1.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37748089

RESUMO

AIMS: Left bundle branch area pacing (LBBAP) is a potential alternative to His bundle pacing. This study aimed to investigate the impact of different septal locations of pacing leads on the diversity of QRS morphology during non-selective LBBAP. METHODS AND RESULTS: Non-selective LBBAP and left ventricular septal pacing (LVSP) were achieved in 50 and 21 patients with atrioventricular block, respectively. The electrophysiological properties of LBBAP and their relationship with the lead location were investigated. QRS morphology and axis showed broad variations during LBBAP. Echocardiography demonstrated a widespread distribution of LBBAP leads in the septum. During non-selective LBBAP, the qR-wave in lead V1 indicated that the primary location for pacing lead was the inferior septum (93%). The non-selective LBBAP lead was deployed deeper than the LVSP lead in the inferior septum. The Qr-wave in lead V1 with the inferior axis in aVF suggested pacing lead placement in the anterior septum. The penetration depth of the non-selective LBBAP lead in the anterior septum was significantly shallower than that in the inferior septum (72 ± 11 and 87 ± 8%, respectively). In lead V6, the deep S-wave indicated the time lag between the R-wave peak and the latest ventricular activation in the coronary sinus trunk, with pacemaker leads deployed closer to the left ventricular apex. CONCLUSION: Different QRS morphologies and axes were linked to the location of the non-selective LBBAP lead in the septum. Various lead deployments are feasible for LBBAP, allowing diversity in the conduction system capture in patients with atrioventricular block.


Assuntos
Bloqueio Atrioventricular , Septo Interventricular , Humanos , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Septo Interventricular/diagnóstico por imagem , Sistema de Condução Cardíaco , Ventrículos do Coração/diagnóstico por imagem , Doença do Sistema de Condução Cardíaco
2.
J Cardiovasc Electrophysiol ; 33(8): 1791-1800, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35748391

RESUMO

INTRODUCTION: Multisurface pacemapping may help identify the surface of interest in scar-related ventricular tachycardia (VT). This study aimed to investigate the performance of pacemap parameters for detecting critical sites through multisurface mapping. METHODS AND RESULTS: In 26 patients who underwent scar-related VT ablation, pacemap parameters including a matching score, the difference between the longest and shortest stimulus-QRS intervals (Δs-QRS), and the distance between the good pacemap sites were measured. The parameters were compared between surfaces with and without critical sites and ablation outcomes. A total of 941 pacemap at 56 surfaces targeting 35 VTs were analyzed. A greater Δs-QRS (40 vs. 8 ms, p < .001) and longer distance between two good pacemap sites (24 vs. 13 mm, p < .001) were observed on the surfaces with critical sites. A similar trend was seen in multisurface pacemapping for the same VTs (52 vs. 18 ms in Δs-QRS, p = .021; 37 vs. 12 mm in distance, p = .019), although the best pacemap scores were comparable (94 vs. 87, p = .295). The Δs-QRS > 20 ms and the distance >19 mm showed high positive likelihood ratios (19.8 and 6.1, respectively) for discriminating the surface harboring the critical site. Ablation of VTs fulfilling these parameters was successful on the surfaces, but without the required multisurface ablation. CONCLUSION: Temporal (Δs-QRS) and spatial (distance) parameters for good pacemap match sites were excellent markers for detecting the surface harboring critical sites in scar-related VT. A multisurface pacemapping can successfully identify the surface of interest.


Assuntos
Ablação por Cateter , Infarto do Miocárdio , Taquicardia Ventricular , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cicatriz/diagnóstico , Cicatriz/patologia , Cicatriz/cirurgia , Eletrocardiografia , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
3.
J Cardiovasc Electrophysiol ; 33(6): 1255-1261, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35304791

RESUMO

INTRODUCTION: Few predictors of low capture threshold before the deployment of the Micra transcatheter pacing system (Micra TPS) have been determined. We aimed to identify fluoroscopic predictors of an acceptable capture threshold before Micra TPS deployment. METHODS: Sixty patients were successfully implanted with Micra TPS. Before deployment, gooseneck appearance of the catheter shaft was quantified using the angle between the tangent line of the shaft and the cup during diastole in the right anterior oblique (RAO) view. The direction of the device cup toward the ventricular septum was evaluated using the angle between the cup and the horizontal plane in the left anterior oblique (LAO) view. RESULTS: Of the 95 deployments we evaluated, 56 achieved an acceptable capture threshold of ≤2.0 V at 0.24 ms. In this acceptable threshold group, the deflection angle of the gooseneck shaft was significantly larger and the device cup was placed more horizontally with a lower elevation angle compared with those in the high threshold group. A deflection angle of ≥6° and an elevation angle of ≤30° were identified as the predictors of an acceptable capture threshold after deployment. An acceptable capture threshold was achieved in 24/31 (77.4%) patients in whom either angle criterion was satisfied at the first deployment. CONCLUSIONS: Diastolic gooseneck appearance of the delivery catheter in the RAO view or near-horizontal direction in the LAO view predicts an acceptable capture threshold after deployment. The shape of the delivery catheter before deployment should be evaluated using multiple fluoroscopic views to ensure successful implantation of Micra TPS.


Assuntos
Marca-Passo Artificial , Desenho de Equipamento , Fluoroscopia , Humanos , Resultado do Tratamento
4.
Eur Heart J Digit Health ; 3(3): 455-464, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36712156

RESUMO

Aims: Detection of asymptomatic paroxysmal atrial fibrillation is challenging. Smartphone- or smartwatch-based photoplethysmography is efficient at detecting irregular rhythms using pulse waves but is too complex for older patients. We aimed to evaluate the detection accuracy of atrial fibrillation by a wristwatch-type continuous pulse wave monitor (PWM) in daily life. Methods and results: Patients at high risk of atrial fibrillation but with no history of atrial fibrillation (n = 163; mean CHADS2 score, 1.9) and patients with known atrial fibrillation (n = 123, including 34 with persistent atrial fibrillation) underwent PWM and telemetry electrocardiogram recording for 3 days. Risk of atrial fibrillation was judged using the 'Kyorin Atrial Fibrillation Risk Score', a scoring system based on previously reported atrial fibrillation risk scoring systems. The PWM assessed the presence of atrial fibrillation at 30 min intervals, and the results were compared with the telemetry electrocardiogram findings. The PWMs accurately diagnosed two patients with paroxysmal atrial fibrillation in the high-risk group. The PWMs accurately diagnosed 48 of the 55 patients with atrial fibrillation in the known-atrial fibrillation group. The PWM accuracy in detecting patients with atrial fibrillation was as follows: sensitivity, 98.0%; specificity, 90.6%; positive predictive value, 69.4%; negative predictive value, 99.5%. The respective values for intervals with atrial fibrillation were 86.9%, 98.8%, 89.6%, and 98.5%. Conclusion: The wristwatch-type PWM has shown feasibility in detecting atrial fibrillation in daily life and showed the possibility of being used as a screening tool.

5.
Int Heart J ; 62(5): 1005-1011, 2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-34544979

RESUMO

Esophageal injury is a rare but serious complication of atrial fibrillation (AF) ablation. To minimize esophageal injury, our persistent AF (PerAF) protocol involves complete left atrial posterior wall (LAPW) and pulmonary vein (PV) isolation (box isolation), with a centerline away from the esophagus. However, there has been a concern that extensive LA isolation might deteriorate LA function. There has been a paucity of data on LA remodeling after box isolation. Therefore, we compared LA size pre- and post-box isolation with an LAPW centerline in patients with PerAF.Patients who underwent catheter ablation (CA) for PerAF between November 2016 and December 2018 were retrospectively evaluated.The LAPW, including all PVs, was completely isolated in 105 consecutive patients (75 men; mean age: 68 ± 10 years) with PerAF, including 58 patients with long-standing PerAF. During a follow-up of 660 ± 332 days, 76 patients (72%) were arrhythmia-free. The LA dimension (38 ± 6 mm versus 42 ± 7 mm; P < 0.0001) and volume index (38 ± 13 mL/m2 versus 47 ± 14 mL/m2; P < 0.0001) at 6 months post-ablation were significantly decreased in patients who maintained sinus rhythm compared to pre-ablation. In patients with recurrent AF/atrial tachycardia (AT), these parameters were also significantly decreased (P < 0.001, respectively).Box isolation with a posterior centerline has no esophageal complications and a high clinical success rate in patients with PerAF. Reverse remodeling could be achieved even when using extensive isolation of the PV and LAPW in patients with PerAF.


Assuntos
Fibrilação Atrial/cirurgia , Remodelamento Atrial/fisiologia , Ablação por Cateter/efeitos adversos , Doenças do Esôfago/etiologia , Esôfago/lesões , Átrios do Coração/fisiopatologia , Idoso , Fibrilação Atrial/diagnóstico , Técnicas de Imagem Cardíaca/instrumentação , Ablação por Cateter/estatística & dados numéricos , Ablação por Cateter/tendências , Cateteres Venosos Centrais/efeitos adversos , Ecocardiografia/métodos , Eletrocardiografia/métodos , Doenças do Esôfago/prevenção & controle , Esôfago/diagnóstico por imagem , Feminino , Fluoroscopia/métodos , Seguimentos , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
6.
JACC Clin Electrophysiol ; 7(10): 1297-1308, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34217659

RESUMO

OBJECTIVES: This study investigates the effect of stellate ganglion (SG) phototherapy in healthy participants and assesses its efficacy in suppressing electrical storm (ES) refractory to antiarrhythmic drugs and catheter ablation. BACKGROUND: Modulation of the autonomic nervous system has been shown to be an effective adjunctive therapy for ES. METHODS: Ten-minute SG phototherapy was performed twice weekly for 4 weeks in 20 healthy volunteers. To evaluate the acute and chronic effects of SG phototherapy, heart rate variability and serum concentrations of adrenaline, noradrenaline, and dopamine were obtained before phototherapy, immediately after the first phototherapy session, after 8 sessions of phototherapy, and 3 months after the first phototherapy session. In addition, the efficacy of SG phototherapy was evaluated in 11 patients with ES refractory to medication, sedation, and catheter ablation. RESULTS: In healthy participants, serum adrenaline concentration significantly decreased after phototherapy, whereas low-frequency power/high-frequency power significantly decreased during phototherapy. Moreover, the effect on heart rate variability did not last beyond 3 months. In the clinical pilot study, 7 patients had a suppression of ES after SG phototherapy; however, without maintenance therapy, 2 patients had a recurrence of ventricular arrhythmias. Furthermore, it did not control ES in 4 patients. CONCLUSIONS: SG phototherapy reduced sympathetic activity and may be a safe and effective adjunctive therapy to control ES in some patients, but its long-term efficacy remains unknown. Chronic phototherapy might help reduce ES recurrence.


Assuntos
Gânglio Estrelado , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Lasers , Fototerapia , Projetos Piloto
7.
JACC Clin Electrophysiol ; 7(4): 513-521, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33358668

RESUMO

OBJECTIVES: This study investigated the differences between distal His bundle pacing (HBP) via the right ventricle and proximal HBP via the right atrium with regard to pacing and sensing parameters. BACKGROUND: HBP preserves physiological ventricular activation. The capture threshold of the adjacent ventricle accompanying HBP has not been evaluated after implantation. METHODS: Fifty patients with bradycardia (58% with atrioventricular block) underwent successful HBP and were followed for 1 year. Precise locations of the lead tips were confirmed using follow-up echocardiography. RESULTS: HBP leads were fixed via the right atrium or right ventricle (25 patients each). Overall, the local ventricle and HBP thresholds were elevated during follow-up. The distal HBP thresholds did not significantly differ from the proximal HBP thresholds, although local ventricular thresholds of distal HBP were markedly lower than those of proximal HBP. At 6 months, the accepted ventricular threshold (≤2.5 V) was maintained in 39 patients (78%). An amplitude of ventricular electrogram post-fixation of ≥2.0 mV and a capture threshold of ≤1.1 V at implantation were determined to be optimal values for predicting the accepted threshold at 6 months, with areas under the curve of 0.86 and 0.84, respectively. Atrial oversensing was often detected in proximal HBP but not distal HBP. CONCLUSIONS: Distal HBP via the right ventricle captured the His bundle, similar to proximal HBP via the right atrium, with a superior local ventricular threshold during follow-up. Anatomy and electrophysiological ventricular properties at implantation may be critical for maintaining adjacent ventricle capture to prevent lead revision (Evaluation of Electrophysiological Parameters related to His Bundle Pacing in Patients With Bradyarrhythmias; UMIN000031364).


Assuntos
Fascículo Atrioventricular , Ventrículos do Coração , Estimulação Cardíaca Artificial/efeitos adversos , Eletrocardiografia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Resultado do Tratamento
9.
Heart Rhythm O2 ; 1(4): 268-274, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34113880

RESUMO

BACKGROUND: The incidence of pericardial effusion (PE) during radiofrequency catheter ablation (CA) for atrial fibrillation is approximately 1%. PE is a major complication during CA, but there has been limited literature about the perforation site responsible. OBJECTIVE: This study aimed to retrospectively investigate the characteristics of the procedure and the patients in whom PE developed during CA. METHODS: Of 1363 consecutive patients who underwent catheter ablation from January 2015 to June 2019 in Kyorin University Hospital, we reviewed patients who developed PE during CA. RESULTS: PE during CA occurred in 18 (1.32%) patients (median age, 71 [interquartile range (IQR) 65-77] years, 7 women). The median body mass index was 24 (IQR 20-27). Target arrhythmias for CA of patients with PE include atrial fibrillation (AF) (n = 13, 72%), premature ventricular contraction (n = 2, 11%), ventricular tachycardia (n = 1, 6%), atrial flutter (n = 1, 6%), and orthodromic reciprocating tachycardia (n = 1, 6%). Seventeen patients required pericardiocentesis, resulting in 300 (IQR 192.5-475) mL of drainage. Two patients required emergency surgical repair, and 1 died from aortic dissection. Based on the gas analysis, the drained blood was of venous origin in 47% of the total events and 54% of AF ablation. CONCLUSION: PE caused by a diagnostic catheter in the right heart is not uncommon, even in AF ablation.

10.
Open Heart ; 6(1): e000982, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31297225

RESUMO

Objective: Recently, concern has increased regarding the hazards of radiation exposure in patients and laboratory staff. Since the numbers of complex catheter ablations (CA) performed, duration of procedure times, and need for multiple sessions have increased, radiation exposure during each session needs to be minimised. Our study aimed to assess the impact of awareness on radiation exposure during CA for atrial fibrillation (AF). Methods: Mini-course lectures was delivered to the physicians and staff in the electrophysiology division. Its effect on the fluoroscopic time and radiation dose during AF ablation before (Group I, n=70), shortly after (Group II: n=70) and remotely after the mini-lecture (Group III, n=70) were evaluated. Patient demographics, preoperative testing and procedural parameters were collected. Results: The fluoroscopic time significantly reduced after the lecture (Group I and II: 25.1±10.0 and 15.1±7.3 min, respectively (p<0.0001)), and remained so in Group III (13.0±5.4 min), despite the increase in the number of persistent AFs. The radiation dose also significantly reduced (Groups I, II, III: 295.0±263.0, 109.6±103.5 and 110.1±89.6 mGy, respectively (p<0.0001)). Conclusion: Awareness on radiation exposure led to a significant reduction in fluoroscopic time and radiation dose during CA for AF, the effect of which persisted even to remote periods following the procedure.

11.
Circ Arrhythm Electrophysiol ; 12(6): e007415, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31113233

RESUMO

Background His-bundle pacing (HBP) is a physiological form of pacing. Although high capture thresholds are common, few predictors of low HBP threshold have been determined. We aimed to identify electrophysiological predictors. Methods Fifty-one patients (53% with atrioventricular block) underwent HBP for bradycardia with an intrinsic QRS duration of <120 ms. Attempts to anchor the HBP lead were guided by unipolar His-bundle electrograms (HB EGMs) recorded with an electrophysiology recording system. Patients were followed-up for >6 months. Results In total, 153 attempts at anchoring the HBP lead were made, of which, 45 achieved acceptable HBP thresholds (≤2.5 V at 1 ms). The amplitude of negative deflection in HB EGM and the selective HBP form at fixation were independently associated with achieving an acceptable threshold. A negative amplitude of ≥0.060 mV in HB EGM was determined as the optimal value for identifying the acceptable threshold. This deep negative HB EGM was recorded with an HBP threshold of 1.4±1.3 V (in 34 attempts), significantly lower than that of positive HB EGM without deep negative deflection (2.8±1.3 V, in 31 trials; or >5 V, in 38 trials). The permanent HBP lead remained with deep negative (≥0.060 mV) or positive HB EGMs in 28 and 14 patients, respectively, and with positive or negative HB injury current in 19 and 23 patients, respectively. During follow-up, increased HBP threshold of >1 V was significantly more prevalent in the positive HB EGM group. The HBP thresholds of deep negative HB EGM and HB injury current, but not of the selective HBP group, were significantly lower than the other subgroups during follow-up. Conclusions Deep negative HB EGM at fixation was associated with an excellent short-term HBP threshold, similar to HB injury current. Analysis of unipolar HB EGM postfixation may enable prediction of permanent HBP threshold.


Assuntos
Potenciais de Ação , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Bradicardia/diagnóstico , Fascículo Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Idoso , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/fisiopatologia , Bradicardia/fisiopatologia , Bradicardia/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
Int Heart J ; 60(1): 78-85, 2019 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-30464135

RESUMO

A novel, sensor-based, electromagnetic, non-fluoroscopic catheter visualization (NFCV) system shows tracked catheters directly on pre-acquired fluoroscopy or cine loops. We aimed to evaluate the effectiveness of this system in the setting of catheter ablation for idiopathic premature ventricular contractions/ventricular tachycardia (i-PVC/VT).A total of 30 i-PVC/VT ablation procedures were performed using the NFCV system in conjunction with three-dimensional electroanatomic mapping system (3D-EMS) between January 2013 and April 2017. At the beginning of the procedure, cine loops of right and left anterior oblique views were obtained and replayed for subsequent mapping and ablation. Right ventriculography, aortography, or coronary angiography was performed, depending on the chamber of interest. We reviewed procedural parameters, comparing with the i-PVC/VT ablation procedure using conventional fluoroscopy (CvF) system (pre-, and post-NFCV implementation; 20 and 11 cases, respectively).I-PVC/VTs were successfully eliminated in 26 patients (87%) in the NFCV group and in 26 (84%) in the CvF group (P = 1.000). The procedure time in the NFCV group was comparable to that in the CvF group (119.8 versus 125.0 minutes, respectively, P = 0.868); the total fluoroscopy time was significantly shorter in the NFCV group (3.3 versus 16.6 minutes, P < 0.001). One patient in the CvF group experienced cardiac tamponade, requiring pericardial drainage. No major complications were encountered in the NFCV group.NFCV system, in conjunction with 3D-EMS, was safe and feasible for i-PVC/VT mapping and ablation. The system contributed to dramatically reduced fluoroscopy time, compared with CvF.


Assuntos
Ablação por Cateter/métodos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/diagnóstico por imagem , Complexos Ventriculares Prematuros/cirurgia , Adulto , Aortografia , Angiografia Coronária , Fenômenos Eletromagnéticos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
13.
J Arrhythm ; 34(3): 326-328, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29951156

RESUMO

A subclinical cardiac perforation by a device cup of the Micra™ transcatheter pacing system was suspected in a 78-year-old woman. During the procedure, the device cup was placed on the septum. The contrast media was injected before device deployment and remained outside of the myocardium. Later, a cardiac computed tomography scan visualized a protruded diverticular structure on the right ventricle. The contrast material remained in a pouch within the pericardium. To ensure the device is oriented away from the border between the right ventricular septum and the free wall, right anterior oblique view should be carefully reviewed before deployment.

14.
J Arrhythm ; 33(4): 318-323, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28765763

RESUMO

BACKGROUND: When performing catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT), it can be difficult to maintain a safe distance from the His recording site to avoid AV block in patients with a short distance between this recording site to the coronary sinus (CS) ostium (small triangle of Koch [TOK]). In this study, we sought to identify parameters predicting small TOK and test these parameters in patients undergoing AVNRT catheter ablation. METHODS: Twenty-eight patients who underwent catheter ablation of atrial fibrillation using a three-dimensional (3D) electroanatomical mapping system (EAM) with computed tomography (CT) merge (23 males; mean age, 65.8±12.1 years) were included. The shortest distance between the CS ostium and His recording sites (His-CSd) was measured on the EAM. Aortic (Ao) unfolding in chest X-ray scan, Ao angle to the LV, Ao length, Ao to the right ventricular distance, size of the Valsalva in the CT scan, and parameters of echocardiogram were evaluated. The identified parameters were subsequently tested as predictors for small TOK in patients undergoing AVNRT ablation. RESULTS: The size of TOK was associated with Ao length (r = -0.70, p<0.01), left ventricular end-systolic dimension (LVDs) (r = -0.51, p<0.01), and Ao unfolding. In patients with AVNRT, only Ao unfolding predicted a smaller TOK. CONCLUSIONS: Small TOK was associated with longer Ao, larger LVDs, and Ao unfolding. Of these, Ao unfolding was associated with smaller TOK in patients with AVNRT.

15.
J Arrhythm ; 32(2): 89-94, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27092188

RESUMO

BACKGROUND: There are no criteria for selecting single- or dual-chamber implantable cardioverter defibrillators (ICDs) in patients without a pacing indication. Recent reports showed no benefit of the dual-chamber system despite its preference in the United States. As data on ICD selection and respective outcomes in Japanese patients are scarce, we investigated trends regarding single- and dual-chamber ICD usage in Japan. METHODS: Data from a total of 205 ICD recipients with structural heart disease (median age, 63 years) in two Japanese university hospitals were reviewed. Patients with bradycardia with a pacing indication and permanent atrial fibrillation at implantation were excluded. RESULTS: Single- and dual-chamber ICDs were implanted in 36 (18%) and 169 (82%) patients, respectively. Non-ischemic cardiomyopathy dominated both groups. Seventeen dual-chamber patients developed atrial pacing-dependency over 4.5 years, and it developed immediately after implantation in 14. Although preoperative testing showed no sign of bradycardia in these patients, their pacing rate was set higher than it was in patients who were pacing-independent (61 vs. 46 paces per min, p<0.01). Two single-chamber patients (5%) underwent atrial lead insertion. While inappropriate shock equally occurred in both groups (7 vs. 21 patients, single- vs. dual-chamber, P=0.285), device-related infection occurred only in dual-chamber patients (0 vs. 9 patients, P=0.155). No differences in death or heart failure hospitalization were observed between groups. CONCLUSIONS: Dual-chamber ICDs were four-fold more common in Japanese patients without a pacing indication. No benefit over single-chamber ICD was observed. Newly developed atrial pacing-dependency seemed to be limited and could have been overestimated due to higher pacing rate settings in dual-chamber patients.

17.
Circ J ; 77(2): 432-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23059771

RESUMO

BACKGROUND: T-wave alternans based on the modified moving average method (MMA-TWA) and heart rate turbulence (HRT) have been introduced as predictors for cardiac mortality. In this study, we simultaneously recorded MMA-TWA and HRT in patients after myocardial infarction (MI) and designed a prospective observational study. METHODS AND RESULTS: We prospectively enrolled 313 consecutive post-MI patients (age 70 ± 12 years, 232 men). The MMA-TWA and HRT were simultaneously measured using algorithms based on 24-h Holter ECG monitoring during daily activity. MMA-TWA was determined positive when the maximal voltage was >64 µV, and HRT was determined positive when both turbulence onset and turbulence slope were abnormal. The endpoint was defined as overall cardiac mortality and fatal arrhythmic events. MMA-TWA was positive in 14 patients (4.4%) and HRT was positive in 61 patients (19.5%). During follow-up of 1,190 ± 441 days, 28 patients (9%) reached the endpoint, including 12 patients with fatal arrhythmic events. Both MMA-TWA and HRT were significant predictors for the endpoint. On multivariate analysis, HRT had the most significant value, with a hazard ratio (HR) of 5.7 (P=0.0008). When focused on fatal arrhythmic events including sudden cardiac death, MMA-TWA had the most significant value (HR 5.8, P=0.0072). CONCLUSIONS: The present study revealed that both MMA-TWA and HRT were significant predictors. MMA-TWA is more associated with arrhythmic events than cardiac mortality in post-MI patients.


Assuntos
Morte Súbita Cardíaca/epidemiologia , Eletrocardiografia Ambulatorial , Frequência Cardíaca/fisiologia , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Comorbidade , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Fatores de Risco
19.
Ann Noninvasive Electrocardiol ; 17(3): 260-7, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22816545

RESUMO

BACKGROUND: Previous studies have described the clinical usefulness of the presence of nonsustained ventricular tachycardia (NSVT) and defined heart rate turbulence (HRT) in stratifying patients at risk. We prospectively assessed whether HRT can facilitate the predictive accuracy of NSVT for identifying patients at risk for serious arrhythmic events in patients with left ventricular (LV) dysfunction. METHODS: We enrolled 299 consecutive patients with LV dysfunction (ejection fraction ≤ 40%) including ischemic (n = 184) and nonischemic causes (n = 115). The presence of NSVT was assessed on Holter electrocardiograms (ECGs). HRT was simultaneously measured from Holter ECGs, assessing two parameters: turbulence onset (TO) and turbulence slope (TS). HRT was considered positive when both TO and TS were abnormal. The end point was defined as of sudden cardiac death (SCD) and sustained ventricular tachyarrhythmias (VTs). RESULTS: NSVT was documented in 93 patients (32.7%). For HRT assessment, 17 patients (5.6%) were not utilized. Of 282 patients, 68 (24.1%) were HRT positive. During follow-up of 960 ± 444 days, 14 patients (5.0%) reached the end point. NSVT, HRT, and diabetes were significantly associated with the end point. On multivariate analysis, NSVT had the strongest value for the end point, with an HR of 4.4 (95%CI, 1.4-14.3; P = 0.0138). When NSVT combined with HRT, the predictive accuracy is more increased, with an HR of 8.2 (95%CI, 2.9-23.3; P < 0.0001). The predictive values of the combination were higher than single use of NSVT or HRT. CONCLUSIONS: HRT can facilitate the predictive accuracy of NSVT for identifying patients at risk for serious arrhythmic events in patients with LV dysfunction.


Assuntos
Arritmias Cardíacas/diagnóstico , Eletrocardiografia Ambulatorial , Taquicardia Ventricular/diagnóstico , Disfunção Ventricular Esquerda/complicações , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Estudos de Coortes , Intervalos de Confiança , Morte Súbita Cardíaca , Feminino , Frequência Cardíaca/fisiologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Medição de Risco , Análise de Sobrevida , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/mortalidade , Fatores de Tempo , Disfunção Ventricular Esquerda/diagnóstico
20.
Int Heart J ; 53(2): 113-6, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22688315

RESUMO

Pacing from the right ventricular (RV) apex is associated with adverse effects such as heart failure and atrial fibrillation. We attempted pacing from the RV mid-septum, which is theoretically a more physiological pacing site. A total of 172 consecutive patients with indications for permanent pacemaker implantation were studied. A screw-in lead and a curved stylet were used for lead positioning on the RV mid-septum. Pacemaker indices were evaluated at implantation and one year later. As an electrocardiographic parameter, QRS duration was measured in lead II. These data were compared to those of 66 patients subjected to conventional RV apical pacing. Lead placement was successful in all patients of RV mid-septal pacing. There were no technical problems during or after the procedure. The cumulative percentage of ventricular pacing at one year postimplantation was 85 ± 24 % in the SSP group. Sensing, pacing threshold, and lead impedance in the SSP group remained clinically stable over one year. When these measurements were compared between the SSP and AP groups, the pacing threshold and the lead impedance at one year postimplantation in the SSP group were higher (P < 0.05) and lower (P < 0.01), respectively, than those of the AP group. The mean QRS duration was markedly shorter (123 ± 16 versus 150 ± 18 msec, P < 0.0001). Selective site pacing from the RV mid-septum is feasible and results in less conduction delay compared to conventional RV apical pacing, and its procedure seems to be more physiological in permanent pacemaker implantation.


Assuntos
Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial , Síndrome do Nó Sinusal/terapia , Idoso , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial/efeitos adversos , Eletrocardiografia , Feminino , Seguimentos , Ventrículos do Coração , Humanos , Masculino , Resultado do Tratamento , Septo Interventricular