Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Med Sci Sports Exerc ; 56(3): 545-552, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37847102

RESUMO

PURPOSE: This study aimed to evaluate patellar tendon loading profiles (loading index, based on loading peak, loading impulse, and loading rate) of rehabilitation exercises to develop clinical guidelines to incrementally increase the rate and magnitude of patellar tendon loading during rehabilitation. METHODS: Twenty healthy adults (10 females/10 males, 25.9 ± 5.7 yr) performed 35 rehabilitation exercises, including different variations of squats, lunge, jumps, hops, landings, running, and sports specific tasks. Kinematic and kinetic data were collected, and a patellar tendon loading index was determined for each exercise using a weighted sum of loading peak, loading rate, and cumulative loading impulse. Then the exercises were ranked, according to the loading index, into tier 1 (loading index ≤0.33), tier 2 (0.33 < loading index <0.66), and tier 3 (loading index ≥0.66). RESULTS: The single-leg decline squat showed the highest loading index (0.747). Other tier 3 exercises included single-leg forward hop (0.666), single-leg countermovement jump (0.711), and running cut (0.725). The Spanish squat was categorized as a tier 2 exercise (0.563), as was running (0.612), double-leg countermovement jump (0.610), single-leg drop vertical jump (0.599), single-leg full squat (0.580), double-leg drop vertical jump (0.563), lunge (0.471), double-leg full squat (0.428), single-leg 60° squat (0.411), and Bulgarian squat (0.406). Tier 1 exercises included 20 cm step up (0.187), 20 cm step down (0.288), 30 cm step up (0.321), and double-leg 60° squat (0.224). CONCLUSIONS: Three patellar tendon loading tiers were established based on a combination of loading peak, loading impulse, and loading rate. Clinicians may use these loading tiers as a guide to progressively increase patellar tendon loading during the rehabilitation of patients with patellar tendon disorders and after anterior cruciate ligament reconstruction using the bone-patellar tendon-bone graft.


Assuntos
Lesões do Ligamento Cruzado Anterior , Ligamento Patelar , Traumatismos dos Tendões , Masculino , Adulto , Feminino , Humanos , Terapia por Exercício , Exercício Físico , Postura
2.
Sci Rep ; 13(1): 18086, 2023 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-37872320

RESUMO

The purpose of this study is to develop a wearable paradigm to accurately monitor Achilles tendon loading and walking speed using wearable sensors that reduce subject burden. Ten healthy adults walked in an immobilizing boot under various heel wedge conditions (30°, 5°, 0°) and walking speeds. Three-dimensional motion capture, ground reaction force, and 6-axis inertial measurement unit (IMU) signals were collected. We used a Least Absolute Shrinkage and Selection Operator (LASSO) regression to predict peak Achilles tendon load and walking speed. The effects of altering sensor parameters were also explored. Walking speed models (mean absolute percentage error (MAPE): 8.81 ± 4.29%) outperformed tendon load models (MAPE: 34.93 ± 26.3%). Models trained with subject-specific data performed better than models trained without subject-specific data. Removing the gyroscope, decreasing the sampling frequency, and using combinations of sensors did not change the usability of the models, having inconsequential effects on model performance. We developed a simple monitoring paradigm that uses LASSO regression and wearable sensors to accurately predict (MAPE ≤ 12.6%) Achilles tendon loading and walking speed while ambulating in an immobilizing boot. This paradigm provides a clinically implementable strategy to longitudinally monitor patient loading and activity while recovering from Achilles tendon injuries.


Assuntos
Tendão do Calcâneo , Dispositivos Eletrônicos Vestíveis , Adulto , Humanos , Velocidade de Caminhada , Caminhada , Aprendizado de Máquina , Fenômenos Biomecânicos , Marcha
3.
J Biomech ; 157: 111751, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37552921

RESUMO

Motion analysis is essential for assessing in-vivo human biomechanics. Marker-based motion capture is the standard to analyze human motion, but the inherent inaccuracy and practical challenges limit its utility in large-scale and real-world applications. Markerless motion capture has shown promise to overcome these practical barriers. However, its fidelity in quantifying joint kinematics and kinetics has not been verified across multiple common human movements. In this study, we concurrently captured marker-based and markerless motion data on 10 healthy study participants performing 8 daily living and exercise movements. We calculated the correlation (Rxy) and root-mean-square difference (RMSD) between markerless and marker-based estimates of ankle dorsi-plantarflexion, knee flexion, and three-dimensional hip kinematics (angles) and kinetics (moments) during each movement. Estimates from markerless motion capture matched closely with marker-based in ankle and knee joint angles (Rxy ≥ 0.877, RMSD ≤ 5.9°) and moments (Rxy ≥ 0.934, RMSD ≤ 2.66 % height × weight). High outcome comparability means the practical benefits of markerless motion capture can simplify experiments and facilitate large-scale analyses. Hip angles and moments demonstrated more differences between the two systems (RMSD: 6.7-15.9° and up to 7.15 % height × weight), especially during rapid movements such as running. Markerless motion capture appears to improve the accuracy of hip-related measures, yet more research is needed for validation. We encourage the biomechanics community to continue verifying, validating, and establishing best practices for markerless motion capture, which holds exciting potential to advance collaborative biomechanical research and expand real-world assessments needed for clinical translation.


Assuntos
Extremidade Inferior , Captura de Movimento , Humanos , Fenômenos Biomecânicos , Cinética , Movimento , Movimento (Física) , Articulação do Joelho
4.
medRxiv ; 2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37333069

RESUMO

Achilles tendon injuries are treated with progressive weight bearing to promote tendon healing and restore function. Patient rehabilitation progression are typically studied in controlled, lab settings and do not represent the long-term loading experienced during daily living. The purpose of this study is to develop a wearable paradigm to accurately monitor Achilles tendon loading and walking speed using low-cost sensors that reduce subject burden. Ten healthy adults walked in an immobilizing boot under various heel wedge conditions (30°, 5°, 0°) and walking speeds. Three-dimensional motion capture, ground reaction force, and 6-axis inertial measurement unit (IMU) signals were collected per trial. We used Least Absolute Shrinkage and Selection Operator (LASSO) regression to predict peak Achilles tendon load and walking speed. The effects of using only accelerometer data, different sampling frequency, and multiple sensors to train the model were also explored. Walking speed models outperformed (mean absolute percentage error (MAPE): 8.41 ± 4.08%) tendon load models (MAPE: 33.93 ± 23.9%). Models trained with subject-specific data performed significantly better than generalized models. For example, our personalized model that was trained with only subject-specific data predicted tendon load with a 11.5 ± 4.41% MAPE and walking speed with a 4.50 ± 0.91% MAPE. Removing gyroscope channels, decreasing sampling frequency, and using combinations of sensors had inconsequential effects on models performance (changes in MAPE < 6.09%). We developed a simple monitoring paradigm that uses LASSO regression and wearable sensors to accurately predict Achilles tendon loading and walking speed while ambulating in an immobilizing boot. This paradigm provides a clinically implementable strategy to longitudinally monitor patient loading and activity while recovering from Achilles tendon injuries.

5.
Am J Sports Med ; 51(8): 2110-2119, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37272685

RESUMO

BACKGROUND: Exercises that provide progressive therapeutic loading are a central component of patellofemoral pain rehabilitation, but quantitative evidence on patellofemoral joint loading is scarce for a majority of common weightbearing rehabilitation exercises. PURPOSE: To define a loading index to quantify, compare, rank, and categorize overall loading levels in the patellofemoral joint across 35 types of weightbearing rehabilitation exercises and activities of daily living. STUDY DESIGN: Descriptive laboratory study. METHODS: Model-estimated knee flexion angles and extension moments based on motion capture and ground-reaction force data were used to quantify patellofemoral joint loading in 20 healthy participants who performed each exercise. A loading index was computed via a weighted sum of loading peak and cumulative loading impulse for each exercise. The 35 rehabilitation exercises and daily living activities were then ranked and categorized into low, moderate, and high "loading tiers" according to the loading index. RESULTS: Overall patellofemoral loading levels varied substantially across the exercises and activities, with loading peak ranging from 0.6 times body weight during walking to 8.2 times body weight during single-leg decline squat. Most rehabilitation exercises generated a moderate level of patellofemoral joint loading. Few weightbearing exercises provided low-level loading that resembled walking or high-level loading with both high magnitude and duration. Exercises with high knee flexion tended to generate higher patellofemoral joint loading compared with high-intensity exercises. CONCLUSION: This study quantified patellofemoral joint loading across a large collection of weightbearing exercises in the same cohort. CLINICAL RELEVANCE: The visualized loading index ranks and modifiable worksheet may assist clinicians in planning patient-specific exercise programs for patellofemoral pain rehabilitation.


Assuntos
Articulação Patelofemoral , Síndrome da Dor Patelofemoral , Humanos , Atividades Cotidianas , Fenômenos Biomecânicos , Terapia por Exercício , Suporte de Carga , Peso Corporal , Articulação do Joelho
6.
bioRxiv ; 2023 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-36865211

RESUMO

Motion analysis is essential for assessing in-vivo human biomechanics. Marker-based motion capture is the standard to analyze human motion, but the inherent inaccuracy and practical challenges limit its utility in large-scale and real-world applications. Markerless motion capture has shown promise to overcome these practical barriers. However, its fidelity in quantifying joint kinematics and kinetics has not been verified across multiple common human movements. In this study, we concurrently captured marker-based and markerless motion data on 10 healthy subjects performing 8 daily living and exercise movements. We calculated the correlation (R xy ) and root-mean-square difference (RMSD) between markerless and marker-based estimates of ankle dorsi-plantarflexion, knee flexion, and three-dimensional hip kinematics (angles) and kinetics (moments) during each movement. Estimates from markerless motion capture matched closely with marker-based in ankle and knee joint angles (R xy ≥ 0.877, RMSD ≤ 5.9°) and moments (R xy ≥ 0.934, RMSD ≤ 2.66 % height × weight). High outcome comparability means the practical benefits of markerless motion capture can simplify experiments and facilitate large-scale analyses. Hip angles and moments demonstrated more differences between the two systems (RMSD: 6.7° - 15.9° and up to 7.15 % height × weight), especially during rapid movements such as running. Markerless motion capture appears to improve the accuracy of hip-related measures, yet more research is needed for validation. We encourage the biomechanics community to continue verifying, validating, and establishing best practices for markerless motion capture, which holds exciting potential to advance collaborative biomechanical research and expand real-world assessments needed for clinical translation.

7.
J Biomech ; 127: 110688, 2021 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-34461365

RESUMO

Researchers often estimate joint loading using musculoskeletal models to solve the inverse dynamics problem. This approach is powerful because it can be done non-invasively, however, it relies on assumptions and physical measurements that are prone to measurement error. The purpose of this study was to determine the impact of these errors - specifically, segment mass and shear ground reaction force - have on analyzing joint loads during activities of daily living. We performed traditional marker-based motion capture analysis on 8 healthy adults while they completed a battery of exercises on 6 degree of freedom force plates. We then scaled the mass of each segment as well as the shear component of the ground reaction force in 5% increments between 0 and 200% and iteratively performed inverse dynamics calculations, resulting in 1681 mass-shear combinations per activity. We compared the peak joint moments of the ankle, knee, and hip at each mass-shear combination to the 100% mass and 100% shear combination to determine the percent error. We found that the ankle was most resistant to changes in both mass and shear and the knee was resistant to changes in mass while the hip was sensitive to changes in both mass and shear. These results can help guide researchers who are pursuing lower-cost or more convenient data collection setups.


Assuntos
Atividades Cotidianas , Extremidade Inferior , Adulto , Articulação do Tornozelo , Fenômenos Biomecânicos , Articulação do Quadril , Humanos , Articulação do Joelho
8.
J Biomech ; 125: 110547, 2021 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-34175570

RESUMO

Markerless motion capture using deep learning approaches have potential to revolutionize the field of biomechanics by allowing researchers to collect data outside of the laboratory environment, yet there remain questions regarding the accuracy and ease of use of these approaches. The purpose of this study was to apply a markerless motion capture approach to extract lower limb angles in the sagittal plane during the vertical jump and to evaluate agreement between the custom trained model and gold standard motion capture. We performed this study using a large open source data set (N = 84) that included synchronized commercial video and gold standard motion capture. We split these data into a training set for model development (n = 69) and test set to evaluate capture performance relative to gold standard motion capture using coefficient of multiple correlations (CMC) (n = 15). We found very strong agreement between the custom trained markerless approach and marker-based motion capture within the test set across the entire movement (CMC > 0.991, RMSE < 3.22°), with at least strong CMC values across all trials for the hip (0.853 ± 0.23), knee (0.963 ± 0.471), and ankle (0.970 ± 0.055). The strong agreement between markerless and marker-based motion capture provides evidence that markerless motion capture is a viable tool to extend data collection to outside of the laboratory. As biomechanical research struggles with representative sampling practices, markerless motion capture has potential to transform biomechanical research away from traditional laboratory settings into venues convenient to populations that are under sampled without sacrificing measurement fidelity.


Assuntos
Articulação do Tornozelo , Laboratórios , Fenômenos Biomecânicos , Articulação do Joelho , Movimento (Física)
9.
Med Sci Sports Exerc ; 53(1): 124-130, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32658037

RESUMO

PURPOSE: The purposes of our study were to evaluate Achilles tendon loading profiles of various exercises and to develop guidelines to incrementally increase the rate and magnitude of Achilles tendon loading during rehabilitation. METHODS: Eight healthy young adults completed a battery of rehabilitation exercises. During each exercise, we collected three-dimensional motion capture and ground reaction force data to estimate Achilles tendon loading biomechanics. Using these loading estimates, we developed an exercise progression that incrementally increases Achilles tendon loading based on the magnitude, duration, and rate of tendon loading. RESULTS: We found that Achilles tendon loading could be incrementally increased using a set of either isolated ankle movements or multijoint movements. Peak Achilles tendon loads varied more than 12-fold, from 0.5 bodyweights during a seated heel raise to 7.3 bodyweights during a forward single-leg hop. Asymmetric stepping movements like lunges, step ups, and step downs provide additional flexibility for prescribing tendon loading on a side-specific manner. CONCLUSION: By establishing progressions for Achilles tendon loading, rehabilitative care can be tailored to address the specific needs of each patient. Our comprehensive data set also provides clinicians and researchers guidelines on how to alter magnitude, duration, and rate of loading to design new exercises and exercise progressions based on the clinical need.


Assuntos
Tendão do Calcâneo/fisiologia , Terapia por Exercício/métodos , Exercício Físico/fisiologia , Suporte de Carga , Tendão do Calcâneo/lesões , Adulto , Articulação do Tornozelo/fisiologia , Fenômenos Biomecânicos , Feminino , Humanos , Extremidade Inferior/fisiologia , Masculino , Estudos de Tempo e Movimento
10.
J Biomech ; 111: 110015, 2020 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-32891810

RESUMO

Isokinetic dynamometers are the gold standard tools used to assess in vivo joint and muscle function in human subjects, however, the large size and high cost of these devices prevents their widespread use outside of traditonal biomechanics labs. In this study, we developed a mobile dynamometer to allow for field measurements of joint level function. To ensure subject safety, we designed a new "isodamping" dynamometer that acted as passive energy sink which constrains velocity by forcing incompressible oil through an orifice with an adjustable diameter. We validated the performance of this device by testing plantar flexor function in six healthy adults on both a commercial isokinetic dynamometer and this novel device at three velocities/damper settings and at three different effort levels. During maximal effort contraction, measurements of peak moment and velocity at peak moment of the novel device and the commercial device were strongly correlated along the predicted quadratic line (R2 > 0.708, p ≤ 0.008). The setting of the damper prescribed the relationship between peak moment and velocity at peak moment across all subjects and effort levels (R2 > 0.910, p < 0.001). The novel device was significantly smaller (0.75 m2 footprint), lighter (30 kg), and lower cost (~$2,200 US Dollars) than commercial devices compared to commercially-available isokinetic dynamometers (5.95 m2 footprint, 450 kg, and ~$40,000 US Dollars respectively).


Assuntos
Articulação do Tornozelo , Contração Isométrica , Adulto , Fenômenos Biomecânicos , Terapia por Exercício , Humanos , Movimento , Músculo Esquelético
11.
J Biomech ; 109: 109925, 2020 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-32807329

RESUMO

Achilles tendon ruptures are common injuries that lead to functional deficits in two-thirds of patients. Progressively loading the healing tendon has been associated with superior outcomes, but the loading profiles that patients experience throughout rehabilitation have not yet been established. In this study, we developed and calibrated an instrumented immobilizing boot paradigm that is aimed at longitudinally quantifying patient loading biomechanics to develop personalized rehabilitation protocols. We used a 3-part instrumented insole to quantify the ankle loads generated by the Achilles tendon and secured a load cell inline with the posterior strut of the immobilizing boot to quantify boot loading. We then collected gait data from five healthy young adults to demonstrate the validity of this instrumented immobilizing boot paradigm to assess Achilles tendon loading during ambulation. We developed a simple calibration procedure to improve the measurement fidelity of the instrumented insole needed to quantify Achilles tendon loading while ambulating with an immobilizing boot. By assessing Achilles tendon loading with the ankle constrained to 0 degrees and 30 degrees plantar flexion, we confirmed that walking with the foot supported in plantar flexion decreased Achilles tendon loading by 60% (P < 0.001). This instrumented immobilizing boot paradigm leverages commercially available sensors and logs data using a small microcontroller secured to the boot and a handheld device, making our paradigm capable of continuously monitoring biomechanical loading outside of the lab or clinic.


Assuntos
Tendão do Calcâneo , Traumatismos dos Tendões , , Marcha , Humanos , Ruptura , Caminhada , Adulto Jovem
12.
Gait Posture ; 79: 92-95, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32388057

RESUMO

BACKGROUND: Plantar flexion is critical for ambulatory function but there are few wearable solutions to monitor loading. RESEARCH QUESTION: The purpose of this study was to develop and validate a method to calculate plantar flexion moment using a commercially-available instrumented insole. METHODS: Seven healthy young adults completed a battery of functional activities to characterize a range of plantar flexion loading which included single leg heel raise, step down, and drop jump as well as walking and running at comfortable speeds. Lower extremity trajectories were captured using motion capture and ground reaction forces were recorded with embedded force plates as well as the instrumented insole. We compared plantar flexion moment calculated by the instrumented insole to 'gold standard' inverse dynamics. RESULTS: We found that estimating plantar flexion moment using our instrumented insole algorithm compared favorably to moments calculated using inverse dynamics across all activities. Errors in the maximum plantar flexion moments were less than 10 % for all activities, averaging 4.9 %. Root mean square errors across the entire activity were also small, averaging 1.0 % bodyweight * height. Additionally, the calculated wave forms were strongly correlated with inverse dynamics (Rxy > 0.964). SIGNIFICANCE: Our findings demonstrate the utility and fidelity of a simple method for estimating plantar flexion moment using a commercially available instrumented insole. By leveraging this simple methodology, it is now feasible to prospectively track and eventually prescribe plantar flexion loading outside of the clinic to improve patient outcomes.


Assuntos
Algoritmos , Placa Plantar/fisiopatologia , Amplitude de Movimento Articular , Sapatos , Caminhada , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
13.
J Biomech ; 105: 109784, 2020 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-32278525

RESUMO

Achilles tendon disorders are among the most difficult sports-related injuries to predict with current diagnostic tools. The purpose of this study was to identify a clinically useful marker for early tendon damage. We hypothesized that alterations in mean echogenicity are linked with changes in vitro tendon mechanics. To test our hypothesis, we harvested Achilles tendons from 10 fresh-frozen cadaveric feet and cyclically fatigued them using a universal test frame while we continuously acquired ultrasound images. Throughout this fatigue protocol, we applied 2 stress tests every 500 loading cycles to quantify changes in ultrasound imaging echogenicity. We continued this fatigue protocol until each tendon either failed completely or survived 150,000 cycles. Tendons that failed during the fatigue loading (6/10) underwent greater changes in mean echogenicity compared to tendons that did not fail (P = 0.031). These tendons that failed during fatigue loading demonstrated greater changes in mean echogenicity that surpassed 1.0%; whereas survivor tendons exhibited less than 0.5% changes in mean echogenicity. We found that changes in mean echogenicity measured with ultrasound increased proportionally with increased tendon damage. The magnitude of these changes was relatively small (<1.5% change in mean echogenicity) but may be an effective predictor of tendon failure. Mean echogenicity is a promising marker for quantifying fatigue damage in cadaveric Achilles tendons during a stress test. Although these changes cannot be detected with the naked eye, computer-based predictive models may effectively assess risk of tendon damage in physically active adults.


Assuntos
Tendão do Calcâneo , Tendão do Calcâneo/diagnóstico por imagem , Adulto , Cadáver , Humanos , Fadiga Muscular , Ultrassonografia
14.
Biol Open ; 8(12)2019 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-31784422

RESUMO

Despite the robust findings linking plantar flexor muscle structure to gross function within athletes, the elderly and patients following Achilles tendon ruptures, the link between natural variation in plantar flexor structure and function in healthy adults is unclear. In this study, we determined the relationship between medial gastrocnemius structure and peak torque and total work about the ankle during maximal effort contractions. We measured resting fascicle length and pennation angle using ultrasound in healthy adults (N=12). Subjects performed maximal effort isometric and isokinetic contractions on a dynamometer. We found that longer fascicles were positively correlated with higher peak torque and total work (R2>0.41, P<0.013) across all isokinetic velocities, ranging from slow (30°/s) to fast (210°/s) contractions. Higher pennation angles were negatively correlated with peak torque and total work (R2>0.296, P<0.067). These correlations were not significant in isometric conditions. We further explored this relationship using a simple computational model to simulate isokinetic contractions. These simulations confirmed that longer fascicle lengths generate more joint torque and work throughout a greater range of motion. This study provides evidence that ankle function is strongly influenced by muscle structure in healthy adults.

15.
J Appl Physiol (1985) ; 127(4): 1005-1011, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31589091

RESUMO

Deficits in plantarflexor kinetics are associated with poor outcomes in patients following Achilles tendon rupture. In this longitudinal study, we analyzed the fascicle length and pennation angle of the medial gastrocnemius muscle and the length of the Achilles tendon using ultrasound imaging. To determine the relationship between muscle remodeling and deficits in plantarflexor kinetics measured at 14 wk after injury, we correlated the reduction in fascicle length and increase in pennation angle with peak torque measured during isometric and isokinetic plantarflexor contractions. We found that the medial gastrocnemius underwent an immediate change in structure, characterized by decreased length and increased pennation of the muscle fascicles. This decrease in fascicle length was coupled with an increase in tendon length. These changes in muscle-tendon structure persisted throughout the first 14 wk following rupture. Deficits in peak plantarflexor torque were moderately correlated with decreased fascicle length at 120 degrees per second (R2 = 0.424, P = 0.057) and strongly correlated with decreased fascicle length at 210 degrees per second (R2 = 0.737, P = 0.003). However, increases in pennation angle did not explain functional deficits. These findings suggest that muscle-tendon structure is detrimentally affected following Achilles tendon rupture. Plantarflexor power deficits are positively correlated with the magnitude of reductions in fascicle length. Preserving muscle structure following Achilles tendon rupture should be a clinical priority to maintain plantarflexor kinetics.NEW & NOTEWORTHY In our study, we found that when the Achilles tendon ruptures due to excessive biomechanical loading, the neighboring skeletal muscle undergoes rapid changes in its configuration. The magnitude of this muscle remodeling explains the amount of ankle power loss demonstrated by these patients once their Achilles tendons are fully healed. These findings highlight the interconnected relationship between muscle and tendon. Isolated injuries to the tendon stimulate detrimental changes to the muscle, thereby limiting joint-level function.


Assuntos
Tendão do Calcâneo/fisiopatologia , Músculo Esquelético/fisiopatologia , Traumatismos dos Tendões/fisiopatologia , Adulto , Tornozelo/fisiopatologia , Articulação do Tornozelo/fisiopatologia , Contratura/fisiopatologia , Humanos , Cinética , Estudos Longitudinais , Masculino , Movimento/fisiologia , Torque , Ultrassonografia/métodos
16.
PeerJ ; 7: e7120, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31304054

RESUMO

BACKGROUND: Ultrasound has become a commonly used imaging modality for making dynamic measurements of muscle structure during functional movements in biomechanical studies. Manual measurements of fascicle length and pennation angle are time intensive which limits the clinical utility of this approach while also limiting sample sizes in research. The purpose of this study was to develop an automatic fascicle tracking program to quantify the length and pennation angle of a muscle fascicle during maximal effort voluntary contractions and to evaluate its repeatability between days and reproducibility between different examiners. METHODS: Five healthy adults performed maximal effort isometric and isokinetic contractions at 30, 120, 210, and 500 degrees per second about their ankle on an isokinetic dynamometer while their medial gastrocnemius muscle was observed using ultrasound. Individual muscle fascicles and the two aponeuroses were identified by the user in the first frame and automatically tracked by the algorithm by three observers on three separate days. Users also made manual measurements of the candidate fascicle for validation. Repeatability within examiners across days and reproducibility across examiners and days were evaluated using intra-class correlation coefficients (ICC). Agreement between manual and automatic tracking was evaluated using the coefficient of multiple correlations (CMC) and root-mean-square error. Supervised automatic tracking, where the program could be reinitialized if poor tracking was observed, was performed on all videos by one examiner to evaluate the performance of automatic tracking in a typical use case. We also compared the performance our program to a preexisting automatic tracking program. RESULTS: We found both manual and automatic measurements of fascicle length and pennation angle to be strongly repeatable within examiners and strongly reproducible across examiners and days (ICCs > 0.74). There was greater agreement between manual and automatic measurements of fascicle length than pennation angle, however the mean CMC value was found to be strong in both cases (CMC > 0.8). Supervision of automatic tracking showed very strong agreement between manual and automatic measurements of fascicle length and pennation angle (CMC > 0.94). It also had considerably less error relative to the preexisting automatic tracking program. CONCLUSIONS: We have developed a novel automatic fascicle tracking algorithm that quantifies fascicle length and pennation angle of individual muscle fascicles during dynamic contractions during isometric and across a range of isokinetic velocities. We demonstrated that this fascicle tracking algorithm is strongly repeatable and reproducible across different examiners and different days and showed strong agreement with manual measurements, especially when tracking is supervised by the user so that tracking can be reinitialized if poor tracking quality is observed.

17.
PeerJ ; 7: e6788, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31065459

RESUMO

The purpose of this study was to characterize the short-term effects of Achilles tendon ruptures on medial gastrocnemius. We hypothesized that the fascicles of the medial gastrocnemius muscle of the injured Achilles tendon would be shorter and more pennate immediately following the injury and would persist throughout 4 weeks post-injury. B-mode longitudinal ultrasound images of the medial gastrocnemius were acquired in 10 adults who suffered acute Achilles tendon ruptures and were treated non-operatively. Ultrasound images were acquired during the initial clinical visit following injury as well as 2 and 4 weeks following this initial clinical visit. Resting muscle structure was characterized by measuring fascicle length, pennation angle, muscle thickness, and muscle echo intensity in both the injured and contralateral (control) limbs. Fascicle length was 15% shorter (P < 0.001) and pennation angle was 21% greater (P < 0.001) in the injured muscle compared to the uninjured (control) muscle at the presentation of injury (week 0). These differences in fascicle length persisted through 4 weeks after injury (P < 0.002) and pennation angle returned to pre-injury levels. Muscle thickness changes were not detected at any of the post-injury visits (difference < 4%, P > 0.026). Echo intensity of the injured limb was 8% lower at the presentation of the injury but was not different compared to the contralateral muscle at 2 and 4 weeks post-injury. Our results suggest that Achilles tendon ruptures elicit rapid changes in the configuration of the medial gastrocnemius, which may explain long-term functional deficits.

18.
J Biomech ; 89: 105-109, 2019 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-30981425

RESUMO

Low-cost sensors provide a unique opportunity to continuously monitor patient progress during rehabilitation; however, these sensors have yet to demonstrate the fidelity and lack the calibration paradigms necessary to be viable tools for clinical research. The purpose of this study was to validate a low-cost wearable sensor that accurately measured peak knee extension during clinical exercises and needed no additional equipment for calibration. Sagittal plane knee motion was quantified using a 9-axis motion sensor and directly compared to motion capture data. The motion sensor measured the field strength of a strong earth magnet secured to the distal femur, which was correlated with knee angle during a simple calibration process. Peak knee motions and kinematic patterns were compared with motion capture data using paired t-tests and cross correlation, respectively. Peak extension values during seated knee extensions were accurate within 5 degrees across all subjects (root mean square error: 2.6 degrees, P = 0.29). Knee flexion during gait strongly correlated (0.84 ≤ rxy ≤ 0.99) with motion capture measurements but demonstrated peak flexion errors of 10 degrees. In this study, we present a low-cost sensor (≈$ 35 US) that accurately determines knee extension angle following a calibration procedure that did not require any other equipment. Our findings demonstrate that this sensor paradigm is a feasible tool to monitor patient progress throughout physical therapy. However, dynamic motions that are associated with soft-tissue artifact may limit the accuracy of this type of wearable sensor.


Assuntos
Joelho/fisiologia , Monitorização Fisiológica/instrumentação , Movimento , Dispositivos Eletrônicos Vestíveis , Adulto , Fenômenos Biomecânicos , Calibragem , Fêmur/fisiologia , Marcha , Humanos , Masculino
19.
BMC Musculoskelet Disord ; 19(1): 399, 2018 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-30424811

RESUMO

BACKGROUND: Musculoskeletal models are commonly used to quantify joint motions and loads during human motion. Constraining joint kinematics simplifies these models but the implications of the placement and quantity of markers used during data acquisition remains unclear. The purpose of this study was to establish the effects of marker placement and quantity on lower extremity kinematics calculated using a constrained-kinematic model. We hypothesized that a constrained-kinematic model would produce lower-extremity kinematics errors that correlated with the number of tracking markers removed from the thigh and shank. METHODS: Healthy-young adults (N = 10) walked on a treadmill at slow, moderate, and fast speeds while skin-mounted markers were tracked using motion capture. Lower extremity kinematics were calculated for 256 combinations of leg and shank markers to establish the implications of marker placement and quantity on joint kinematics. Marker combinations that yielded differences greater than 5 degrees were tested with paired t-tests and the relationship between number of markers and kinematic errors were modeled with polynomials to determine goodness of fit (R2). RESULTS: Sagittal joint and hip coronal kinematics errors were smaller than documented errors caused by soft-tissue artifact, which tends to be approximately 5 degrees, when excluding thigh and shank markers. Joint angle and center kinematic errors negatively correlated with the number of markers included in the analyses (R2 > 0.97) and typically showed the greatest error reductions when two markers were included on the thigh or shank segments. Further, we demonstrated that a simplified marker set that included markers on the pelvis, lateral knee condyle, lateral malleolus, and shoes produced kinematics that strongly agreed with the traditional marker set that included 3 tracking markers for each segment. CONCLUSION: Constrained-kinematic models are resilient to marker placement and quantity, which has implications on study design and post-processing workflows.


Assuntos
Teste de Esforço/métodos , Extremidade Inferior/fisiologia , Modelos Biológicos , Adulto , Fenômenos Biomecânicos/fisiologia , Feminino , Humanos , Extremidade Inferior/anatomia & histologia , Masculino , Pelve/anatomia & histologia , Pelve/fisiologia , Coxa da Perna/anatomia & histologia , Coxa da Perna/fisiologia , Adulto Jovem
20.
J Biomech ; 79: 238-242, 2018 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-30166224

RESUMO

Achilles tendon ruptures are common injuries that often lead to long-term functional deficits. Despite the prevalence of these injuries, the mechanism responsible for limited function has not yet been established. Therefore, the purpose of this study was to present preliminary findings that support a hypothesis that skeletal muscle remodeling is the driving factor of poor outcomes in some patients. Biomechanical and ultrasonography assessments were performed on a patient that presented with poor functional outcomes 2.5 years after a surgically-repaired acute Achilles tendon rupture. Single-leg heel raise height was decreased by 75% in the affected limb (3.0 cm compared to 11.9 cm) while walking mechanics showed no deficits. Ultrasonography revealed that the affected medial gastrocnemius muscle was less thick and had shorter, more pennate fascicles compared to the unaffected limb. A simple computational model of a maximal-effort plantarflexion contraction was employed to test the implications of changes in muscle architecture on single-leg heel raise function. Subject-specific measurements of fascicle length and pennation were input into the model, which supported these architectural parameters as being drivers of heel raise function. These preliminary findings support the hypothesis that an Achilles tendon rupture elicits changes in skeletal muscle architecture, which reduces the amount of work and power the joint can generate. This multidisciplinary framework of biomechanical, imaging, and computational modeling provides a unique platform for studying the complex interactions between structure and function in patients recovering from Achilles tendon injuries.


Assuntos
Tendão do Calcâneo/lesões , Tendão do Calcâneo/fisiopatologia , Pé/cirurgia , Ruptura/fisiopatologia , Traumatismos dos Tendões/fisiopatologia , Tendão do Calcâneo/diagnóstico por imagem , Tendão do Calcâneo/cirurgia , Adulto , Pé/fisiopatologia , Humanos , Masculino , Músculo Esquelético/fisiopatologia , Procedimentos de Cirurgia Plástica , Ruptura/diagnóstico por imagem , Ruptura/cirurgia , Traumatismos dos Tendões/diagnóstico por imagem , Traumatismos dos Tendões/cirurgia , Ultrassonografia , Caminhada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA