Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Radiol Cardiothorac Imaging ; 6(4): e230339, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-39145734

RESUMO

Purpose To clarify the predominant causative plaque constituent for periprocedural myocardial injury (PMI) following percutaneous coronary intervention: (a) erythrocyte-derived materials, indicated by a high plaque-to-myocardium signal intensity ratio (PMR) at coronary atherosclerosis T1-weighted characterization (CATCH) MRI, or (b) lipids, represented by a high maximum 4-mm lipid core burden index (maxLCBI4 mm) at near-infrared spectroscopy intravascular US (NIRS-IVUS). Materials and Methods This retrospective study included consecutive patients who underwent CATCH MRI before elective NIRS-IVUS-guided percutaneous coronary intervention at two facilities. PMI was defined as post-percutaneous coronary intervention troponin T values greater than five times the upper reference limit. Multivariable analysis was performed to identify predictors of PMI. Finally, the predictive capabilities of MRI, NIRS-IVUS, and their combination were compared. Results A total of 103 lesions from 103 patients (median age, 72 years [IQR, 64-78]; 78 male patients) were included. PMI occurred in 36 lesions. In multivariable analysis, PMR emerged as the strongest predictor (P = .001), whereas maxLCBI4 mm was not a significant predictor (P = .07). When PMR was excluded from the analysis, maxLCBI4 mm emerged as the sole independent predictor (P = .02). The combination of MRI and NIRS-IVUS yielded the largest area under the receiver operating curve (0.86 [95% CI: 0.64, 0.83]), surpassing that of NIRS-IVUS alone (0.75 [95% CI: 0.64, 0.83]; P = .02) or MRI alone (0.80 [95% CI: 0.68, 0.88]; P = .30). Conclusion Erythrocyte-derived materials in plaques, represented by a high PMR at CATCH MRI, were strongly associated with PMI independent of lipids. MRI may play a crucial role in predicting PMI by offering unique pathologic insights into plaques, distinct from those provided by NIRS. Keywords: Coronary Plaque, Periprocedural Myocardial Injury, MRI, Near-Infrared Spectroscopy Intravascular US Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Intervenção Coronária Percutânea , Placa Aterosclerótica , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Masculino , Feminino , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Idoso , Placa Aterosclerótica/diagnóstico por imagem , Estudos Retrospectivos , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Valor Preditivo dos Testes , Ultrassonografia de Intervenção/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/patologia
2.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 80(7): 741-749, 2024 Jul 20.
Artigo em Japonês | MEDLINE | ID: mdl-38866536

RESUMO

A diffusion-weighted whole body imaging with background body signal suppression (DWIBS) is usually imaged as a whole body with Transverse (Tra). However, Tra has a large number of stations and a larger number than Coronal (Cor), so the scan time is longer. There are also drawbacks, such as signal unevenness between series. It is known that the effect of distortion is large in Cor. There is no report on it in Sagittal (Sag). Therefore, in this study, we focused on Sag and examined the imaging time, image distortion, fat suppression effect, and continuity between stations. In the examination by the phantom, the scan time was the shortest for Cor and the longest for Sag. In the strain evaluation, the effect of strain could be suppressed compared to Cor by using a rectangle field of view (FOV) in the anterior to posterior (AP) direction in Tra and Sag. There was no difference in the fat suppression effect depending on the imaging direction. Similar results were obtained in a study of 10 healthy volunteers, with Sag having the best continuity between stations.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagens de Fantasmas , Imagem Corporal Total , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Corporal Total/métodos , Masculino , Adulto , Feminino
3.
J Cardiovasc Magn Reson ; 26(1): 100999, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38237903

RESUMO

BACKGROUND: High-intensity plaque (HIP) on magnetic resonance imaging (MRI) has been documented as a powerful predictor of periprocedural myocardial injury (PMI) following percutaneous coronary intervention (PCI). Despite the recent proposal of three-dimensional HIP quantification to enhance the predictive capability, the conventional pulse sequence, which necessitates the separate acquisition of anatomical reference images, hinders accurate three-dimensional segmentation along the coronary vasculature. Coronary atherosclerosis T1-weighted characterization (CATCH) enables the simultaneous acquisition of inherently coregistered dark-blood plaque and bright-blood coronary artery images. We aimed to develop a novel HIP quantification approach using CATCH and to ascertain its superior predictive performance compared to the conventional two-dimensional assessment based on plaque-to-myocardium signal intensity ratio (PMR). METHODS: In this prospective study, CATCH MRI was conducted before elective stent implantation in 137 lesions from 125 patients. On CATCH images, dedicated software automatically generated tubular three-dimensional volumes of interest on the dark-blood plaque images along the coronary vasculature, based on the precisely matched bright-blood coronary artery images, and subsequently computed PMR and HIP volume (HIPvol). Specifically, HIPvol was calculated as the volume of voxels with signal intensity exceeding that of the myocardium, weighted by their respective signal intensities. PMI was defined as post-PCI cardiac troponin-T > 5 × the upper reference limit. RESULTS: The entire analysis process was completed within 3 min per lesion. PMI occurred in 44 lesions. Based on the receiver operating characteristic curve analysis, HIPvol outperformed PMR for predicting PMI (C-statistics, 0.870 [95% CI, 0.805-0.936] vs. 0.787 [95% CI, 0.706-0.868]; p = 0.001). This result was primarily driven by the higher sensitivity HIPvol offered: 0.886 (95% CI, 0.754-0.962) vs. 0.750 for PMR (95% CI, 0.597-0.868; p = 0.034). Multivariable analysis identified HIPvol as an independent predictor of PMI (odds ratio, 1.15 per 10-µL increase; 95% CI, 1.01-1.30, p = 0.035). CONCLUSIONS: Our semi-automated method of analyzing coronary plaque using CATCH MRI provided rapid HIP quantification. Three-dimensional assessment using this approach had a better ability to predict PMI than conventional two-dimensional assessment.


Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Intervenção Coronária Percutânea , Placa Aterosclerótica , Valor Preditivo dos Testes , Humanos , Masculino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Estudos Prospectivos , Feminino , Pessoa de Meia-Idade , Idoso , Intervenção Coronária Percutânea/efeitos adversos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Fatores de Risco , Resultado do Tratamento , Stents , Área Sob a Curva , Curva ROC , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA