Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Front Neurosci ; 18: 1396966, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38835836

RESUMO

Understanding the retinogeniculate pathway in vitro can offer insights into its development and potential for future therapeutic applications. This study presents a Polydimethylsiloxane-based two-chamber system with axon guidance channels, designed to replicate unidirectional retinogeniculate signal transmission in vitro. Using embryonic rat retinas, we developed a model where retinal spheroids innervate thalamic targets through up to 6 mm long microfluidic channels. Using a combination of electrical stimulation and functional calcium imaging we assessed how channel length and electrical stimulation frequency affects thalamic target response. In the presented model we integrated up to 20 identical functional retinothalamic neural networks aligned on a single transparent microelectrode array, enhancing the robustness and quality of recorded functional data. We found that network integrity depends on channel length, with 0.5-2 mm channels maintaining over 90% morphological and 50% functional integrity. A reduced network integrity was recorded in longer channels. The results indicate a notable reduction in forward spike propagation in channels longer than 4 mm. Additionally, spike conduction fidelity decreased with increasing channel length. Yet, stimulation-induced thalamic target activity remained unaffected by channel length. Finally, the study found that a sustained thalamic calcium response could be elicited with stimulation frequencies up to 31 Hz, with higher frequencies leading to transient responses. In conclusion, this study presents a high-throughput platform that demonstrates how channel length affects retina to brain network formation and signal transmission in vitro.

2.
Nat Methods ; 21(6): 1063-1073, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38802520

RESUMO

The dynamics of cellular membrane tension and its role in mechanosensing, which is the ability of cells to respond to physical stimuli, remain incompletely understood, mainly due to the lack of appropriate tools. Here, we report a force-controlled nanopipette-based method that combines fluidic force microscopy with fluorescence imaging for precise manipulation of the cellular membrane tension while monitoring the impact on single-cell mechanosensitivity. The force-controlled nanopipette enables control of the indentation force imposed on the cell cortex as well as of the aspiration pressure applied to the plasma membrane. We show that this setup can be used to concurrently monitor the activation of Piezo1 mechanosensitive ion channels via calcium imaging. Moreover, the spatiotemporal behavior of the tension propagation is assessed with the fluorescent membrane tension probe Flipper-TR, and further dissected using molecular dynamics modeling. Finally, we demonstrate that aspiration and indentation act independently on the cellular mechanobiological machinery, that indentation induces a local pre-tension in the membrane, and that membrane tension stays confined by links to the cytoskeleton.


Assuntos
Membrana Celular , Canais Iônicos , Mecanotransdução Celular , Canais Iônicos/metabolismo , Membrana Celular/metabolismo , Mecanotransdução Celular/fisiologia , Humanos , Simulação de Dinâmica Molecular , Cálcio/metabolismo , Animais
3.
Lab Chip ; 23(23): 5047-5058, 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-37916299

RESUMO

Precise control of pH values at electrode interfaces enables the systematic investigation of pH-dependent processes by electrochemical means. In this work, we employed high-density complementary metal-oxide-semiconductor (CMOS) microelectrode arrays (MEAs) as miniaturized systems to induce and confine electrochemical reactions in areas corresponding to the pitch of single electrodes (17.5 µm). First, we present a strategy for generating localized pH patterns on the surface of the CMOS MEA with unprecedented spatial resolution. Leveraging the versatile routing capabilities of the switch matrix beneath the CMOS MEA, we created arbitrary combinations of anodic and cathodic electrodes and hence pH patterns. Moreover, we utilized the system to produce polymeric surface patterns by additive and subtractive methods. For additive patterning, we controlled the in situ formation of polydopamine at the microelectrode surface through oxidation of free dopamine above a threshold pH > 8.5. For subtractive patterning, we removed cell-adhesive poly-L-lysine from the electrode surface and backfilled the voids with antifouling polymers. Such polymers were chosen to provide a proof-of-concept application of controlling neuronal growth via electrochemically-induced patterns on the CMOS MEA surface. Importantly, our platform is compatible with commercially available high-density MEAs and requires no custom equipment, rendering the findings generalizable and accessible.

4.
Biosens Bioelectron ; 239: 115591, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37634421

RESUMO

Bottom-up neuroscience utilizes small, engineered biological neural networks to study neuronal activity in systems of reduced complexity. We present a platform that establishes up to six independent networks formed by primary rat neurons on planar complementary metal-oxide-semiconductor (CMOS) microelectrode arrays (MEAs). We introduce an approach that allows repetitive stimulation and recording of network activity at any of the over 700 electrodes underlying a network. We demonstrate that the continuous application of a repetitive super-threshold stimulus yields a reproducible network answer within a 15 ms post-stimulus window. This response can be tracked with high spatiotemporal resolution across the whole extent of the network. Moreover, we show that the location of the stimulation plays a significant role in the networks' early response to the stimulus. By applying a stimulation pattern to all network-underlying electrodes in sequence, the sensitivity of the whole network to the stimulus can be visualized. We demonstrate that microchannels reduce the voltage stimulation threshold and induce the strongest network response. By varying the stimulation amplitude and frequency we reveal discrete network transition points. Finally, we introduce vector fields to follow stimulation-induced spike propagation pathways within the network. Overall we show that our defined neural networks on CMOS MEAs enable us to elicit highly reproducible activity patterns that can be precisely modulated by stimulation amplitude, stimulation frequency and the site of stimulation.


Assuntos
Técnicas Biossensoriais , Animais , Ratos , Microeletrodos , Redes Neurais de Computação , Neurônios , Óxidos
5.
Front Neurosci ; 17: 1103437, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37250404

RESUMO

Novel in vitro platforms based on human neurons are needed to improve early drug testing and address the stalling drug discovery in neurological disorders. Topologically controlled circuits of human induced pluripotent stem cell (iPSC)-derived neurons have the potential to become such a testing system. In this work, we build in vitro co-cultured circuits of human iPSC-derived neurons and rat primary glial cells using microfabricated polydimethylsiloxane (PDMS) structures on microelectrode arrays (MEAs). Our PDMS microstructures are designed in the shape of a stomach, which guides axons in one direction and thereby facilitates the unidirectional flow of information. Such circuits are created by seeding either dissociated cells or pre-aggregated spheroids at different neuron-to-glia ratios. Furthermore, an antifouling coating is developed to prevent axonal overgrowth in undesired locations of the microstructure. We assess the electrophysiological properties of different types of circuits over more than 50 days, including their stimulation-induced neural activity. Finally, we demonstrate the inhibitory effect of magnesium chloride on the electrical activity of our iPSC circuits as a proof-of-concept for screening of neuroactive compounds.

6.
Lab Chip ; 22(7): 1386-1403, 2022 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-35253810

RESUMO

Bottom-up neuroscience, which consists of building and studying controlled networks of neurons in vitro, is a promising method to investigate information processing at the neuronal level. However, in vitro studies tend to use cells of animal origin rather than human neurons, leading to conclusions that might not be generalizable to humans and limiting the possibilities for relevant studies on neurological disorders. Here we present a method to build arrays of topologically controlled circuits of human induced pluripotent stem cell (iPSC)-derived neurons. The circuits consist of 4 to 50 neurons with well-defined connections, confined by microfabricated polydimethylsiloxane (PDMS) membranes. Such circuits were characterized using optical imaging and microelectrode arrays (MEAs), suggesting the formation of functional connections between the neurons of a circuit. Electrophysiology recordings were performed on circuits of human iPSC-derived neurons for at least 4.5 months. We believe that the capacity to build small and controlled circuits of human iPSC-derived neurons holds great promise to better understand the fundamental principles of information processing and storing in the brain.


Assuntos
Células-Tronco Pluripotentes Induzidas , Animais , Fenômenos Eletrofisiológicos , Eletrofisiologia , Humanos , Células-Tronco Pluripotentes Induzidas/fisiologia , Microeletrodos , Neurônios/fisiologia
7.
Front Neurosci ; 16: 829884, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35264928

RESUMO

In bottom-up neuroscience, questions on neural information processing are addressed by engineering small but reproducible biological neural networks of defined network topology in vitro. The network topology can be controlled by culturing neurons within polydimethylsiloxane (PDMS) microstructures that are combined with microelectrode arrays (MEAs) for electric access to the network. However, currently used glass MEAs are limited to 256 electrodes and pose a limitation to the spatial resolution as well as the design of more complex microstructures. The use of high density complementary metal-oxide-semiconductor (CMOS) MEAs greatly increases the spatial resolution, enabling sub-cellular readout and stimulation of neurons in defined neural networks. Unfortunately, the non-planar surface of CMOS MEAs complicates the attachment of PDMS microstructures. To overcome the problem of axons escaping the microstructures through the ridges of the CMOS MEA, we stamp-transferred a thin film of hexane-diluted PDMS onto the array such that the PDMS filled the ridges at the contact surface of the microstructures without clogging the axon guidance channels. This method resulted in 23 % of structurally fully connected but sealed networks on the CMOS MEA of which about 45 % showed spiking activity in all channels. Moreover, we provide an impedance-based method to visualize the exact location of the microstructures on the MEA and show that our method can confine axonal growth within the PDMS microstructures. Finally, the high spatial resolution of the CMOS MEA enabled us to show that action potentials follow the unidirectional topology of our circular multi-node microstructure.

8.
Biosens Bioelectron ; 201: 113896, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35032845

RESUMO

We present a stimulate and record paradigm to examine the behavior of multiple neuronal networks with controlled topology in vitro. Our approach enabled us to electrically induce and record neuronal activity from 60 independent networks in parallel over multiple weeks. We investigated the network performance of neuronal networks of primary hippocampal neurons until 29 days in vitro. We introduced a systematic stimulate and record protocol during which well-defined 4-node neural networks were stimulated electrically 4 times per second (4Hz) and their response was recorded over many days. We found that the network response pattern to a stimulus remained fairly stable for at least 12 h. Moreover, continuous stimulation over multiple weeks did not cause a significant change in the stimulation-induced mean spiking frequency of a circuit. We investigated the effect of stimulation amplitude and stimulation timing on the detailed network response. Finally, we could show that our setup can apply complex stimulation protocols with 125 different stimulation patterns. We used these patterns to perform basic addition tasks with the network, revealing the highly non-linear nature of biological networks' responses to complex stimuli.


Assuntos
Técnicas Biossensoriais , Redes Neurais de Computação , Neurônios
9.
Front Mol Neurosci ; 14: 790466, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34955746

RESUMO

The mammalian retina extracts a multitude of diverse features from the visual scene such as color, contrast, and direction of motion. These features are transmitted separately to the brain by more than 40 different retinal ganglion cell (RGC) subtypes. However, so far only a few genetic markers exist to fully characterize the different RGC subtypes. Here, we present a novel genetic Flrt3-CreERT2 knock-in mouse that labels a small subpopulation of RGCs. Using single-cell injection of fluorescent dyes in Flrt3 positive RGCs, we distinguished four morphological RGC subtypes. Anterograde tracings using a fluorescent Cre-dependent Adeno-associated virus (AAV) revealed that a subgroup of Flrt3 positive RGCs specifically project to the medial terminal nucleus (MTN), which is part of the accessory optic system (AOS) and is essential in driving reflex eye movements for retinal image stabilization. Functional characterization using ex vivo patch-clamp recordings showed that the MTN-projecting Flrt3 RGCs preferentially respond to downward motion in an ON-fashion. These neurons distribute in a regular pattern and most of them are bistratified at the level of the ON and OFF bands of cholinergic starburst amacrine cells where they express the known ON-OFF direction-selective RGC marker CART. Together, our results indicate that MTN-projecting Flrt3 RGCs represent a new functionally homogeneous AOS projecting direction-selective RGC subpopulation.

10.
Proc Natl Acad Sci U S A ; 118(40)2021 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-34599101

RESUMO

T cells sense and respond to their local environment at the nanoscale by forming small actin-rich protrusions, called microvilli, which play critical roles in signaling and antigen recognition, particularly at the interface with the antigen presenting cells. However, the mechanism by which microvilli contribute to cell signaling and activation is largely unknown. Here, we present a tunable engineered system that promotes microvilli formation and T cell signaling via physical stimuli. We discovered that nanoporous surfaces favored microvilli formation and markedly altered gene expression in T cells and promoted their activation. Mechanistically, confinement of microvilli inside of nanopores leads to size-dependent sorting of membrane-anchored proteins, specifically segregating CD45 phosphatases and T cell receptors (TCR) from the tip of the protrusions when microvilli are confined in 200-nm pores but not in 400-nm pores. Consequently, formation of TCR nanoclustered hotspots within 200-nm pores allows sustained and augmented signaling that prompts T cell activation even in the absence of TCR agonists. The synergistic combination of mechanical and biochemical signals on porous surfaces presents a straightforward strategy to investigate the role of microvilli in T cell signaling as well as to boost T cell activation and expansion for application in the growing field of adoptive immunotherapy.


Assuntos
Expressão Gênica/imunologia , Ativação Linfocitária/imunologia , Microvilosidades/imunologia , Linfócitos T/imunologia , Actinas/imunologia , Células Apresentadoras de Antígenos/imunologia , Células Cultivadas , Humanos , Receptores de Antígenos de Linfócitos T/imunologia , Transdução de Sinais/imunologia
11.
Colloids Surf B Biointerfaces ; 187: 110650, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31787457

RESUMO

DNA functionalized gold nanoparticles (DNA-AuNPs) have shown great potential for biosensing as they combine the excellent optical properties of gold nanoparticles and the molecular recognition function of DNA. Since the DNA density determines the assay performance and the stability of the conjugate, a precise control of the surface density of DNA-AuNP is crucial for an optimized biosensor. Here we report a simple assay for quantifying multiple unlabeled DNAs on AuNPs. The assay relies on potassium cyanide (KCN) to first dissolve the AuNPs, which then releases surface bound DNA for quantification through a double-stranded DNA dye. Using this analytical quantification method, we investigated several strategies to control the surface density of DNA-AuNPs. Besides the precise control of DNA density, the stability of DNA-AuNPs after conjugation is also important in developing a biosensor with optimal performance. Without proper storing conditions, DNA-AuNPs are unstable and aggregate over time. To overcome this problem, we developed a long-term storage solution to ensure the stability and quality of DNA-AuNPs after conjugation which would benefit any DNA-AuNP-based biosensor.


Assuntos
Técnicas Biossensoriais/métodos , DNA/análise , DNA/química , Ouro/química , Nanopartículas Metálicas/química , Coloides/química , Ditiotreitol/química , Congelamento , Ligantes , MicroRNAs/química , MicroRNAs/metabolismo , Cianeto de Potássio/química , Compostos de Sulfidrila/química
12.
Nat Nanotechnol ; 14(8): 791-798, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31308500

RESUMO

Proteins, nucleic acids and ions secreted from single cells are the key signalling factors that determine the interaction of cells with their environment and the neighbouring cells. It is possible to study individual ion channels by pipette clamping, but it is difficult to dynamically monitor the activity of ion channels and transporters across the cellular membrane. Here we show that a solid-state nanopore integrated in an atomic force microscope can be used for the stochastic sensing of secreted molecules and the activity of ion channels in arbitrary locations both inside and outside a cell. The translocation of biomolecules and ions through the nanopore is observed in real time in live cells. The versatile nature of this approach allows us to detect specific biomolecules under controlled mechanical confinement and to monitor the ion-channel activities of single cells. Moreover, the nanopore microscope was used to image the surface of the nuclear membrane via high-resolution scanning ion conductance measurements.


Assuntos
Canais Iônicos/análise , Íons/análise , Microscopia de Força Atômica/instrumentação , Nanoporos , Desenho de Equipamento , Células HEK293 , Humanos , Nanoporos/ultraestrutura , Análise de Célula Única/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA