Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Gels ; 9(3)2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36975681

RESUMO

With the occurrence of breast implant crises in Korea, it has become increasingly important to detect complications earlier in patients receiving a device. We have therefore combined imaging modalities with an implant-based augmentation mammaplasty. In this study, we assessed the short-term treatment outcomes and safety of the Motiva ErgonomixTM Round SilkSurface (Establishment Labs Holdings Inc., Alajuela, Costa Rica) in Korean women. A total of 87 women (n = 87) were included in the current study. We compared preoperative anthropometric measurements between the right side and the left side of the breast. Moreover, we also compared the thickness of the skin, subcutaneous tissue and the pectoralis major measured on a breast ultrasound preoperatively and 3 months postoperatively. Furthermore, we analyzed the incidences of postoperative complications and the cumulative complication-free survival. Preoperatively, there was a significant difference in the distance from the nipple to the midline between the left and right side of the breast (p = 0.000). Both sides of the breast showed significant differences in the thickness of the pectoralis major preoperatively and 3 months postoperatively (p = 0.000). A total of 11 cases (12.6%) of postoperative complications occurred; these included five cases (5.7%) of early seroma, two cases (2.3%) of infection, two cases (2.3%) of rippling, one case (1.1%) of hematoma and one case (1.1%) of capsular contracture. Time-to-events were estimated at 386.68 ± 27.79 days (95% CI 334.11-439.27). Here, we describe our experience with imaging modalities in combination with the Motiva ErgonomixTM Round SilkSurface in Korean women.

2.
J Korean Soc Radiol ; 83(6): 1373-1379, 2022 Nov.
Artigo em Coreano | MEDLINE | ID: mdl-36545423

RESUMO

Epithelioid hemangioendothelioma (EHE) is a low-grade malignant vascular neoplasm that can occur anywhere in the body. EHE has a low annual incidence (0.38/106) and prevalence (< 1/106), and primary mediastinal EHE is exceedingly rare. We report a case of EHE in a 53-year-old female which manifested as an incidentally discovered mass in the right paratracheal region. In this report, authors describe the pathological and radiological findings of primary mediastinal EHE invading the superior vena cava in the right paratracheal area.

4.
Medicine (Baltimore) ; 100(25): e26508, 2021 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-34160471

RESUMO

ABSTRACT: This study was conducted to examine whether Korean veterans from the US-Vietnam War who had a diagnosis of type II diabetes mellitus (T2DM) as well as past history of exposure to agent orange (AO) are vulnerable to hyperglycemia when receiving intra-articular corticosteroid injection (IACI) for pain relief.The current study included a total of 49 patients (n = 49) who received an injection of triamcinolone 20 or 40 mg to the shoulder under sonographic guidance or did that of dexamethasone 10 mg or triamcinolone 40 mg combined with dexamethasone 20 mg to the spine under fluoroscopic guidance. Their 7-day fasting blood glucose (FBG) levels were measured and then averaged, serving as baseline levels. This is followed by measurement of FBG levels for 14 days of IACI. Respective measurements were compared with baseline levels. The patients were also evaluated for whether there are increases in FBG levels depending on insulin therapy as well as HbA1c ≥ 7% or HbA1c < 7%.Overall, there were significant increases in FBG levels by 64.7 ±â€Š42.5 mg/dL at 1 day of IACI from baseline (P < .05). HbA1c ≥ 7% and HbA1c < 7% showed increases in FBG levels by 106.1 ±â€Š49.0 mg/dL and 46.5 ±â€Š3.8 mg/dL, respectively, at 1 day of IACI from baseline (P < .05). In the presence and absence of insulin therapy, there were significant increases in them by 122.6 ±â€Š48.7 mg/dL and 48.0 ±â€Š20.4 mg/dL, respectively, at 1 day of IACI from baseline (P < .05). But there were decreases in them to baseline levels at 2 days of IACI.Clinicians should consider the possibility of hyperglycemia when using corticosteroids for relief of musculoskeletal pain in Korean veterans from the US-Vietnam War who had a history of exposure to AO.


Assuntos
Agente Laranja/efeitos adversos , Artralgia/tratamento farmacológico , Diabetes Mellitus Tipo 2/complicações , Glucocorticoides/efeitos adversos , Hiperglicemia/epidemiologia , Transtornos de Estresse Pós-Traumáticos/epidemiologia , Idoso , Glicemia/análise , Dexametasona/administração & dosagem , Dexametasona/efeitos adversos , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/tratamento farmacológico , Seguimentos , Glucocorticoides/administração & dosagem , Humanos , Hiperglicemia/sangue , Hiperglicemia/diagnóstico , Hiperglicemia/etiologia , Injeções Intra-Articulares , Insulina/administração & dosagem , Masculino , República da Coreia/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Transtornos de Estresse Pós-Traumáticos/psicologia , Triancinolona/administração & dosagem , Triancinolona/efeitos adversos , Veteranos/psicologia , Veteranos/estatística & dados numéricos , Guerra do Vietnã , Exposição à Guerra/efeitos adversos
5.
Aesthetic Plast Surg ; 45(3): 895-903, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33649929

RESUMO

BACKGROUND: The Motiva Ergonomix™ Round SilkSurface (Establishment Labs Holdings Inc., Alajuela, Costa Rica) is the fifth generation of a silicone gel-filled breast implant that is commercially available in Korea. OBJECTIVES: In this study, we describe 4-year interim results of the safety of augmentation mammaplasty using the Motiva Ergonomix™ Round SilkSurface in Korean women. METHODS: In the current multicenter, retrospective study, we performed a retrospective review of medical records of a total of 1314 patients who received augmentation mammaplasty using the Motiva Ergonomix™ Round SilkSurface at our hospitals between September 1, 2016, and August 31, 2020. For safety assessment, we analyzed incidences of postoperative complications and Kaplan-Meier complication-free survival of the patients. RESULTS: We included a total of 873 patients (1746 breasts, mean age = 32.18 ± 6.88 years) in the current study. There were a total of 111 cases (12.70%) of postoperative complications; these include 24 cases (2.70%) of early seroma, 18 cases (2.10%) of hematoma, 18 cases (2.10%) of capsular contracture, 17 cases (1.95%) of dissatisfaction with shape, 16 cases (1.83%) of dissatisfaction with size, 9 cases (1.03%) of asymmetry, 6 cases (0.70%) of infection and 3 cases (0.34%) of rippling. Moreover, time-to-events were estimated at 918.34 ± 36.22 days (95% CI 845.44-988.52). CONCLUSIONS: Here, we describe 4-year interim results of the safety of augmentation mammaplasty using the Motiva Ergonomix™ Round SilkSurface in Korean women in a non-manufacturer-sponsored study. But further large-scale, prospective, multicenter studies with a long period of follow-up are warranted to establish our results. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Implante Mamário , Implantes de Mama , Mamoplastia , Adulto , Feminino , Seguimentos , Humanos , Mamoplastia/efeitos adversos , Estudos Prospectivos , República da Coreia , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA