1.
Europace ; 26(9)2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39228338

RESUMO

AIMS: Previous clinical studies on pulmonary vein isolation (PVI) with a radiofrequency balloon (RFB) reported safe and effective procedures using conventional ablation settings with 20/60 s RF delivery via posterior/anterior (PST/ANT) electrodes. The latest evidence suggests that reducing the application time to 15 s (s) on the posterior wall when facing the oesophageal region is as effective as applying 20 s. To prospectively assess whether reducing RF time on PST/ANT segments to 15/45 s can ensure sufficient quality of lesion metrics and compare the new shortened ablation settings with the conventional one in terms of safety, and effectiveness at 1-year. METHODS AND RESULTS: A total of 641 patients from seven European centres were enrolled in a collaborative registry, with 374 in the conventional RF delivery group and 267 in the shortened RF delivery group. Procedural outcomes, lesion metrics, and safety profiles were assessed and compared between the groups. Freedom of any atrial tachycarrythmias at one year was 85.4% and 88.2% in the SHRT and CONV groups, respectively. The shortened RF delivery strategy was associated with significantly shorter procedure times (median 63.5 vs. 96.5 min, P < 0.001) and shortened fluoroscopy exposure (median 10.0 vs. 14.0 min, P < 0.001) compared to conventional delivery. Efficacy metrics, including first-pass isolation rates and time to isolation, were comparable between groups. Shortened RF delivery was associated with a lower incidence of procedural complications (1.4% vs. 5.3%, P = 0.04) and optimized thermal characteristics. CONCLUSION: Analyses from the COLLABORATE registry demonstrate that shortening RF energy delivery times to 15/45 s (PST/ANT) during PVI with the RFB resulted in comparable freedom from recurrent atrial tachyarrhythmia compared to conventional delivery times with comparable efficiency and safety.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Sistema de Registros , Humanos , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Feminino , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Resultado do Tratamento , Idoso , Europa (Continente) , Fatores de Tempo , Estudos Prospectivos , Cateteres Cardíacos , Recidiva , Fatores de Risco
2.
Sensors (Basel) ; 24(7)2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38610349

RESUMO

Seismocardiography (SCG), a method for measuring heart-induced chest vibrations, is gaining attention as a non-invasive, accessible, and cost-effective approach for cardiac pathologies, diagnosis, and monitoring. This study explores the integration of SCG acquired through smartphone technology by assessing the accuracy of metrics derived from smartphone recordings and their consistency when performed by patients. Therefore, we assessed smartphone-derived SCG's reliability in computing median kinetic energy parameters per record in 220 patients with various cardiovascular conditions. The study involved three key procedures: (1) simultaneous measurements of a validated hardware device and a commercial smartphone; (2) consecutive smartphone recordings performed by both clinicians and patients; (3) patients' self-conducted home recordings over three months. Our findings indicate a moderate-to-high reliability of smartphone-acquired SCG metrics compared to those obtained from a validated device, with intraclass correlation (ICC) > 0.77. The reliability of patient-acquired SCG metrics was high (ICC > 0.83). Within the cohort, 138 patients had smartphones that met the compatibility criteria for the study, with an observed at-home compliance rate of 41.4%. This research validates the potential of smartphone-derived SCG acquisition in providing repeatable SCG metrics in telemedicine, thus laying a foundation for future studies to enhance the precision of at-home cardiac data acquisition.


Assuntos
Doenças Cardiovasculares , Smartphone , Humanos , Reprodutibilidade dos Testes , Fenômenos Físicos , Benchmarking , Doenças Cardiovasculares/diagnóstico
3.
ESC Heart Fail ; 10(6): 3446-3453, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37710415

RESUMO

AIMS: To improve telemonitoring strategies in heart failure patients, there is a need for novel non-obtrusive sensors that monitor parameters closely related to intracardiac filling pressures. This proof-of-concept study aims to evaluate the responsiveness of cardiac kinetic energy (KE) measured with the Kinocardiograph (KCG), consisting of a seismocardiographic (SCG) sensor and a ballistocardiographic (BCG) sensor, during treatment of patients with acute decompensated heart failure. METHODS AND RESULTS: Eleven patients with acute decompensated heart failure who were hospitalized for treatment with intravenous diuretics received daily KCG measurements. The KCG measurements were compared with the diameter of the inferior vena cava (IVC) and body weight. Follow-up stopped at discharge, that is, in the recompensated state. Median (interquartile range) weight and IVC diameter decreased significantly after diuretic treatment [weight 74.5 (67.6-98.7) to 73.3 (66.7-95.6) kg, P = 0.003; IVC diameter 2.47 (2.33-2.99) to 1.78 (1.65-2.47) cm, P = 0.03]. In contrast with BCG measurements, significant changes in median KE measured with SCG were observed during the passive filling phase of the diastole [SGG: 0.48 (0.39-0.60) to 0.69 (0.56-0.84), P = 0.026; BCG: 0.68 (0.46-0.73) to 0.68 (0.59-0.82), P = 0.062], the active filling phase of the diastole [SCG: 0.38 (0.30-0.61) to 0.31 (0.09-0.47), P = 0.016; BCG: 0.29 (0.17-0.39) to 0.26 (0.20-0.34), P = 0.248], and the ratio between the passive and active filling phases [SCG: 2.76 (1.68-5.30) to 5.02 (3.13-10.17), P = 0.006; BCG: 5.87 (3.57-7.55) to 5.27 (3.95-9.43), P = 0.790]. The correlations between changes in KE during the passive and active filling phases, using SCG, and changes in weight or IVC were non-significant. Systolic KE did not show significant changes. CONCLUSION: KE measured with the KCG using SCG is highly responsive to changes in fluid status. Future research is needed to confirm its accuracy in a larger study population and specifically its application for detection of clinical deterioration in the home-environment.


Assuntos
Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/diagnóstico , Coração , Diuréticos/uso terapêutico , Diástole , Sístole
4.
Front Cardiovasc Med ; 10: 1096859, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37200972

RESUMO

Background: Heart failure (HF) remains a major cause of mortality, morbidity, and poor quality of life. 44% of HF patients present impaired left ventricular ejection fraction (LVEF). Kinocardiography (KCG) technology combines ballistocardiography (BCG) and seismocardiography (SCG). It estimates myocardial contraction and blood flow through the cardiac chambers and major vessels through a wearable device. Kino-HF sought to evaluate the potential of KCG to distinguish HF patients with impaired LVEF from a control group. Methods: Successive patients with HF and impaired LVEF (iLVEF group) were matched and compared to patients with normal LVEF ≥ 50% (control). A 60 s KCG acquisition followed cardiac ultrasound. The kinetic energy from KCG signals was computed in different phases of the cardiac cycle (iKsystolic;ΔiKdiastolic) as markers of cardiac mechanical function. Results: Thirty HF patients (67 [59; 71] years, 87% male) were matched with 30 controls (64.5 [49; 73] years, 87% male). SCG ΔiKdiastolic, BCG iKsystolic, BCG ΔiKdiastolic were lower in HF than controls (p < 0.05), while SCG iKsystolic was similar. Furthermore, a lower SCG iKsystolic was associated with an increased mortality risk during follow-up. Conclusions: KINO-HF demonstrates that KCG can distinguish HF patients with impaired systolic function from a control group. These favorable results warrant further research on the diagnostic and prognostic capabilities of KCG in HF with impaired LVEF.Clinical Trial Registration: NCT03157115.

5.
Sensors (Basel) ; 22(23)2022 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36502267

RESUMO

Ballistocardiography (BCG) and seismocardiography (SCG) are non-invasive techniques used to record the micromovements induced by cardiovascular activity at the body's center of mass and on the chest, respectively. Since their inception, their potential for evaluating cardiovascular health has been studied. However, both BCG and SCG are impacted by respiration, leading to a periodic modulation of these signals. As a result, data processing algorithms have been developed to exclude the respiratory signals, or recording protocols have been designed to limit the respiratory bias. Reviewing the present status of the literature reveals an increasing interest in applying these techniques to extract respiratory information, as well as cardiac information. The possibility of simultaneous monitoring of respiratory and cardiovascular signals via BCG or SCG enables the monitoring of vital signs during activities that require considerable mental concentration, in extreme environments, or during sleep, where data acquisition must occur without introducing recording bias due to irritating monitoring equipment. This work aims to provide a theoretical and practical overview of cardiopulmonary interaction based on BCG and SCG signals. It covers the recent improvements in extracting respiratory signals, computing markers of the cardiorespiratory interaction with practical applications, and investigating sleep breathing disorders, as well as a comparison of different sensors used for these applications. According to the results of this review, recent studies have mainly concentrated on a few domains, especially sleep studies and heart rate variability computation. Even in those instances, the study population is not always large or diversified. Furthermore, BCG and SCG are prone to movement artifacts and are relatively subject dependent. However, the growing tendency toward artificial intelligence may help achieve a more accurate and efficient diagnosis. These encouraging results bring hope that, in the near future, such compact, lightweight BCG and SCG devices will offer a good proxy for the gold standard methods for assessing cardiorespiratory function, with the added benefit of being able to perform measurements in real-world situations, outside of the clinic, and thus decrease costs and time.


Assuntos
Inteligência Artificial , Balistocardiografia , Humanos , Processamento de Sinais Assistido por Computador , Balistocardiografia/métodos , Taxa Respiratória , Frequência Cardíaca/fisiologia , Eletrocardiografia
6.
ESC Heart Fail ; 8(6): 4925-4932, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34687162

RESUMO

AIMS: The kinocardiograph (KCG) is an unobtrusive device, consisting of a chest sensor, which records local thoracic vibrations produced in result of cardiac contraction and ejection of blood into the great vessels [seismocardiography (SCG)], and a lower back sensor, which records micromovements of the body in reaction to blood flowing through the vasculature [ballistocardiography (BCG)]. SCG and BCG signals are translated to the integral of cardiac kinetic energy (iK) and cardiac maximum power (Pmax), which might be promising metrics for future telemonitoring purposes in heart failure (HF). As a first step of validation, this study aimed to determine whether iK and Pmax are responsive to exercise-induced changes in the haemodynamic load of the heart in HF patients. METHODS AND RESULTS: Fifteen patients with stable HF with reduced ejection fraction performed a submaximal exercise protocol. KCG and cardiac ultrasound measurements were obtained both at rest and at submaximal exercise. BCG iK over the cardiac cycle (CC) increased significantly (0.0026 ± 0.0017 to 0.0052 ± 0.0061 mJ.s.; P = 0.01) during exercise, in contrast to a non-significant increase in SCG iK CC. BCG Pmax CC increased significantly (0.92 ± 0.89 to 2.03 ± 1.95 mJ/s; P = 0.02), in contrast to a non-significant increase in SCG Pmax CC. When analysing the systolic phase of the CC, similar patterns were found. Cardiac output (CO) ratio (i.e. CO exercise/CO rest) showed a moderate, significant correlation with BCG Pmax CC ratio (r = +0.65; P = 0.008) and with SCG Pmax CC ratio (r = +0.54; P = 0.04). CONCLUSIONS: iK and Pmax measured with the KCG, preferentially using BCG, are responsive to changes in the haemodynamic load of the heart in HF patients. The combination of the BCG and SCG sensor might be of added value to fully understand changes in haemodynamics and to discriminate between an HF patient and a healthy individual.


Assuntos
Balistocardiografia , Insuficiência Cardíaca , Balistocardiografia/métodos , Insuficiência Cardíaca/diagnóstico , Hemodinâmica , Humanos , Contração Miocárdica , Volume Sistólico
7.
Front Cardiovasc Med ; 8: 603319, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33763456

RESUMO

Introduction: Seismocardiography (SCG) records cardiac and blood-induced motions transmitted to the chest surface as vibratory phenomena. Evidences demonstrate that acute myocardial ischemia (AMI) profoundly affects the SCG signals. Multidimensional SCG records cardiac vibrations in linear and rotational dimensions, and scalar parameters of kinetic energy can be computed. We speculate that AMI and revascularization profoundly modify cardiac kinetic energy as recorded by SCG. Methods: Under general anesthesia, 21 swine underwent 90 min of myocardial ischemia induced by percutaneous sub-occlusion of the proximal left anterior descending (LAD) coronary artery and subsequent revascularization. Invasive hemodynamic parameters were continuously recorded. SCG was recorded during baseline, immediately and 80 min after LAD sub-occlusion, and immediately and 60 min after LAD reperfusion. iK was automatically computed for each cardiac cycle (iK CC ) in linear (iK Lin ) and rotational (iK Rot ) dimensions. iK was calculated as well during systole and diastole (iK Sys and iK Dia , respectively). Echocardiography was performed at baseline and after revascularization, and the left ventricle ejection fraction (LVEF) along with regional left ventricle (LV) wall abnormalities were evaluated. Results: Upon LAD sub-occlusion, 77% of STEMI and 24% of NSTEMI were observed. Compared to baseline, troponins increased from 13.0 (6.5; 21.3) ng/dl to 170.5 (102.5; 475.0) ng/dl, and LVEF dropped from 65.0 ± 0.0 to 30.6 ± 5.7% at the end of revascularization (both p < 0.0001). Regional LV wall abnormalities were observed as follows: anterior MI, 17.6% (three out of 17); septal MI, 5.8% (one out of 17); antero-septal MI, 47.1% (eight out of 17); and infero-septal MI, 29.4% (five out of 17). In the linear dimension, i K L i n C C , i K L i n S y s , and i K L i n D i a dropped by 43, 52, and 53%, respectively (p < 0.0001, p < 0.0001, and p = 0.03, respectively) from baseline to the end of reperfusion. In the rotational dimension, i K R o t C C and i K R o t S y s dropped by 30 and 36%, respectively (p = 0.0006 and p < 0.0001, respectively), but i K R o t D i a did not change (p = 0.41). All the hemodynamic parameters, except the pulmonary artery pulse pressure, were significantly correlated with the parameters of iK, except for the diastolic component. Conclusions: In this very context of experimental AMI with acute LV regional dysfunction and no concomitant AMI-related heart valve disease, linear and rotational iK parameters, in particular, systolic ones, provide reliable information on LV contractile dysfunction and its effects on the downstream circulation. Multidimensional SCG may provide information on the cardiac contractile status expressed in terms of iK during AMI and reperfusion. This automatic system may empower health care providers and patients to remotely monitor cardiovascular status in the near future.

8.
Sensors (Basel) ; 21(3)2021 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-33530417

RESUMO

Recent years have witnessed an upsurge in the usage of ballistocardiography (BCG) and seismocardiography (SCG) to record myocardial function both in normal and pathological populations. Kinocardiography (KCG) combines these techniques by measuring 12 degrees-of-freedom of body motion produced by myocardial contraction and blood flow through the cardiac chambers and major vessels. The integral of kinetic energy (iK) obtained from the linear and rotational SCG/BCG signals, and automatically computed over the cardiac cycle, is used as a marker of cardiac mechanical function. The present work systematically evaluated the test-retest (TRT) reliability of KCG iK derived from BCG/SCG signals in the short term (<15 min) and long term (3-6 h) on 60 healthy volunteers. Additionally, we investigated the difference of repeatability with different body positions. First, we found high short-term TRT reliability for KCG metrics derived from SCG and BCG recordings. Exceptions to this finding were limited to metrics computed in left lateral decubitus position where the TRT reliability was moderate-to-high. Second, we found low-to-moderate long-term TRT reliability for KCG metrics as expected and confirmed by blood pressure measurements. In summary, KCG parameters derived from BCG/SCG signals show high repeatability and should be further investigated to confirm their use for cardiac condition longitudinal monitoring.


Assuntos
Balistocardiografia , Eletrocardiografia , Voluntários Saudáveis , Coração , Humanos , Contração Miocárdica , Reprodutibilidade dos Testes
9.
Sci Rep ; 11(1): 683, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-33436841

RESUMO

Ballistocardiography (BCG) and Seismocardiography (SCG) assess the vibrations produced by cardiac contraction and blood flow, respectively, by means of micro-accelerometers and micro-gyroscopes. From the BCG and SCG signals, maximal velocities (VMax), integral of kinetic energy (iK), and maximal power (PMax) can be computed as scalar parameters, both in linear and rotational dimensions. Standard echocardiography and 2-dimensional speckle tracking imaging echocardiography were performed on 34 healthy volunteers who were infused with increasing doses of dobutamine (5-10-20 µg/kg/min). Linear VMax of BCG predicts the rates of left ventricular (LV) twisting and untwisting (both p < 0.0001). The linear PMax of both SCG and BCG and the linear iK of BCG are the best predictors of the LV ejection fraction (LVEF) (p < 0.0001). This result is further confirmed by mathematical models combining the metrics from SCG and BCG signals with heart rate, in which both linear PMax and iK strongly correlate with LVEF (R = 0.7, p < 0.0001). In this setting of enhanced inotropism, the linear VMax of BCG, rather than the VMax of SCG, is the metric which best explains the LV twist mechanics, in particular the rates of twisting and untwisting. PMax and iK metrics are strongly associated with the LVEF and account for 50% of the variance of the LVEF.


Assuntos
Balistocardiografia/métodos , Dobutamina/administração & dosagem , Ecocardiografia/métodos , Ventrículos do Coração/fisiopatologia , Contração Miocárdica , Função Ventricular Esquerda/fisiologia , Adolescente , Adulto , Cardiotônicos/administração & dosagem , Feminino , Voluntários Saudáveis , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos , Adulto Jovem
10.
Biomed Eng Online ; 20(1): 3, 2021 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-33407507

RESUMO

BACKGROUND: Kinocardiography (KCG) is a promising new technique used to monitor cardiac mechanical function remotely. KCG is based on ballistocardiography (BCG) and seismocardiography (SCG), and measures 12 degrees-of-freedom (DOF) of body motion produced by myocardial contraction and blood flow through the cardiac chambers and major vessels. RESULTS: The integral of kinetic energy ([Formula: see text]) obtained from the linear and rotational SCG/BCG signals was computed over each dimension over the cardiac cycle, and used as a marker of cardiac mechanical function. We tested the hypotheses that KCG metrics can be acquired using different sensors, and at 50 Hz. We also tested the effect of record length on the ensemble average on which the metrics were computed. Twelve healthy males were tested in the supine, head-down tilt, and head-up tilt positions to expand the haemodynamic states on which the validation was performed. CONCLUSIONS: KCG metrics computed on 50 Hz and 1 kHz SCG/BCG signals were very similar. Most of the metrics were highly similar when computed on different sensors, and with less than 5% of error when computed on record length longer than 60 s. These results suggest that KCG may be a robust and non-invasive method to monitor cardiac inotropic activity. Trial registration Clinicaltrials.gov, NCT03107351. Registered 11 April 2017, https://clinicaltrials.gov/ct2/show/NCT03107351?term=NCT03107351&draw=2&rank=1 .


Assuntos
Balistocardiografia , Hemodinâmica , Processamento de Sinais Assistido por Computador , Eletrocardiografia , Coração , Frequência Cardíaca , Humanos , Masculino , Monitorização Fisiológica
11.
Sci Rep ; 10(1): 17694, 2020 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-33077727

RESUMO

Head-down bed rest (HDBR) reproduces the cardiovascular effects of microgravity. We tested the hypothesis that regular high-intensity physical exercise (JUMP) could prevent this cardiovascular deconditioning, which could be detected using seismocardiography (SCG) and ballistocardiography (BCG). 23 healthy males were exposed to 60-day HDBR: 12 in a physical exercise group (JUMP), the others in a control group (CTRL). SCG and BCG were measured during supine controlled breathing protocols. From the linear and rotational SCG/BCG signals, the integral of kinetic energy ([Formula: see text]) was computed on each dimension over the cardiac cycle. At the end of HDBR, BCG rotational [Formula: see text] and SCG transversal [Formula: see text] decreased similarly for all participants (- 40% and - 44%, respectively, p < 0.05), and so did orthostatic tolerance (- 58%, p < 0.01). Resting heart rate decreased in JUMP (- 10%, p < 0.01), but not in CTRL. BCG linear [Formula: see text] decreased in CTRL (- 50%, p < 0.05), but not in JUMP. The changes in the systolic component of BCG linear iK were correlated to those in stroke volume and VO2 max (R = 0.44 and 0.47, respectively, p < 0.05). JUMP was less affected by cardiovascular deconditioning, which could be detected by BCG in agreement with standard markers of the cardiovascular condition. This shows the potential of BCG to easily monitor cardiac deconditioning.


Assuntos
Adaptação Fisiológica , Balistocardiografia/métodos , Fenômenos Fisiológicos Cardiovasculares , Simulação de Ausência de Peso , Adulto , Decúbito Inclinado com Rebaixamento da Cabeça , Humanos , Masculino , Adulto Jovem
12.
Am J Physiol Regul Integr Comp Physiol ; 319(4): R497-R506, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32877240

RESUMO

Ballistocardiography (BCG) and seismocardiography (SCG) assess vibrations produced by cardiac contraction and blood flow, respectively, through micro-accelerometers and micro-gyroscopes. BCG and SCG kinetic energies (KE) and their temporal integrals (iK) during a single heartbeat are computed in linear and rotational dimensions. Our aim was to test the hypothesis that iK from BCG and SCG are related to sympathetic activation during maximal voluntary end-expiratory apnea. Multiunit muscle sympathetic nerve traffic [burst frequency (BF), total muscular sympathetic nerve activity (tMSNA)] was measured by microneurography during normal breathing and apnea (n = 28, healthy men). iK of BCG and SCG were simultaneously recorded in the linear and rotational dimension, along with oxygen saturation ([Formula: see text]) and systolic blood pressure (SBP). The mean duration of apneas was 25.4 ± 9.4 s. SBP, BF, and tMSNA increased during the apnea compared with baseline (P = 0.01, P = 0.002,and P = 0.001, respectively), whereas [Formula: see text] decreased (P = 0.02). At the end of the apnea compared with normal breathing, changes in iK computed from BCG were related to changes of tMSNA and BF only in the linear dimension (r = 0.85, P < 0.0001; and r = 0.72, P = 0.002, respectively), whereas changes in linear iK of SCG were related only to changes of tMSNA (r = 0.62, P = 0.01). We conclude that maximal end expiratory apnea increases cardiac kinetic energy computed from BCG and SCG, along with sympathetic activity. The novelty of the present investigation is that linear iK of BCG is directly and more strongly related to the rise in sympathetic activity than the SCG, mainly at the end of a sustained apnea, likely because the BCG is more affected by the sympathetic and hemodynamic effects of breathing cessation. BCG and SCG may prove useful to assess sympathetic nerve changes in patients with sleep disturbances.NEW & NOTEWORTHY Ballistocardiography (BCG) and seismocardiography (SCG) assess vibrations produced by cardiac contraction and blood flow, respectively, through micro-accelerometers and micro-gyroscopes. Kinetic energies (KE) and their temporal integrals (iK) during a single heartbeat are computed from the BCG and SCG waveforms in a linear and a rotational dimension. When compared with normal breathing, during an end-expiratory voluntary apnea, iK increased and was positively related to sympathetic nerve traffic rise assessed by microneurography. Further studies are needed to determine whether BCG and SCG can probe sympathetic nerve changes in patients with sleep disturbances.


Assuntos
Apneia/fisiopatologia , Contração Miocárdica/fisiologia , Sistema Nervoso Simpático/fisiologia , Adulto , Balistocardiografia , Pressão Sanguínea/fisiologia , Frequência Cardíaca/fisiologia , Humanos , Masculino
13.
Physiol Meas ; 41(6): 065007, 2020 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-32396890

RESUMO

OBJECTIVE: To investigate if modern seismocardiography (SCG) and ballistocardiography (BCG) are useful in the detection of hemodynamic changes occurring during simulated obstructive apneic events. METHODS: Forty-seven healthy volunteers performed a voluntary maximum Mueller maneuver (MM) for 10 s, and SCG and BCG signals were simultaneously taken. The kinetic energy of a set of cardiac cycles before and during the apneic episode was automatically computed from the rotational and linear channels of the SCG and BCG waveforms and its temporal integral (i K) was derived (unit of measure: microjoules per second (µJ·s)). The estimated transmural pressure (eP TM ) was assessed as the difference between systemic blood pressure and maximal inspiratory pressure (MIP). The Wilcoxon sign-rank test was used to evaluate differences in energy measurements between normal respiration and the loaded inspiration maneuver. Cardiac kinetic energies and the MIP produced during the MM were compared by linear regression analysis following log transformation in order to assess the correlation between variables. MAIN RESULTS: The [Formula: see text] during normal breathing increased from 1.1(0.8; 1.4) to 1.9(1.4; 4.3) µJ·s during MM (p < 0.001). Meanwhile, [Formula: see text] increased from 54 (31; 92) to 84 (44; 153) µJ·s, (p < 0.001). The [Formula: see text] and [Formula: see text] of a set of cardiac cycles during the MM were negatively associated with the MIP (r: -0.59, p < 0.001 and r: -0.53, p = 0.001 for [Formula: see text] and [Formula: see text], respectively). When eP TM was considered, this association became positive (r: +0.58, p < 0.001 and r:+0.60, p < 0.001, for [Formula: see text] and [Formula: see text], respectively). When the i K LIN was considered as the comparative factor, correlations with the MIP and eP TM were weak and insignificant. Men had higher values of i K than women. SIGNIFICANCE: Simulated obstructive apnea elicits large rotational i K swings, which are related to the intensity of the inspiratory effort and, as such, to the intensity of the left ventricular afterload. Computation of cardiac kinetic energy through BCG and SCG may shed further light on the impact of obstructive respiratory events on the cardiovascular system.


Assuntos
Balistocardiografia , Hemodinâmica , Apneia Obstrutiva do Sono , Feminino , Coração , Humanos , Masculino , Apneia Obstrutiva do Sono/diagnóstico
15.
Physiol Meas ; 40(10): 105005, 2019 11 04.
Artigo em Inglês | MEDLINE | ID: mdl-31579047

RESUMO

OBJECTIVE: To assess if micro-accelerometers and gyroscopes may provide useful information for the detection of breathing disturbances in further studies. APPROACH: Forty-three healthy volunteers performed a 10 s end-expiratory breath-hold, while ballistocardiograph (BCG) and seismocardiograph (SCG) determined changes in kinetic energy and its integral over time (iK, J · s). BCG measures overall body accelerations in response to blood mass ejection into the main vasculature at each cardiac cycle, while SCG records local chest wall vibrations generated beat-by-beat by myocardial activity. This minimally intrusive technology assesses linear accelerations and angular velocities in 12 degrees of freedom to calculate iK during the whole cardiac cycle. iK produced during systole and diastole were also computed. MAIN RESULTS: The iK during normal breathing was 87.1 [63.3; 132.8] µJ · s for the SCG and 4.5 [3.3; 6.2] µJ · s for the BCG. Both increased to 107.1 [69.0; 162.0] µJ · s and 6.1 [4.4; 9.0] µJ · s, respectively, during breath-holding (p  = 0.003 and p  < 0.0001, respectively). The iK of the SCG further increased during spontaneous respiration following apnea (from 107.1 [69.0; 162.0] µJ · s to 160.0 [96.3; 207.3] µJ · s, p  < 0.0001). The ratio between the iK of diastole and systole increased from 0.35 [0.24; 0.45] during apnea to 0.49 [0.31; 0.80] (p  < 0.0001) during the restoration of respiration. SIGNIFICANCE: A brief voluntary apnea generates large and distinct increases in SCG and BCG waveforms. iK monitoring during sleep may prove useful for the detection of respiratory disturbances. ClinicalTrials.gov number: NCT03760159.


Assuntos
Apneia/fisiopatologia , Balistocardiografia , Eletrocardiografia , Coração/fisiopatologia , Fenômenos Mecânicos , Respiração , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Contração Miocárdica , Processamento de Sinais Assistido por Computador , Adulto Jovem
16.
Sci Rep ; 9(1): 10479, 2019 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-31324831

RESUMO

Non-invasive remote detection of cardiac and blood displacements is an important topic in cardiac telemedicine. Here we propose kino-cardiography (KCG), a non-invasive technique based on measurement of body vibrations produced by myocardial contraction and blood flow through the cardiac chambers and major vessels. KCG is based on ballistocardiography and measures 12 degrees-of-freedom (DOF) of body motion. We tested the hypothesis that KCG reliably assesses dobutamine-induced haemodynamic changes in healthy subjects. Using a randomized double-blinded placebo-controlled crossover study design, dobutamine and placebo were infused to 34 volunteers (25 ± 2 years, BMI 22 ± 2 kg/m², 18 females). Baseline recordings were followed by 3 sessions of increasing doses of dobutamine (5, 10, 20 µg/kg.min) or saline solution. During each session, stroke volume (SV) and cardiac output (CO) were determined by echocardiography and followed by a 90 s KCG recording. Measured linear accelerations and angular velocities were used to compute total Kinetic energy (iK) and power (Pmax). KCG sorted dobutamine infusion vs. placebo with 96.9% accuracy. Increases in SV and CO were correlated to iK (r = +0.71 and r = +0.8, respectively, p < 0.0001). Kino-cardiography, with 12-DOF, allows detecting dobutamine-induced haemodynamic changes with a high accuracy and present a major improvement over single axis ballistocardiography or seismocardiography.


Assuntos
Cardiotônicos/farmacologia , Dobutamina/farmacologia , Coração/diagnóstico por imagem , Hemodinâmica/efeitos dos fármacos , Cinetocardiografia/métodos , Adulto , Débito Cardíaco/efeitos dos fármacos , Estudos Cross-Over , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Coração/efeitos dos fármacos , Coração/fisiologia , Humanos , Masculino , Contração Miocárdica , Reprodutibilidade dos Testes , Volume Sistólico/efeitos dos fármacos