Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Radiology ; 308(1): e230052, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37404152

RESUMO

Background Lung MRI with ultrashort echo times (UTEs) enables high-resolution and radiation-free morphologic imaging; however, its image quality is still lower than that of CT. Purpose To assess the image quality and clinical applicability of synthetic CT images generated from UTE MRI by a generative adversarial network (GAN). Materials and Methods This retrospective study included patients with cystic fibrosis (CF) who underwent both UTE MRI and CT on the same day at one of six institutions between January 2018 and December 2022. The two-dimensional GAN algorithm was trained using paired MRI and CT sections and tested, along with an external data set. Image quality was assessed quantitatively by measuring apparent contrast-to-noise ratio, apparent signal-to-noise ratio, and overall noise and qualitatively by using visual scores for features including artifacts. Two readers evaluated CF-related structural abnormalities and used them to determine clinical Bhalla scores. Results The training, test, and external data sets comprised 82 patients with CF (mean age, 21 years ± 11 [SD]; 42 male), 28 patients (mean age, 18 years ± 11; 16 male), and 46 patients (mean age, 20 years ± 11; 24 male), respectively. In the test data set, the contrast-to-noise ratio of synthetic CT images (median, 303 [IQR, 221-382]) was higher than that of UTE MRI scans (median, 9.3 [IQR, 6.6-35]; P < .001). The median signal-to-noise ratio was similar between synthetic and real CT (88 [IQR, 84-92] vs 88 [IQR, 86-91]; P = .96). Synthetic CT had a lower noise level than real CT (median score, 26 [IQR, 22-30] vs 42 [IQR, 32-50]; P < .001) and the lowest level of artifacts (median score, 0 [IQR, 0-0]; P < .001). The concordance between Bhalla scores for synthetic and real CT images was almost perfect (intraclass correlation coefficient, ≥0.92). Conclusion Synthetic CT images showed almost perfect concordance with real CT images for the depiction of CF-related pulmonary alterations and had better image quality than UTE MRI. Clinical trial registration no. NCT03357562 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Schiebler and Glide-Hurst in this issue.


Assuntos
Fibrose Cística , Adolescente , Adulto , Humanos , Masculino , Adulto Jovem , Fibrose Cística/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Feminino , Criança
2.
Eur Radiol ; 33(8): 5528-5539, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37071165

RESUMO

OBJECTIVES: To compare lung parenchyma analysis on ultra-high resolution (UHR) images of a photon-counting CT (PCCT) scanner with that of high-resolution (HR) images of an energy-integrating detector CT (EID-CT). METHODS: A total of 112 patients with stable interstitial lung disease (ILD) were investigated (a) at T0 with HRCT on a 3rd-generation dual-source CT scanner; (b) at T1 with UHR on a PCCT scanner; (c) with a comparison of 1-mm-thick lung images. RESULTS: Despite a higher level of objective noise at T1 (74.1 ± 14.1 UH vs 38.1 ± 8.7 UH; p < 0.0001), higher qualitative scores were observed at T1 with (a) visualization of more distal bronchial divisions (median order; Q1-Q3) (T1: 10th division [9-10]; T0: 9th division [8-9]; p < 0.0001); (b) greater scores of sharpness of bronchial walls (p < 0.0001) and right major fissure (p < 0.0001). The scores of visualization of CT features of ILD were significantly superior at T1 (micronodules: p = 0.03; linear opacities, intralobular reticulation, bronchiectasis, bronchiolectasis, and honeycombing: p < 0.0001), leading to the reclassification of 4 patients with non-fibrotic ILD at T0, recognized with fibrotic ILD at T1. At T1, the mean (± SD) radiation dose (CTDI vol: 2.7 ± 0.5 mGy; DLP: 88.5 ± 21 mGy.cm) was significantly lower than that delivered at T0 (CTDI vol: 3.6 ± 0.9 mGy; DLP: 129.8 ± 31.7 mGy.cm) (p < 0.0001), corresponding to a mean reduction of 27% and 32% for the CTDIvol and DLP, respectively. CONCLUSIONS: The UHR scanning mode of PCCT allowed a more precise depiction of CT features of ILDs and reclassification of ILD patterns with significant radiation dose reduction. CLINICAL RELEVANCE STATEMENT: Evaluation of lung parenchymal structures with ultra-high-resolution makes subtle changes at the level of the secondary pulmonary lobules and lung microcirculation becoming visually accessible, opening new options for synergistic collaborations between highly-detailed morphology and artificial intelligence. KEY POINTS: • Photon-counting CT (PCCT) provides a more precise analysis of lung parenchymal structures and CT features of interstitial lung diseases (ILDs). • The UHR mode ensures a more precise delineation of fine fibrotic abnormalities with the potential of modifying the categorization of ILD patterns. • Better image quality at a lower radiation dose with PCCT opens new horizons for further dose reduction in noncontrast UHR examinations.


Assuntos
Doenças Pulmonares Intersticiais , Pulmão , Tomografia Computadorizada por Raios X , Humanos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Fótons , Pulmão/diagnóstico por imagem , Inteligência Artificial
3.
Invest Radiol ; 58(7): 482-487, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-36897831

RESUMO

ABSTRACT: After a decade of preclinical testing, photon-counting computed tomography (PCCT) has now entered daily routine, enabling radiologists to start investigating thoracic disorders in unprecedented conditions. The improved spatial resolution of the ultra-high-resolution (UHR) scanning mode is a major step for the analysis of bronchopulmonary disorders, making abnormalities at the level of small anatomical structures such as secondary pulmonary lobules accessible to radiologists. Distal divisions of pulmonary and systemic vessels also benefit from UHR protocols as alterations of lung microcirculation were previously excluded from confident analysis with energy-integrating detector CT. Although noncontrast chest CT examinations were the initial target of UHR protocols, the clinical value of this mode is also applicable to chest CT angiographic examinations with improved morphological evaluation and higher-quality lung perfusion imaging. The clinical benefits of UHR have been evaluated in initial studies, allowing radiologists to foresee the field of future applications, all combining high diagnostic value and radiation dose reduction. The purpose of this article is to highlight the technological information relevant to daily practice and to review the current clinical applications in the field of chest imaging.


Assuntos
Tórax , Tomografia Computadorizada por Raios X , Angiografia por Tomografia Computadorizada , Pulmão , Imagens de Fantasmas , Fótons , Tomografia Computadorizada por Raios X/métodos
4.
Semin Respir Crit Care Med ; 43(6): 936-945, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36307107

RESUMO

Chronic thromboembolic pulmonary hypertension (CTEPH) and chronic thromboembolic pulmonary disease (CTEPD) are two terms characterizing symptomatic patients with chronic thromboembolic occlusions of pulmonary arteries with or without pulmonary hypertension at rest. Their diagnosis follows evolving schemas that integrate technological advances of pivotal imaging modalities among which computed tomography angiography plays a major role. This review article summarizes the current knowledge on the natural history of acute pulmonary embolism and its evolution toward chronic pulmonary embolism, as well as the imaging clues, for the identification of chronically obstructed pulmonary arteries. The requirements for imaging at the time of therapeutic decisions are also described in the light of recent updates in the literature from multidisciplinary groups of experts. Because an early diagnosis of CTEPH remains a challenge for the medical community, several practical issues are included in this article with the objective of improving the knowledge and collaboration between radiologists and clinicians in service to the patient.


Assuntos
Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/efeitos adversos , Tomografia Computadorizada por Raios X , Doença Crônica
5.
Acad Radiol ; 29 Suppl 2: S202-S214, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34446359

RESUMO

PURPOSE: To compare dual-energy (DE) lung perfused blood volume generated by subtraction of virtual monoenergetic images (Lung Mono) with images obtained by three-compartment decomposition (Lung PBV). MATERIAL AND METHODS: The study included 58 patients (28 patients with and 30 patients without PE) with reconstruction of Lung PBV images (i.e., the reference standard) and Lung Mono images. The inter-technique comparison was undertaken at a patient and segment level. RESULTS: The distribution of scores of subjective image noise (patient level) significantly differed between the two reconstructions (p<0.0001), with mild noise in 58.6% (34/58) of Lung Mono images vs 25.9% (15/58) of Lung PBV images. Detection of perfusion defects (segment level) was concordant in 1104 segments (no defect: n=968; defects present: n=138) and discordant in 2 segments with a PE-related defect only depicted on Lung Mono images. Among the 28 PE patients, the distribution of gradient of attenuation between perfused areas and defects was significantly higher on Lung Mono images compared to Lung PBV (median= 73.5 HU (QI=65.0; Q3=86.0) vs 24.5 HU (22.0; 30.0); p<0.0001). In all patients, fissures were precisely identified in 77.6% of patients (45/58) on Lung Mono images while blurred (30/58; 51.7%) or not detectable (28/58; 48.3%) on Lung PBV images. CONCLUSION: Lung Mono perfusion imaging allows significant improvement in the overall image quality and improved detectability of PE-type perfusion defects.


Assuntos
Embolia Pulmonar , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Pulmão/diagnóstico por imagem , Perfusão , Imagem de Perfusão , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
6.
J Thorac Imaging ; 35 Suppl 1: S40-S48, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32271281

RESUMO

The radiologic community is rapidly integrating a revolution that has not fully entered daily practice. It necessitates a close collaboration between computer scientists and radiologists to move from concepts to practical applications. This article reviews the current littérature on machine learning and deep neural network applications in the field of pulmonary embolism, chronic thromboembolic pulmonary hypertension, aorta, and chronic obstructive pulmonary disease.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Hipertensão Pulmonar/diagnóstico por imagem , Aprendizado de Máquina , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Aorta/diagnóstico por imagem , Doença Crônica , Humanos , Redes Neurais de Computação
7.
Acta Paediatr ; 109(6): 1221-1228, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31710383

RESUMO

AIM: Oesophageal atresia is frequently associated with other malformations, and our aim was to use computed tomography (CT) to explore intrathoracic malformations in patients with this condition. METHOD: This was retrospective study of children aged 0-16 with oesophageal atresia who were born in 1996-2013 and followed up at the French reference centre for rare oesophageal diseases at the University of Lille. Computed tomography scans were available for 48 of the 234 patients during follow-up visits, and these were reviewed by a thoracic radiologist. RESULTS: More than two-thirds of the scans were performed to explore persistent respiratory symptoms. We found that six patients had a pulmonary malformations: four lobar agenesis, one right pulmonary aplasia and one congenital cystic adenomatoid malformation. Computed tomography enabled us to diagnose unexpected thoracic malformations in 16 patients: four lobar agenesis, six arteria lusoria, five persistent left superior vena cava and one partial anomalous pulmonary venous return. It also confirmed the diagnoses of suspected malformations in five patients: one congenital cystic adenomatoid malformation, one pulmonary hypoplasia, two right-sided aortic arches and one communicating bronchopulmonary foregut malformation. CONCLUSION: Intrathoracic anomalies were frequently associated with oesophageal atresia, and contrast-enhanced chest CT scans should be performed on patients with persistent respiratory symptoms.


Assuntos
Malformação Adenomatoide Cística Congênita do Pulmão , Atresia Esofágica , Adolescente , Adulto , Criança , Pré-Escolar , Atresia Esofágica/complicações , Atresia Esofágica/diagnóstico por imagem , Atresia Esofágica/epidemiologia , Humanos , Lactente , Recém-Nascido , Pulmão , Estudos Retrospectivos , Veia Cava Superior
8.
Eur Radiol ; 26(6): 1521-8, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26340814

RESUMO

PURPOSE: To investigate the reliability of ungated, high-pitch dual-source CT for coronary artery calcium (CAC) screening. MATERIALS AND METHODS: One hundred and eighty-five smokers underwent a dual-source CT examination with acquisition of two sets of images during the same session: (a) ungated, high-pitch and high-temporal resolution acquisition over the entire thorax (i.e., chest CT); (b) prospectively ECG-triggered acquisition over the cardiac cavities (i.e., cardiac CT). RESULTS: Sensitivity and specificity of chest CT for detecting positive CAC scores were 96.4 % and 100 %, respectively. There was excellent inter-technique agreement for determining the quantitative CAC score (ICC = 0.986). The mean difference between the two techniques was 11.27, representing 1.81 % of the average of the two techniques. The inter-technique agreement for categorizing patients into the four ranks of severity was excellent (weighted kappa = 0.95; 95 % CI 0.93-0.98). The inter-technique differences for quantitative CAC scores did not correlate with BMI (r = 0.05, p = 0.575) or heart rate (r = -0.06, p = 0.95); 87.2 % of them were explained by differences at the level of the right coronary artery (RCA: 0.8718; LAD: 0.1008; LCx: 0.0139; LM: 0.0136). CONCLUSION: Ungated, high-pitch dual-source CT is a reliable imaging mode for CAC screening in the conditions of routine chest CT examinations. KEY POINTS: • CAC is an independent risk factor for major cardiac events. • ECG-gated techniques are the reference standard for calcium scoring. • Great interest is directed toward calcium scoring on non-gated chest CT examinations. • Reliable calcium scoring can be obtained with dual-source CT in a high-pitch mode.


Assuntos
Calcinose/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Vasos Coronários/diagnóstico por imagem , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
9.
Eur Radiol ; 26(2): 469-77, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26037717

RESUMO

PURPOSE: To evaluate the influence of temporal resolution (TR) on cardiogenic artefacts at the level of bronchial walls. MATERIAL AND METHODS: Ninety patients underwent a dual-source, single-energy chest CT examination enabling reconstruction of images with a TR of 75 ms (i.e., optimized TR) (Group 1) and 140 ms (i.e., standard TR) (Group 2). Cardiogenic artefacts were analyzed at the level of eight target bronchi, i.e., right (R) and left (L) B1, B5, B7, and B10 (total number of bronchi examined: n = 720). RESULTS: Cardiogenic artefacts were significantly less frequent and less severe in Group 1 than in Group 2 (p < 0.0001) with the highest scores of discordant ratings for bronchi in close contact with cardiac cavities: RB5 (61/90; 68%); LB5 (66/90; 73%); LB7 (63/90; 70%). In Group 1, 78% (560/720) of bronchi showed no cardiac motion artefacts, whereas 22% of bronchi (160/720) showed artefacts rated as mild (152/160; 95%), moderate (7/160; 4%), and severe (1/160; 1%). In Group 2, 70% of bronchi (503/720) showed artefacts rated as mild (410/503; 82%), moderate (82/503; 16%), and severe (11/503; 2%). CONCLUSION: At 75 ms, most bronchi can be depicted without cardiogenic artefacts. KEY POINTS: • Quantitative CT helps analyze morphologic changes in COPD patients • Cardiogenic artefacts may hamper precise analysis of bronchial dimensions • Temporal resolution of CT acquisitions is an important parameter for bronchial imaging.


Assuntos
Artefatos , Brônquios , Broncografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tempo , Adulto Jovem
10.
Pediatr Radiol ; 45(12): 1761-70, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26293229

RESUMO

BACKGROUND: Dual-source CT allows scanning of the chest with high pitch and high temporal resolution, which can improve the detection of proximal coronary arteries in infants and young children when scanned without general anesthesia, sedation or beta-blockade. OBJECTIVE: To compare coronary artery visibility between higher and standard temporal resolution. MATERIALS AND METHODS: We analyzed CT images in 93 children who underwent a standard chest CT angiographic examination with reconstruction of images with a temporal resolution of 75 ms (group 1) and 140 ms (group 2). RESULTS: The percentage of detected coronary segments was higher in group 1 than in group 2 when considering all segments (group 1: 27%; group 2: 24%; P = 0.0004) and proximal segments (group 1: 37%; group 2: 32%; P = 0.0006). In both groups, the highest rates of detection were observed for the left main coronary artery (S1) (group 1: 65%; group 2: 58%) and proximal left anterior descending coronary artery (S2) (group 1: 43%; group 2: 42%). Higher rates of detection were seen in group 1 for the left main coronary artery (P = 0.03), proximal right coronary artery (P = 0.01), proximal segments of the left coronary artery (P = 0.02) and proximal segments of the left and right coronary arteries (P = 0.0006). CONCLUSION: Higher temporal resolution improved the visibility of proximal coronary arteries in pediatric chest CT.


Assuntos
Angiografia Coronária/métodos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Reprodutibilidade dos Testes , Respiração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA