Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J Cardiovasc Imaging ; 16(5): 521-30, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25651856

RESUMO

AIMS: To examine the utility of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) in the early diagnosis of cardiac implantable electronic device (CIED) generator pocket infection. METHODS AND RESULTS: A total of 86 patients with CIEDs were evaluated with (18)F-FDG PET/CT imaging: 46 with suspected generator pocket infection and 40 without any history of infection. (18)F-FDG activity in the region of the generator pocket was expressed as a semi-quantitative ratio (SQR)-defined as the maximum count rate around the CIED divided by the mean count rate between normal right and left lung parenchyma. All patients underwent standard clinical management, independent of the PET/CT result. Patients with suspected generator pocket infection that required CIED extraction (n = 32) had significantly higher (18)F-FDG activity compared with those that did not (n = 14), and compared with controls (n = 40) [SQR: 4.80 (3.18-7.05) vs. 1.40 (0.88-1.73) vs. 1.10 (0.98-1.40), respectively; P < 0.001]. On receiver operator characteristic analysis, SQR had a high diagnostic accuracy (area under curve = 0.98) for the early identification of patients with confirmed infection (i.e. those ultimately needing extraction)-with an optimal SQR cut-off value of >2.0 (sensitivity = 97%; specificity = 98%). CONCLUSION: This study highlights the potential benefits of evaluating patients with suspected CIED generator pocket infection using (18)F-FDG PET/CT. In this study, (18)F-FDG PET/CT had a high diagnostic accuracy in the early diagnosis of CIED generator pocket infection, even where initial clinical signs were underwhelming.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Infecções Relacionadas à Prótese/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo , Diagnóstico Precoce , Ecocardiografia , Feminino , Fluordesoxiglucose F18 , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infecções Relacionadas à Prótese/cirurgia , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA