Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
EClinicalMedicine ; 71: 102580, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38618206

RESUMO

Background: The pathological examination of lymph node metastasis (LNM) is crucial for treating prostate cancer (PCa). However, the limitations with naked-eye detection and pathologist workload contribute to a high missed-diagnosis rate for nodal micrometastasis. We aimed to develop an artificial intelligence (AI)-based, time-efficient, and high-precision PCa LNM detector (ProCaLNMD) and evaluate its clinical application value. Methods: In this multicentre, retrospective, diagnostic study, consecutive patients with PCa who underwent radical prostatectomy and pelvic lymph node dissection at five centres between Sep 2, 2013 and Apr 28, 2023 were included, and histopathological slides of resected lymph nodes were collected and digitised as whole-slide images for model development and validation. ProCaLNMD was trained at a dataset from a single centre (the Sun Yat-sen Memorial Hospital of Sun Yat-sen University [SYSMH]), and externally validated in the other four centres. A bladder cancer dataset from SYSMH was used to further validate ProCaLNMD, and an additional validation (human-AI comparison and collaboration study) containing consecutive patients with PCa from SYSMH was implemented to evaluate the application value of integrating ProCaLNMD into the clinical workflow. The primary endpoint was the area under the receiver operating characteristic curve (AUROC) of ProCaLNMD. In addition, the performance measures for pathologists with ProCaLNMD assistance was also assessed. Findings: In total, 8225 slides from 1297 patients with PCa were collected and digitised. Overall, 8158 slides (18,761 lymph nodes) from 1297 patients with PCa (median age 68 years [interquartile range 64-73]; 331 [26%] with LNM) were used to train and validate ProCaLNMD. The AUROC of ProCaLNMD ranged from 0.975 (95% confidence interval 0.953-0.998) to 0.992 (0.982-1.000) in the training and validation datasets, with sensitivities > 0.955 and specificities > 0.921. ProCaLNMD also demonstrated an AUROC of 0.979 in the cross-cancer dataset. ProCaLNMD use triggered true reclassification in 43 (4.3%) slides in which micrometastatic tumour regions were initially missed by pathologists, thereby correcting 28 (8.5%) missed-diagnosed cases of previous routine pathological reports. In the human-AI comparison and collaboration study, the sensitivity of ProCaLNMD (0.983 [0.908-1.000]) surpassed that of two junior pathologists (0.862 [0.746-0.939], P = 0.023; 0.879 [0.767-0.950], P = 0.041) by 10-12% and showed no difference to that of two senior pathologists (both 0.983 [0.908-1.000], both P > 0.99). Furthermore, ProCaLNMD significantly boosted the diagnostic sensitivity of two junior pathologists (both P = 0.041) to the level of senior pathologists (both P > 0.99), and substantially reduced the four pathologists' slide reviewing time (-31%, P < 0.0001; -34%, P < 0.0001; -29%, P < 0.0001; and -27%, P = 0.00031). Interpretation: ProCaLNMD demonstrated high diagnostic capabilities for identifying LNM in prostate cancer, reducing the likelihood of missed diagnoses by pathologists and decreasing the slide reviewing time, highlighting its potential for clinical application. Funding: National Natural Science Foundation of China, the Science and Technology Planning Project of Guangdong Province, the National Key Research and Development Programme of China, the Guangdong Provincial Clinical Research Centre for Urological Diseases, and the Science and Technology Projects in Guangzhou.

2.
EClinicalMedicine ; 71: 102566, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38686219

RESUMO

Background: Urine cytology is an important non-invasive examination for urothelial carcinoma (UC) diagnosis and follow-up. We aimed to explore whether artificial intelligence (AI) can enhance the sensitivity of urine cytology and help avoid unnecessary endoscopy. Methods: In this multicentre diagnostic study, consecutive patients who underwent liquid-based urine cytology examinations at four hospitals in China were included for model development and validation. Patients who declined surgery and lacked associated histopathology results, those diagnosed with rare subtype tumours of the urinary tract, or had low-quality images were excluded from the study. All liquid-based cytology slides were scanned into whole-slide images (WSIs) at 40 × magnification and the WSI-labels were derived from the corresponding histopathology results. The Precision Urine Cytology AI Solution (PUCAS) was composed of three distinct stages (patch extraction, features extraction, and classification diagnosis) and was trained to identify important WSI features associated with UC diagnosis. The diagnostic sensitivity was mainly used to validate the performance of PUCAS in retrospective and prospective validation cohorts. This study is registered with the ChiCTR, ChiCTR2300073192. Findings: Between January 1, 2018 and October 31, 2022, 2641 patients were retrospectively recruited in the training cohort, and 2335 in retrospective validation cohorts; 400 eligible patients were enrolled in the prospective validation cohort between July 7, 2023 and September 15, 2023. The sensitivity of PUCAS ranged from 0.922 (95% CI: 0.811-0.978) to 1.000 (0.782-1.000) in retrospective validation cohorts, and was 0.896 (0.837-0.939) in prospective validation cohort. The PUCAS model also exhibited a good performance in detecting malignancy within atypical urothelial cells cases, with a sensitivity of over 0.84. In the recurrence detection scenario, PUCAS could reduce 57.5% of endoscopy use with a negative predictive value of 96.4%. Interpretation: PUCAS may help to improve the sensitivity of urine cytology, reduce misdiagnoses of UC, avoid unnecessary endoscopy, and reduce the clinical burden in resource-limited areas. The further validation in other countries is needed. Funding: National Natural Science Foundation of China; Key Program of the National Natural Science Foundation of China; the National Science Foundation for Distinguished Young Scholars; the Science and Technology Planning Project of Guangdong Province; the National Key Research and Development Programme of China; Guangdong Provincial Clinical Research Centre for Urological Diseases.

4.
Lancet Oncol ; 24(4): 360-370, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36893772

RESUMO

BACKGROUND: Accurate lymph node staging is important for the diagnosis and treatment of patients with bladder cancer. We aimed to develop a lymph node metastases diagnostic model (LNMDM) on whole slide images and to assess the clinical effect of an artificial intelligence-assisted (AI) workflow. METHODS: In this retrospective, multicentre, diagnostic study in China, we included consecutive patients with bladder cancer who had radical cystectomy and pelvic lymph node dissection, and from whom whole slide images of lymph node sections were available, for model development. We excluded patients with non-bladder cancer and concurrent surgery, or low-quality images. Patients from two hospitals (Sun Yat-sen Memorial Hospital of Sun Yat-sen University and Zhujiang Hospital of Southern Medical University, Guangzhou, Guangdong, China) were assigned before a cutoff date to a training set and after the date to internal validation sets for each hospital. Patients from three other hospitals (the Third Affiliated Hospital of Sun Yat-sen University, Nanfang Hospital of Southern Medical University, and the Third Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong, China) were included as external validation sets. A validation subset of challenging cases from the five validation sets was used to compare performance between the LNMDM and pathologists, and two other datasets (breast cancer from the CAMELYON16 dataset and prostate cancer from the Sun Yat-sen Memorial Hospital of Sun Yat-sen University) were collected for a multi-cancer test. The primary endpoint was diagnostic sensitivity in the four prespecified groups (ie, the five validation sets, a single-lymph-node test set, the multi-cancer test set, and the subset for a performance comparison between the LNMDM and pathologists). FINDINGS: Between Jan 1, 2013 and Dec 31, 2021, 1012 patients with bladder cancer had radical cystectomy and pelvic lymph node dissection and were included (8177 images and 20 954 lymph nodes). We excluded 14 patients (165 images) with concurrent non-bladder cancer and also excluded 21 low-quality images. We included 998 patients and 7991 images (881 [88%] men; 117 [12%] women; median age 64 years [IQR 56-72]; ethnicity data not available; 268 [27%] with lymph node metastases) to develop the LNMDM. The area under the curve (AUC) for accurate diagnosis of the LNMDM ranged from 0·978 (95% CI 0·960-0·996) to 0·998 (0·996-1·000) in the five validation sets. Performance comparisons between the LNMDM and pathologists showed that the diagnostic sensitivity of the model (0·983 [95% CI 0·941-0·998]) substantially exceeded that of both junior pathologists (0·906 [0·871-0·934]) and senior pathologists (0·947 [0·919-0·968]), and that AI assistance improved sensitivity for both junior (from 0·906 without AI to 0·953 with AI) and senior (from 0·947 to 0·986) pathologists. In the multi-cancer test, the LNMDM maintained an AUC of 0·943 (95% CI 0·918-0·969) in breast cancer images and 0·922 (0·884-0·960) in prostate cancer images. In 13 patients, the LNMDM detected tumour micrometastases that had been missed by pathologists who had previously classified these patients' results as negative. Receiver operating characteristic curves showed that the LNMDM would enable pathologists to exclude 80-92% of negative slides while maintaining 100% sensitivity in clinical application. INTERPRETATION: We developed an AI-based diagnostic model that did well in detecting lymph node metastases, particularly micrometastases. The LNMDM showed substantial potential for clinical applications in improving the accuracy and efficiency of pathologists' work. FUNDING: National Natural Science Foundation of China, the Science and Technology Planning Project of Guangdong Province, the National Key Research and Development Programme of China, and the Guangdong Provincial Clinical Research Centre for Urological Diseases.


Assuntos
Inteligência Artificial , Metástase Linfática , Neoplasias da Bexiga Urinária , Neoplasias da Bexiga Urinária/patologia , Metástase Linfática/diagnóstico , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos
5.
J Transl Med ; 21(1): 42, 2023 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-36691055

RESUMO

BACKGROUND: Accurate pathological diagnosis of invasion depth and histologic grade is key for clinical management in patients with bladder cancer (BCa), but it is labour-intensive, experience-dependent and subject to interobserver variability. Here, we aimed to develop a pathological artificial intelligence diagnostic model (PAIDM) for BCa diagnosis. METHODS: A total of 854 whole slide images (WSIs) from 692 patients were included and divided into training and validation sets. The PAIDM was developed using the training set based on the deep learning algorithm ScanNet, and the performance was verified at the patch level in validation set 1 and at the WSI level in validation set 2. An independent validation cohort (validation set 3) was employed to compare the PAIDM and pathologists. Model performance was evaluated using the area under the curve (AUC), accuracy, sensitivity, specificity, positive predictive value and negative predictive value. RESULTS: The AUCs of the PAIDM were 0.878 (95% CI 0.875-0.881) at the patch level in validation set 1 and 0.870 (95% CI 0.805-0.923) at the WSI level in validation set 2. In comparing the PAIDM and pathologists, the PAIDM achieved an AUC of 0.847 (95% CI 0.779-0.905), which was non-inferior to the average diagnostic level of pathologists. There was high consistency between the model-predicted and manually annotated areas, improving the PAIDM's interpretability. CONCLUSIONS: We reported an artificial intelligence-based diagnostic model for BCa that performed well in identifying invasion depth and histologic grade. Importantly, the PAIDM performed admirably in patch-level recognition, with a promising application for transurethral resection specimens.


Assuntos
Inteligência Artificial , Neoplasias da Bexiga Urinária , Humanos , Algoritmos , Valor Preditivo dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA