Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Clin Chem ; 62(8): 1129-39, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27251038

RESUMO

BACKGROUND: Circulating tumor DNA (ctDNA) has emerged as a good candidate for tracking tumor dynamics in different cancer types, potentially avoiding repeated tumor biopsies. Many different genes can be mutated within a tumor, complicating procedures for tumor monitoring, even with highly sensitive next-generation sequencing (NGS) strategies. Droplet-based digital PCR (dPCR) is a highly sensitive and quantitative procedure, allowing detection of very low amounts of circulating tumor genetic material, but can be limited in the total number of target loci monitored. METHODS: We analyzed hypermethylation of 3 genes, by use of droplet-based dPCR in different stages of colorectal cancer (CRC), to identify universal markers for tumor follow-up. RESULTS: Hypermethylation of WIF1 (WNT inhibitory factor 1) and NPY (neuropeptide Y) genes was significantly higher in tumor tissue compared to normal tissue, independently of tumor stage. All tumor tissues appeared positive for one of the 2 markers. Methylated ctDNA (MetctDNA) was detected in 80% of metastatic CRC and 45% of localized CRC. For samples with detectable mutations in ctDNA, MetctDNA and mutant ctDNA (MutctDNA) fractions were correlated. During follow-up of different stage CRC patients, MetctDNA changes allowed monitoring of tumor evolution. CONCLUSIONS: These results indicate that MetctDNA could be used as a universal surrogate marker for tumor follow-up in CRC patients, and monitoring MetctDNA by droplet-based dPCR could avoid the need for monitoring mutations.


Assuntos
Proteínas Adaptadoras de Transdução de Sinal/genética , Biomarcadores Tumorais , Neoplasias Colorretais/genética , Metilação de DNA , DNA de Neoplasias/sangue , DNA de Neoplasias/química , Neuropeptídeo Y/genética , Proteínas Repressoras/genética , Idoso , Biomarcadores Tumorais/genética , Metilação de DNA/genética , DNA de Neoplasias/genética , Feminino , Humanos , Masculino , Reação em Cadeia da Polimerase
2.
Clin Cancer Res ; 21(5): 1087-97, 2015 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-25248381

RESUMO

PURPOSE: KRAS mutations are predictive of nonresponse to anti-EGFR therapies in metastatic colorectal cancer (mCRC). However, only 50% of nonmutated patients benefit from them. KRAS-mutated subclonal populations nondetectable by conventional methods have been suggested as the cause of early progression. Molecular analysis technology with high sensitivity and precision is required to test this hypothesis. EXPERIMENTAL DESIGN: From two cohorts of patients with mCRC, 136 KRAS, NRAS, and BRAF wild-type tumors with sufficient tumor material to perform highly sensitive picodroplet digital PCR (dPCR) and 41 KRAS-mutated tumors were selected. All these patients were treated by anti-EGFR therapy. dPCR was used for KRAS or BRAF mutation screening and compared with qPCR. Progression-free survival (PFS) and overall survival (OS) were analyzed according to the KRAS-mutated allele fraction. RESULTS: In addition to the confirmation of the 41 patients with KRAS-mutated tumors, dPCR also identified KRAS mutations in 22 samples considered as KRAS wild-type by qPCR. The fraction of KRAS-mutated allele quantified by dPCR was inversely correlated with anti-EGFR therapy response rate (P < 0.001). In a Cox model, the fraction of KRAS-mutated allele was associated with worse PFS and OS. Patients with less than 1% of mutant KRAS allele have similar PFS and OS than those with wild-type KRAS tumors. CONCLUSIONS: This study suggests that patients with mCRC with KRAS-mutated subclones (at least those with a KRAS-mutated subclones fraction lower or equal to 1%) had a benefit from anti-EGFR therapies.


Assuntos
Antineoplásicos/uso terapêutico , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/genética , Receptores ErbB/antagonistas & inibidores , Terapia de Alvo Molecular , Mutação , Proteínas Proto-Oncogênicas p21(ras)/genética , Idoso , Idoso de 80 Anos ou mais , Alelos , Antineoplásicos/farmacologia , Estudos de Coortes , Neoplasias Colorretais/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Proteínas Proto-Oncogênicas B-raf/genética , Retratamento , Resultado do Tratamento
3.
Clin Chem ; 59(12): 1722-31, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23938455

RESUMO

BACKGROUND: Multiplex digital PCR (dPCR) enables noninvasive and sensitive detection of circulating tumor DNA with performance unachievable by current molecular-detection approaches. Furthermore, picodroplet dPCR facilitates simultaneous screening for multiple mutations from the same sample. METHODS: We investigated the utility of multiplex dPCR to screen for the 7 most common mutations in codons 12 and 13 of the KRAS (Kirsten rat sarcoma viral oncogene homolog) oncogene from plasma samples of patients with metastatic colorectal cancer. Fifty plasma samples were tested from patients for whom the primary tumor biopsy tissue DNA had been characterized by quantitative PCR. RESULTS: Tumor characterization revealed that 19 patient tumors had KRAS mutations. Multiplex dPCR analysis of the plasma DNA prepared from these samples identified 14 samples that matched the mutation identified in the tumor, 1 sample contained a different KRAS mutation, and 4 samples had no detectable mutation. Among the tumor samples that were wild type for KRAS, 2 KRAS mutations were identified in the corresponding plasma samples. Duplex dPCR (i.e., wild-type and single-mutation assay) was also used to analyze plasma samples from patients with KRAS-mutated tumors and 5 samples expected to contain the BRAF (v-raf murine sarcoma viral oncogene homolog B) V600E mutation. The results for the duplex analysis matched those for the multiplex analysis for KRAS-mutated samples and, owing to its higher sensitivity, enabled detection of 2 additional samples with low levels of KRAS-mutated DNA. All 5 samples with BRAF mutations were detected. CONCLUSIONS: This work demonstrates the clinical utility of multiplex dPCR to screen for multiple mutations simultaneously with a sensitivity sufficient to detect mutations in circulating DNA obtained by noninvasive blood collection.


Assuntos
Neoplasias Colorretais/sangue , DNA/sangue , Genes ras , Mutação , Reação em Cadeia da Polimerase/métodos , Sequência de Bases , Primers do DNA , Humanos , Limite de Detecção
4.
Clin Chem ; 59(5): 815-23, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23403697

RESUMO

BACKGROUND: Assessment of DNA integrity and quantity remains a bottleneck for high-throughput molecular genotyping technologies, including next-generation sequencing. In particular, DNA extracted from paraffin-embedded tissues, a major potential source of tumor DNA, varies widely in quality, leading to unpredictable sequencing data. We describe a picoliter droplet-based digital PCR method that enables simultaneous detection of DNA integrity and the quantity of amplifiable DNA. METHODS: Using a multiplex assay, we detected 4 different target lengths (78, 159, 197, and 550 bp). Assays were validated with human genomic DNA fragmented to sizes of 170 bp to 3000 bp. The technique was validated with DNA quantities as low as 1 ng. We evaluated 12 DNA samples extracted from paraffin-embedded lung adenocarcinoma tissues. RESULTS: One sample contained no amplifiable DNA. The fractions of amplifiable DNA for the 11 other samples were between 0.05% and 10.1% for 78-bp fragments and ≤1% for longer fragments. Four samples were chosen for enrichment and next-generation sequencing. The quality of the sequencing data was in agreement with the results of the DNA-integrity test. Specifically, DNA with low integrity yielded sequencing results with lower levels of coverage and uniformity and had higher levels of false-positive variants. CONCLUSIONS: The development of DNA-quality assays will enable researchers to downselect samples or process more DNA to achieve reliable genome sequencing with the highest possible efficiency of cost and effort, as well as minimize the waste of precious samples.


Assuntos
Fragmentação do DNA , DNA de Neoplasias/análise , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Reação em Cadeia da Polimerase Multiplex/métodos , Análise de Sequência de DNA/métodos , Genoma Humano , Humanos , Neoplasias Pulmonares/química , Reprodutibilidade dos Testes
5.
Lab Chip ; 11(13): 2156-66, 2011 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-21594292

RESUMO

Somatic mutations within tumoral DNA can be used as highly specific biomarkers to distinguish cancer cells from their normal counterparts. These DNA biomarkers are potentially useful for the diagnosis, prognosis, treatment and follow-up of patients. In order to have the required sensitivity and specificity to detect rare tumoral DNA in stool, blood, lymph and other patient samples, a simple, sensitive and quantitative procedure to measure the ratio of mutant to wild-type genes is required. However, techniques such as dual probe TaqMan(®) assays and pyrosequencing, while quantitative, cannot detect less than ∼1% mutant genes in a background of non-mutated DNA from normal cells. Here we describe a procedure allowing the highly sensitive detection of mutated DNA in a quantitative manner within complex mixtures of DNA. The method is based on using a droplet-based microfluidic system to perform digital PCR in millions of picolitre droplets. Genomic DNA (gDNA) is compartmentalized in droplets at a concentration of less than one genome equivalent per droplet together with two TaqMan(®) probes, one specific for the mutant and the other for the wild-type DNA, which generate green and red fluorescent signals, respectively. After thermocycling, the ratio of mutant to wild-type genes is determined by counting the ratio of green to red droplets. We demonstrate the accurate and sensitive quantification of mutated KRAS oncogene in gDNA. The technique enabled the determination of mutant allelic specific imbalance (MASI) in several cancer cell-lines and the precise quantification of a mutated KRAS gene in the presence of a 200,000-fold excess of unmutated KRAS genes. The sensitivity is only limited by the number of droplets analyzed. Furthermore, by one-to-one fusion of drops containing gDNA with any one of seven different types of droplets, each containing a TaqMan(®) probe specific for a different KRAS mutation, or wild-type KRAS, and an optical code, it was possible to screen the six common mutations in KRAS codon 12 in parallel in a single experiment.


Assuntos
Análise Mutacional de DNA/instrumentação , Análise Mutacional de DNA/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Mutação/genética , Alelos , Linhagem Celular Tumoral , Códon/genética , Genes ras/genética , Humanos , Reação em Cadeia da Polimerase , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Nano Lett ; 11(3): 1351-7, 2011 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-21306128

RESUMO

Solvent vapor annealing (SVA) with solvent mixtures is a promising approach for controlling block copolymer thin film self-assembly. In this work, we present the design and fabrication of a solvent-resistant microfluidic mixing device to produce discrete SVA gradients in solvent composition and/or total solvent concentration. Using this device, we identified solvent composition dependent morphology transformations in poly(styrene-b-isoprene-b-styrene) films. This device enables faster and more robust exploration of SVA parameter space, providing insight into self-assembly phenomena.

7.
Nat Biotechnol ; 27(11): 1025-31, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19881494

RESUMO

Targeted enrichment of specific loci of the human genome is a promising approach to enable sequencing-based studies of genetic variation in large populations. Here we describe an enrichment approach based on microdroplet PCR, which enables 1.5 million amplifications in parallel. We sequenced six samples enriched by microdroplet or traditional singleplex PCR using primers targeting 435 exons of 47 genes. Both methods generated similarly high-quality data: 84% of the uniquely mapping reads fell within the targeted sequences; coverage was uniform across approximately 90% of targeted bases; sequence variants were called with >99% accuracy; and reproducibility between samples was high (r(2) = 0.9). We scaled the microdroplet PCR to 3,976 amplicons totaling 1.49 Mb of sequence, sequenced the resulting sample with both Illumina GAII and Roche 454, and obtained data with equally high specificity and sensitivity. Our results demonstrate that microdroplet technology is well suited for processing DNA for massively parallel enrichment of specific subsets of the human genome for targeted sequencing.


Assuntos
Microfluídica/métodos , Reação em Cadeia da Polimerase/métodos , Análise de Sequência de DNA/métodos , Sequência de Bases , Humanos , Mutação/genética , Reprodutibilidade dos Testes , Análise de Sequência de DNA/instrumentação
8.
Proc Natl Acad Sci U S A ; 106(34): 14195-200, 2009 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-19617544

RESUMO

We present a droplet-based microfluidic technology that enables high-throughput screening of single mammalian cells. This integrated platform allows for the encapsulation of single cells and reagents in independent aqueous microdroplets (1 pL to 10 nL volumes) dispersed in an immiscible carrier oil and enables the digital manipulation of these reactors at a very high-throughput. Here, we validate a full droplet screening workflow by conducting a droplet-based cytotoxicity screen. To perform this screen, we first developed a droplet viability assay that permits the quantitative scoring of cell viability and growth within intact droplets. Next, we demonstrated the high viability of encapsulated human monocytic U937 cells over a period of 4 days. Finally, we developed an optically-coded droplet library enabling the identification of the droplets composition during the assay read-out. Using the integrated droplet technology, we screened a drug library for its cytotoxic effect against U937 cells. Taken together our droplet microfluidic platform is modular, robust, uses no moving parts, and has a wide range of potential applications including high-throughput single-cell analyses, combinatorial screening, and facilitating small sample analyses.


Assuntos
Microfluídica/instrumentação , Microfluídica/métodos , Sobrevivência Celular/efeitos dos fármacos , Avaliação Pré-Clínica de Medicamentos/métodos , Emulsões , Corantes Fluorescentes/química , Humanos , Técnicas Analíticas Microfluídicas/métodos , Mitomicina/química , Mitomicina/farmacologia , Reprodutibilidade dos Testes , Fatores de Tempo , Células U937
9.
Anal Chem ; 81(12): 4813-21, 2009 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-19518143

RESUMO

We have developed a method for high-throughput isothermal amplification of single DNA molecules in a droplet-based microfluidic system. DNA amplification in droplets was analyzed using an intercalating fluorochrome, allowing fast and accurate "digital" quantification of the template DNA based on the Poisson distribution of DNA molecules in droplets. The clonal amplified DNA in each 2 pL droplet was further analyzed by measuring the enzymatic activity of the encoded proteins after fusion with a 15 pL droplet containing an in vitro translation system.


Assuntos
DNA/análise , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas de Amplificação de Ácido Nucleico/métodos , Substâncias Intercalantes/química , Técnicas Analíticas Microfluídicas/métodos , Temperatura
10.
Lab Chip ; 9(13): 1850-8, 2009 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-19532959

RESUMO

We describe a highly efficient microfluidic fluorescence-activated droplet sorter (FADS) combining many of the advantages of microtitre-plate screening and traditional fluorescence-activated cell sorting (FACS). Single cells are compartmentalized in emulsion droplets, which can be sorted using dielectrophoresis in a fluorescence-activated manner (as in FACS) at rates up to 2000 droplets s(-1). To validate the system, mixtures of E. coli cells, expressing either the reporter enzyme beta-galactosidase or an inactive variant, were compartmentalized with a fluorogenic substrate and sorted at rates of approximately 300 droplets s(-1). The false positive error rate of the sorter at this throughput was <1 in 10(4) droplets. Analysis of the sorted cells revealed that the primary limit to enrichment was the co-encapsulation of E. coli cells, not sorting errors: a theoretical model based on the Poisson distribution accurately predicted the observed enrichment values using the starting cell density (cells per droplet) and the ratio of active to inactive cells. When the cells were encapsulated at low density ( approximately 1 cell for every 50 droplets), sorting was very efficient and all of the recovered cells were the active strain. In addition, single active droplets were sorted and cells were successfully recovered.


Assuntos
Escherichia coli/enzimologia , Escherichia coli/isolamento & purificação , Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Microfluídica/instrumentação , beta-Galactosidase/metabolismo , Emulsões/química , Desenho de Equipamento , Escherichia coli/genética , Citometria de Fluxo/economia , Corantes Fluorescentes , Galactose/metabolismo , Microfluídica/economia , Microfluídica/métodos , beta-Galactosidase/genética
11.
Langmuir ; 21(23): 10814-7, 2005 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-16262357

RESUMO

The morphology of self-assembled phospholipid membranes (e.g., micelles, vesicles, rods, tubes, etc.) depends on the method of formation, secondary manipulation, temperature, and storage conditions. In this contribution, microfluidic systems are used to create pure phosphatidylcholine (PC) micro- and nanotubes with unprecedented lengths. Tubes up to several centimeters in length and aligned with the long axis of the microchannel were created from spots of dry films of 1,2-dilauroyl-sn-glycero-3-phosphocholine (DLPC), 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC), and 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC). These high aspect ratio structures, which, to our knowledge, represent the first examples of extended tubes formed from pure PC lipids, were examined by fluorescence microscopy, electron and optical microscopy, and optical manipulation tools (i.e., a laser trap and laser scalpel) to characterize structure and stability. In particular, the tubular structure was confirmed by observation of fluorescent dyes that were sequestered within the aqueous cavity or within the phospholipid tube. Compared to other phospholipid tubes, the tubes formed from PC lipids in microfluidic channels show high mechanical stability and rigidity that depend on tube size, age, and storage conditions.


Assuntos
Microfluídica/instrumentação , Nanotubos , Fosfatidilcolinas/química , Microscopia de Fluorescência
12.
Lab Chip ; 4(6): 658-62, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15570381

RESUMO

Microfluidic devices are commonly fabricated in silicon or glass using micromachining technology or elastomers using soft lithography methods; however, invariable bulk material properties, limited surface modification methods and difficulty in fabricating high aspect ratio devices prevent these materials from being utilized in numerous applications and/or lead to high fabrication costs. Contact Liquid Photolithographic Polymerization (CLiPP) was developed as an alternative microfabrication approach that uniquely exploits living radical photopolymerization chemistry to facilitate surface modification of device components, fabrication of high aspect ratio structures from many different materials with numerous covalently-adhered layers and facile construction of three-dimensional devices. This contribution describes CLiPP and demonstrates unique advantages of this new technology for microfabrication of polymeric microdevices. Specifically, the procedure for fabricating devices with CLiPP is presented, the living radical photopolymerization chemistry which enables this technology is described, and examples of devices made using CLiPP are shown.


Assuntos
Desenho de Equipamento/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Fotoquímica/métodos , Fotografação/métodos , Polímeros/química , Polímeros/efeitos da radiação , Análise de Falha de Equipamento , Luz , Soluções
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA