasses. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is not vulnerable to these modes of interference and therefore serves as an excellent and relatively inexpensive means of diagnosing and/or monitoring the relevant clinical conditions.We describe a semiautomated and simple method for the accurate and precise measurement of IgGSC from 20 µL of serum using a liquid chromatography and tandem mass spectrometry (LC-MS/MS) method following digestion of serum proteins in 96-well plate format. Due to the high abundance of the target proteins, no specialized sample preparation (such as solid phase extraction) is required. Twenty microliters are injected to the LC-MS/MS system. Quantitation is performed against a five-point duplicate linear calibration curve prepared in blank matrix. The assay calibration range is 0.38-7.74 g/L for IgG1, 0.24-4.46 g/L for IgG2, 0.038-0.752 g/L for IgG3, 0.025-0.435 g/L for IgG4, and 0.62-15.5 g/L for total IgG. Total IgG is used as an internal quality control marker and is compared to the sum of the four subclass results. Total imprecision in clinical production has been observed to be 5.1-10.6% for in-house prepared control materials having IgGSC mean values in the range of 0.38-8.43 g/L for IgG1, 0.22-3.76 g/L for IgG2, 0.0387-0.721 g/L for Ig3, and 0.0279-1.46 g/L for IgG4. Limit of quantitation (LoQ) was determined to be 0.29 g/L for IgG1, 0.22 g/L for IgG2, 0.019 g/L for IgG3, and 0.0067 g/L for IgG4.


Assuntos
Imunoglobulina G , Espectrometria de Massas em Tandem , Calibragem , Cromatografia Líquida/métodos , Nefelometria e Turbidimetria , Espectrometria de Massas em Tandem/métodos
15.
Methods Mol Biol ; 2546: 439-450, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36127611

RESUMO

Accurate determination of plasma renin activity (PRA) is essential for the development and maintenance of an effective screening program for primary aldosteronism (PA). PRA measurement can also be useful in the investigation of renal artery stenosis, syndrome of mineralocorticoid excess, Addison's disease, congenital adrenal hyperplasia, Bartters and Gitelman syndromes, and for inherited defects in the renin angiotensin aldosterone system (RAAS). We describe a semiautomated and simple method for the accurate and precise measurement of PRA from 500 µL of plasma (250 µL if blank subtraction is omitted, as discussed) using a liquid chromatography and tandem mass spectrometry (LC-MS/MS) method for angiotensin I (AngI) in 96-well format. After a 3 h AngI generation step at 37 °C in buffering conditions at pH 6, the reaction is quenched with 10% formic acid containing AngI internal standard. Sample preparation then proceeds with offline solid phase extraction, two wash steps, and methanol elution followed by injection into the LC-MS/MS system. Quantitation is performed against a 7-point calibration linear curve prepared in buffer. The assay calibration range is 0.34-30.0 ng/mL, which corresponds to PRA values of 0.11-10.0 ng/mL/h: much wider than was possible using traditional competitive antibody-based methods. Total precision in clinical production has been observed to be 5.8-5.0% for BioRad Hypertension Control materials having nominal PRA values ranging from 1.73 to 12.43 ng/mL/h. At AngI concentrations of 0.06 ng/L (corresponding to a PRA of 0.02 ng/mL/h), signal-to-noise ratio is 50:1, indicating that the limit of quantitation is well below the level required for clinical use.


Assuntos
Renina , Espectrometria de Massas em Tandem , Angiotensina I , Cromatografia Líquida/métodos , Metanol , Mineralocorticoides , Espectrometria de Massas em Tandem/métodos
16.
Methods Mol Biol ; 2546: 473-483, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36127614

RESUMO

Accurate measurement of thyrogloblulin (Tg) at low concentrations is essential for recurrence-monitoring in patients who have been treated for papillary and follicular thyroid cancers. The immunoassays commonly employed by clinical laboratories to measure Tg are known to suffer interferences from thyroglobulin autoantibodies (TgAb).We describe a semiautomated stable isotope standards and capture by antipeptide antibodies (SISCAPA®) LC-MS/MS method for the accurate and precise measurement of Tg using 400 uL of serum. Following trypsin digestion of serum proteins in a 96-well plate format, a Tg-specific peptide is captured and concentrated using a monoclonal antibody bound to protein G-coated paramagnetic beads. Eighteen microliters of concentrate are injected into the LC-MS/MS system. Quantitation is performed against a 6-point linear calibration curve prepared in a blank matrix. The assay calibration range is 0.1-10 ng/mL, the range of clinical interest for recurrence detection. Total imprecision in clinical production has been observed to be 13.8% and 6.54% for in-house prepared control materials having Tg concentrations of 0.24 ng/mL and 0.94 ng/mL, respectively. Limit of quantitation was determined to be 0.1 ng/mL.


Assuntos
Espectrometria de Massas em Tandem , Tireoglobulina , Anticorpos Monoclonais , Autoanticorpos , Cromatografia Líquida/métodos , Humanos , Espectrometria de Massas em Tandem/métodos , Tripsina
17.
J Appl Lab Med ; 7(5): 1025-1036, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35723286

RESUMO

BACKGROUND: To support the implementation of high-throughput pipelines suitable for SARS-CoV-2 sequencing and analysis in a clinical laboratory, we developed an automated sample preparation and analysis workflow. METHODS: We used the established ARTIC protocol with approximately 400 bp amplicons sequenced on Oxford Nanopore's MinION. Sequences were analyzed using Nextclade, assigning both a clade and quality score to each sample. RESULTS: A total of 2179 samples on twenty-five 96-well plates were sequenced. Plates of purified RNA were processed within 12 h, sequencing required up to 24 h, and analysis of each pooled plate required 1 h. The use of samples with known threshold cycle (Ct) values enabled normalization, acted as a quality control check, and revealed a strong correlation between sample Ct values and successful analysis, with 85% of samples with Ct < 30 achieving a "good" Nextclade score. Less abundant samples responded to enrichment with the fraction of Ct > 30 samples achieving a "good" classification rising by 60% after addition of a post-ARTIC PCR normalization. Serial dilutions of 3 variant of concern samples, diluted from approximately Ct = 16 to approximately Ct = 50, demonstrated successful sequencing to Ct = 37. The sample set contained a median of 24 mutations per sample and a total of 1281 unique mutations with reduced sequence read coverage noted in some regions of some samples. A total of 10 separate strains were observed in the sample set, including 3 variants of concern prevalent in British Columbia in the spring of 2021. CONCLUSIONS: We demonstrated a robust automated sequencing pipeline that takes advantage of input Ct values to improve reliability.


Assuntos
COVID-19 , Sequenciamento por Nanoporos , Nanoporos , COVID-19/diagnóstico , COVID-19/epidemiologia , Humanos , Reprodutibilidade dos Testes , SARS-CoV-2/genética
18.
J Infect Dis ; 226(6): 983-994, 2022 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-35543278

RESUMO

BACKGROUND: Third coronavirus disease 2019 (COVID-19) vaccine doses are broadly recommended, but immunogenicity data remain limited, particularly in older adults. METHODS: We measured circulating antibodies against the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein receptor-binding domain, ACE2 displacement, and virus neutralization against ancestral and omicron (BA.1) strains from prevaccine up to 1 month following the third dose, in 151 adults aged 24-98 years who received COVID-19 mRNA vaccines. RESULTS: Following 2 vaccine doses, humoral immunity was weaker, less functional, and less durable in older adults, where a higher number of chronic health conditions was a key correlate of weaker responses and poorer durability. One month after the third dose, antibody concentrations and function exceeded post-second-dose levels, and responses in older adults were comparable in magnitude to those in younger adults at this time. Humoral responses against omicron were universally weaker than against the ancestral strain after both the second and third doses. Nevertheless, after 3 doses, anti-omicron responses in older adults reached equivalence to those in younger adults. One month after 3 vaccine doses, the number of chronic health conditions, but not age, was the strongest consistent correlate of weaker humoral responses. CONCLUSIONS: Results underscore the immune benefits of third COVID-19 vaccine doses, particularly in older adults.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Idoso , Enzima de Conversão de Angiotensina 2 , Anticorpos Neutralizantes , Anticorpos Antivirais , COVID-19/prevenção & controle , Humanos , RNA Mensageiro , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Vacinas Sintéticas , Vacinas de mRNA
19.
20.
PLoS One ; 17(1): e0262345, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35051203

RESUMO

This study aimed to investigate the survival and efficacy indicators of human thyroid tissue transplantation into a retrievable, prevascularized implanted Sernova Corp Cell Pouch™ (CP) device. Thyroid tissue from human donors was transplanted subcutaneously into the pre-implanted CP device or into the subcutaneous (SC) space alone as a control in a nude Mus musculus model. Transplanted M. musculus were monitored for human serum thyroglobulin (TG) levels for 3 months until the transplants were removed for histological assessment. Human thyroid tissue survived and continued to produce TG in transplanted nude M. musculus in the CP, with no adverse events. CP transplants exhibited more persistent and robust production of human TG than tissue placed in the SC space alone from 3 to 13 weeks post transplantation. Fresh thyroid transplants had better survival and function compared to cryopreserved transplants. Thyroid transplant viability correlated with TG levels at 3 months post-transplant (p = 0.03). Immunofluorescence staining of transplants for TG and TPO localized in thyroid follicles. Human thyroid tissue transplanted into the subcutaneously implanted pre-vascularized CP in nude M. musculus survived and continued to produce robust and persistent human TG and warrants further investigation as a treatment for postoperative hypothyroidism.


Assuntos
Sobrevivência de Enxerto/fisiologia , Transplante de Órgãos/métodos , Glândula Tireoide/transplante , Animais , Humanos , Camundongos , Camundongos Nus , Transplante Heterólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA