Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
ArXiv ; 2024 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-39314505

RESUMO

PURPOSE: To develop and evaluate a new pulse sequence for highly accelerated distortion-free diffusion MRI (dMRI) by inserting an additional echo without prolonging TR, when generalized slice dithered enhanced resolution (gSlider) radiofrequency encoding is used for volumetric acquisition. METHODS: A phase-reversed interleaved multi-echo acquisition (PRIME) was developed for rapid, high-resolution, and distortion-free dMRI, which includes two echoes where the first echo is for target diffusion-weighted imaging (DWI) acquisition with high-resolution and the second echo is acquired with either 1) lower-resolution for high-fidelity field map estimation, or 2) matching resolution to enable efficient diffusion relaxometry acquisitions. The sequence was evaluated on in vivo data acquired from healthy volunteers on clinical and Connectome 2.0 scanners. RESULTS: In vivo experiments demonstrated that 1) high in-plane acceleration (Rin-plane of 5-fold with 2D partial Fourier) was achieved using the high-fidelity field maps estimated from the second echo, which was made at a lower resolution/acceleration to increase its SNR while matching the effective echo spacing of the first readout, 2) high-resolution diffusion relaxometry parameters were estimated from dual-echo PRIME data using a white matter model of multi-TE spherical mean technique (MTE-SMT), and 3) high-fidelity mesoscale DWI at 550 um isotropic resolution could be obtained in vivo by capitalizing on the high-performance gradients of the Connectome 2.0 scanner. CONCLUSION: The proposed PRIME sequence enabled highly accelerated, high-resolution, and distortion-free dMRI using an additional echo without prolonging scan time when gSlider encoding is utilized.

2.
Neuroinformatics ; 2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39312131

RESUMO

Advances in the spatiotemporal resolution and field-of-view of neuroimaging tools are driving mesoscale studies for translational neuroscience. On October 10, 2023, the Center for Mesoscale Mapping (CMM) at the Massachusetts General Hospital (MGH) Athinoula A. Martinos Center for Biomedical Imaging and the Massachusetts Institute of Technology (MIT) Health Sciences Technology based Neuroimaging Training Program (NTP) hosted a symposium exploring the state-of-the-art in this rapidly growing area of research. "Mesoscale Brain Mapping: Bridging Scales and Modalities in Neuroimaging" brought together researchers who use a broad range of imaging techniques to study brain structure and function at the convergence of the microscopic and macroscopic scales. The day-long event centered on areas in which the CMM has established expertise, including the development of emerging technologies and their application to clinical translational needs and basic neuroscience questions. The in-person symposium welcomed more than 150 attendees, including 57 faculty members, 61 postdoctoral fellows, 35 students, and four industry professionals, who represented institutions at the local, regional, and international levels. The symposium also served the training goals of both the CMM and the NTP. The event content, organization, and format were planned collaboratively by the faculty and trainees. Many CMM faculty presented or participated in a panel discussion, thus contributing to the dissemination of both the technologies they have developed under the auspices of the CMM and the findings they have obtained using those technologies. NTP trainees who benefited from the symposium included those who helped to organize the symposium and/or presented posters and gave "flash" oral presentations. In addition to gaining experience from presenting their work, they had opportunities throughout the day to engage in one-on-one discussions with visiting scientists and other faculty, potentially opening the door to future collaborations. The symposium presentations provided a deep exploration of the many technological advances enabling progress in structural and functional mesoscale brain imaging. Finally, students worked closely with the presenting faculty to develop this report summarizing the content of the symposium and putting it in the broader context of the current state of the field to share with the scientific community. We note that the references cited here include conference abstracts corresponding to the symposium poster presentations.

3.
Neuroimage ; : 120865, 2024 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-39349147

RESUMO

BACKGROUND: Three-dimensional (3D) T1-weighted MRI sequences such as the magnetization prepared rapid gradient echo (MPRAGE) sequence are important for assessing regional cortical atrophy in the clinical evaluation of dementia but have long acquisition times and are prone to motion artifact. The recently developed Scout Accelerated Motion Estimation and Reduction (SAMER) retrospective motion correction method addresses motion artifact within clinically-acceptable computation times and has been validated through qualitative evaluation in inpatient and emergency settings. METHODS: We evaluated the quantitative accuracy of morphometric analysis of SAMER motion-corrected compared to non-motion-corrected MPRAGE images by estimating cortical volume and thickness across neuroanatomical regions in two subject groups: (1) healthy volunteers and (2) patients undergoing evaluation for dementia. In part (1), we used a set of 108 MPRAGE reconstructed images derived from 12 healthy volunteers to systematically assess the effectiveness of SAMER in correcting varying degrees of motion corruption, ranging from mild to severe. In part (2), 29 patients who were scheduled for brain MRI with memory loss protocol and had motion corruption on their clinical MPRAGE scans were prospectively enrolled. RESULTS: In part (1), SAMER resulted in effective correction of motion-induced cortical volume and thickness reductions. We observed systematic increases in the estimated cortical volume and thickness across all neuroanatomical regions and a relative reduction in percent error values compared to reference standard scans of up to 66% for the cerebral white matter volume. In part (2), SAMER resulted in statistically significant volume increases across anatomical regions, with the most pronounced increases seen in the parietal and temporal lobes, and general reductions in percent error relative to reference standard clinical scans. CONCLUSION: SAMER improves the accuracy of morphometry through systematic increases and recovery of the estimated cortical volume and cortical thickness following motion correction, which may affect the evaluation of regional cortical atrophy in patients undergoing evaluation for dementia.

4.
Aging Cell ; : e14267, 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39118344

RESUMO

The human brain undergoes age-related microstructural alterations across the lifespan. Soma and Neurite Density Imaging (SANDI), a novel biophysical model of diffusion MRI, provides estimates of cell body (soma) radius and density, and neurite density in gray matter. The goal of this cross-sectional study was to assess the sensitivity of high-gradient diffusion MRI toward age-related alterations in cortical microstructure across the adult lifespan using SANDI. Seventy-two cognitively unimpaired healthy subjects (ages 19-85 years; 40 females) were scanned on the 3T Connectome MRI scanner with a maximum gradient strength of 300mT/m using a multi-shell diffusion MRI protocol incorporating 8 b-values and diffusion time of 19 ms. Intra-soma signal fraction obtained from SANDI model-fitting to the data was strongly correlated with age in all major cortical lobes (r = -0.69 to -0.60, FDR-p < 0.001). Intra-soma signal fraction (r = 0.48-0.63, FDR-p < 0.001) and soma radius (r = 0.28-0.40, FDR-p < 0.04) were significantly correlated with cortical volume in the prefrontal cortex, frontal, parietal, and temporal lobes. The strength of the relationship between SANDI metrics and age was greater than or comparable to the relationship between cortical volume and age across the cortical regions, particularly in the occipital lobe and anterior cingulate gyrus. In contrast to the SANDI metrics, all associations between diffusion tensor imaging (DTI) and diffusion kurtosis imaging metrics and age were low to moderate. These results suggest that high-gradient diffusion MRI may be more sensitive to underlying substrates of neurodegeneration in the aging brain than DTI and traditional macroscopic measures of neurodegeneration such as cortical volume and thickness.

5.
ArXiv ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-39010869

RESUMO

Axon diameter and myelin thickness are closely related microstructural tissue properties that affect the conduction velocity of action potentials in the nervous system. Imaging them non-invasively with MRI-based methods is thus valuable for studying brain microstructure and function. However, the relationship between MRI-based axon diameter and myelination measures has not been investigated across the brain, mainly due to methodological limitations in estimating axon diameters. In recent years, studies using ultra-high gradient strength diffusion MRI (dMRI) have demonstrated improved estimation of axon diameter across white-matter (WM) tracts in the human brain, making such investigations feasible. In this study, we aim to investigate relationships between tissue microstructure properties with MRI-based methods and compare the imaging findings to histological evidence from the literature. We collected dMRI with ultra-high gradient strength and multi-echo spin-echo MRI on ex vivo macaque and human brain samples on a preclinical scanner. From these data, we estimated axon diameter, intra-axonal signal fraction, myelin water fraction (MWF) and aggregate g-ratio and investigated their correlations. We found that the microstructural imaging parameters exhibited consistent patterns across WM tracts and species. Overall, the findings suggest that MRI-based axon geometry and myelination measures can provide complementary information about fiber morphology, and the relationships between these measures agree with prior histological evidence.

7.
Ann Clin Transl Neurol ; 11(6): 1405-1419, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38725151

RESUMO

OBJECTIVE: To evaluate the intrinsic and extrinsic microstructural factors contributing to atrophy within individual thalamic subregions in multiple sclerosis using in vivo high-gradient diffusion MRI. METHODS: In this cross-sectional study, 41 people with multiple sclerosis and 34 age and sex-matched healthy controls underwent 3T MRI with up to 300 mT/m gradients using a multi-shell diffusion protocol consisting of eight b-values and diffusion time of 19 ms. Each thalamus was parcellated into 25 subregions for volume determination and diffusion metric estimation. The soma and neurite density imaging model was applied to obtain estimates of intra-neurite, intra-soma, and extra-cellular signal fractions for each subregion and within structurally connected white matter trajectories and cortex. RESULTS: Multiple sclerosis-related volume loss was more pronounced in posterior/medial subregions than anterior/ventral subregions. Intra-soma signal fraction was lower in multiple sclerosis, reflecting reduced cell body density, while the extra-cellular signal fraction was higher, reflecting greater extra-cellular space, both of which were observed more in posterior/medial subregions than anterior/ventral subregions. Lower intra-neurite signal fraction in connected normal-appearing white matter and lower intra-soma signal fraction of structurally connected cortex were associated with reduced subregional thalamic volumes. Intrinsic and extrinsic microstructural measures independently related to subregional volume with heterogeneity across atrophy-prone thalamic nuclei. Extrinsic microstructural alterations predicted left anteroventral, intrinsic microstructural alterations predicted bilateral medial pulvinar, and both intrinsic and extrinsic factors predicted lateral geniculate and medial mediodorsal volumes. INTERPRETATION: Our results might be reflective of the involvement of anterograde and retrograde degeneration from white matter demyelination and cerebrospinal fluid-mediated damage in subregional thalamic volume loss.


Assuntos
Atrofia , Esclerose Múltipla , Tálamo , Humanos , Feminino , Masculino , Adulto , Tálamo/patologia , Tálamo/diagnóstico por imagem , Estudos Transversais , Pessoa de Meia-Idade , Esclerose Múltipla/patologia , Esclerose Múltipla/diagnóstico por imagem , Atrofia/patologia , Substância Branca/patologia , Substância Branca/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética
8.
Proc Natl Acad Sci U S A ; 121(19): e2313568121, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38648470

RESUMO

United States (US) Special Operations Forces (SOF) are frequently exposed to explosive blasts in training and combat, but the effects of repeated blast exposure (RBE) on SOF brain health are incompletely understood. Furthermore, there is no diagnostic test to detect brain injury from RBE. As a result, SOF personnel may experience cognitive, physical, and psychological symptoms for which the cause is never identified, and they may return to training or combat during a period of brain vulnerability. In 30 active-duty US SOF, we assessed the relationship between cumulative blast exposure and cognitive performance, psychological health, physical symptoms, blood proteomics, and neuroimaging measures (Connectome structural and diffusion MRI, 7 Tesla functional MRI, [11C]PBR28 translocator protein [TSPO] positron emission tomography [PET]-MRI, and [18F]MK6240 tau PET-MRI), adjusting for age, combat exposure, and blunt head trauma. Higher blast exposure was associated with increased cortical thickness in the left rostral anterior cingulate cortex (rACC), a finding that remained significant after multiple comparison correction. In uncorrected analyses, higher blast exposure was associated with worse health-related quality of life, decreased functional connectivity in the executive control network, decreased TSPO signal in the right rACC, and increased cortical thickness in the right rACC, right insula, and right medial orbitofrontal cortex-nodes of the executive control, salience, and default mode networks. These observations suggest that the rACC may be susceptible to blast overpressure and that a multimodal, network-based diagnostic approach has the potential to detect brain injury associated with RBE in active-duty SOF.


Assuntos
Traumatismos por Explosões , Militares , Humanos , Traumatismos por Explosões/diagnóstico por imagem , Adulto , Masculino , Estados Unidos , Imageamento por Ressonância Magnética , Feminino , Tomografia por Emissão de Pósitrons , Cognição/fisiologia , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Adulto Jovem
9.
Adv Sci (Weinh) ; 11(24): e2307965, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38634608

RESUMO

Diffusion magnetic resonance imaging is an important tool for mapping tissue microstructure and structural connectivity non-invasively in the in vivo human brain. Numerous diffusion signal models are proposed to quantify microstructural properties. Nonetheless, accurate estimation of model parameters is computationally expensive and impeded by image noise. Supervised deep learning-based estimation approaches exhibit efficiency and superior performance but require additional training data and may be not generalizable. A new DIffusion Model OptimizatioN framework using physics-informed and self-supervised Deep learning entitled "DIMOND" is proposed to address this problem. DIMOND employs a neural network to map input image data to model parameters and optimizes the network by minimizing the difference between the input acquired data and synthetic data generated via the diffusion model parametrized by network outputs. DIMOND produces accurate diffusion tensor imaging results and is generalizable across subjects and datasets. Moreover, DIMOND outperforms conventional methods for fitting sophisticated microstructural models including the kurtosis and NODDI model. Importantly, DIMOND reduces NODDI model fitting time from hours to minutes, or seconds by leveraging transfer learning. In summary, the self-supervised manner, high efficacy, and efficiency of DIMOND increase the practical feasibility and adoption of microstructure and connectivity mapping in clinical and neuroscientific applications.


Assuntos
Encéfalo , Aprendizado Profundo , Humanos , Encéfalo/diagnóstico por imagem , Imagem de Tensor de Difusão/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos
10.
bioRxiv ; 2024 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-38645264

RESUMO

Imaging the live human brain at the mesoscopic scale is a desideratum in basic and clinical neurosciences. Despite the promise of diffusion MRI, the lack of an accurate model relating the measured signal and the associated microstructure has hampered its success. The widely used diffusion tensor MRI (DTI) model assumes an anisotropic Gaussian diffusion process in each voxel, but lacks the ability to capture intravoxel heterogeneity. This study explores the extension of the DTI model to mesoscopic length scales by use of the diffusion tensor distribution (DTD) model, which assumes a Gaussian diffusion process in each subvoxel. DTD MRI has shown promise in addressing some limitations of DTI, particularly in distinguishing among different types of brain cancers and elucidating multiple fiber populations within a voxel. However, its validity in live brain tissue has never been established. Here, multiple diffusion-encoded (MDE) data were acquired in the living human brain using a 3 Tesla MRI scanner with large diffusion weighting factors. Two different diffusion times (Δ = 37, 74 ms) were employed, with other scanning parameters fixed to assess signal decay differences. In vivo diffusion-weighted signals in gray and white matter were nearly identical at the two diffusion times. Fitting the signals to the DTD model yielded indistinguishable results, except in the cerebrospinal fluid (CSF)-filled voxels likely due to pulsatile flow. Overall, the study supports the time invariance of water diffusion at the mesoscopic scale in live brain parenchyma, extending the validity of the anisotropic Gaussian diffusion model in clinical brain imaging.

11.
AJNR Am J Neuroradiol ; 45(4): 379-385, 2024 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-38453413

RESUMO

BACKGROUND AND PURPOSE: The use of MR imaging in emergency settings has been limited by availability, long scan times, and sensitivity to motion. This study assessed the diagnostic performance of an ultrafast brain MR imaging protocol for evaluation of acute intracranial pathology in the emergency department and inpatient settings. MATERIALS AND METHODS: Sixty-six adult patients who underwent brain MR imaging in the emergency department and inpatient settings were included in the study. All patients underwent both the reference and the ultrafast brain MR protocols. Both brain MR imaging protocols consisted of T1-weighted, T2/T2*-weighted, FLAIR, and DWI sequences. The ultrafast MR images were reconstructed by using a machine-learning assisted framework. All images were reviewed by 2 blinded neuroradiologists. RESULTS: The average acquisition time was 2.1 minutes for the ultrafast brain MR protocol and 10 minutes for the reference brain MR protocol. There was 98.5% agreement on the main clinical diagnosis between the 2 protocols. In head-to-head comparison, the reference protocol was preferred in terms of image noise and geometric distortion (P < .05 for both). The ultrafast ms-EPI protocol was preferred over the reference protocol in terms of reduced motion artifacts (P < .01). Overall diagnostic quality was not significantly different between the 2 protocols (P > .05). CONCLUSIONS: The ultrafast brain MR imaging protocol provides high accuracy for evaluating acute pathology while only requiring a fraction of the scan time. Although there was greater image noise and geometric distortion on the ultrafast brain MR protocol images, there was significant reduction in motion artifacts with similar overall diagnostic quality between the 2 protocols.


Assuntos
Encefalopatias , Pacientes Internados , Adulto , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Encefalopatias/diagnóstico por imagem , Encefalopatias/patologia , Tempo
12.
Neurobiol Aging ; 136: 157-170, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38382159

RESUMO

Recent efforts demonstrated the efficacy of identifying early-stage neuropathology of Alzheimer's disease (AD) through lumbar puncture cerebrospinal fluid assessment and positron emission tomography (PET) radiotracer imaging. These methods are effective yet are invasive, expensive, and not widely accessible. We extend and improve the multiscale structural mapping (MSSM) procedure to develop structural indicators of ß-amyloid neuropathology in preclinical AD, by capturing both macrostructural and microstructural properties throughout the cerebral cortex using a structural MRI. We find that the MSSM signal is regionally altered in clear positive and negative cases of preclinical amyloid pathology (N = 220) when cortical thickness alone or hippocampal volume is not. It exhibits widespread effects of amyloid positivity across the posterior temporal, parietal, and medial prefrontal cortex, surprisingly consistent with the typical pattern of amyloid deposition. The MSSM signal is significantly correlated with amyloid PET in almost half of the cortex, much of which overlaps with regions where beta-amyloid accumulates, suggesting it could provide a regional brain 'map' that is not available from systemic markers such as plasma markers.


Assuntos
Doença de Alzheimer , Peptídeos beta-Amiloides , Humanos , Peptídeos beta-Amiloides/metabolismo , Encéfalo/metabolismo , Doença de Alzheimer/patologia , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos , Amiloide/metabolismo
13.
bioRxiv ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38352481

RESUMO

Purpose: To overcome the major challenges in dMRI acquisition, including low SNR, distortion/blurring, and motion vulnerability. Methods: A novel Romer-EPTI technique is developed to provide distortion-free dMRI with significant SNR gain, high motion-robustness, sharp spatial resolution, and simultaneous multi-TE imaging. It introduces a ROtating-view Motion-robust supEr-Resolution technique (Romer) combined with a distortion/blurring-free EPTI encoding. Romer enhances SNR by a simultaneous multi-thick-slice acquisition with rotating-view encoding, while providing high motion-robustness through a motion-aware super-resolution reconstruction, which also incorporates slice-profile and real-value diffusion, to resolve high-isotropic-resolution volumes. The in-plane encoding is performed using distortion/blurring-free EPTI, which further improves effective spatial resolution and motion robustness by preventing not only T2/T2*-blurring but also additional blurring resulting from combining encoded volumes with inconsistent geometries caused by dynamic distortions. Self-navigation was incorporated to enable efficient phase correction. Additional developments include strategies to address slab-boundary artifacts, achieve minimal TE for SNR gain at 7T, and achieve high robustness to strong phase variations at high b-values. Results: Using Romer-EPTI, we demonstrate distortion-free whole-brain mesoscale in-vivo dMRI at both 3T (500-µm-iso) and 7T (485-µm-iso) for the first time, with high SNR efficiency (e.g., 25×), and high image quality free from distortion and slab-boundary artifacts with minimal blurring. Motion experiments demonstrate Romer-EPTI's high motion-robustness and ability to recover sharp images in the presence of motion. Romer-EPTI also demonstrates significant SNR gain and robustness in high b-value (b=5000s/mm2) and time-dependent dMRI. Conclusion: Romer-EPTI significantly improves SNR, motion-robustness, and image quality, providing a highly efficient acquisition for high-resolution dMRI and microstructure imaging.

14.
Neuroradiol J ; 37(3): 323-331, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38195418

RESUMO

BACKGROUND AND PURPOSE: Deep learning (DL) accelerated MR techniques have emerged as a promising approach to accelerate routine MR exams. While prior studies explored DL acceleration for specific lumbar MRI sequences, a gap remains in comprehending the impact of a fully DL-based MRI protocol on scan time and diagnostic quality for routine lumbar spine MRI. To address this, we assessed the image quality and diagnostic performance of a DL-accelerated lumbar spine MRI protocol in comparison to a conventional protocol. METHODS: We prospectively evaluated 36 consecutive outpatients undergoing non-contrast enhanced lumbar spine MRIs. Both protocols included sagittal T1, T2, STIR, and axial T2-weighted images. Two blinded neuroradiologists independently reviewed images for foraminal stenosis, spinal canal stenosis, nerve root compression, and facet arthropathy. Grading comparison employed the Wilcoxon signed rank test. For the head-to-head comparison, a 5-point Likert scale to assess image quality, considering artifacts, signal-to-noise ratio (SNR), anatomical structure visualization, and overall diagnostic quality. We applied a 15% noninferiority margin to determine whether the DL-accelerated protocol was noninferior. RESULTS: No significant differences existed between protocols when evaluating foraminal and spinal canal stenosis, nerve compression, or facet arthropathy (all p > .05). The DL-spine protocol was noninferior for overall diagnostic quality and visualization of the cord, CSF, intervertebral disc, and nerve roots. However, it exhibited reduced SNR and increased artifact perception. Interobserver reproducibility ranged from moderate to substantial (κ = 0.50-0.76). CONCLUSION: Our study indicates that DL reconstruction in spine imaging effectively reduces acquisition times while maintaining comparable diagnostic quality to conventional MRI.


Assuntos
Aprendizado Profundo , Vértebras Lombares , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Vértebras Lombares/diagnóstico por imagem , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Razão Sinal-Ruído , Estenose Espinal/diagnóstico por imagem , Adulto , Doenças da Coluna Vertebral/diagnóstico por imagem
15.
NMR Biomed ; 37(4): e5087, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38168082

RESUMO

The increasing availability of high-performance gradient systems in human MRI scanners has generated great interest in diffusion microstructural imaging applications such as axonal diameter mapping. Practically, sensitivity to axon diameter in diffusion MRI is attained at strong diffusion weightings b , where the deviation from the expected 1 / b scaling in white matter yields a finite transverse diffusivity, which is then translated into an axon diameter estimate. While axons are usually modeled as perfectly straight, impermeable cylinders, local variations in diameter (caliber variation or beading) and direction (undulation) are known to influence axonal diameter estimates and have been observed in microscopy data of human axons. In this study, we performed Monte Carlo simulations of diffusion in axons reconstructed from three-dimensional electron microscopy of a human temporal lobe specimen using simulated sequence parameters matched to the maximal gradient strength of the next-generation Connectome 2.0 human MRI scanner ( ≲ 500 mT/m). We show that axon diameter estimation is accurate for nonbeaded, nonundulating fibers; however, in fibers with caliber variations and undulations, the axon diameter is heavily underestimated due to caliber variations, and this effect overshadows the known overestimation of the axon diameter due to undulations. This unexpected underestimation may originate from variations in the coarse-grained axial diffusivity due to caliber variations. Given that increased axonal beading and undulations have been observed in pathological tissues, such as traumatic brain injury and ischemia, the interpretation of axon diameter alterations in pathology may be significantly confounded.


Assuntos
Imagem de Difusão por Ressonância Magnética , Substância Branca , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Axônios/patologia , Imageamento por Ressonância Magnética , Microscopia Eletrônica
16.
Acad Radiol ; 31(4): 1572-1582, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37951777

RESUMO

RATIONALE AND OBJECTIVES: Brain tumor segmentations are integral to the clinical management of patients with glioblastoma, the deadliest primary brain tumor in adults. The manual delineation of tumors is time-consuming and highly provider-dependent. These two problems must be addressed by introducing automated, deep-learning-based segmentation tools. This study aimed to identify criteria experts use to evaluate the quality of automatically generated segmentations and their thought processes as they correct them. MATERIALS AND METHODS: Multiple methods were used to develop a detailed understanding of the complex factors that shape experts' perception of segmentation quality and their thought processes in correcting proposed segmentations. Data from a questionnaire and semistructured interview with neuro-oncologists and neuroradiologists were collected between August and December 2021 and analyzed using a combined deductive and inductive approach. RESULTS: Brain tumors are highly complex and ambiguous segmentation targets. Therefore, physicians rely heavily on the given context related to the patient and clinical context in evaluating the quality and need to correct brain tumor segmentation. Most importantly, the intended clinical application determines the segmentation quality criteria and editing decisions. Physicians' personal beliefs and preferences about the capabilities of AI algorithms and whether questionable areas should not be included are additional criteria influencing the perception of segmentation quality and appearance of an edited segmentation. CONCLUSION: Our findings on experts' perceptions of segmentation quality will allow the design of improved frameworks for expert-centered evaluation of brain tumor segmentation models. In particular, the knowledge presented here can inspire the development of brain tumor-specific metrics for segmentation model training and evaluation.


Assuntos
Neoplasias Encefálicas , Glioblastoma , Adulto , Humanos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Algoritmos , Glioblastoma/patologia , Reconhecimento Automatizado de Padrão/métodos , Carga Tumoral , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos
17.
Magn Reson Med ; 91(2): 541-557, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37753621

RESUMO

PURPOSE: To investigate whether spatiotemporal magnetic field monitoring can correct pronounced eddy current-induced artifacts incurred by strong diffusion-sensitizing gradients up to 300 mT/m used in high b-value diffusion-weighted (DW) EPI. METHODS: A dynamic field camera equipped with 16 1 H NMR field probes was first used to characterize field perturbations caused by residual eddy currents from diffusion gradients waveforms in a 3D multi-shot EPI sequence on a 3T Connectom scanner for different gradient strengths (up to 300 mT/m), diffusion directions, and shots. The efficacy of dynamic field monitoring-based image reconstruction was demonstrated on high-gradient strength, submillimeter resolution whole-brain ex vivo diffusion MRI. A 3D multi-shot image reconstruction framework was developed that incorporated the nonlinear phase evolution measured with the dynamic field camera. RESULTS: Phase perturbations in the readout induced by residual eddy currents from strong diffusion gradients are highly nonlinear in space and time, vary among diffusion directions, and interfere significantly with the image encoding gradients, changing the k-space trajectory. During the readout, phase modulations between odd and even EPI echoes become non-static and diffusion encoding direction-dependent. Superior reduction of ghosting and geometric distortion was achieved with dynamic field monitoring compared to ghosting reduction approaches such as navigator- and structured low-rank-based methods or MUSE followed by image-based distortion correction with the FSL tool "eddy." CONCLUSION: Strong eddy current artifacts characteristic of high-gradient strength DW-EPI can be well corrected with dynamic field monitoring-based image reconstruction.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imagem Ecoplanar/métodos
18.
J Cereb Blood Flow Metab ; : 271678X231216144, 2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38000018

RESUMO

Cerebrovascular dysfunction is a significant contributor to Alzheimer's disease (AD) progression. AD mouse models show altered capillary morphology, density, and diminished blood flow in areas of tau and beta-amyloid accumulation. The purpose of this study was to examine alterations in vascular structure and their contributions to perfusion deficits in the hippocampus in AD and mild cognitive impairment (MCI). Seven individuals with AD and MCI (1 AD/6 MCI), nine cognitively intact older healthy adults, and seven younger healthy adults underwent pseudo-continuous arterial spin labeling (PCASL) and gradient-echo/spin-echo (GESE) dynamic susceptibility contrast (DSC) MRI. Cerebral blood flow (CBF), cerebral blood volume, relative vessel size index (rVSI), and mean vessel density were calculated from model fitting. Lower CBF from PCASL and SE DSC MRI was observed in the hippocampus of AD/MCI group. rVSI in the hippocampus of the AD/MCI group was larger than that of the two healthy groups (FDR-P = 0.02). No difference in vessel density was detected between the groups. We also explored relationship of tau burden from 18F-flortaucipir positron emission tomography and vascular measures from MRI. Tau burden was associated with larger vessel size and lower CBF in the hippocampus. We postulate that larger vessel size may be associated with vascular alterations in AD/MCI.

19.
J Spec Oper Med ; 23(4): 47-56, 2023 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-37851859

RESUMO

United States Special Operations Forces (SOF) personnel are frequently exposed to explosive blasts in training and combat. However, the effects of repeated blast exposure on the human brain are incompletely understood. Moreover, there is currently no diagnostic test to detect repeated blast brain injury (rBBI). In this "Human Performance Optimization" article, we discuss how the development and implementation of a reliable diagnostic test for rBBI has the potential to promote SOF brain health, combat readiness, and quality of life.


Assuntos
Traumatismos por Explosões , Militares , Humanos , Estados Unidos , Qualidade de Vida , Encéfalo/diagnóstico por imagem , Traumatismos por Explosões/diagnóstico , Traumatismos por Explosões/terapia , Explosões
20.
J Headache Pain ; 24(1): 113, 2023 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-37596546

RESUMO

BACKGROUND: There is a clinical association between migraine and multiple sclerosis. MAIN BODY: Migraine and MS patients share similar demographics, with the highest incidence among young, female and otherwise healthy patients. The same hormonal constellations/changes trigger disease exacerbation in both entities. Migraine prevalence is increased in MS patients, which is further enhanced by disease-modifying treatment. Clinical data show that onset of migraine typically starts years before the clinical diagnosis of MS, suggesting that there is either a unidirectional relationship with migraine predisposing to MS, and/or a "shared factor" underlying both conditions. Brain imaging studies show white matter lesions in both MS and migraine patients. Neuroinflammatory mechanisms likely play a key role, at least as a shared downstream pathway. In this review article, we provide an overview of the literature about 1) the clinical association between migraine and MS as well as 2) brain MRI studies that help us better understand the mechanistic relationship between both diseases with implications on their underlying pathophysiology. CONCLUSION: Studies suggest a migraine history predisposes patients to develop MS. Advanced brain MR imaging may shed light on shared and distinct features, while helping us better understand mechanisms underlying both disease entities.


Assuntos
Transtornos de Enxaqueca , Esclerose Múltipla , Humanos , Feminino , Esclerose Múltipla/complicações , Esclerose Múltipla/diagnóstico por imagem , Neuroimagem , Imageamento por Ressonância Magnética , Transtornos de Enxaqueca/diagnóstico por imagem , Encéfalo/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA