Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38441415

RESUMO

Two novel bacterial strains, designated as COR-2T and CR-8, were isolated from paddy soil. These isolates were aerobic, Gram-stain-negative, non-spore-forming, non-motile, rod-shaped, and formed orange-coloured colonies. Phylogenetic analysis based on 16S rRNA gene sequences showed that two strains formed a clear phylogenetic lineage with the genus Erythrobacter. Strains COR-2T and CR-8 showed 99.9 % 16S rRNA gene sequence similarity. Both strains had the highest 16S rRNA gene similarity of 99.1-99.7 % to Erythrobacter colymbi TPW-24T, Erythrobacter donghaensis SW-132T and Erythrobacter tepidarius DSM 10594T, respectively. The genome of strain COR-2T comprised 3 559 918 bp and the genomic DNA G + C content was 67.7 mol%. The average nucleotide identity and digital DNA-DNA hybridization values between strain COR-2T and its closely related species of the genus Erythrobacter were 79.3-85.5% and 24.1-29.1 %, respectively. The major respiratory quinone was Q-10, while the major fatty acids were C18 : 1 ω7c and C17 : 1 ω6c. The major polar lipids were phosphatidylethanolamine, phosphatidylglycerol, phosphatidylcholine, two unidentified phospholipids and eight unidentified lipids. Based on phylogenetic and phenotypic considerations, the two strains [COR-2T (type strain; = KACC 22941T=JCM 35529T) and CR-8 (= KACC 22945=JCM 35530)] are considered to represent novel species of the genus Erythrobacter, for which the name Erythrobacter oryzae sp. nov. is proposed.


Assuntos
Oryza , Sphingomonadaceae , Filogenia , RNA Ribossômico 16S/genética , Composição de Bases , Ácidos Graxos/química , Análise de Sequência de DNA , DNA Bacteriano/genética , Técnicas de Tipagem Bacteriana
2.
Sensors (Basel) ; 22(22)2022 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-36433221

RESUMO

Real-time Polymerase Chain Reaction (RT-PCR), a molecular diagnostic technology, is spotlighted as one of the quickest and fastest diagnostic methods for the actual coronavirus (SARS-CoV-2). However, the fluorescent label-based technology of the RT-PCR technique requires expensive equipment and a sample pretreatment process for analysis. Therefore, this paper proposes a biochip based on Electrochemical Impedance Spectroscopy (EIS). In this paper, it was possible to see the change according to the concentration by measuring the impedance with a chip made of two electrodes with different shapes of sample DNA.


Assuntos
COVID-19 , Amplificação de Genes , Humanos , RNA Viral/análise , SARS-CoV-2/genética , COVID-19/diagnóstico , Eletrodos
3.
Sensors (Basel) ; 21(20)2021 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-34695940

RESUMO

With the active development of mobile devices, a variety of ultra-small, high-definition, and open platform-based cameras are being mass-produced. In this paper, we established an emulation system to verify the bio-imaging performance of the bulky and expensive high-performance cameras and various smartphone cameras that have been used in bio-imaging devices. In the proposed system, the linearity of the brightness gradient change of four types of cameras was compared and analyzed. Based on these results, three cameras were selected in order of excellent linearity, and gel image analysis results were compared.


Assuntos
Processamento de Imagem Assistida por Computador , Smartphone , Computadores de Mão , Diagnóstico por Imagem
4.
Sensors (Basel) ; 21(11)2021 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-34204136

RESUMO

Most existing commercial real-time polymerase chain reaction (RT-PCR) instruments are bulky because they contain expensive fluorescent detection sensors or complex optical structures. In this paper, we propose an RT-PCR system using a camera module for smartphones that is an ultra small, high-performance and low-cost sensor for fluorescence detection. The proposed system provides stable DNA amplification. A quantitative analysis of fluorescence intensity changes shows the camera's performance compared with that of commercial instruments. Changes in the performance between the experiments and the sets were also observed based on the threshold cycle values in a commercial RT-PCR system. The overall difference in the measured threshold cycles between the commercial system and the proposed camera was only 0.76 cycles, verifying the performance of the proposed system. The set calibration even reduced the difference to 0.41 cycles, which was less than the experimental variation in the commercial system, and there was no difference in performance.


Assuntos
Técnicas de Amplificação de Ácido Nucleico , Smartphone , Análise de Sequência com Séries de Oligonucleotídeos , Reação em Cadeia da Polimerase em Tempo Real
5.
Nanomaterials (Basel) ; 9(8)2019 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-31426388

RESUMO

Titanium dioxide (TiO2) is one of the most extensively utilized food additives (E171) in the food industry. Along with nanotechnology development, the concern about the presence of nanostructured particles in E171 TiO2 and commercial food products is growing. In the present study, the physicochemical properties of commercially available E171 TiO2 particles, including particle size distribution, were investigated, followed by their cytotoxicity and intestinal transport evaluation. The fate determination and quantification of E171 TiO2 in commercial foods were carried out based on the analytical procedure developed using simulated foods. The results demonstrated that TiO2 is a material mainly composed of particles larger than 100 nm, but present as an agglomerated or aggregated particle in commercial foods with amounts of less than 1% (wt/wt). Titanium dioxide particles generated reactive oxygen species and inhibited long-term colony formation, but the cytotoxicity was not related to particle size distribution or particle type (food- or general-grade). All TiO2 particles were mainly transported by microfold (M) cells, but also by intestinal tight junction. These findings will be useful for TiO2 application in the food industry and predicting its potential toxicity.

6.
Biomed Eng Online ; 17(Suppl 2): 156, 2018 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-30396352

RESUMO

BACKGROUND: Polymerase chain reaction (PCR) is used in nucleic acid tests of infectious diseases in point-of-care testing. Previous studies have demonstrated real-time PCR that uses a micro-PCR chip made of packing tape, double-sided tape, and a plastic cover with polycarbonate or polypropylene on a black matte printed circuit board substrate. Despite the success of DNA amplification and fluorescence detection using an early version of the micro-PCR chip, reaching the target temperature was fairly slow and, as a result, the total running time was getting longer. To reduce this runtime, the micro-PCR chip was modified by reducing the heater pattern size of the PCB substrate to one-quarter of the original size or less, while maintaining the ability of the heating pattern to cover the reservoir area of the microfluidic channel. In subsequent experiments, DNA amplification failed several times. During the analysis of the cause of this failure, it was found that the reagent was boiling with the heating range from 25 to 95 °C. METHODS: As a method of DNA amplification verification, images were captured by digital single-lens reflex camera to detect FAM fluorescence using diagonal illumination from a blue LED light source. The images were automatically captured at 72 °C (the extension step in nucleic acid amplification) and the brightness of the captured images was analyzed to con-firm the success of DNA amplification. RESULTS: Compared to the previous chip with a larger heating pattern size, the current chip appears to generate excess energy as the size of the heating pattern was reduced. To reduce this excess energy, the initial voltage was lowered to 2 V and 2.5 V, which is equivalent to a one-fifth and one-quarter voltage-power reduction in pulse width modulation control, respectively. In both voltage reduction cases, the DNA amplification was successful. CONCLUSIONS: DNA amplification tests may fail due to the excess energy generated by reducing the heater pattern size of the PCB substrate. However, the tests succeeded when the voltage was reduced to 2 V or 2.5 V. The 2.5 V power test was more efficient for reducing the overall running time.


Assuntos
Eletricidade , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , Dispositivos Lab-On-A-Chip
7.
Technol Health Care ; 24 Suppl 1: S139-46, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26409548

RESUMO

This paper proposes the optimal structure of a PCB-based micro PCR chip constructed on a PCB substrate using commercial adhesive tapes and plastic covers. The solder mask of the PCB substrate was coated black, and the area where the reaction chamber is attached was legend printed with white silk to minimize the noise during fluorescence detection. The performance of the PCR and fluorescence detection was compared using 6 types of reaction chambers, each made with different double-sided tapes. Three of the chambers were unsuccessful in completing the PCR. The performance of the other three chambers that successfully amplified DNA was compared using Taqman probe for Chlamydia Trachomatis DNA. The amplified product was illuminated diagonally with a blue LED to excite the product just before imaging, and the LED was turned off when the image was captured to prevent quenching of the probe. The images were taken 10 seconds prior to the last extension step for each cycle using a DSLR camera. The experiments were run as a quartet for each three chambers made with different double-sided tape. The results showed that there were significant difference between the three tapes.


Assuntos
Adesivos , DNA/análise , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Reação em Cadeia da Polimerase/instrumentação , Reação em Cadeia da Polimerase/métodos , Fluorescência , Humanos
8.
Med Biol Eng Comput ; 46(6): 621-4, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18259792

RESUMO

A tracking method is presented here for an in vivo robotic capsule with power supplied from one of the multiple power transmission coils. The proposed method aims to select the best coupled coil among the array of power transmission coils. It relies on the fact that the driving current of the power transmitter increases with inductive coupling of the receiver coil inside the capsule with the transmitter coil. Investigation of the current increase characteristic according to its location relative to the transmission coils allows development of a strategy for the in vivo robotic capsule. This study shows results with two transmission coils and a two-dimensional power receiver. Experimental results present the possibility of selecting the best coil by estimating the relative location of the capsule.


Assuntos
Cápsulas Endoscópicas , Endoscopia por Cápsula/métodos , Fontes de Energia Elétrica , Humanos , Intestinos , Magnetismo , Robótica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA