Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Med Biol Eng Comput ; 61(12): 3363-3385, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37672143

RESUMO

Automatic seizure detection and prediction using clinical Electroencephalograms (EEGs) are challenging tasks due to factors such as low Signal-to-Noise Ratios (SNRs), high variance in epileptic seizures among patients, and limited clinical data constraints. To overcome these challenges, this paper presents two approaches for EEG signal classification. One of these approaches depends on Machine Learning (ML) tools. The used features are different types of entropy, higher-order statistics, and sub-band energies in the Hilbert Marginal Spectrum (HMS) domain. The classification is performed using Support Vector Machine (SVM), Logistic Regression (LR), and K-Nearest Neighbor (KNN) classifiers. Both seizure detection and prediction scenarios are considered. The second approach depends on spectrograms of EEG signal segments and a Convolutional Neural Network (CNN)-based residual learning model. We use 10000 spectrogram images for each class. In this approach, it is possible to perform both seizure detection and prediction in addition to a 3-state classification scenario. Both approaches are evaluated on the Children's Hospital Boston and the Massachusetts Institute of Technology (CHB-MIT) dataset, which contains 24 EEG recordings for 6 males and 18 females. The results obtained for the HMS-based model showed an accuracy of 100%. The CNN-based model achieved accuracies of 97.66%, 95.59%, and 94.51% for Seizure (S) versus Pre-Seizure (PS), Non-Seizure (NS) versus S, and NS versus S versus PS classes, respectively. These results demonstrate that the proposed approaches can be effectively used for seizure detection and prediction. They outperform the state-of-the-art techniques for automatic seizure detection and prediction. Block diagram of proposed epileptic seizure detection method using HMS with different classifiers.


Assuntos
Epilepsia , Convulsões , Masculino , Criança , Feminino , Humanos , Convulsões/diagnóstico , Epilepsia/diagnóstico , Redes Neurais de Computação , Eletroencefalografia/métodos , Máquina de Vetores de Suporte , Processamento de Sinais Assistido por Computador , Algoritmos
2.
Plants (Basel) ; 12(10)2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37653895

RESUMO

Minimizing the consumption of agrochemicals, particularly nitrogen, is the ultimate goal for achieving sustainable agricultural production with low cost and high economic and environmental returns. The use of biopolymers instead of petroleum-based synthetic polymers for CRFs can significantly improve the sustainability of crop production since biopolymers are biodegradable and not harmful to soil quality. Lignin is one of the most abundant biopolymers that naturally exist.In this study, controlled-release fertilizers were developed using a biobased nanocomposite of lignin and bentonite clay mineral as a coating material for urea to increase nitrogen use efficiency. Five types of controlled-release urea (CRU) were prepared using two ratios of modified bentonite as well as techniques. The efficiency of the five controlled-release nano-urea (CRU) fertilizers in improving the growth of tomato plants was studied under field conditions. The CRU was applied to the tomato plants at three N levels representing 100, 50, and 25% of the recommended dose of conventional urea. The results showed that all CRU treatments at the three N levels significantly enhanced plant growth parameters, including plant height, number of leaves, fresh weight, and dry weight, compared to the control. Additionally, most CRU fertilizers increased total yield and fruit characteristics (weight, length, and diameter) compared to the control. Additionally, marketable yield was improved by CRU fertilizers. Fruit firmness and acidity of CRU treatments at 25 and 50% N levels were much higher than both the 100% CRU treatment and the control. The vitamin C values of all CRU treatments were lower than the control. Nitrogen uptake efficiencies (NUpE) of CRU treatments were 47-88%, which is significantly higher than that of the control (33%). In conclusion, all CRU treatments at an N level of 25% of the recommended dose showed better plant growth, yield, and fruit quality of tomatoes than the conventional fertilizer.

3.
Nanomaterials (Basel) ; 13(12)2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37368319

RESUMO

Crop production faces challenges in achieving high fertilizer use efficiency. To address this issue, slow-release fertilizers (SRFs) have emerged as effective solutions to minimize nutrient losses caused by leaching, runoff, and volatilization. In addition, replacing petroleum-based synthetic polymers with biopolymers for SRFs offers substantial benefits in terms of sustainability of crop production and soil quality preservation, as biopolymers are biodegradable and environmentally friendly. This study focuses on modifying a fabrication process to develop a bio-composite comprising biowaste lignin and low-cost montmorillonite clay mineral for encapsulating urea to create a controllable release fertilizer (CRU) with a prolonged nitrogen release function. CRUs containing high N contents of 20 to 30 wt.% were successfully and extensively characterized using X-Ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), and Scanning Electron Microscopy (SEM). The results showed that the releases of N from CRUs in water and soil extended to considerably long periods of 20 and 32 days, respectively. The significance of this research is the production of CRU beads that contain high N percentages and have a high soil residence period. These beads can enhance plant nitrogen utilization efficiency, reduce fertilizer consumption, and ultimately contribute to agricultural production.

4.
Int J Numer Method Biomed Eng ; 38(6): e3573, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35077027

RESUMO

Electroencephalography (EEG) is among the main tools used for analyzing and diagnosing epilepsy. The manual analysis of EEG must be conducted by highly trained clinicians or neuro-physiologists; a process that is considered to have a comparatively low inter-rater agreement. Furthermore, the new data interpretation consumes an excessive amount of time and resources. Hence, an automatic seizure detection and prediction system can improve the quality of patient care in terms of shortening the diagnosis period, reducing manual errors, and automatically detecting debilitating events. Moreover, for patient treatment, it is important to alert the patients of epilepsy seizures prior to seizure occurrence. Various distinguished studies presented good solutions for two-class seizure detection problems with binary classification scenarios. To deal with these challenges, this paper puts forward effective approaches for EEG signal classification for normal, pre-ictal, and ictal activities. Three models are presented for the classification task. Two of them are patient-specific, while the third one is patient non-specific, which makes it better for the general classification tasks. The two-class classification is implemented between normal and pre-ictal activities for seizure prediction and between normal and ictal activities for seizure detection. A more generalized three-class classification framework is considered to identify all EEG signal activities. The first model depends on a Convolutional Neural Network (CNN) with residual blocks. It contains thirteen layers with four residual learning blocks. It works on spectrograms of EEG signal segments. The second model depends on a CNN with three layers. It also works on spectrograms. On the other hand, the third model depends on Phase Space Reconstruction (PSR) to eliminate the limitations of the spectrograms used in the first models. A five-layer CNN is used with this strategy. The advantage of the PSR is the direct projection from the time domain, which keeps the main trend of different signal activities. The third model deals with all signal activities, and it was tested for all patients of the CHB-MIT dataset. It has a superior performance compared to the first models and the state-of-the-art models.


Assuntos
Aprendizado Profundo , Epilepsia , Eletroencefalografia , Epilepsia/diagnóstico , Humanos , Redes Neurais de Computação , Convulsões/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA