Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
2.
Phys Rev A (Coll Park) ; 109(2)2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38617901

RESUMO

Ghost Imaging enables 2D reconstruction of an object even though particles transmitted or emitted by the object of interest are detected with a single pixel detector without spatial resolution. This is possible because for the particular implementation of ghost imaging presented here, the incident beam is spatially modulated with a non-configurable attenuating mask whose orientation is varied (e.g. via transverse displacement or rotation) in the course of the ghost imaging experiment. Each orientation yields a distinct spatial pattern in the attenuated beam. In many cases, ghost imaging reconstructions can be dramatically improved by factoring the measurement matrix which consists of measured attenuated incident radiation for each of many orientations of the mask at each pixel to be reconstructed as the product of an orthonormal matrix Qand an upper triangular matrix R provided that the number of orientations of the mask (N) is greater than or equal to the number of pixels (P) reconstructed. For the N

3.
Rev Sci Instrum ; 94(4)2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38081240

RESUMO

Neutron grating interferometry provides information on phase and small-angle scatter in addition to attenuation. Previously, phase grating moiré interferometers (PGMI) with two or three phase gratings have been developed. These phase-grating systems use the moiré far-field technique to avoid the need for high-aspect absorption gratings used in Talbot-Lau interferometers (TLI) that reduce the neutron flux reaching the detector. We first demonstrate, through theory and simulations, a novel phase grating interferometer system for cold neutrons that requires a single modulated phase grating (MPG) for phase-contrast imaging, as opposed to the two or three phase gratings in previously employed PGMI systems. The theory shows the dual modulation of MPG with a large period and a smaller carrier pitch P, resulting in large fringes at the detector. The theory was compared to the full Sommerfeld-Rayleigh diffraction integral simulator. Then, we proceeded to compare the MPG system to experiments in the literature that use a two-phase-grating-based PGMI with best-case visibility of around 39%. The simulations of the MPG system show improved visibility in comparison to that of the two-phase-grating-based PGMI. An MPG with a modulation period of 300 µm, the pitch of 2 µm, and grating heights with a phase modulation of (π,0, illuminated by a monochromatic beam produces visibility of 94.2% with a comparable source-to-detector distance (SDD) as the two-phase-grating-based PGMI. Phase sensitivity, another important performance metric of the grating interferometer, was compared to values available in the literature, viz. the conventional TLI with the phase sensitivity of 4.5 × 103 for an SDD of 3.5 m and a beam wavelength of 0.44 nm. For a range of modulation periods, the MPG system provides comparable or greater theoretical maximum phase sensitivity of 4.1 × 103 to 10.0 × 103 for SDDs of up to 3.5 m. This proposed MPG system appears capable of providing high-performance PGMI that obviates the need for the alignment of two phase gratings.

4.
Artigo em Inglês | MEDLINE | ID: mdl-34866719

RESUMO

The predominant geometry for a neutron imaging experiment is that of a pinhole camera. This is primarily due to the difficulty in focusing neutrons due to the weak refractive index, which is also strongly chromatic. Proof of concept experiments demonstrated that neutron image forming lenses based on reflective Wolter mirrors can produce quantitative, high spatial resolution neutron images while also increasing the time resolution compared to the conventional pinhole camera geometry. Motivated by these results, we report the design of a neutron microscope where two Wolter mirrors replace condensing and objective lenses, in direct analogy with typical visible light microscopes. Ray tracing results indicate that this system will yield 3 µm spatial resolution images with an acquisition time of order <1 s (104 faster than currently possible at this spatial resolution) with a field of view of about 5 mm in diameter.

5.
Rev Sci Instrum ; 91(7): 073303, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32752792

RESUMO

We report an experimental implementation for neutron transverse polarization analysis that is capable of detecting a small angular change (≪10-3 rad) in neutron spin orientation. This approach is demonstrated for monochromatic beams, and we show that it could be extended to polychromatic neutron beams. Our approach employs a 3He spin filter inside a solenoid with an analyzing direction perpendicular to the incident neutron polarization direction. The method was tested with polarized neutron beams and a spin rotator placed inside a µ-metal shield just upstream of the analyzer. No cryogenic superconducting shields or additional neutron spin manipulations are needed. With a counting detector, we experimentally show that the angular resolution δθ=1/(PnAN) rad is only determined by the counting statistics for the total counts N and the product of the neutron polarization Pn and the analyzing power A. With a high-flux neutron beam, 10-6 rad angular sensitivity is feasible within a day. This simple, classical-quantum-limited transverse polarization analysis scheme may reduce the overall complexity of experimental implementation for applications requiring sensitive neutron polarimetry and improve the precision in fundamental science studies and polarized neutron imaging.

6.
Phys Rev C ; 100(3)2019.
Artigo em Inglês | MEDLINE | ID: mdl-32128469

RESUMO

As a neutron scatters from a target nucleus, there is a small but measurable effect caused by the interaction of the neutron's magnetic dipole moment with that of the partially screened electric field of the nucleus. This spin-orbit interaction is typically referred to as Schwinger scattering and induces a small rotation of the neutron's spin on the order of 10-4 rad for Bragg diffraction from silicon. In our experiment, neutrons undergo greater than 100 successive Bragg reflections from the walls of a slotted, perfect-silicon crystal to amplify the total spin rotation. A magnetic field is employed to insure constructive addition as the neutron undergoes this series of reflections. The strength of the spin-orbit interaction, which is directly proportional to the electric field, was determined by measuring the rotation of the neutron's spin-polarization vector. Our measurements show good agreement with the expected variation of this rotation with the applied magnetic field, while the magnitude of the rotation is ≈40 % larger than expected.

7.
Phys Rev Lett ; 120(11): 113201, 2018 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-29601748

RESUMO

We demonstrate a three phase-grating moiré neutron interferometer in a highly intense neutron beam as a robust candidate for large area interferometry applications and for the characterization of materials. This novel far-field moiré technique allows for broad wavelength acceptance and relaxed requirements related to fabrication and alignment, thus circumventing the main obstacles associated with perfect crystal neutron interferometry. We observed interference fringes with an interferometer length of 4 m and examined the effects of an aluminum 6061 alloy sample on the coherence of the system. Experiments to measure the autocorrelation length of samples and the universal gravitational constant are proposed and discussed.

8.
Rev Sci Instrum ; 88(11): 113702, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29195378

RESUMO

Dual mode tomography using neutrons and X-rays offers the potential of improved estimation of the composition of a sample from the complementary interaction of the two probes with the sample. We have developed a simultaneous neutron and 90 keV X-ray tomography system that is well suited to the study of porous media systems such as fuel cells, concrete, unconventional reservoir geologies, limestones, and other geological media. We present the characteristic performance of both the neutron and X-ray modalities. We illustrate the use of the simultaneous acquisition through improved phase identification in a concrete core.

9.
Cryogenics (Guildf) ; 74: 131-137, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28154426

RESUMO

Passive and active technologies have been used to control propellant boil-off, but the current state of understanding of cryogenic evaporation and condensation in microgravity is insufficient for designing large cryogenic depots critical to the long-term space exploration missions. One of the key factors limiting the ability to design such systems is the uncertainty in the accommodation coefficients (evaporation and condensation), which are inputs for kinetic modeling of phase change. A novel, combined experimental and computational approach is being used to determine the accommodation coefficients for liquid hydrogen and liquid methane. The experimental effort utilizes the Neutron Imaging Facility located at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland to image evaporation and condensation of hydrogenated propellants inside of metallic containers. The computational effort includes numerical solution of a model for phase change in the contact line and thin film regions as well as an CFD effort for determining the appropriate thermal boundary conditions for the numerical solution of the evaporating and condensing liquid. Using all three methods, there is the possibility of extracting the accommodation coefficients from the experimental observations. The experiments are the first known observation of a liquid hydrogen menisci condensing and evaporating inside aluminum and stainless steel cylinders. The experimental technique, complimentary computational thermal model and meniscus shape determination are reported. The computational thermal model has been shown to accurately track the transient thermal response of the test cells. The meniscus shape determination suggests the presence of a finite contact angle, albeit very small, between liquid hydrogen and aluminum oxide.

10.
Soil Sci Soc Am J ; 76(4)2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34857982

RESUMO

Water retention curves are essential for understanding the hydrologic behavior of partially saturated porous media and modeling flow and transport processes within the vadose zone. We directly measured the main drying and wetting branches of the average water retention function obtained using two-dimensional neutron radiography. Flint sand columns were saturated with water and then drained and rewetted under quasi-equilibrium conditions using a hanging water column setup. Digital images (2048 by 2048 pixels) of the transmitted flux of neutrons were acquired at each imposed matric potential (∼10-15 matric potential values per experiment) at the National Institute of Standards and Technology Center for Neutron Research BT-2 neutron imaging beam line. Volumetric water contents were calculated on a pixel-by-pixel basis using Beer-Lambert's law after taking into account beam hardening and geometric corrections. To account for silica attenuation and remove scattering effects at high water contents, the volumetric water contents were normalized (to give relative saturations) by dividing the drying and wetting sequences of images by the images obtained at saturation and satiation, respectively. The resulting pixel values were then averaged and combined with information on the imposed basal matric potentials to give average water retention curves. The average relative saturations obtained by neutron radiography showed an approximate one-to-one relationship with the average values measured volumetrically using the hanging water column setup. There were no significant differences (P < 0.05) between the parameters of the van Genuchten equation fitted to the average neutron radiography data and those estimated from replicated hanging water column data. Our results indicate that neutron imaging is a very effective tool for quantifying the average water retention curve.

11.
J Appl Phys ; 112(10)2012.
Artigo em Inglês | MEDLINE | ID: mdl-35528323

RESUMO

The water sorption of proton-exchange membranes (PEMs) was measured in situ using high-resolution neutron imaging in small-scale fuel cell test sections. A detailed characterization of the measurement uncertainties and corrections associated with the technique is presented. An image-processing procedure resolved a previously reported discrepancy between the measured and predicted membrane water content. With high-resolution neutron-imaging detectors, the water distributions across N1140 and N117 Nafion membranes are resolved in vapor-sorption experiments and during fuel cell and hydrogen-pump operation. The measured in situ water content of a restricted membrane at 80 °C is shown to agree with ex situ gravimetric measurements of free-swelling membranes over a water activity range of 0.5 to 1.0 including at liquid equilibration. Schroeder's paradox was verified by in situ water-content measurements which go from a high value at supersaturated or liquid conditions to a lower one with fully saturated vapor. At open circuit and during fuel cell operation, the measured water content indicates that the membrane is operating between the vapor- and liquid-equilibrated states.

12.
Phys Rev Lett ; 102(20): 200401, 2009 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-19519009

RESUMO

We report the first measurement of the low-energy neutron-(3)He incoherent scattering length using neutron interferometry: b_{i};{'} = (-2.512 +/- 0.012 stat +/- 0.014 syst) fm. This is in good agreement with a recent calculation using the AV18 + 3N potential. The neutron-(3)He scattering lengths are important for testing and developing nuclear potential models that include three-nucleon forces, effective field theories for few-body nuclear systems, and neutron scattering measurements of quantum excitations in liquid helium. This work demonstrates the first use of a polarized nuclear target in a neutron interferometer.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA