Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
Heart Rhythm ; 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38432425

RESUMO

BACKGROUND: A rotational activation pattern (RAP) around the localized line of a conduction block often correlates with sites specific to the critical zones of ventricular tachycardia (VT). The wavefront direction during substrate mapping affects manifestation of the RAP and line of block. OBJECTIVE: The purpose of this study was to investigate the most optimal cardiac rhythm for identifying RAP and line of block in substrate mapping. METHODS: We retrospectively evaluated 71 maps (median 3205 points/map) in 46 patients (65 ± 15 years; 33% with ischemic cardiomyopathy) who underwent high-density substrate mapping and ablation of scar-related VT. Appearance of a RAP during sinus, right ventricular (RV)-paced, left ventricular (LV)-paced, and biventricular-paced rhythms was investigated. RESULTS: RAP was identified in 24 of 71 maps (34%) in the region where wavefronts from a single direction reached but not in the region where wavefronts from multiple directions centripetally collided. The probability of identifying the RAP depended on scar location; that is, anteroseptal and inferoseptal, inferior and apical, and basal lateral RAPs were likely to be identified during sinus/atrial, RV-paced, and LV-paced rhythms, respectively. In 13 patients, the RAP was not evident in the baseline map but became apparent during remapping in the other rhythm, in which the wavefront reached the site earlier within the entire activation time. CONCLUSION: The optimal rhythm for substrate mapping depends on the spatial distribution of the area of interest. A paced rhythm with pacing sites near the scar may facilitate the identification of critical VT zones.

2.
ESC Heart Fail ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38467476

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) is an established treatment for drug-refractory heart failure (HF) in patients with left bundle branch block (LBBB). Acute haemodynamic improvement after CRT implantation may enable the intensification of HF medication soon thereafter. Immediate pharmacotherapy intensification (IPI) after CRT implantation achieves a synergetic effect, possibly leading to a better prognosis. This study aimed to explore the incidence, characteristics, and impact of IPI on real-world outcomes among CRT recipients with a history of hospitalization for acute HF. METHODS AND RESULTS: This multicentre retrospective study enrolled CRT recipients with LBBB morphology, a QRS width ≥120 ms, a left ventricular ejection fraction ≤35%, and New York Heart Association II-IV HF symptoms. All patients had previous HF hospitalizations within the previous year and received guideline-directed medical therapy before CRT implantation. Patient baseline characteristics, including HF medication, were collected. IPI was defined as the intensification of beta-blockers, angiotensin-converting enzyme inhibitors, angiotensin receptor blockers, and mineralocorticoid receptor antagonists within 30 days of CRT implantation. The primary endpoint was all-cause death or first hospitalization for HF; the secondary endpoint was all-cause death. We enrolled 194 patients (75% male; mean age, 65 ± 13 years; 78% with non-ischaemic cardiomyopathy). One hundred five (54%) patients received IPI. Patients who received IPI exhibited a significantly shorter QRS duration (159 ± 26 vs. 171 ± 32 ms; P = 0.004), higher estimated glomerular filtration rate (55.2 ± 20.0 vs. 47.8 ± 24.7 mL/min/1.73 m2 ; P = 0.022), and more dilated cardiomyopathy. During a median follow-up period of 29 months, 70 (36%) patients reached the primary endpoint and 42 (22%) patients died. Patients with IPI showed significantly better outcomes for the primary and secondary endpoints than patients without IPI. The volumetric responder ratio at 6 months after implantation was not significantly different between patients with and without IPI; however, patients who received IPI had reduced mortality even at 6 months after implantation. In the multivariate analysis, IPI was an independent predictor of the primary endpoint (hazard ratio, 0.51; 95% confidence interval, 0.27-0.97; P = 0.043). CONCLUSIONS: Immediate intensification of HF medication was achieved in 54% of CRT recipients and was significantly higher in patients without excessive QRS prolongation, preserved renal function, and dilated cardiomyopathy than others. In patients with LBBB morphology and QRS ≥ 120 ms, IPI was associated with a significantly better prognosis and fewer HF hospitalizations after CRT implantation than others.

3.
Int Heart J ; 64(4): 614-622, 2023 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-37460316

RESUMO

Radiofrequency catheter ablation (RFCA) to treat ventricular arrhythmias (VAs) originating below the His bundle (HB) region of the right ventricular (RV) septum could impair the atrioventricular node conduction. This study aimed to clarify the parameters of the 12-lead electrocardiography that predict successful RFCA of VAs originating from this region. This study included 20 consecutive patients (13 men; mean age, 68 ± 7 years) with monomorphic VAs in whom the earliest ventricular activation during the VA was below the HB region of the RV septum. According to the ablation results, the patients were divided into two groups: successful ablation (S-group; n = 10) and failed ablation groups (F-group; n = 10). The electrocardiographic parameters during the VAs and RFCA results were assessed. The R wave amplitudes in leads aVL (P = 0.001) and I (P = 0.010) in the S-group were both smaller than those in the F-group. In addition, the S-group had smaller negative deflection amplitudes in leads III (P = 0.002) and aVF (P = 0.003) than the F-group. According to the receiver operating characteristic curve analysis, the most useful electrocardiographic parameter for predicting successful ablation was the R wave amplitude in lead aVL (area under the curve, 0.895; P < 0.001); a cutoff value of < 1.3 mV predicted a successful RFCA with the highest accuracy (sensitivity, 90%; specificity, 80%; positive predictive value, 82%; negative predictive value, 89%). The R wave amplitude in lead aVL was the most useful parameter for predicting a successful RFCA to treat VAs originating below the HB region of the RV septum.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Ventrículos do Coração , Fascículo Atrioventricular/cirurgia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Eletrocardiografia/métodos , Ablação por Cateter/métodos , Resultado do Tratamento
5.
PLoS One ; 18(2): e0281818, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36827294

RESUMO

BACKGROUND: Atrial fibrillation (AF) is the most common arrhythmia and often recurs despite catheter ablation. The recurrence of AF is often underdiagnosed by standard 24-hour electrocardiogram (ECG) because of its transient and silent nature. A garment-style ECG with a highly conductive textile electrode made of poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate)(PEDOTPSS) and nanofiber (Garment ECG) has been developed that can provide longer-term continuous monitoring. This study investigated whether 2-week Garment ECG can reveal instances of AF recurrence in patients who are diagnosed as remaining in sinus rhythm by 24-hour Holter ECG. METHODS: The open-label randomized crossover study enrolled 67 patients (63.1±10.6 years old, 53 men) who had undergone initial AF ablation. Three months after ablation, patients were randomly assigned to group 1 (n = 35), 2-week Garment ECG followed by 24-hour Holter ECG, or group 2 (n = 32), 24-hour Holter ECG followed by 2-week Garment ECG. The detection of AF recurrence was compared between the two devices. RESULTS: The Garment ECG showed AF recurrence in 12 patients (18%) compared to 4 patients for the Holter ECG (6%, p = 0.008). The ECG acquisition rate was higher for Holter ECG than for Garment ECG (100.0% [interquartile range 100.0-100.0%] versus 82.4% [71.1-91.0%], p<0.001), but the Garment ECG provided longer total analysis time (11.0 days [9.0-12.2 days] for Garment; 1.0 day [1.0-1.0 day] for Holter, p<0.001). CONCLUSIONS: Despite the lower ECG acquisition rate, the 2-week Garment ECG revealed instances of AF recurrence after ablation in patients who were underdiagnosed by 24-hour Holter ECG. TRIAL REGISTRATION: Clinical Trial Registration: URL: https://jrct.niph.go.jp/en-latest-detail/jRCTs032180018 Unique Identifier: jRCTs032180018.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Eletrocardiografia Ambulatorial , Estudos Cross-Over , Eletrocardiografia , Vestuário , Recidiva , Resultado do Tratamento
6.
F1000Res ; 11: 97, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35860478

RESUMO

Background: Holter electrocardiogram (ECG) is the gold standard for ambulatory monitoring of atrial fibrillation (AF) but it is insufficient because of its limited recording time. Although several consumer ECG devices provide longer recording time, they generally do not undergo the regulatory process for medical use. Furthermore, current medical-grade devices for longer ECG monitoring are not continuous or too invasive for AF monitoring. A wearable ECG with a medical-grade dry textile electrode is a promising technology to remedy this limitation. This pilot study aimed to simultaneously compare the wearable and Holter ECGs for ambulatory monitoring in a clinical setting. Methods: This prospective observational study enrolled 18 patients who underwent AF ablation. One day after AF ablation, ambulatory ECG was obtained for three hours simultaneously using both the wearable and Holter ECG devices. Automatic ECG interpretations between devices were compared with correlation and agreement analyses. Results: Simultaneous ECG monitoring demonstrated a comparable analysis time and total heart beats between the two devices. Almost complete correlation and agreement were also demonstrated in all clinically relevant testing aspects except in R-wave amplitude (r = 0.743, p < .001). AF was detected in three patients. AF duration was the same in both ECG devices in two patients with continuous AF. In the remaining patient with intermittent AF, AF duration was shortened by 0.6% with the wearable ECG as compared to that with the Holter ECG. Conclusions: Simultaneous ECG comparison revealed a high consistency between the wearable and Holter ECG devices. The results of this study warrant further clinical studies for long-term monitoring of ambulatory ECG after AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Eletrodos , Humanos , Projetos Piloto , Têxteis
7.
Pacing Clin Electrophysiol ; 45(6): 773-785, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35430753

RESUMO

INTRODUCTION: Catheter ablation is a therapeutic option to suppress ventricular tachycardia (VT) in the setting of dilated-phase hypertrophic cardiomyopathy (DHCM). However, the characteristics of the arrhythmogenic substrate and the ablation outcome are not fully illustrated. METHOD: A total of 23 ablation procedures for drug-refractory sustained monomorphic VTs in 13 DHCM patients (60 ± 11 years, one female, the left ventricular [LV] ejection fraction 39% ± 9%, the LV mass index 156 ± 39 g/m2 ) were performed. The distribution of VT substrate as endocardial or epicardial/intramural was based on detailed mapping and ablation response during VT. RESULT: Two patients underwent ablation of sustained monomorphic VT that was not scar-mediated tachycardia. Of the remaining 11 patients, eight (73%) patients had VT substrate in the basal regions, most frequently at the epicardial and/or intramural basal antero-septum. None of the patients had VT substrate located at the LV inferolateral region. Ablation at the right ventricular septum and the aortic cusps was done in four and five patients, respectively. Other approaches including bipolar and chemical ablations, were done in three and two patients, respectively. Six (55%) out of 11 patients (two patients lost follow-up) had VT recurrence. All the six patients had basal substrate. However, anti-tachycardia pacing was sufficient for VT termination except in one patient. CONCLUSION: Catheter ablation of VT in patients with DHCM is challenging because of the predominant basal anteroseptal epicardial/intramural location of arrhythmogenic substrate. An ablation approach from multiple sites and/or adjunctive interventional techniques are often required.


Assuntos
Cardiomiopatia Dilatada , Cardiomiopatia Hipertrófica , Ablação por Cateter , Taquicardia Ventricular , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/cirurgia , Ablação por Cateter/métodos , Endocárdio , Feminino , Humanos , Resultado do Tratamento
9.
Circ Arrhythm Electrophysiol ; 15(1): e010308, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34937390

RESUMO

BACKGROUND: Recent advancements in a 3-dimensional mapping system allow for the assessment of detailed conduction properties during sinus rhythm and thus the establishment of a strategy targeting functionally abnormal regions in scar-related ventricular tachycardia (VT). We hypothesized that a rotational activation pattern (RAP) observed in maps during baseline rhythm was associated with the critical location of VT. METHODS: We retrospectively examined the pattern of wavefront propagation during sinus rhythm in patients with scar-related VT. The prevalence and features of the RAP on critical VT circuits were analyzed. RAP was defined as >90° of inward curvature directly above or at the edge of the slow conductive areas. RESULTS: Forty-five VTs in 37 patients (66±15 years old, 89% male, 27% ischemic heart disease) were evaluated. High-density substrate mapping during sinus rhythm (median, 2524 points) was performed using the CARTO3 system before VT induction. Critical sites for reentry were identified by direct termination by radiofrequency catheter ablation in 21 VTs or by pace mapping in 12 VTs. Among them, RAP was present in 70% of the 33 VTs. Four VTs had no RAP at the critical sites during sinus rhythm, but it became visible in the mappings with different wavefront directions. Six VTs, in which intramural or epicardial isthmus was suspected, were rendered noninducible by radiofrequency catheter ablation to the endocardial surface without RAP. RAP had a sensitivity and specificity of 70% and 89%, respectively, for predicting the elements in the critical zone for VT. CONCLUSIONS: The critical zone of VT appears to correspond to an area characterized by the RAP with slow conduction during sinus rhythm, which facilitates targeting areas specific for reentry. However, this may not be applicable to intramural VT substrates and might be affected by the direction of wavefront propagation to the scar during mapping. Graphic Abstract: A graphic abstract is available for this article.


Assuntos
Potenciais de Ação , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/cirurgia , Remodelação Ventricular , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Feminino , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Taquicardia Ventricular/patologia , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
10.
J Cardiol ; 79(3): 365-370, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34937673

RESUMO

BACKGROUND: Mechanical and electrical restoration by cardiac resynchronization therapy (CRT) with adaptive pacing algorithm (aCRT) in heart failure patients with a moderately wide (120-149 ms) QRS has not been fully evaluated. The purpose of this study was to investigate the therapeutic effect of aCRT compared with conventional biventricular CRT (BiV-CRT) regardless of QRS morphology. METHODS: Seventeen consecutive patients with a QRS ≥120 ms, regardless of morphology, underwent CRT device implantation with an aCRT pacing algorithm. Propensity score matched analysis was performed to evaluate the impact of aCRT on the improvement in mechanical and electrical parameters after CRT device implantation using historical controls (HC) from the clinical registry of BiV-CRT (START trial). RESULTS: Left ventricular (LV) volume significantly decreased after CRT in all patients in both the aCRT and HC groups. The difference in relative reduction of LV end-systolic volume (LVESV) was not significantly different between the 2 arms. QRS shortening after CRT was significantly greater in the aCRT group than in the BiV-CRT group, and the difference was prominent in patients with a moderately wide QRS (120-149 ms). In patients with a moderately wide QRS, the relative reduction in LVESV [39 (29-47)% vs. 2 (-6-20)%, p = 0.04] and proportion of LV volume responders (90% vs. 38%, p = 0.04) were significantly greater in the aCRT group than in the HC group. The proportion of volume responders was not significantly different in patients with a wide QRS (≥150 ms). CONCLUSIONS: The aCRT algorithm improved electrical and mechanical parameters in patients with a moderately wide QRS, regardless of QRS morphology.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca Sistólica , Insuficiência Cardíaca , Algoritmos , Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca Sistólica/terapia , Ventrículos do Coração , Humanos , Resultado do Tratamento
11.
J Cardiol ; 78(6): 517-523, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34334266

RESUMO

BACKGROUND: Left atrial (LA) global strain has been studied as an early marker of LA dysfunction, followed by LA dilatation. Recently, a novel dedicated software for LA 3-dimensional speckle tracking echocardiography (LA-3DSTE) has allowed us to assess anatomy-based six-segmental LA deformation. This study aimed to assess the accuracy of LA-3DSTE software in measuring LA volume and to reveal the characteristics of regional LA reservoir strain. METHODS: Fifty patients with paroxysmal atrial fibrillation who underwent computed tomography (CT) and 3D-STE were enrolled. The LA volumes obtained by 3D-STE and CT were compared, and regional LA strain was analyzed. Six LA segments (anterior, septal, inferior, lateral, roof, and posterior) were determined on the basis of LA anatomy. RESULTS: In 50 patients (mean age, 64 years; 62% male), the 3D-STE-derived LA volume index (LAVI) showed good correlation with the CT-derived index, (r = 0.78, p < 0.001) with an underestimate bias of 10.5 ± 11.0 ml/m2 (p < 0.001). The lateral LA strain was negatively correlated with LAVI and emptying fraction, while the anterior and septal strains were not. In the 1st quantile LA volume group, the segmental LA strain was heterogeneous, that is, the lateral and inferior strains were greater than the anterior strain. While in the 3rd quantile LA volume group, the lateral and inferior strains were decreased, and there was no regional difference. CONCLUSION: LA volume obtained by 3D-STE and CT showed a good correlation. LA segmental analysis by 3D-STE enables early identification of how LA dysfunction affects lateral and inferior LA strains, consistent with anatomical features.


Assuntos
Fibrilação Atrial , Ecocardiografia Tridimensional , Fibrilação Atrial/diagnóstico por imagem , Função do Átrio Esquerdo , Ecocardiografia , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
12.
CJC Open ; 3(6): 827-830, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34169262

RESUMO

Radiofrequency catheter ablation (RFCA) is the primary choice for treating patients with an accessory pathway and atrioventricular re-entrant tachycardia. However, using RFCA to treat a right-sided accessory pathway in a patient with Ebstein anomaly can be difficult owing to challenges in locating the electrophysiological atrioventricular groove. We report a case of atrioventricular re-entrant tachycardia in a patient with Ebstein anomaly and a right-sided accessory pathway that was successfully treated using RFCA and 3-dimensional (3D) high-density mapping. RFCA and 3D mapping may be useful in the management of such cases and may aid in improving prognoses of patients.


L'ablation par radiofréquence (ARF) est le premier choix de traitement chez les patients qui ont une voie accessoire et une tachycardie atrioventriculaire par réentrée. Toutefois, l'utilisation de l'ARF pour traiter une voie accessoire du côté droit d'un patient qui a une anomalie d'Ebstein peut être difficile en raison des défis de la loca-lisation du sillon atrioventriculaire à l'exploration électrophysiologique. Nous rapportons un cas de tachycardie atrioventriculaire par réentrée chez un patient qui a une anomalie d'Ebstein et une voie accessoire du côté droit, dont le traitement au moyen de l'ARF et de la cartographie tridimensionnelle (3D) haute définition a connu une réussite. L'ARF et la cartographie 3D peuvent être utiles dans la prise en charge de ces cas et aider à améliorer le pronostic des patients.

13.
JACC Clin Electrophysiol ; 7(7): 843-854, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33640356

RESUMO

OBJECTIVES: This study sought to demonstrate a new type of verapamil-sensitive fascicular ventricular tachycardia (VT) with a reverse circuit. BACKGROUND: Left posterior fascicular ventricular tachycardia (LPFVT) is the most common form of verapamil-sensitive fascicular VT. Reverse-type LPFVT has not been reported. METHODS: We searched for a reverse-type LPFVT among 242 patients with verapamil-sensitive VT from February 2006 to September 2019. RESULTS: Three patients had a reverse-type LPFVT (cycle lengths: 340, 360, and 340 ms). QRS configuration during VT was narrow (140, 150, and 140 ms) and exhibited rSr' morphology in V1 with an early precordial transition and inferior axis. Two of 3 patients had common-type LPFVT. During reverse-type LPFVT, the earliest ventricular activation was the left superior middle septum. Fragmented Purkinje potentials (P1) buried within the local ventricular electrogram were recorded with an activation sequence from the apex to the base and were linked to the subsequent left ventricular septal activation. After radiofrequency catheter ablation at P1 during LPFVT, the reverse-type LPFVT also became noninducible. In 1 patient with only the reverse-type LPFVT, radiofrequency catheter ablation at the earliest LV activation site suppressed VT. These findings suggest that this new type of verapamil-sensitive fascicular VT shares a re-entrant circuit with a reverse direction of common LPFVT with an intramural exit site at the superior middle septum. CONCLUSIONS: Reverse-type LPFVT can occur. If common LPFVT exists, diastolic P1 during LPFVT can be a common target of ablation. If only reverse-LPFVT is inducible, the earliest ventricular activation site can be a target.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Eletrocardiografia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
14.
J Cardiol ; 77(6): 652-659, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33509678

RESUMO

BACKGROUND: RE-CIRCUIT (NCT02348723) and ABRIDGE-J (UMIN000013129) are recently published randomized clinical trials showing that anticoagulation therapy with dabigatran during the periprocedural period of catheter ablation (CA) for atrial fibrillation (AF) was associated with fewer complications. However, the dabigatran administration protocols were different (uninterrupted in RE-CIRCUIT and minimally interrupted in ABRIDGE-J). The aim of this present study was to clarify the optimal interruption time of dabigatran Oral administration to Ablation (O-A time). METHODS: We conducted an integrated analysis of the 2 prospective trials. The endpoint of the study was the incidence of major bleeding events during and up to 8 weeks after CA across participants with different O-A times. RESULTS: The 535 patients in the dabigatran groups of the 2 trials were divided into 3 groups based on their O-A times (<8 h, n = 258; 8-24 h, n = 191; >24 h, n = 86). Major bleeding events occurred in 5 patients (1.9%) in the <8 h group, and 3 (3.5%) in the >24 h group; however, no major bleeding events occurred in the 8-24 h group (3 group-comparison, p = 0.026). No thromboembolic complication was observed in any of the 3 O-A time groups. CONCLUSION: In patients undergoing CA for AF using dabigatran as a periprocedural anticoagulant, an O-A time of 8-24 h was associated with no bleeding complications. These data suggest that an O-A time of 8-24 h may be an appropriate option, especially in a low thromboembolic-risk patient.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Administração Oral , Anticoagulantes/uso terapêutico , Fibrilação Atrial/cirurgia , Dabigatrana/uso terapêutico , Humanos , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
15.
J Interv Card Electrophysiol ; 62(1): 21-30, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32939701

RESUMO

PURPOSE: Antral pulmonary vein isolation (PVI) using a radiofrequency hot balloon catheter (RHB) is a feasible therapeutic option for treating atrial fibrillation (AF). Lesion durability after antral RHB-PVI remains unknown. This study aimed to evaluate lesion durability and the associations between procedural characteristics after antral RHB-PVI. METHODS: A total of 200 patients received antral RHB-PVI using the single-shot technique between April 2016 and March 2018. Antral RHB-PVI was performed following a pre-specified protocol and RHB energy application was performed for a maximum of two times for each PV. Consecutive patients who underwent repeated procedures for recurrence of any type of atrial tachyarrhythmia were enrolled. RESULTS: Twenty-six (13%) patients underwent repeated ablation and 20 patient documented AF recurrence (AF group) and 6 patients documented non-AF recurrence (non-AF group). Repeated ablation was performed at a median (25th, 75th percentiles) of 378 days (217, 487) after the initial procedure and durable PVI was observed in 86 (83.5%) PVs. Durability reached 89.7% when PVI was achieved only using an RHB. In the AF group (79 PVs), durable PVI was observed in 62 (78.5%) PVs, whereas all 24 PVs were still isolated in the non-AF group. The majority of reconnection sites were around the superior PVs. CONCLUSIONS: Antral RHB-PVI shows high lesion durability, especially with both inferior PVs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Catéteres , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
16.
Int Heart J ; 61(5): 896-904, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32999195

RESUMO

Identifying the optimal atrioventricular (AV) or interventricular (VV) delay is beneficial for patients using cardiac resynchronization therapy (CRT) devices. Ultrasonic echocardiography (UCG) has been the most commonly used method; however, it requires high technical knowledge. Impedance cardiography (ICG) can calculate stroke volume by measuring changes in transthoracic electric impedance. This study sought to assess the clinical utility of ICG in comparison with that of UCG for the optimization of CRT devices.Patients who underwent CRT device implantation were retrospectively analyzed. One week after implantation, optimization of AV delay (AVD) was performed in every patient with ICG (AVD-ICG) and UCG (AVD-UCG). VV delay (VVD) was then determined according to the optimal AVD using these two methods.Forty-two patients were enrolled. Average AVD-ICG was significantly shorter than AVD-UCG (128 ± 49 versus 146 ± 41 milliseconds, P = 0.018). Five patients (12%) had the same optimized AVD with two methods, and the difference between AVD-ICG and AVD-UCG was ≤ 20 milliseconds in 19 patients (45%). In the multivariate analysis, the presence of postoperative mitral regurgitation (MR) was an independent predictor of AVD-ICG/AVD-UCG mismatch, defined as a difference over 20 milliseconds (odds ratio = 10.71; 95% confidence interval = 1.72 to 66.72; P = 0.018). The results of optimized VVD were similar using both methods.ICG might be a promising tool for the rapid optimization of CRT devices. However, in patients with moderate-to-severe MR, ICG may not be able to optimize AVD.


Assuntos
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Cardiografia de Impedância , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico por imagem , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral , Complicações Pós-Operatórias , Estudos Retrospectivos
17.
Heart Rhythm ; 17(9): 1500-1507, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32353585

RESUMO

BACKGROUND: Successful bipolar radiofrequency catheter ablation (RFCA) of refractory ventricular arrhythmias (VAs) has been reported. However, the efficacy, safety, and long-term outcomes of bipolar RFCA of VAs are not fully determined. OBJECTIVE: The purpose of this study was to evaluate the effectiveness and safety of bipolar RFCA in treating refractory VAs during long-term follow-up. METHODS: Eighteen patients who underwent bipolar RFCA for ventricular tachycardia (VT) at 7 institutions were retrospectively investigated. Underlying heart diseases included remote myocardial infarction (n = 3 [17%]) and nonischemic cardiomyopathy (n = 15 [83%]). Although unipolar RFCA was performed in all patients, either it failed to suppress VT or VT recurred. The interventricular septum, left ventricular free wall, and left ventricular summit were targeted for bipolar RFCA. RESULTS: Acute success (VT termination and/or noninducibility) was achieved with bipolar RFCA in 16 patients (89%). Complications during the procedure included complete atrioventricular block (n = 2) and coronary artery stenosis (n = 1). One patient underwent chemical ablation after bipolar RFCA failure. At 12-month follow-up, VT reoccurred in 8 patients (44%). However, in patients with recurrence, VT burden had decreased: only 4 patients underwent re-RFCA, and only 1 of the 4 required chemical ablation. In the remaining 4 patients, re-RFCA was not required, as VT was controlled by medication or an implantable cardioverter-defibrillator. CONCLUSION: Bipolar RFCA is useful for acute suppression of refractory VT. Although VT recurrence rates during long-term follow-up were relatively high, we observed a significant reduction in VT burden.


Assuntos
Ablação por Cateter/métodos , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Taquicardia Ventricular/cirurgia , Doença Aguda , Idoso , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 31(7): 1709-1718, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32391641

RESUMO

INTRODUCTION: Catheter ablation (CA) for long-standing persistent atrial fibrillation (LS-AF) remains challenging. We aimed to explore whether sinus rhythm (SR) restoration and left atrium (LA) function after pretreatment with antiarrhythmic drugs (AAD's) and electrical cardioversion (ECV) predict procedural outcomes. METHODS AND RESULTS: We included 100 consecutive patients with LS-AF who were treated with AAD/ECV for at least 3 months before CA. The echocardiographic LA strain during reservoir phase (LASr) was assessed after pretreatment as a marker of LA fibrosis. The recurrence was recorded for ≥1 year after the last procedure. During a 34 ± 16-month follow-up period, the single and multiple procedures and pharmaceutically assisted success rates were 40% and 71%, respectively. Patients with preprocedural SR restoration and higher LASr showed a significantly higher recurrence-free probability after the last CA (logrank P = .001 and P < .001, respectively). Failure of preprocedural SR restoration and LASr ≤8.6% were independently associated with recurrence after the last CA (hazard ratio [HR]: 3.13, 95% confidence interval [CI]: 1.42-6.91, P = .005; HR: 3.89, 95% CI: 1.65-9.17, P = .002, respectively). These parameters added incrementally to the predictive value of AF duration and LA dilatation (P = .03 and P = .002, respectively) and improved the recurrence-risk stratification (net reclassification improvement = 0.39; 95% CI = 0.13-0.65; P = .003). CONCLUSION: In patients with LS-AF, the inability to restore SR and lower LASr after AAD/ECV treatment independently and incrementally predicts the recurrence after CA. These findings might be useful for determining LS-AF ablation candidates.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter/efeitos adversos , Átrios do Coração , Humanos , Recidiva , Resultado do Tratamento
19.
Pacing Clin Electrophysiol ; 43(5): 437-443, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32115739

RESUMO

BACKGROUND: Paucity of a premature ventricular complex (PVC) during ablation procedures may occur and be associated with a lower success rate. Isoproterenol (ISP) injections are commonly used to induce PVC; however, the induced tachycardia sometimes prevents the appearance of PVC. Epinephrine (EPI) administration may be an alternative strategy to induce PVC due to its smaller effect on heart rate (HR). This study sought to examine the electrophysiological impact of EPI injection, with a stepwise induction protocol, for infrequent intraprocedural PVC. METHODS: We studied 78 consecutive patients who underwent catheter ablation of idiopathic frequent PVC. If no PVC was observed at the beginning of the procedure, ISP (10 µg) was injected. If clinical PVC was not induced by ISP administration, EPI (10 µg) was injected. RESULTS: Of 18 patients without PVC at baseline, ISP injection induced PVC in five patients. Of the remaining 13 patients, EPI injection successfully induced PVC in seven patients (53%). The maximum HR and increments of HR after EPI injection were significantly lower than those after ISP injection (99 ± 15 vs 137 ± 15 bpm, P = .001; 22 ± 10 vs 53 ± 12 bpm, P < .001, respectively). There were no complications related to the induction protocol. CONCLUSION: EPI injection following ISP injection is an effective and safe stepwise approach for the induction of infrequent PVC in the electrophysiology laboratory. It is hypothesized that α- and ß-adrenergic receptor stimulation by EPI injections, with reduced HR acceleration compared to that with ISP injections, may result in the successful induction of PVC.


Assuntos
Epinefrina/administração & dosagem , Isoproterenol/administração & dosagem , Complexos Ventriculares Prematuros/induzido quimicamente , Ablação por Cateter , Angiografia Coronária , Ecocardiografia , Eletrocardiografia , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA