Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ultrasound Med Biol ; 42(2): 503-17, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26547634

RESUMO

Real-time monitoring of the spatiotemporal evolution of tissue temperature is important to ensure safe and effective treatment in thermal therapies including hyperthermia and thermal ablation. Ultrasound thermography has been proposed as a non-invasive technique for temperature measurement, and accurate calibration of the temperature-dependent ultrasound signal changes against temperature is required. Here we report a method that uses infrared thermography for calibration and validation of ultrasound thermography. Using phantoms and cardiac tissue specimens subjected to high-intensity focused ultrasound heating, we simultaneously acquired ultrasound and infrared imaging data from the same surface plane of a sample. The commonly used echo time shift-based method was chosen to compute ultrasound thermometry. We first correlated the ultrasound echo time shifts with infrared-measured temperatures for material-dependent calibration and found that the calibration coefficient was positive for fat-mimicking phantom (1.49 ± 0.27) but negative for tissue-mimicking phantom (-0.59 ± 0.08) and cardiac tissue (-0.69 ± 0.18°C-mm/ns). We then obtained the estimation error of the ultrasound thermometry by comparing against the infrared-measured temperature and revealed that the error increased with decreased size of the heated region. Consistent with previous findings, the echo time shifts were no longer linearly dependent on temperature beyond 45°C-50°C in cardiac tissues. Unlike previous studies in which thermocouples or water bath techniques were used to evaluate the performance of ultrasound thermography, our results indicate that high-resolution infrared thermography is a useful tool that can be applied to evaluate and understand the limitations of ultrasound thermography methods.


Assuntos
Raios Infravermelhos , Imagens de Fantasmas , Termografia/instrumentação , Termografia/métodos , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Algoritmos , Animais , Calibragem , Desenho de Equipamento , Análise de Falha de Equipamento , Técnicas In Vitro , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos , Termografia/normas , Ultrassonografia/normas , Estados Unidos
2.
Retina ; 35(11): 2353-63, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26465617

RESUMO

PURPOSE: To describe a new method of retinal vascular perfusion density mapping using optical coherence tomography angiography and to compare current staging of diabetic retinopathy based on clinical features with a new grading scale based on perifoveal perfusion densities. METHODS: A retrospective review was performed on subjects with diabetic retinopathy and age-matched controls imaged with a spectral domain optical coherence tomography system (Optovue XR Avanti, Fremont, CA). Split-spectrum amplitude-decorrelation angiography (SSADA) generated optical coherence tomography angiograms of the superficial retinal capillaries, deep retinal capillaries, and choriocapillaris. Skeletonized optical coherence tomography angiograms were used to create color-coded perfusion maps and capillary perfusion density values for each image. Capillary perfusion density values were compared with clinical staging, and groups were compared using analysis of variance and Kruskal-Wallis analyses. RESULTS: Twenty-one control and 56 diabetic retinopathy eyes were imaged. Diabetic eyes were grouped according to clinical stage. Capillary perfusion density values from each microvascular layer were compared across all groups. Capillary perfusion density values were significantly lower in nearly all layers of all study groups compared with controls. Trend analysis showed a significant decrease in capillary perfusion density values as retinopathy progresses for most layers. CONCLUSION: Quantitative retinal vascular perfusion density mapping agreed closely with grading based on clinical features and may offer an objective method for monitoring disease progression in diabetic retinopathy.


Assuntos
Retinopatia Diabética/fisiopatologia , Angiofluoresceinografia , Vasos Retinianos/patologia , Tomografia de Coerência Óptica , Adulto , Idoso , Velocidade do Fluxo Sanguíneo/fisiologia , Capilares/fisiopatologia , Corioide/fisiopatologia , Retinopatia Diabética/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Retina/fisiopatologia , Estudos Retrospectivos , Acuidade Visual/fisiologia
3.
Opt Lett ; 40(8): 1721-4, 2015 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-25872057

RESUMO

The feasibility of an innovative biomedical diagnostic technique, thermal photo-acoustic (TPA) measurement, for non-ionizing and non-invasive assessment of bone health is investigated. Unlike conventional photo-acoustic PA methods that are mostly focused on the measurement of absolute signal intensity, TPA targets the change in PA signal intensity as a function of the sample temperature, i.e., the temperature-dependent Grueneisen parameter that is closely relevant to the chemical and molecular properties in the sample. Based on the differentiation measurement, the results from TPA technique are less susceptible to the variations associated with sample and system, and could be quantified with improved accurately. Due to the fact that the PA signal intensity from organic components such as blood changes faster than that from non-organic mineral under the same modulation of temperature, TPA measurement is able to objectively evaluate bone mineral density (BMD) and its loss as a result of osteoporosis. In an experiment on well-established rat models of bone loss and preservation, PA measurements of rat tibia bones were conducted over a temperature range from 37°C to 44°C. The slope of PA signal intensity verses temperature was quantified for each specimen. The comparison among three groups of specimens with different BMD shows that bones with lower BMD have higher slopes, demonstrating the potential of the proposed TPA technique in future clinical management of osteoporosis.


Assuntos
Técnicas Fotoacústicas/métodos , Temperatura , Tíbia , Animais , Densidade Óssea , Feminino , Humanos , Ratos , Tíbia/citologia , Tíbia/fisiologia
4.
Biophys J ; 108(1): 32-42, 2015 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-25564850

RESUMO

The study of mechanotransduction relies on tools that are capable of applying mechanical forces to elicit and assess cellular responses. Here we report a new (to our knowledge) technique, called two-bubble acoustic tweezing cytometry (TB-ATC), for generating spatiotemporally controlled subcellular mechanical forces on live cells by acoustic actuation of paired microbubbles targeted to the cell adhesion receptor integrin. By measuring the ultrasound-induced activities of cell-bound microbubbles and the actin cytoskeleton contractile force responses, we determine that TB-ATC elicits mechanoresponsive cellular changes via cyclic, paired displacements of integrin-bound microbubbles driven by the attractive secondary acoustic radiation force (sARF) between the bubbles in an ultrasound field. We demonstrate the feasibility of dual-mode TB-ATC for both subcellular probing and mechanical stimulation. By exploiting the robust and unique interaction of ultrasound with microbubbles, TB-ATC provides distinct advantages for experimentation and quantification of applied forces and cellular responses for biomechanical probing and stimulation of cells.


Assuntos
Técnicas Citológicas/métodos , Mecanotransdução Celular/fisiologia , Ultrassom/métodos , Actinas/metabolismo , Animais , Citoesqueleto/fisiologia , Estudos de Viabilidade , Fibroblastos/fisiologia , Humanos , Integrinas/química , Células-Tronco Mesenquimais/fisiologia , Camundongos , Microscopia , Células NIH 3T3 , Gravação em Vídeo
5.
Infrared Phys Technol ; 60: 108-117, 2013 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-23878517

RESUMO

Successful high-intensity focused ultrasound (HIFU) thermal tissue ablation relies on accurate information of the tissue temperature and tissue status. Often temperature measurements are used to predict and monitor the ablation process. In this study, we conducted HIFU ablation experiments with ex vivo porcine myocardium tissue specimens to identify changes in temperature associated with tissue coagulation and bubble/cavity formation. Using infrared (IR) thermography and synchronized bright-field imaging with HIFU applied near the tissue surface, parameters derived from the spatiotemporal evolution of temperature were correlated with HIFU-induced lesion formation and overheating, of which the latter typically results in cavity generation and/or tissue dehydration. Emissivity of porcine myocardium was first measured to be 0.857 ± 0.006 (n = 3). HIFU outcomes were classified into non-ablative, normal lesion, and overheated lesion. A marked increase in the rate of temperature change during HIFU application was observed with lesion formation. A criterion using the maximum normalized second time derivative of temperature change provided 99.1% accuracy for lesion identification with a 0.05 s-1 threshold. Asymmetric temperature distribution on the tissue surface was observed to correlate with overheating and/or bubble generation. A criterion using the maximum displacement of the spatial location of the peak temperature provided 90.9% accuracy to identify overheated lesion with a 0.16 mm threshold. Spatiotemporal evolution of temperature obtained using IR imaging allowed determination of the cumulative equivalent minutes at 43 °C (CEM43) for lesion formation to be 170 min. Similar temperature characteristics indicative of lesion formation and overheating were identified for subsurface HIFU ablation. These results suggest that parameters derived from temperature changes during HIFU application are associated with irreversible changes in tissue and may provide useful information for monitoring HIFU treatment.

6.
Ultrasound Med Biol ; 39(10): 1760-70, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23849388

RESUMO

The acoustic and thermal properties as well as the temperature change within a tissue volume during high-intensity focused ultrasound ablation are critically important for treatment planning and monitoring. Described in this article is a tomographic reconstruction method used to determine the tissue properties and increase in temperature in a 3-D volume. On the basis of the iterative finite-element solution to the bioheat equation coupled with Tikhonov regularization techniques, our reconstruction algorithm solves the inverse problem of bioheat transfer and uses the time-dependent temperature measured on a tissue surface to obtain the acoustic absorption coefficient, thermal diffusivity and temperature increase within the subsurface volume. Numerical simulations were performed to validate the reconstruction algorithm. The method was initially conducted in ex vivo experiments in which time-dependent temperature on a tissue surface was measured using high-resolution, non-invasive infrared thermography.


Assuntos
Temperatura Corporal/fisiologia , Temperatura Corporal/efeitos da radiação , Procedimentos Cirúrgicos Cardiovasculares/métodos , Coração/fisiologia , Coração/efeitos da radiação , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Modelos Biológicos , Absorção , Animais , Simulação por Computador , Relação Dose-Resposta à Radiação , Ondas de Choque de Alta Energia , Técnicas In Vitro , Doses de Radiação , Espalhamento de Radiação , Suínos , Termografia/métodos
7.
J Biomed Opt ; 18(6): 067003, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23733048

RESUMO

Photoacoustic (PA) techniques have been exploited for monitoring thermal treatments. However, PA signals depend not only on tissue temperature but also on tissue optical properties which indicate tissue status (e.g., native or coagulated). The changes in temperature and tissue status often occur simultaneously during thermal treatments, so both effects cause changes to PA signals. A new dual-wavelength PA technique to monitor tissue status independent of temperature is performed. By dividing the PA signal intensities obtained at two wavelengths at the same temperature, a ratio, which only depends on tissue optical properties, is obtained. Experiments were performed with two experimental groups, one with untreated tissue samples and the other with high-intensity focused ultrasound treated tissue samples including thermal coagulated lesion, using ex vivo porcine myocardium specimens to test the technique. The ratio of PA signal intensities obtained at 700 and 800 nm was constant for both groups from 25 to 43°C, but with distinct values for the two groups. Tissue alteration during thermal treatment was then studied using water bath heating of tissue samples from 35 to 60°C. We found that the ratio stayed constant before it exhibited a marked increase at around 55°C, indicating tissue changes at this temperature.


Assuntos
Miocárdio/patologia , Técnicas Fotoacústicas , Temperatura , Animais , Coagulação Sanguínea , Calibragem , Desenho de Equipamento , Imageamento por Ressonância Magnética , Óptica e Fotônica , Suínos
8.
Tissue Eng Part C Methods ; 18(12): 935-46, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22624791

RESUMO

As tissue engineering products move toward the clinic, nondestructive methods to monitor their development and ensure quality are needed. In this study, high-resolution spectral ultrasound imaging (SUSI) was used to noninvasively characterize mineral content in collagen hydrogels. SUSI was used to generate three-dimensional (3D) grayscale (GS) images of construct morphology with submillimeter resolution. Spectral analysis of the backscattered radio frequency (RF) ultrasound signals was used to determine the midband fit (MBF) and slope of the linearized RF spectrum. These parameters are operator and instrument independent, and were used to characterize the spatial distribution of mineral in constructs supplemented with hydroxyapatite particles. GS and MBF correlated closely with mineral content, while slope was not dependent on concentration. SUSI also was used to monitor mineralization of collagen constructs by immersion in simulated body fluid (SBF) over 21 days. The construct surface was mineralized before the interior, and there was a dose-dependent effect of SBF concentration on degree of mineralization and deposited particle size. MBF density was closely correlated with the amount of calcium deposited. These data demonstrate that SUSI has utility as a noninvasive imaging method for quantitative analysis of mineralization in 3D protein constructs. Such techniques may assist the development of engineered orthopedic tissues.


Assuntos
Colágeno/química , Hidrogéis , Ultrassom , Líquidos Corporais , Cálcio/química
9.
Gastrointest Endosc ; 75(6): 1175-83, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22498178

RESUMO

BACKGROUND: Spectral analysis of the radiofrequency (RF) signals that underlie grayscale EUS images has been used to provide quantitative, objective information about tissue histology. OBJECTIVE: Our purpose was to validate RF spectral analysis as a method to distinguish between chronic pancreatitis (CP) and pancreatic cancer (PC). DESIGN AND SETTING: A prospective study of eligible patients was conducted to analyze the RF data obtained by using electronic array echoendoscopes. PATIENTS: Pancreatic images were obtained by using electronic array echoendoscopes from 41 patients in a prospective study, including 15 patients with PC, 15 with CP, and 11 with a normal pancreas. MAIN OUTCOME MEASUREMENTS: Midband fit, slope, intercept, correlation coefficient, and root mean square deviation from a linear regression of the calibrated power spectra were determined and compared among the groups. RESULTS: Statistical analysis showed that significant differences were observable between groups for mean midband fit, intercept, and root mean square deviation (t test, P < .05). Discriminant analysis of these parameters was then performed to classify the data. For CP (n = 15) versus PC (n = 15), the same parameters provided 83% accuracy and an area under the curve of 0.83. LIMITATIONS: Moderate sample size and spatial averaging inherent in the technique. CONCLUSIONS: This study shows that mean spectral parameters of the backscattered signals obtained by using electronic array echoendoscopes can provide a noninvasive method to quantitatively discriminate between CP and PC.


Assuntos
Endossonografia/métodos , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Pancreatite Crônica/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Análise Discriminante , Endossonografia/instrumentação , Feminino , Análise de Fourier , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Pâncreas/patologia , Neoplasias Pancreáticas/patologia , Pancreatite Crônica/patologia , Curva ROC
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA