Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
Acta Paediatr ; 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38808465

RESUMO

AIM: Sudden unexpected postnatal collapse is a life-threatening event and may occur in any newborn infant. Safe skin-to-skin contact, and awareness of sudden unexpected postnatal collapse are key to its prevention. The aim of this study was to survey the presence of skin-to-skin contact and/or sudden unexpected postnatal collapse protocols in the 70 perinatal centres in the Netherlands. METHODS: We performed a survey among Dutch paediatricians to examine the safe skin-to-skin contact and sudden unexpected postnatal collapse protocols. RESULTS: We received data from 59/70 (85%) perinatal centres. At least one case of sudden unexpected postnatal collapse was reported in 35/59 (59%) of these centres. Nearly half the centres had safe skin-to-skin contact and/or sudden unexpected postnatal collapse protocols. Ultimately, 16 protocols were available for analysis. They showed considerable differences in the type of perinatal care provided. Most protocols lacked recently published insights on safe skin-to-skin contact. Besides, protocols failed to incorporate awareness of and knowledge on how to prevent sudden unexpected postnatal collapse. CONCLUSION: This study underlines the importance of drawing up uniform, multidisciplinary guidelines containing recommendations for the prevention of sudden unexpected postnatal collapse in the Netherlands.

2.
J Infect Dis ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38781449

RESUMO

OBJECTIVE: The fecal microbiota and metabolome are hypothesized to be altered before late-onset neonatal meningitis (LOM), in analogy to late-onset sepsis (LOS). The present study aimed to identify fecal microbiota composition and volatile metabolomics preceding LOM. METHODS: Cases and gestational age-matched controls were selected from a prospective, longitudinal preterm cohort study (born <30 weeks' gestation) at nine neonatal intensive care units. The microbial composition (16S rRNA sequencing) and volatile metabolome (gas chromatography-ion mobility spectrometry (GC-IMS) and GC-time-of-flight-mass spectrometry (GC-TOF-MS)), were analyzed in fecal samples 1-10 days pre-LOM. RESULTS: Of 1397 included infants, 21 were diagnosed with LOM (1.5%), and 19 with concomitant LOS (90%). Random Forest classification and MaAsLin2 analysis found similar microbiota features contribute to the discrimination of fecal pre-LOM samples versus controls. A Random Forest model based on six microbiota features accurately predicts LOM 1-3 days before diagnosis with an area under the curve (AUC) of 0.88 (n=147). Pattern recognition analysis by GC-IMS revealed an AUC of 0.70-0.76 (P<0.05) in the three days pre-LOM (n=92). No single discriminative metabolites were identified by GC-TOF-MS (n=66). CONCLUSION: Infants with LOM could be accurately discriminated from controls based on preclinical microbiota composition, while alterations in the volatile metabolome were moderately associated with preclinical LOM.

4.
Trials ; 25(1): 164, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38439024

RESUMO

BACKGROUND: Mortality, cerebral injury, and necrotizing enterocolitis (NEC) are common complications of very preterm birth. An important risk factor for these complications is hemodynamic instability. Pre-clinical studies suggest that the timing of umbilical cord clamping affects hemodynamic stability during transition. Standard care is time-based cord clamping (TBCC), with clamping irrespective of lung aeration. It is unknown whether delaying cord clamping until lung aeration and ventilation have been established (physiological-based cord clamping, PBCC) is more beneficial. This document describes the statistical analyses for the ABC3 trial, which aims to assess the efficacy and safety of PBCC, compared to TBCC. METHODS: The ABC3 trial is a multicenter, randomized trial investigating PBCC (intervention) versus TBCC (control) in very preterm infants. The trial is ethically approved. Preterm infants born before 30 weeks of gestation are randomized after parental informed consent. The primary outcome is intact survival, defined as the composite of survival without major cerebral injury and/or NEC. Secondary short-term outcomes are co-morbidities and adverse events assessed during NICU admission, parental reported outcomes, and long-term neurodevelopmental outcomes assessed at a corrected age of 2 years. To test the hypothesis that PBCC increases intact survival, a logistic regression model will be estimated using generalized estimating equations (accounting for correlation between siblings and observations in the same center) with treatment and gestational age as predictors. This plan is written and submitted without knowledge of the data. DISCUSSION: The findings of this trial will provide evidence for future clinical guidelines on optimal cord clamping management at birth. TRIAL REGISTRATION: ClinicalTrials.gov NCT03808051. Registered on 17 January 2019.


Assuntos
Recém-Nascido Prematuro , Nascimento Prematuro , Lactente , Feminino , Recém-Nascido , Humanos , Pré-Escolar , Constrição , Recém-Nascido de muito Baixo Peso , Respiração
5.
Early Hum Dev ; 189: 105927, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38183863

RESUMO

BACKGROUND: Tissue hypoxia remains a leading cause of morbidity and mortality in preterm infants. Current biomarkers often detect irreversible hypoxic cellular injury (i.e. lactate) and are non-specific. A new biomarker is needed which detects tissue hypoxia before irreversible damage occurs. AIMS: To investigate the relation between serum ischemia modified albumin (IMA), a marker of hypoxia; and analytic variables, patient related variables and conditions associated with hypoxia, in preterm infants. STUDY DESIGN: Retrospective cohort study. SUBJECTS: Infants with a gestational age < 30 weeks and/or birth weight < 1000 g. OUTCOME MEASURES: We collected two remnant blood samples in the first week after birth and measured IMA. IMA/albumin ratio (IMAR) was used to adjust for albumin. We assessed correlations between IMA(R) and analytic variables (albumin, lipemia- and haemolysis index); mean-2 h SpO2; mean-2 h variability of regional splanchnic oxygen saturation (rsSO2), measured using near-infrared spectroscopy; and patent ductus arteriosus (PDA). RESULTS: Sixty-five infants were included. Albumin, the lipemia- and haemolysis index correlated negatively with IMA (r:-0.620, P<0.001; r:-0.458, P<0.001; and r:-0.337, P=0.002). IMAR correlated negatively with SpO2 (rho:-0.614, P<0.001). Lower rsSO2 variability correlated with higher IMAR values (rho:-0.785, n=14, P=0.001 and rho:-0.773, n=11, P=0.005). Infants with a hemodynamic significant PDA (hsPDA) had higher IMAR values than infants without PDA (0.13 [0.11-0.28], n=16 vs. 0.11 [0.08-0.20], n=29, P=0.005 and 0.11 [0.09-0.18], n=13 vs. 0.09 [0.06-0.17], n=37, P=0.026). CONCLUSIONS: When adjusted for albumin, the lipemia- and haemolysis index, IMAR has potential value as a marker for systemic hypoxia in preterm infants, considering the associations with SpO2, variability of rsSO2, and hsPDA.


Assuntos
Permeabilidade do Canal Arterial , Hiperlipidemias , Humanos , Recém-Nascido , Lactente , Recém-Nascido Prematuro , Biomarcadores , Estudos Retrospectivos , Hemólise , Albumina Sérica , Hipóxia , Isquemia
6.
JAMA ; 330(11): 1054-1063, 2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37695601

RESUMO

Importance: The long-term effects of surfactant administration via a thin catheter (minimally invasive surfactant therapy [MIST]) in preterm infants with respiratory distress syndrome remain to be definitively clarified. Objective: To examine the effect of MIST on death or neurodevelopmental disability (NDD) at 2 years' corrected age. Design, Setting, and Participants: Follow-up study of a randomized clinical trial with blinding of clinicians and outcome assessors conducted in 33 tertiary-level neonatal intensive care units in 11 countries. The trial included 486 infants with a gestational age of 25 to 28 weeks supported with continuous positive airway pressure (CPAP). Collection of follow-up data at 2 years' corrected age was completed on December 9, 2022. Interventions: Infants assigned to MIST (n = 242) received exogenous surfactant (200 mg/kg poractant alfa) via a thin catheter; those assigned to the control group (n = 244) received sham treatment. Main Outcomes and Measures: The key secondary outcome of death or moderate to severe NDD was assessed at 2 years' corrected age. Other secondary outcomes included components of this composite outcome, as well as hospitalizations for respiratory illness and parent-reported wheezing or breathing difficulty in the first 2 years. Results: Among the 486 infants randomized, 453 had follow-up data available (median gestation, 27.3 weeks; 228 females [50.3%]); data on the key secondary outcome were available in 434 infants. Death or NDD occurred in 78 infants (36.3%) in the MIST group and 79 (36.1%) in the control group (risk difference, 0% [95% CI, -7.6% to 7.7%]; relative risk [RR], 1.0 [95% CI, 0.81-1.24]); components of this outcome did not differ significantly between groups. Secondary respiratory outcomes favored the MIST group. Hospitalization with respiratory illness occurred in 49 infants (25.1%) in the MIST group vs 78 (38.2%) in the control group (RR, 0.66 [95% CI, 0.54-0.81]) and parent-reported wheezing or breathing difficulty in 73 (40.6%) vs 104 (53.6%), respectively (RR, 0.76 [95% CI, 0.63-0.90]). Conclusions and Relevance: In this follow-up study of a randomized clinical trial of preterm infants with respiratory distress syndrome supported with CPAP, MIST compared with sham treatment did not reduce the incidence of death or NDD by 2 years of age. However, infants who received MIST had lower rates of adverse respiratory outcomes during their first 2 years of life. Trial Registration: anzctr.org.au Identifier: ACTRN12611000916943.


Assuntos
Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Feminino , Humanos , Lactente , Recém-Nascido , Dispneia , Seguimentos , Recém-Nascido Prematuro , Lipoproteínas , Surfactantes Pulmonares/administração & dosagem , Surfactantes Pulmonares/uso terapêutico , Síndrome do Desconforto Respiratório/complicações , Síndrome do Desconforto Respiratório/tratamento farmacológico , Síndrome do Desconforto Respiratório/terapia , Síndrome do Desconforto Respiratório do Recém-Nascido/complicações , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Sons Respiratórios , Tensoativos/administração & dosagem , Tensoativos/uso terapêutico , Cateterismo , Procedimentos Cirúrgicos Minimamente Invasivos , Pressão Positiva Contínua nas Vias Aéreas , Masculino , Pré-Escolar
7.
Microorganisms ; 11(3)2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-36985146

RESUMO

Early detection of late-onset sepsis (LOS) in preterm infants is crucial since timely treatment initiation is a key prognostic factor. We hypothesized that fecal volatile organic compounds (VOCs), reflecting microbiota composition and function, could serve as a non-invasive biomarker for preclinical pathogen-specific LOS detection. Fecal samples and clinical data of all preterm infants (≤30 weeks' gestation) admitted at nine neonatal intensive care units in the Netherlands and Belgium were collected daily. Samples from one to three days before LOS onset were analyzed by gas chromatography-ion mobility spectrometry (GC-IMS), a technique based on pattern recognition, and gas chromatography-time of flight-mass spectrometry (GC-TOF-MS), to identify unique metabolites. Fecal VOC profiles and metabolites from infants with LOS were compared with matched controls. Samples from 121 LOS infants and 121 matched controls were analyzed using GC-IMS, and from 34 LOS infants and 34 matched controls using GC-TOF-MS. Differences in fecal VOCs were most profound one and two days preceding Escherichia coli LOS (Area Under Curve; p-value: 0.73; p = 0.02, 0.83; p < 0.002, respectively) and two and three days before gram-negative LOS (0.81; p < 0.001, 0.85; p < 0.001, respectively). GC-TOF-MS identified pathogen-specific discriminative metabolites for LOS. This study underlines the potential for VOCs as a non-invasive preclinical diagnostic LOS biomarker.

8.
JAMA Pediatr ; 177(5): 479-488, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36912856

RESUMO

Importance: Quantification of bilirubin in blood is essential for early diagnosis and timely treatment of neonatal hyperbilirubinemia. Handheld point-of-care (POC) devices may overcome the current issues with conventional laboratory-based bilirubin (LBB) quantification. Objective: To systematically evaluate the reported diagnostic accuracy of POC devices compared with LBB quantification. Data Sources: A systematic literature search was conducted in 6 electronic databases (Ovid MEDLINE, Embase, Web of Science Core Collection, Cochrane Central Register of Controlled Trials, CINAHL, and Google Scholar) up to December 5, 2022. Study Selection: Studies were included in this systematic review and meta-analysis if they had a prospective cohort, retrospective cohort, or cross-sectional design and reported on the comparison between POC device(s) and LBB quantification in neonates aged 0 to 28 days. Point-of-care devices needed the following characteristics: portable, handheld, and able to provide a result within 30 minutes. This study was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-analyses reporting guideline. Data Extraction and Synthesis: Data extraction was performed by 2 independent reviewers into a prespecified, customized form. Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Meta-analysis was performed of multiple Bland-Altman studies using the Tipton and Shuster method for the main outcome. Main Outcomes and Measures: The main outcome was mean difference and limits of agreement in bilirubin levels between POC device and LBB quantification. Secondary outcomes were (1) turnaround time (TAT), (2) blood volumes, and (3) percentage of failed quantifications. Results: Ten studies met the inclusion criteria (9 cross-sectional studies and 1 prospective cohort study), representing 3122 neonates. Three studies were considered to have a high risk of bias. The Bilistick was evaluated as the index test in 8 studies and the BiliSpec in 2. A total of 3122 paired measurements showed a pooled mean difference in total bilirubin levels of -14 µmol/L, with pooled 95% CBs of -106 to 78 µmol/L. For the Bilistick, the pooled mean difference was -17 µmol/L (95% CBs, -114 to 80 µmol/L). Point-of-care devices were faster in returning results compared with LBB quantification, whereas blood volume needed was less. The Bilistick was more likely to have a failed quantification compared with LBB. Conclusions and Relevance: Despite the advantages that handheld POC devices offer, these findings suggest that the imprecision for measurement of neonatal bilirubin needs improvement to tailor neonatal jaundice management.


Assuntos
Bilirrubina , Testes Imediatos , Recém-Nascido , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Estudos Transversais
9.
J Thromb Haemost ; 21(4): 963-974, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36696213

RESUMO

BACKGROUND: In critically ill (preterm) neonates, catheter-related venous thromboembolism (CVTE) can be a life-threatening complication. Evidence on optimal management in the literature is lacking. In the Netherlands, a consensus-based national management guideline was developed to create uniform CVTE management. OBJECTIVES: To evaluate the efficacy and safety of the national guideline. METHODS: This prospective, multicenter, observational study included all infants aged ≤6 months with CVTE in the Netherlands between 2014 and 2019. CVTE was divided into thrombosis in veins and that in the right atrium, with their own treatment algorithms. The primary outcomes were recurrent venous thrombotic events (VTEs) and/or death due to CVTE as well as major bleeding. RESULTS: Overall, 115 neonates were included (62% male; 79% preterm). The estimated incidence of CVTE was 4.0 per 1000 neonatal intensive care unit admissions. Recurrent thrombosis occurred in 2 (1.7%) infants and death due to CVTE in 1 (0.9%) infant. Major bleeding developed in 9 (7.8%) infants: 2 of 7 (29%) on recombinant tissue plasminogen activator, which was given for high-risk right-atrium thrombosis, and 7 of 63 (11%) on low-molecular-weight heparin (LMWH). Five of the 7 bleedings because of LMWH were complications of subcutaneous catheter use for LMWH administration. CONCLUSION: The management of neonatal CVTE according to the Dutch CVTE management guideline led to a low incidence of recurrent VTEs and death due to VTEs. Major bleeding occurred in 7.8% of the infants. Specific guideline adjustments may improve efficacy and, especially, safety of CVTE management in neonates.


Assuntos
Trombose Venosa Profunda de Membros Superiores , Trombose Venosa , Lactente , Recém-Nascido , Masculino , Humanos , Feminino , Heparina de Baixo Peso Molecular/uso terapêutico , Anticoagulantes/efeitos adversos , Ativador de Plasminogênio Tecidual , Estudos Prospectivos , Trombose Venosa/diagnóstico , Trombose Venosa/tratamento farmacológico , Trombose Venosa/epidemiologia , Hemorragia/induzido quimicamente , Catéteres
10.
BMJ Open ; 12(11): e061897, 2022 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-36396315

RESUMO

INTRODUCTION: Severe neonatal hyperbilirubinaemia can place a neonate at risk for acute bilirubin encephalopathy and kernicterus spectrum disorder. Early diagnosis is essential to prevent these deleterious sequelae. Currently, screening by visual inspection followed by laboratory-based bilirubin (LBB) quantification is used to identify hyperbilirubinaemia in neonates cared for at home in the Netherlands. However, the reliability of visual inspection is limited. We aim to evaluate the effectiveness of universal transcutaneous bilirubin (TcB) screening as compared with visual inspection to: (1) increase the detection of hyperbilirubinaemia necessitating treatment, and (2) reduce the need for heel pricks to quantify bilirubin levels. In parallel, we will evaluate a smartphone app (Picterus), and a point-of-care device for quantifying total bilirubin (Bilistick) as compared with LBB. METHODS AND ANALYSIS: We will undertake a multicentre prospective cohort study in nine midwifery practices across the Netherlands. Neonates born at a gestational age of 35 weeks or more are eligible if they: (1) are at home at any time between days 2 and 8 of life; (2) have their first midwife visit prior to postnatal day 6 and (3) did not previously receive phototherapy. TcB and the Picterus app will be used after visual inspection. When LBB is deemed necessary based on visual inspection and/or TcB reading, Bilistick will be used in parallel. The coprimary endpoints of the study are: (1) hyperbilirubinaemia necessitating treatment; (2) the number of heel pricks performed to quantify LBB. We aim to include 2310 neonates in a 2-year period. Using a decision tree model, a cost-effectiveness analysis will be performed. ETHICS AND DISSEMINATION: This study has been approved by the Medical Research Ethical Committee of the Erasmus MC Rotterdam, Netherlands (MEC-2020-0618). Parents will provide written informed consent. The results of this study will be published in peer-reviewed journals. TRIAL REGISTRATION NUMBER: Dutch Trial Register (NL9545).


Assuntos
Icterícia Neonatal , Icterícia , Humanos , Recém-Nascido , Bilirrubina/análise , Icterícia Neonatal/diagnóstico , Estudos Multicêntricos como Assunto , Triagem Neonatal/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes
11.
Trials ; 23(1): 838, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36183143

RESUMO

BACKGROUND: International guidelines recommend delayed umbilical cord clamping (DCC) up to 1 min in preterm infants, unless the condition of the infant requires immediate resuscitation. However, clamping the cord prior to lung aeration may severely limit circulatory adaptation resulting in a reduction in cardiac output and hypoxia. Delaying cord clamping until lung aeration and ventilation have been established (physiological-based cord clamping, PBCC) allows for an adequately established pulmonary circulation and results in a more stable circulatory transition. The decline in cardiac output following time-based delayed cord clamping (TBCC) may thus be avoided. We hypothesise that PBCC, compared to TBCC, results in a more stable transition in very preterm infants, leading to improved clinical outcomes. The primary objective is to compare the effect of PBCC on intact survival with TBCC. METHODS: The Aeriation, Breathing, Clamping 3 (ABC3) trial is a multicentre randomised controlled clinical trial. In the interventional PBCC group, the umbilical cord is clamped after the infant is stabilised, defined as reaching heart rate > 100 bpm and SpO2 > 85% while using supplemental oxygen < 40%. In the control TBCC group, cord clamping is time based at 30-60 s. The primary outcome is survival without major cerebral and/or intestinal injury. Preterm infants born before 30 weeks of gestation are included after prenatal parental informed consent. The required sample size is 660 infants. DISCUSSION: The findings of this trial will provide evidence for future clinical guidelines on optimal cord clamping management in very preterm infants at birth. TRIAL REGISTRATION: ClinicalTrials.gov NCT03808051. First registered on January 17, 2019.


Assuntos
Recém-Nascido Prematuro , Recém-Nascido de muito Baixo Peso , Constrição , Feminino , Retardo do Crescimento Fetal , Humanos , Lactente , Recém-Nascido , Estudos Multicêntricos como Assunto , Oxigênio , Gravidez , Ensaios Clínicos Controlados Aleatórios como Assunto , Cordão Umbilical/cirurgia
12.
PLoS One ; 17(6): e0269286, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35709090

RESUMO

BACKGROUND: Severe hyperbilirubinemia is more frequent in low- and middle-income countries such as Indonesia than in high-income countries. One of the contributing factors might be the lack of adherence to existing guidelines on the diagnosis and treatment of hyperbilirubinemia. We developed a new national guideline for hyperbilirubinemia management in Indonesia. To help healthcare workers use this guideline, a web-based decision support tool application may improve both the adherence to the guideline and the care for infants with hyperbilirubinemia. METHODS: We developed a web-based application (BiliNorm) to be used on a smartphone that displays the bilirubin level of the patient on the nomogram and advises about the treatment that should be started. Healthcare workers of two teaching hospitals in East Java, Indonesia, were trained on the use of BiliNorm. At 6 months after the introduction, a questionnaire was sent to those who worked with the application enquiring about their experiences. An observational study was conducted in two time epochs. A chart review of infants with hyperbilirubinemia in the two hospitals was sent. The appropriateness of hyperbilirubinemia management during a 6-month period before BiliNorm introduction was compared to that during a 7-month period after its introduction. RESULTS: A total of 43 participants filled in the questionnaire, the majority (72%) of them indicated that BiliNorm was well received and easy to use. Moreover, 84% indicated that BiliNorm was helpful for the decision to start phototherapy. Chart review of 255 infants before BiliNorm introduction and that of 181 infants after its introduction indicated that significantly more infants had received treatment according to the guideline (38% vs 51%, p = 0.006). Few infants received phototherapy, but bilirubin level was not measured (14% vs 7%, p = 0.024). There was no difference in the proportion of infants who were over- and under-treated (34% vs 32% and 14% vs 10%, respectively). CONCLUSIONS: The web-based decision tool BiliNorm appears to be a valuable application. It is easy to use for healthcare workers and helps them adhere to the guideline. It improves the care for infants with hyperbilirubinemia and may help reduce the incidence of severe hyperbilirubinemia in Indonesia.


Assuntos
Doenças Hematológicas , Hiperbilirrubinemia Neonatal , Aplicativos Móveis , Bilirrubina , Humanos , Hiperbilirrubinemia/epidemiologia , Hiperbilirrubinemia Neonatal/terapia , Indonésia/epidemiologia , Recém-Nascido , Fototerapia
13.
Arch Dis Child Fetal Neonatal Ed ; 107(5): 527-532, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35091450

RESUMO

OBJECTIVES: To describe characteristics of neonates with severe neonatal hyperbilirubinaemia (SNH) and to gain more insight in improvable factors that may have contributed to the development of SNH. DESIGN AND SETTING: Descriptive study, based on national Dutch perinatal audit data on SNH from 2017 to 2019. PATIENTS: Neonates, born ≥35 weeks of gestation and without antenatally known severe blood group incompatibility, who developed hyperbilirubinaemia above the exchange transfusion threshold. MAIN OUTCOME MEASURES: Characteristics of neonates having SNH and corresponding improvable factors. RESULTS: During the 3-year period, 109 neonates met the eligibility criteria. ABO antagonism was the most frequent cause (43%). All neonates received intensive phototherapy and 30 neonates (28%) received an exchange transfusion. Improvable factors were mainly related to lack of knowledge, poor adherence to the national hyperbilirubinaemia guideline, and to incomplete documentation and insufficient communication of the a priori hyperbilirubinaemia risk assessment among healthcare providers. A priori risk assessment, a key recommendation in the national hyperbilirubinaemia guideline, was documented in only six neonates (6%). CONCLUSIONS: SNH remains a serious threat to neonatal health in the Netherlands. ABO antagonism frequently underlies SNH. Lack of compliance to the national guideline including insufficient a priori hyperbilirubinaemia risk assessment, and communication among healthcare providers are important improvable factors. Implementation of universal bilirubin screening and better documentation of the risk of hyperbilirubinaemia may enhance early recognition of potentially dangerous neonatal jaundice.


Assuntos
Hiperbilirrubinemia Neonatal , Icterícia Neonatal , Bilirrubina , Etnicidade , Humanos , Hiperbilirrubinemia Neonatal/diagnóstico , Hiperbilirrubinemia Neonatal/epidemiologia , Hiperbilirrubinemia Neonatal/terapia , Recém-Nascido , Icterícia Neonatal/etiologia , Fototerapia/efeitos adversos
14.
Pediatr Res ; 92(2): 453-458, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34728809

RESUMO

BACKGROUND: Phototherapy (PT) is the standard treatment of neonatal unconjugated hyperbilirubinemia. The irradiance footprint, i.e., the illuminated area by the PT device with sufficient spectral irradiance, is essential for PT to be effective. Irradiance footprint measurements are not performed in current clinical practice. We describe a user-friendly method to systematically evaluate the high spectral irradiance (HSI) footprint (illuminated area with spectral irradiance of ≥30 µW cm-2 nm-1) of PT devices in clinical practice. MATERIALS AND METHODS: Six commercially available LED-based overhead PT devices were evaluated in overhead configuration with an incubator. Spectral irradiance (µW cm-2 nm-1) and HSI footprint were measured with a radiospectrometer (BiliBlanket Meter II). RESULTS: The average measured spectral irradiance ranged between 27 and 52 µW cm-2 nm-1 and HSI footprint ranged between 67 and 1465 cm2, respectively. Three, two, and one PT devices out of six covered the average BSA of an infant born at 22, 26-32, and 40 weeks of gestation, respectively. CONCLUSION: Spectral irradiance of LED-based overhead PT devices is often lower than manufacturer's specifications, and HSI footprints not always cover the average BSA of a newborn infant. The proposed measurement method will contribute to awareness of the importance of irradiance level as well as footprint measurements in the management of neonatal jaundice. IMPACT: While a sufficient spectral irradiance footprint is essential for PT to be effective, some PT devices have spectral irradiance footprints that are too small to cover the entire body surface area (BSA) of a newborn infant. This study introduces a user-friendly, accessible method to systematically evaluate the spectral irradiance level and footprint of PT devices. This study supports awareness on the role of the spectral irradiance footprint in the efficacy of PT devices. Irradiance footprint can be easily measured during phototherapy with the proposed method.


Assuntos
Hiperbilirrubinemia Neonatal , Icterícia Neonatal , Humanos , Hiperbilirrubinemia Neonatal/terapia , Recém-Nascido , Icterícia Neonatal/terapia , Fototerapia
15.
JAMA ; 326(24): 2478-2487, 2021 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-34902013

RESUMO

Importance: The benefits of surfactant administration via a thin catheter (minimally invasive surfactant therapy [MIST]) in preterm infants with respiratory distress syndrome are uncertain. Objective: To examine the effect of selective application of MIST at a low fraction of inspired oxygen threshold on survival without bronchopulmonary dysplasia (BPD). Design, Setting, and Participants: Randomized clinical trial including 485 preterm infants with a gestational age of 25 to 28 weeks who were supported with continuous positive airway pressure (CPAP) and required a fraction of inspired oxygen of 0.30 or greater within 6 hours of birth. The trial was conducted at 33 tertiary-level neonatal intensive care units around the world, with blinding of the clinicians and outcome assessors. Enrollment took place between December 16, 2011, and March 26, 2020; follow-up was completed on December 2, 2020. Interventions: Infants were randomized to the MIST group (n = 241) and received exogenous surfactant (200 mg/kg of poractant alfa) via a thin catheter or to the control group (n = 244) and received a sham (control) treatment; CPAP was continued thereafter in both groups unless specified intubation criteria were met. Main Outcomes and Measures: The primary outcome was the composite of death or physiological BPD assessed at 36 weeks' postmenstrual age. The components of the primary outcome (death prior to 36 weeks' postmenstrual age and BPD at 36 weeks' postmenstrual age) also were considered separately. Results: Among the 485 infants randomized (median gestational age, 27.3 weeks; 241 [49.7%] female), all completed follow-up. Death or BPD occurred in 105 infants (43.6%) in the MIST group and 121 (49.6%) in the control group (risk difference [RD], -6.3% [95% CI, -14.2% to 1.6%]; relative risk [RR], 0.87 [95% CI, 0.74 to 1.03]; P = .10). Incidence of death before 36 weeks' postmenstrual age did not differ significantly between groups (24 [10.0%] in MIST vs 19 [7.8%] in control; RD, 2.1% [95% CI, -3.6% to 7.8%]; RR, 1.27 [95% CI, 0.63 to 2.57]; P = .51), but incidence of BPD in survivors to 36 weeks' postmenstrual age was lower in the MIST group (81/217 [37.3%] vs 102/225 [45.3%] in the control group; RD, -7.8% [95% CI, -14.9% to -0.7%]; RR, 0.83 [95% CI, 0.70 to 0.98]; P = .03). Serious adverse events occurred in 10.3% of infants in the MIST group and 11.1% in the control group. Conclusions and Relevance: Among preterm infants with respiratory distress syndrome supported with CPAP, minimally invasive surfactant therapy compared with sham (control) treatment did not significantly reduce the incidence of the composite outcome of death or bronchopulmonary dysplasia at 36 weeks' postmenstrual age. However, given the statistical uncertainty reflected in the 95% CI, a clinically important effect cannot be excluded. Trial Registration: anzctr.org.au Identifier: ACTRN12611000916943.


Assuntos
Produtos Biológicos/administração & dosagem , Displasia Broncopulmonar/prevenção & controle , Pressão Positiva Contínua nas Vias Aéreas , Recém-Nascido Prematuro , Fosfolipídeos/administração & dosagem , Surfactantes Pulmonares/administração & dosagem , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Feminino , Humanos , Recém-Nascido , Doenças do Prematuro/mortalidade , Masculino , Síndrome do Desconforto Respiratório do Recém-Nascido/mortalidade , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Método Simples-Cego
16.
Neonatology ; 118(6): 678-684, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34818231

RESUMO

BACKGROUND: Recently, the Bilistick®, a point-of-care instrument to measure bilirubin levels, has been developed. It is fast and cheaper than transcutaneous bilirubin (TCB)-measuring devices, but data on diagnostic properties are scarce. OBJECTIVE: This study aimed to compare the performance of the Bilistick® (BM-BS 1.0 - FW version 2.0.1) and the JM-105 bilirubinometer for measuring bilirubin. METHOD: This is a prospective study in infants born after ≥32 weeks' gestation, and/or a birth weight of ≥1,500 g, and a postnatal age ≤14 days in Surabaya, Indonesia. Bilirubin was measured with the Bilistick® System (BM-BS 1.0 - FW version 2.0.1), transcutaneously (TCB) with the JM-105 bilirubinometer, and in serum (TSB) with a routine laboratory technique. Mean differences and 95% limits of agreement (LOA) and correlations were calculated. RESULT: We enrolled 149 neonates and 126 had paired measurements of Bilistick® bilirubin, TCB, and TSB. Bilistick® failed in 16 (10.7%) infants. Mean Bilistick® bilirubin-TSB difference was -11 µmol/L (95% LOA: -101 to 79 µmol/L) and r = 0.738 (p < 0.001). Mean TCB-TSB difference was 26 µmol/L (95% LOA: -33 to 88) and r = 0.785 (p < 0.001). The sensitivity, specificity, PPV, and NPV for Bilistick® bilirubin for a TSB above treatment thresholds were 0.74, 0.84, 0.67, and 0.88, respectively, and for TCB 0.92, 0.64, 0.54, and 0.95, respectively. CONCLUSION: The Bilistick® System (BM-BS 1.0 - FW version 2.0.1) underestimates TSB, whereas TCB overestimates TSB in jaundiced Indonesian infants. Further improvement of Bilistick®'s diagnostic accuracy with less false-negative readings is essential to increase its use.


Assuntos
Bilirrubina , Icterícia Neonatal , Humanos , Lactente , Recém-Nascido , Triagem Neonatal/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos
17.
Eur J Pediatr ; 180(12): 3491-3497, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34105002

RESUMO

Neonatal organ and tissue donation is not common practice in the Netherlands. At the same time, there is a transplant waiting list for small size-matched organs and tissues. Multiple factors may contribute to low neonatal donation rates, including a lack of awareness of this option. This study provides insight into potential neonatal organ and tissue donors and reports on how many donors were actually reported to the procurement organization. We performed a retrospective analysis of the mortality database and medical records of two largest neonatal intensive care units (NICUs) in the Netherlands. This study reviewed records of neonates with a gestational age >37 weeks and weight >3000g who died in the period from January 1, 2005 through December 31, 2016. During the study period, 259 term-born neonates died in the two NICUs. In total, 132 neonates with general contra-indications for donation were excluded. The medical records of 127 neonates were examined for donation suitability. We identified five neonates with documented brain death who were not recognized as potential organ and/or tissue donors. Of the remaining neonates, 27 were found suitable for tissue donation. One potential tissue donor had been reported to the procurement organization. In three cases, the possibility of donation was brought up by parents.Conclusion: A low proportion (2%) of neonates who died in the NICUs were found suitable for organ donation, and a higher proportion (12%) were found suitable for tissue donation. We suggest that increased awareness concerning the possibility of neonatal donation would likely increase the identification of potential neonatal donors. What is Known: • There is an urgent need for very small organs and tissues from neonatal donors What is New: • A number of neonates who died in the NICU were suitable organ or/and tissue donors but were not recognized as donors. • Knowledge on neonatal donation possibilities is also important for proper counseling of parents who sometimes inquire for the possibility of organ and tissue donation.


Assuntos
Obtenção de Tecidos e Órgãos , Morte Encefálica , Morte , Humanos , Lactente , Recém-Nascido , Estudos Retrospectivos , Doadores de Tecidos
19.
Pediatr Res ; 90(2): 277-283, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33948000

RESUMO

Invasive bilirubin measurements remain the gold standard for the diagnosis and treatment of infants with severe neonatal hyperbilirubinemia. The present paper describes different methods currently available to assess hyperbilirubinemia in newborn infants. Novel point-of-care bilirubin measurement methods, such as the BiliSpec and the Bilistick, would benefit many newborn infants, especially in low-income and middle-income countries where the access to costly multi-analyzer in vitro diagnostic instruments is limited. Total serum bilirubin test results should be accurate within permissible limits of measurement uncertainty to be fit for clinical purposes. This implies correct implementation of internationally endorsed reference measurement systems as well as participation in external quality assessment programs. Novel analytic methods may, apart from bilirubin, include the determination of bilirubin photoisomers and bilirubin oxidation products in blood and even in other biological matrices. IMPACT: Key message: Bilirubin measurements in blood remain the gold standard for diagnosis and treatment of severe neonatal hyperbilirubinemia (SNH). External quality assessment (EQA) plays an important role in revealing inaccuracies in diagnostic bilirubin measurements. What does this article add to the existing literature? We provide analytic performance data on total serum bilirubin (TSB) as measured during recent EQA surveys. We review novel diagnostic point-of-care (POC) bilirubin measurement methods and analytic methods for determining bilirubin levels in biological matrices other than blood. Impact: Manufacturers should make TSB test results traceable to the internationally endorsed total bilirubin reference measurement system and should ensure permissible limits of measurement uncertainty.


Assuntos
Bilirrubina/sangue , Hiperbilirrubinemia Neonatal/diagnóstico , Icterícia Neonatal/diagnóstico , Triagem Neonatal , Testes Imediatos , Biomarcadores/sangue , Humanos , Hiperbilirrubinemia Neonatal/sangue , Hiperbilirrubinemia Neonatal/terapia , Recém-Nascido , Icterícia Neonatal/sangue , Icterícia Neonatal/terapia , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Regulação para Cima
20.
Pediatr Res ; 90(2): 272-276, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33941863

RESUMO

Severe neonatal hyperbilirubinemia (SNH) is a serious condition that occurs worldwide. Timely recognition with bilirubin determination is key in the management of SNH. Visual assessment of jaundice is unreliable. Fortunately, transcutaneous bilirubin measurement for screening newborn infants is routinely available in many hospitals and outpatient settings. Despite a few limitations, the use of transcutaneous devices facilitates early recognition and appropriate management of neonatal jaundice. Unfortunately, however, advanced and often costly screening modalities are not accessible to everyone, while there is an urgent need for inexpensive yet accurate instruments to assess total serum bilirubin (TSB). In the near future, novel icterometers, and in particular optical bilirubin estimates obtained with a smartphone camera and processed with a smartphone application (app), seem promising methods for screening for SNH. If proven reliable, these methods may empower outpatient health workers as well as parents at home to detect jaundice using a simple portable device. Successful implementation of ubiquitous bilirubin screening may contribute substantially to the reduction of the worldwide burden of SNH. The benefits of non-invasive bilirubin screening notwithstanding, any bilirubin determination obtained through non-invasive screening must be confirmed by a diagnostic method before treatment. IMPACT: Key message: Screening methods for neonatal hyperbilirubinemia facilitate early recognition and timely treatment of severe neonatal hyperbilirubinemia (SNH). Any bilirubin screening result obtained must be confirmed by a diagnostic method. What does this article add to the existing literature? Data on optical bilirubin estimation are summarized. Niche research strategies for prevention of SNH are presented. Impact: Transcutaneous screening for neonatal hyperbilirubinemia contributes to the prevention of SNH. A smartphone application with optical bilirubin estimation seems a promising low-cost screening method, especially in low-resource settings or at home.


Assuntos
Bilirrubina/sangue , Hiperbilirrubinemia Neonatal/diagnóstico , Icterícia Neonatal/diagnóstico , Triagem Neonatal , Biomarcadores/sangue , Diagnóstico Precoce , Humanos , Hiperbilirrubinemia Neonatal/sangue , Hiperbilirrubinemia Neonatal/terapia , Recém-Nascido , Icterícia Neonatal/sangue , Icterícia Neonatal/terapia , Aplicativos Móveis , Triagem Neonatal/instrumentação , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Smartphone , Regulação para Cima
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA