Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Neurourol Urodyn ; 43(3): 646-654, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38314960

RESUMO

PURPOSE: Benign prostatic obstruction (BPO) is the most common cause of lower urinary tract symptoms among men. GreenLight photoselective vaporization of the prostate (GL-PVP) using a 180-W Xcelerated performance system (XPS) laser is a well-established method for treating BPO-induced voiding symptoms. However, its therapeutic effects on storage symptoms remain unclear. This study aimed to analyze the storage outcomes in patients who underwent 180-W XPS GL-PVP for BPO and to identify outcome predictors. MATERIALS AND METHODS: Patients who underwent 180-W XPS GL-PVP for BPO between May 2018 and May 2021 were retrospectively reviewed. Data on clinical characteristics, prostate volume, preoperative and postoperative International Prostate Symptom Scores (IPSS), and preoperative urodynamic parameters were collected. A favorable storage outcome was defined as ≥50% reduction in the IPSS storage subscore. RESULTS: Ninety-nine male patients were included, with a mean age of 69.4 ± 9.6 years and a baseline prostatic volume of 75.9 ± 33.1 mL. The IPSS total, storage, and voiding subscores significantly decreased after GL-PVP (all p < 0.001). Seventy-two patients achieved favorable storage outcome at 6 months. Multivariate analysis revealed that detrusor underactivity was predictive of unfavorable storage outcomes (p = 0.022), while IPSS voiding-to-storage subscore ratio >1.25 and the presence of detrusor overactivity were predictive of favorable storage outcomes (p = 0.008 and 0.033, respectively). CONCLUSION: 180-W XPS GL-PVP provided excellent outcomes in both voiding and storage lower urinary tract symptoms concomitant with BPO. Preoperative IPSS and multichannel urodynamic parameters including detrusor overactivity and underactivity are valuable predictors of postoperative storage outcomes.


Assuntos
Terapia a Laser , Sintomas do Trato Urinário Inferior , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Obstrução Uretral , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Próstata/cirurgia , Hiperplasia Prostática/complicações , Hiperplasia Prostática/cirurgia , Estudos Retrospectivos , Volatilização , Ressecção Transuretral da Próstata/efeitos adversos , Ressecção Transuretral da Próstata/métodos , Sintomas do Trato Urinário Inferior/cirurgia , Sintomas do Trato Urinário Inferior/complicações , Obstrução Uretral/complicações , Terapia a Laser/efeitos adversos , Terapia a Laser/métodos , Resultado do Tratamento
2.
Diagnostics (Basel) ; 14(2)2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38275470

RESUMO

We report an angiographic image of a 58-year-old woman with profuse bleeding from a tracheo-innominate artery fistula. It may not have been possible to obtain this valuable image if adequate initial resuscitation and an over-inflated tracheostomy tube cuff had not been administered to stop bleeding during an emergency.

3.
Adv Healthc Mater ; 12(24): e2300321, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37037493

RESUMO

Microneedle (MN) patches, which allow the extraction of skin interstitial fluid (ISF) without a pain sensation, are powerful tools for minimally invasive biofluid sampling. Herein, an MN-assisted paper-based sensing platform that enables rapid and painless biofluid analysis with ultrasensitive molecular recognition capacity is developed. First, a controllable-swelling MN patch is constructed through the engineering of a poly(ethylene glycol) diacrylate/methacrylated hyaluronic acid hydrogel; it combines rapid, sufficient extraction of ISF with excellent structural integrity. Notably, the analyte molecules in the needles can be recovered into a moist cellulose paper through spontaneous diffusion. More importantly, the paper can be functionalized with enzymatic colorimetric reagents or a plasmonic array, enabling a desired detection capacity-for example, the use of paper-based surface-enhanced Raman spectroscopy sensors leads to label-free, trace detection (sub-ppb level) of a diverse set of molecules (cefazolin, nicotine, paraquat, methylene blue). Finally, nicotine is selected as a model drug to evaluate the painless monitoring of three human volunteers. The changes in the nicotine levels can be tracked, with the levels varying significantly in response to the metabolism of drug in different volunteers. This as-designed minimally invasive sensing system should open up new opportunities for precision medicine, especially for personal healthcare monitoring.


Assuntos
Agulhas , Nicotina , Humanos , Pele/química , Líquido Extracelular/metabolismo , Celulose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA