Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Fujita Med J ; 10(2): 64-68, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38708076

RESUMO

Objectives: This study aimed to determine the incidence of bilateral macular holes (MHs), and to investigate the incidence and characteristics of retinal abnormalities in the fellow eyes, using high-definition optical coherence tomography (OCT). Methods: Medical records from 724 consecutive patients diagnosed with full-thickness MHs, who underwent surgery at Fujita Health University Hospital from May 2015 to March 2022, were retrospectively reviewed. Based on the exclusion criteria, 658 patients with idiopathic MHs were included. B-scan OCT images of the fellow eyes were used to identify vitreoretinal interface abnormalities, such as MHs, epiretinal membranes (ERMs), vitreomacular traction syndrome (VMTS) and lamellar macular holes (LMHs). Results: The mean age of the patients was 65.9±9.0 years. There were 292 males (44.4%) and 366 females (55.6%). There were 39 fellow eyes with MHs (5.9%), 77 with ERMs (11.7%), 32 with VMTS (4.9%) and 11 with LMHs (1.7%). Thirty-four fellow eyes (5.2%) could not be classified and 469 fellow eyes were normal (71.3%). Furthermore, the 39 bilateral MHs were divided into four stages according to the Gass classification, as follows: stage 1, 32 eyes (82.1%); stage 2, none (0%); stage 3, 5 eyes (12.8%); and stage 4, 2 eyes (5.1%). Conclusions: Vitreoretinal interface abnormalities, such as MHs, ERMs, VMTS and LMHs, are more common in the fellow eyes of patients with MHs than in the healthy population. The fellow eyes of patients with MHs should be carefully followed using OCT.

2.
Case Rep Ophthalmol ; 14(1): 288-294, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37485240

RESUMO

We report a case of a patient with autism spectrum disorder (ASD) and perforated keratomalacia secondary to vitamin A deficiency. A 6-year-old boy complained of difficulty in opening the eyelids. The ocular conjunctiva was hyperemic and keratinized with purulent ocular (eye) discharge. Both corneas showed epithelial defects with hypopyon. The serum vitamin A level was ≤5 IU/dL (normal 97-316), leading to a diagnosis of xerophthalmia and keratomalacia due to vitamin A deficiency. Intramuscular injection of vitamin A (50,000 IU/day), as well as oral administration of multivitamin (containing 2,500 IU of vitamin A) and zinc supplement at 50 mg/day, allowed him to open both eyes and show interest in tablet devices 14 days after the diagnosis. During the course of the treatment, corneal perforation was observed, but it was closed without contact lens wear or amniotic patch and managed with vitamin A replacement therapy and antimicrobial eye drops. The epithelium extended to the area of the right cornea that had been melted, and although scarring corneal opacity remained, there were no obvious signs of infection. Early diagnosis is difficult because children with ASD do not express complaints, and vitamin A deficiency should be considered in patients with a severely unbalanced diet and complaints of difficulty opening the eyelids.

4.
Fujita Med J ; 9(1): 41-46, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36789129

RESUMO

Objectives: To compare the eye axial length (AL), equatorial horizontal diameter (HD), and equatorial vertical diameter (VD) of normal eyes using a novel wide-angle, arc-scanning, ultrasound diagnostic device for wide-angle B-mode echography. Methods: In this cross-sectional study, wide-angle B-mode echography and magnetic resonance imaging (MRI) were conducted on 22 normal eyes; the AL, HD, and VD were measured. Results: The mean ALs were as follows: wide-angle B-mode echography, 25.22±1.47 mm and MRI, 25.24±1.46 mm; a significant correlation was observed between the two measurements (ß=0.995 [0.976, 1.013]; p<0.001; 95% R2=1.00). The mean HDs were as follows: wide-angle B-mode echography, 22.33±0.84 mm and MRI, 22.55±0.90 mm; a significant correlation was observed between the two measurements (ß=0.902 [0.750, 1.179]; p<0.001; 95% R2=0.81). The mean VDs were as follows: wide-angle B-mode echography, 22.77±0.91 mm; and MRI, 22.88±0.92 mm; a significant correlation was observed between the two measurements (ß=0.966 [0.853, 1.097]; p<0.001; 95% R2=0.93). Conclusions: There were no significant differences in the measurements for each parameter by wide-angle B-mode echography and MRI. Therefore, wide-angle B-mode echography permits accurate visualization of ocular morphology.

5.
Retina ; 43(4): 560-566, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36728024

RESUMO

PURPOSE: To investigate the influence of an excess inverted internal limiting membrane (ILM) flap that covers the fovea in idiopathic macular hole surgery on postoperative visual acuity and macular morphology. METHODS: This retrospective study included 66 patients with an idiopathic macular hole who underwent vitrectomy using the inverted ILM flap technique. They were divided into three groups: normal morphology (N), detached ILM (D), or ILM proliferation (P) in the parafoveal area. They were followed up for at least 6 months, and their best-corrected visual acuity, central retinal thickness, and parafoveal retinal thickness were measured. RESULTS: There were no significant differences in preoperative or postoperative mean best-corrected visual acuities or postoperative CRTs among the groups. The postoperative inferior parafoveal retinal thicknesses were 319.2 ± 38.0, 377.1 ± 60.6, and 373.1 ± 67.3 µ m in the N, D, and P groups, respectively (P vs. D group, P = 0.963; P vs. N group, P = 0.008; N vs. D group, P = 0.004). CONCLUSION: Regardless of the postoperative morphology of the inverted ILM flap, there was no effect on postoperative best-corrected visual acuity or CRT.


Assuntos
Perfurações Retinianas , Humanos , Perfurações Retinianas/cirurgia , Estudos Retrospectivos , Tomografia de Coerência Óptica , Retina , Fóvea Central , Vitrectomia/métodos , Membrana Basal/cirurgia
6.
Jpn J Ophthalmol ; 66(6): 543-548, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36346555

RESUMO

PURPOSE: To investigate the efficacy of modified internal limiting membrane (ILM) flap technique combined with vitreous surgery for treating macular holes and examine the outcomes in visual function and anatomic macular hole closure. STUDY DESIGN: Retrospective, observational. METHODS: Between July 1, 2015, and October 1, 2019, the modified inverted ILM flap technique combined with vitreous surgery was used to treat idiopathic macular holes, postoperative progression was then followed for at least 6 months in 96 participants (98 eyes). We modified the method by removing the lower half of the ILM while peeling and inverting the upper half. The mean age of the participants was 65.9 ± 11.9 years (41 men (42.7%) and 55 women (57.3%)). Retrospective evaluations of macular hole diameter, corrected visual acuity, and macular hole closure rates were performed using data from medical records. RESULTS: The mean macular hole diameter was 623.6 ± 207.4 µm. The mean corrected visual acuity (logMAR) was 0.79 ± 0.27 before surgery and 0.46 ± 0.35 at 1, 0.35 ± 0.39 at 3, and 0.31 ± 0.36 at 6 months Post surgery, showing significant differences before and after surgery (p = 2.30 × 10- 2). The macular hole closure rate was 98%. CONCLUSION: The modified inverted ILM flap technique combined with vitreous surgery was an effective method for treating macular holes, resulting in improvement in closure and visual acuity.


Assuntos
Membrana Epirretiniana , Perfurações Retinianas , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Perfurações Retinianas/diagnóstico , Perfurações Retinianas/cirurgia , Membrana Epirretiniana/diagnóstico , Membrana Epirretiniana/cirurgia , Vitrectomia/métodos , Membrana Basal/cirurgia , Estudos Retrospectivos , Tomografia de Coerência Óptica , Resultado do Tratamento
7.
Case Rep Ophthalmol Med ; 2022: 2841683, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36277508

RESUMO

Purpose: We report a case of neuroretinitis associated with cat scratch disease (CSD) in young children. Method: Case report. Results: A 16-month-old boy was admitted for a detailed examination and treatment of a fever of unknown origin. Blood tests revealed no significant findings other than a white blood cell count of 16,100/mm3 and C-reactive protein level of 9.89 mg/dL. Computed tomography revealed no relevant findings to determine the causative disease. Antibiotic therapy with cefotaxime was initiated; however, the fever did not resolve. The patient was referred to our department for further examination to detect the cause of the fever. Fundoscopy revealed neuroretinitis in the right eye. His mother reported a history of breeding cats. Cat scratch disease (CSD) was suspected based on the clinical course and fundus findings. Cefotaxime was discontinued, and azithromycin, rifampicin, and prednisolone were administered, following which the fever disappeared and fundus findings improved. Immunoglobulin G (IgG) and IgM antibodies against Bartonella henselae was positive, leading to a definitive diagnosis of CSD. Conclusion: Infants cannot complain of decreased visual acuity; therefore, these findings may be overlooked unless a fundus examination is performed. As in this case, the early detection of neuroretinitis by an ophthalmologist may help in the diagnosis of CSD. It is extremely difficult to capture a photograph of the fundus of an infant, and recording with a smartphone is relatively simple and useful for monitoring continuous changes. Summary. We describe a case of neuroretinitis associated with cat scratch disease (CSD) that was diagnosed on the basis of fundus findings. The findings suggest the importance of an aggressive ophthalmologic examination when CSD is suspected in young children who are unable to describe their symptoms.

8.
Hum Mutat ; 43(12): 2251-2264, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36284460

RESUMO

Inherited retinal diseases (IRDs) comprise a phenotypically and genetically heterogeneous group of ocular disorders that cause visual loss via progressive retinal degeneration. Here, we report the genetic characterization of 1210 IRD pedigrees enrolled through the Japan Eye Genetic Consortium and analyzed by whole exome sequencing. The most common phenotype was retinitis pigmentosa (RP, 43%), followed by macular dystrophy/cone- or cone-rod dystrophy (MD/CORD, 13%). In total, 67 causal genes were identified in 37% (448/1210) of the pedigrees. The first and second most frequently mutated genes were EYS and RP1, associated primarily with autosomal recessive (ar) RP, and RP and arMD/CORD, respectively. Examinations of variant frequency in total and by phenotype showed high accountability of a frequent EYS missense variant (c.2528G>A). In addition to the two known EYS founder mutations (c.4957dupA and c.8805C>G) of arRP, we observed a frequent RP1 variant (c.5797C>T) in patients with arMD/CORD.


Assuntos
Distrofias de Cones e Bastonetes , Degeneração Macular , Doenças Retinianas , Humanos , Sequenciamento do Exoma , Proteínas do Olho/genética , População do Leste Asiático , Mutação , Linhagem , Distrofias de Cones e Bastonetes/diagnóstico , Distrofias de Cones e Bastonetes/genética , Doenças Retinianas/genética , Degeneração Macular/genética , Análise Mutacional de DNA
9.
Case Rep Ophthalmol ; 13(2): 584-588, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36160490

RESUMO

We report a case of Fabry disease diagnosed after recurrent cerebral infarction in a patient with central retinal artery occlusion (CRAO). A 23-year-old man presented with vision loss in his right eye (20/2000), showing CRAO. There was no identified cause for the loss of vision; however, corneal verticillata was detected in both eyes on the recurrence of the cerebral infarction. The α-galactosidase activity in leukocytes was significantly reduced to <0.3 nmol/mg of protein/hour, leading to a definitive diagnosis of Fabry disease. Enzyme replacement therapy was commenced concomitant to rehabilitation. It is necessary to identify Fabry disease as a cause of CRAO in young individuals, and the detection of cornea verticillata, used frequently as an ocular finding, is helpful.

10.
Fujita Med J ; 8(1): 25-30, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35233344

RESUMO

OBJECTIVES: The purpose of this study was to examine the incidence of, and risk factors for, epiretinal membrane (ERM) surgery after an initial pars plana vitrectomy (PPV) for rhegmatogenous retinal detachment (RRD). METHODS: The records of consecutive patients (3,495 eyes of 3,387 patients) who underwent RRD repair at Fujita Health University Hospital between January 1, 2008, and February 28, 2019, were retrospectively reviewed. A total of 1,736 eyes without an ERM in preoperative optical coherence tomography were included in this study. RESULTS: The incidence of ERM surgery after RRD repair was 2.4%. The mean time from RRD repair to ERM surgery was 19.5±27.2 months. The odds ratios after adjusting for age and sex were as follows: the preoperative visual acuity (logarithm of the minimum angle of resolution, logMAR), 2.17 (p=0.02; 95% confidence interval [CI], 1.11-5.16); axial length, 1.38 (p=0.002; 95% CI, 1.12-1.72); 20-gauge vitreous surgery instruments, 3.82 (p<0.0001; 95% CI, 2.02-7.16); internal limiting membrane (ILM) peeling, 0.28 (p=0.033; 95% CI, 0.05-0.92). ERM surgery improved visual acuity from 0.36 to 0.01 logMAR, even at ≥1.5 years after RRD repair. CONCLUSIONS: Careful follow-up is required in the following cases: long axial length before RRD repair, low visual acuity, use of 20-gauge vitreous surgery instruments, and a lack of ILM peeling.

11.
Heliyon ; 7(9): e08059, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34632139

RESUMO

Visual dysfunction in patients with macular hole is believed to occur because of cone cell displacement, often measured by the Watzke-Allen test (WAT). However, it is unknown if the horizontal and vertical measurements recorded by WAT reflect the true extent of photoreceptor displacement. This study aimed to measure the extent of photoreceptor displacement in patients with macular hole using WAT and compare the displacement value with the hole diameter measured by optical coherence tomography (OCT). This prospective, observational study at a single tertiary referral center included 43 patients with macular hole. WAT thresholds were assessed for their ability to detect macular hole. The slit was presented vertically and horizontally, and the brightness of the monitor screen was 180 cd/m2. Horizontal and vertical WAT thresholds for distortion were measured. Correlations and performance evaluations were assessed by Pearson's correlation analysis and Wilcoxon rank-sum test, respectively, between WAT threshold values and hole diameters. Horizontal and vertical WAT thresholds and diameters were compared using paired t-tests. The mean vertical WAT threshold (1.95° ± 0.87°) was significantly higher than the mean horizontal threshold (1.71° ± 0.73°; P < 0.0001). The mean minimum horizontal hole diameter (303.42 ± 111.16 mm; visual angle, 1.01°) was significantly greater than the mean minimum vertical diameter (264.12 ± 107.88 mm; visual angle, 0.88°; P = 0.0149). The minimum vertical and horizontal macular hole diameters were positively correlated with the vertical and horizontal WAT threshold values (r = 0.514, P < 0.01; r = 0.447, P < 0.01, respectively). The WAT threshold values were greater than the respective minimum macular hole diameters, indicative of cone cells displacement over an area larger than that of the hole. The difference in the extent of vertical and horizontal distortions suggests asymmetric hole formation. Hence, WAT threshold values may help evaluate visual function in patients with macular hole.

12.
Cells ; 10(4)2021 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-33800535

RESUMO

Regenerative medicine in ophthalmology that uses induced pluripotent stem cells (iPS) cells has been described, but those studies used iPS cells derived from fibroblasts. Here, we generated iPS cells derived from iris cells that develop from the same inner layer of the optic cup as the retina, to regenerate retinal nerves. We first identified cells positive for p75NTR, a marker of retinal tissue stem and progenitor cells, in human iris tissue. We then reprogrammed the cultured p75NTR-positive iris tissue stem/progenitor (H-iris stem/progenitor) cells to create iris-derived iPS (H-iris iPS) cells for the first time. These cells were positive for iPS cell markers and showed pluripotency to differentiate into three germ layers. When H-iris iPS cells were pre-differentiated into neural stem/progenitor cells, not all cells became positive for neural stem/progenitor and nerve cell markers. When these cells were pre-differentiated into neural stem/progenitor cells, sorted with p75NTR, and used as a medium for differentiating into retinal nerve cells, the cells differentiated into Recoverin-positive cells with electrophysiological functions. In a different medium, H-iris iPS cells differentiated into retinal ganglion cell marker-positive cells with electrophysiological functions. This is the first demonstration of H-iris iPS cells differentiating into retinal neurons that function physiologically as neurons.


Assuntos
Fenômenos Eletrofisiológicos , Células-Tronco Pluripotentes Induzidas/fisiologia , Iris/citologia , Regeneração Nervosa/fisiologia , Neurônios Retinianos/fisiologia , Diferenciação Celular , Células Cultivadas , Reprogramação Celular , Corpos Embrioides/metabolismo , Células-Tronco Embrionárias/citologia , Humanos , Células-Tronco Pluripotentes Induzidas/citologia , Proteínas do Tecido Nervoso/metabolismo , Receptores de Fator de Crescimento Neural/metabolismo , Recoverina/metabolismo , Reprodutibilidade dos Testes , Células Ganglionares da Retina/metabolismo , Neurônios Retinianos/citologia , Teratoma/patologia
13.
Eur J Ophthalmol ; 31(4): 1817-1821, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32506951

RESUMO

INTRODUCTION: The ability to reduce illumination levels is generally accepted as one of the main benefits of a three-dimensional heads-up system (3D system: Ngenuity®; Alcon, CA, USA). Some studies have focused on illumination reduction in vitreoretinal procedures; however, information regarding illumination reduction in cataract surgery has not been published. PURPOSE: This study aimed to compare the illumination of the operational field with a 3D system and a standard microscope eyepiece during cataract surgery. SUBJECT AND METHODS: We retrospectively evaluated 91 eyes of 84 consecutive patients who were undergoing cataract surgery at our hospital. We used the 3D system and the eyepiece on alternative days. We determined the minimum light intensity required for safe surgery using the foot switch of the microscope (OMS800; Topcon, Tokyo, Japan). Illuminance on the ocular surface and the minimum illuminance required for the operation were calculated from the minimum light intensity. RESULTS: The 3D system was used in 45 eyes (3D group), and the eyepiece was used in 46 eyes (eyepiece group). The values of minimum illuminance in the 3D group were significantly lower than those in the eyepiece group (3D: 5500 ± 2000 lux, eyepiece: 11,900 ± 1800 lux; p < 0.001*). In addition, the illuminance of the operational field was reduced by 60.4% on average using the 3D system. CONCLUSION: With real-time digital processing and automated brightness control, the 3D system reduced ocular surface illumination by 50% or more. Hence, the 3D system may contribute to reducing the risk of retinal phototoxicity and patient photophobia.


Assuntos
Extração de Catarata , Catarata , Facoemulsificação , Humanos , Iluminação , Microscopia , Estudos Retrospectivos
14.
Exp Eye Res ; 202: 108299, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33068627

RESUMO

Some bipolar cells in the human retina are known to express voltage-gated Na+ channels. However, it is unclear which types of channels are expressed, and whether Na+ channel expression is limited to specific types of bipolar cells. In the present study, we examined the types of voltage-gated Na+ channels expressed in human bipolar cells and the morphology of bipolar cells with voltage-gated Na+ currents. To investigate the expression of voltage-gated Na+ channels in human bipolar cells, we examined whether Na+ channel transcripts could be detected in single bipolar cells using the reverse transcription polymerase chain reaction (RT-PCR) technique. The voltage-gated Na+ current was recorded from isolated bipolar cells using the patch-clamp recording technique. Types of bipolar cells that have the Na+ currents were investigated by analyzing their morphology after staining with Lucifer yellow. Using RT-PCR, the SCN2A Na+ channel was detected in 5 of 6 isolated bipolar cells. This suggests that a subset of human bipolar cells expresses the SCN2A Na+ channel. Under voltage-clamp conditions, depolarizing voltage steps induced a fast transient inward current in cone bipolar cells with axon terminal boutons that stratified at the ON layer, which includes the stratum 3, 4, and 5 of the inner plexiform layer (IPL, n = 2/11 cells). The fast transient inward current of isolated bipolar cells was blocked by 1 µM of tetrodotoxin (TTX), a voltage-gated Na+ channel blocker. No fast transient inward current was recorded with axon terminals that stratify at the OFF layer, which includes stratum 1 and 2 of the IPL (n = 4). Thus, a subset of ON cone bipolar cells at least expresses the putative voltage-gated Na+ channel SCN2A in the human retina. The Na+ channels in the bipolar cells may serve to amplify the release of neurotransmitter, glutamate, when membrane potential is rapidly depolarized and thereby selectively accelerating light responses.


Assuntos
Regulação da Expressão Gênica/fisiologia , Canal de Sódio Disparado por Voltagem NAV1.2/genética , Células Bipolares da Retina/metabolismo , Células Fotorreceptoras Retinianas Cones/metabolismo , Adulto , Idoso , Eletrofisiologia , Feminino , Humanos , Masculino , Potenciais da Membrana , Pessoa de Meia-Idade , Técnicas de Patch-Clamp , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Transdução de Sinais , Bloqueadores dos Canais de Sódio/farmacologia , Tetrodotoxina/farmacologia
15.
Doc Ophthalmol ; 142(2): 177-183, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32918674

RESUMO

PURPOSE: To investigate the effect of mild cataract and its surgery on the ISCEV standard electroretinogram (ERG) by comparing pre- and postoperative ERGs elicited from fully dilated eyes. METHODS: Twenty-two patients participated. Each eye had cataract of grade 2 according to Emery-Little classification. None had complications during and after phacoemulsification and intraocular lens implantation. According to the ISCEV standard, pre- and 1-week postoperative full-field ERGs, dark adapted (DA) 0.01, DA 3, DA 3 oscillatory potentials (OPs), DA 10, and light adapted (LA) 3, and LA 3 flicker, were elicited from fully dilated eyes using skin electrodes. Photopic negative response (PhNR) 1 amplitude was measured from the baseline to the trough before the i-wave in the LA 3 ERG waveform. Statistical analysis was performed using SigmaPlot version 11.0 (Systat Software, Inc., San Jose, CA, USA). Pre- and postoperative data were compared using a paired t-test. Non-normally distributed data were evaluated using the Wilcoxon signed rank test. RESULTS: The pre- and 1-week postoperative amplitudes in each component were as follows: DA 0.01: 48.4 ± 19.5 µV and 57.1 ± 20.0 µV (p = 0.002), a-wave of DA3: 51.5 ± 14.8 µV and 58.3 ± 17.3 µV (p = 0.003), b-wave of DA3: 88.3 ± 27.5 µV and 101.5 ± 29.7 µV (p = 0.003), DA 3 ΣOPs (sum of DA 3 OP1, OP2, and OP3 amplitude): 30.7 ± 16.3 µV and 37.1 ± 21.9 µV (p < 0.001), a-wave of DA 10: 65.5 ± 18.8 µV and 74.2 ± 19.5 µV (p < 0.001), b-wave of DA 10: 95.5 ± 29.6 µV and 111.1 ± 29.9 µV (p < 0.001), a-wave of LA 3: 7.2 ± 2.6 µV and 8.2 ± 2.2 µV (p = 0.025), b-wave of LA 3: 30.6 ± 12.9 µV and 35.3 ± 12.7 µV (p = 0.003), PhNR1: 5.8 ± 2.5 µV and 5.5 ± 2.6 µV (p = 0.562), and LA 3 flicker: 25.4 ± 8.9 µV and 27.8 ± 8.6 µV (p = 0.039), respectively. The implicit time of all the components did not reveal significant differences before and after surgery. CONCLUSIONS: Cataractous lens removal and intraocular lens implantation may influence ISCEV standard ERGs, even if the cataract is relatively mild.


Assuntos
Catarata , Midriáticos , Eletrorretinografia , Humanos , Estimulação Luminosa , Retina
16.
Fujita Med J ; 7(3): 105-109, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35111553

RESUMO

OBJECTIVES: We compared the effects of sub-Tenon's capsule anesthesia (STA) and trans-Tenon's capsule retrobulbar anesthesia (TTRBA) in 68 patients with epiretinal membrane. METHODS: Either STA or TTRBA was induced with 3 mL of lidocaine (2%) before vitrectomy combined with phacoemulsification and aspiration (phacovitrectomy). Akinesia was evaluated by range of eye movement (ROEM) in upward, downward, nasal, and temporal directions at 4, 10, and 30 minutes after injection. Analgesia was evaluated with a visual analogue pain score, which ranged from 0 to 10. RESULTS: The mean cumulative ROEMs were 1.44±1.02 corneal diameters (CDs) at 4 minutes, 0.55±0.76 CDs at 10 minutes, and 0.26±0.33 CDs at 30 minutes in patients who received STA; these values were 0.39±0.35 CDs at 4 minutes, 0.22±0.30 CDs at 10 minutes, and 0.13±0.29 CDs at 30 minutes in patients who received TTRBA. At both 4 and 10 minutes, the cumulative ROEMs in all directions, as well as the temporal ROEMs, were significantly larger in patients who received STA than in patients who received TTRBA. Pain scores did not significantly differ between groups at any time point. CONCLUSIONS: STA and TTRBA produced identical degrees of analgesia, but akinesia was slower in patients who received STA. TTRBA might be preferable for patients undergoing brief vitrectomy.

17.
Fujita Med J ; 7(4): 117-121, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35111555

RESUMO

OBJECTIVES: The aim of this study was to determine whether age correlates with amplitude and latency, when full-field electroretinography (ERG) is performed using skin electrodes. The ability of pulse reference power line noise reduction (PURE) to dampen the noise associated with the use of skin electrodes, was also investigated. METHODS: ERG was performed on 77 eyes in 77 healthy subjects (mean age: 55.6±19.0 years; age range: 9 to 86 years). Subjects with -5D or higher myopia, Emery-Little grade III or higher cataracts, retinal disease, uveitis, glaucoma, ≤5 mm mydriasis, or a history of intraocular surgery other than cataract surgery, were excluded. The active, reference, and ground electrodes were placed on the lower eyelid, outer canthus, and earlobe, respectively. Responses were averaged 10 times for dark-adapted (DA) ERGs, and 32 to 64 times for light-adapted (LA) ERGs. Noise was removed using the PURE method. RESULTS: The DA ERGs without PURE were so noisy that the amplitude or latency could not be determined, whereas those with PURE were comparatively quieter. ERG with PURE demonstrated a significant negative correlation between age and amplitude and a significant positive correlation between age and latency. CONCLUSIONS: We could record the measurable ERG waveforms with skin electrodes by using the PURE method, especially in fewer averaged conditions. It is suggested that skin electrode with PURE is suitable to examine the pathological ERGs, and other types of electrodes. It is recommended that the aging effect should be taken into consideration when pathological ERGs are evaluated.

18.
Eur J Ophthalmol ; 31(6): 2977-2980, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33238716

RESUMO

PURPOSE: We report a novel technique for visualizing the posterior surface of the lens nucleus during phacoemulsification. SURGICAL TECHNIQUE: Hydro-dissection was performed using a solution of 20 mg triamcinolone acetonide powder without preservatives mixed with 3 ml BSS-plus, and triamcinolone acetonide was clearly identifiable underneath the posterior surface of the lens nucleus. Using a phaco-tip, the nucleus was shaved to the level of the triamcinolone acetonide and could be easily divided. The remnant triamcinolone acetonide was aspirated as much as possible from the lens cortex with an infusion/aspiration tip. SUBJECTS AND EVALUATION TECHNIQUE: Twenty-eight eyes in 28 patients with cataracts were enrolled in this study. Triamcinolone acetonide-assisted phacoemulsification was performed in 13 eyes in 13 patients (triamcinolone acetonide-phacoemulsification group), and normal phacoemulsification was performed in 15 eyes in 15 patients (phacoemulsification group). Intraocular pressure was measured in all patients pre-operatively, 1 day after, and 1 week after surgery. Corneal endothelial cell density was measured pre-operatively and 1 month after surgery. The time of surgical phacoemulsification (surgical phaco time) was measured from the video of the surgery. RESULTS: Surgery was successively performed in all eyes. Pre-operative and post-operative intraocular pressures and cell densities did not significantly differ between the two groups. Surgical phaco time was shorter in the triamcinolone acetonide-phacoemulsification group than in the phacoemulsification group (157.1 ± 51.7 s vs 225.3 ± 45.1 s; p = 0.006). CONCLUSION: The triamcinolone acetonide-assisted phacoemulsification procedure is safe and useful for visualizing the posterior surface of the lens nucleus and facilitates removal of the lens nucleus by phacoemulsification.


Assuntos
Catarata , Facoemulsificação , Glucocorticoides , Humanos , Núcleo do Cristalino/cirurgia , Triancinolona Acetonida , Acuidade Visual
19.
Doc Ophthalmol ; 142(1): 127-132, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32588162

RESUMO

PURPOSE: This study reports a case of unilateral retinopathy with extinguished full-field ERGs (ffERGs), wherein the visual acuity was 16/16 and the visual field was spared. METHODS: Observational case report. RESULTS: A 39-year-old female had developed nyctalopia in her left eye. Two years later, she visited an ophthalmologist who noted a bilaterally reduced pigmentation of the fundus. Her best-corrected visual acuity was 16/16 in both the eyes. Goldmann perimetry demonstrated that her visual field was bilaterally fully spared. ffERGs measurement was performed in accordance with the ISCEV standard protocol and indicated that her right eye was normal. However, all ERG responses were severely attenuated in her left eye. Multifocal ERG responses were found to be normal in the right eye and extinguished in the left eye except for residual responses that were exclusively located at the center. During the 7 years of the follow-up period, the visual field in the left eye, which was once normal, became shaded, and the development of a ring scotoma was identified. The visual field in the right eye is still full. CONCLUSIONS: The pathogenesis of this patient's condition still remains unknown, while unilateral retinitis pigmentosa, unilateral pigmentary retinopathy, acute zonal occult outer retinopathy, and autoimmune retinopathy can all be considered as possible explanations. The uniqueness of this case study is that the extinguished ERG responses are predictive of the functional alteration in the affected eye, when the initial visual acuity and the visual field were normal.


Assuntos
Doenças Autoimunes , Doenças Retinianas , Adulto , Eletrorretinografia , Feminino , Humanos , Acuidade Visual , Campos Visuais
20.
Jpn J Ophthalmol ; 64(2): 210-215, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31907691

RESUMO

PURPOSE: We present a novel technique for measuring volume of space replaced by air during fluid-air exchange in vitrectomy (vitrectomized space) for intravitreal gas injection. To confirm the feasibility of this technique, we assessed postoperative intraocular pressure (IOP) and the duration of injected gas. Using this technique, we found remarkable differences in volume between high myopic eyes with retinal detachment caused by peripheral break (PB-RD group) and those with macular hole retinal detachment (MH-RD group). We studied the relationships between the volume and biometric values, axial length (AL) and corneal curvature radius (CCR) in both PB-RD and MH-RD group. STUDY DESIGN: Retrospective study. METHODS: During fluid-air exchange, the aspirated fluid accumulates in the measuring cup between the infusion needle and vitrectomy instrument. Vitrectomized space volume is obtained by subtracting the volume of the tube between the infusion needle and the 3-way stopcock from the aspirated fluid volume. We performed phaco-vitrectomies by measuring the vitrectomized space volume and then injected pure SF6 at 15% of the volume into the vitreous cavity in 156 myopic eyes (AL > 26 mm) with RD consisting of 144 eyes in PB-RD group and 12 in MH-group. RESULTS: The IOP (mean ± SD) was 13.5 ± 3.4 mmHg preoperatively, 23.4 ± 10.4 mmHg on day 1, 18.2 ± 7.4 mmHg on day 2, and 16.1 ± 4.5 on day 7. The gas disappeared in 16.1 ± 1.9 days. Axial length was longer in the MH-RD group but the volume of vitrectomized space was larger in the PB-RD group. AL and volume were significantly correlated in both groups (P < 0.01), but the fitting lines differed. The CCR and volume significantly correlated in the PB-RD group (P < 0.01) but not in the MH-RD group. CONCLUSION: Our novel technique for measuring the volume of vitrectomized space can achieve target gas concentration in the vitreous cavity. The difference in the shape of eyeballs may explain discrepancies in relationship between volume and the biometric factors.


Assuntos
Tamponamento Interno/métodos , Miopia Degenerativa/complicações , Retina/patologia , Descolamento Retiniano/cirurgia , Acuidade Visual , Vitrectomia/métodos , Idoso , Feminino , Humanos , Pressão Intraocular , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Descolamento Retiniano/complicações , Descolamento Retiniano/diagnóstico , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA