Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
PLoS One ; 18(3): e0283241, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37000837

RESUMO

INTRODUCTION: High-dose chemotherapy followed by autologous stem cell transplant is the mainstay of treatment for multiple myeloma (MM). The purpose of this study was to evaluate the ability of MRI-derived indices to predict mobilized hematopoietic stem cell yield. MATERIALS AND METHODS: In this exploratory pilot work, we retrospectively analyzed 38 mobilization procedures for MM. Successful mobilization procedure was defined as a total yield of >4.0×106 CD34+ cells/kg. Univariate and multivariate analyses were performed to identify factors with a significant effect on successful mobilization from among clinical characteristics including number of prior lines of therapy, period from diagnosis to harvest, type of monoclonal protein (M protein); and radiological characteristics including total diffusion volume (tDV), median apparent diffusion coefficient (ADC) of tDV, and mean fat fraction of bone marrow calculated by MRI. RESULTS: Univariate analyses showed that relatively poor mobilization was significantly associated with M protein of Bence-Jones type and with median ADC of tDV (P = 0.02 and P = 0.004, respectively). Multivariate analyses using these two indices showed that median ADC of tDV was a significant predictive factor for adequate mobilization (P = 0.01), with an area under the curve of 0.784 (cutoff value, 1.18×10-3 mm2/s; sensitivity, 72.7%; specificity, 87.5%). CONCLUSION: The present data indicate that median ADC of tDV is a predictive factor for relatively poor mobilization of hematopoietic stem cells in MM patients undergoing autologous stem cell transplant.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Mieloma Múltiplo , Humanos , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/terapia , Estudos Retrospectivos , Células-Tronco Hematopoéticas/química , Antígenos CD34/análise , Imageamento por Ressonância Magnética , Mobilização de Células-Tronco Hematopoéticas/métodos , Fator Estimulador de Colônias de Granulócitos , Transplante Autólogo
2.
J Comput Assist Tomogr ; 45(3): 359-366, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33661153

RESUMO

OBJECTIVES: This study aimed to compare the accuracy of assessing the arterial hypervascularity of hepatocellular carcinoma (HCC) on dynamic computed tomography (CT) scans and gadoxetic acid (EOB)-enhanced magnetic resonance imaging (MRI) scans performed with radial sampling. METHODS: We studied the images of 40 patients with hypervascular HCC. A radiologist recorded the standard deviation of the attenuation (or the signal intensity [SI]) in subcutaneous fat tissue as the image noise (N) and calculated the contrast-to-noise ratio (CNR) as follows: (CNR) = (n-ROIT - n-ROIL)/N, where n-ROIT is the mean attenuation (or SI) of the tumor divided by the mean attenuation (or SI) of the aorta and n-ROIL is the mean attenuation (or SI) of the liver parenchyma divided by the mean attenuation (or SI) of the aorta. RESULTS: The CNR was significantly higher on EOB-enhanced MRI than on dynamic CT scans. CONCLUSIONS: For the assessment of HCC vascularity, EOB-enhanced MRI scans acquired with radial sampling were more accurate than dynamic CT images.


Assuntos
Angiografia/métodos , Carcinoma Hepatocelular/irrigação sanguínea , Gadolínio DTPA/administração & dosagem , Artéria Hepática/diagnóstico por imagem , Neoplasias Hepáticas/irrigação sanguínea , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
3.
Magn Reson Med Sci ; 19(1): 21-28, 2020 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-30880292

RESUMO

PURPOSE: Hepatobiliary-phase (HBP) MRI with gadoxetic acid facilitates the differentiation between lesions with and without functional hepatocytes. Thus, high-quality HBP images are required for the detection and evaluation of hepatic lesions. However, the long scan time may increase artifacts due to intestinal peristalsis, resulting in the loss of diagnostic information. Pseudo-random acquisition order disperses artifacts into the background. The aim of this study was to investigate the clinical applicability of pseudo-random trajectory scanning for the suppression of motion artifacts on T1-weighted images including HBP. METHODS: Our investigation included computer simulation, phantom experiments, and a clinical study. For computer simulation and phantom experiments a region of interest (ROI) was placed on the area with motion artifact and the standard deviation inside the ROI was measured as image noise. For clinical study we subjected 62 patients to gadoxetic acid-enhanced hepatobiliary-phase imaging with a circular- and a pseudo-random trajectory (c-HBP and p-HBP); two radiologists graded the motion artifacts, sharpness of the liver edge, visibility of intrahepatic vessels, and overall image quality using a five-point scale where 1 = unacceptable and 5 = excellent. Differences in the qualitative scores were determined using the two-sided Wilcoxon signed-rank test. RESULTS: The image noise was higher on the circular image compared with pseudo-random image (101.0 vs 60.9 on computer simulation image, 91.2 vs 67.7 on axial, 95.5 vs 86.9 on reformatted sagittal image for phantom experiments). For clinical study the score for motion artifacts was significantly higher with p-HBP than c-HBP imaging (left lobe: mean 3.4 vs 3.2, P < 0.01; right lobe: mean 3.6 vs 3.4, P < 0.01) as was the qualitative score for the overall image quality (mean 3.6 vs 3.3, P < 0.01). CONCLUSION: At gadoxetic acid-enhanced hepatobiliary-phase imaging, p-HBP scanning suppressed motion artifacts and yielded better image quality than c-HBP scanning.


Assuntos
Gadolínio DTPA/química , Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Artefatos , Simulação por Computador , Humanos , Imagens de Fantasmas
4.
Int J Urol ; 26(11): 1024-1032, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31379021

RESUMO

Upper urinary tract urothelial carcinoma is staged using the TNM classification of malignant tumors. Preoperative TNM is important for treatment planning. Computed tomography urography is now widely used for clinical survey of upper urinary tract carcinoma because of its diagnostic accuracy. Computed tomography urography is recommended as the first-line imaging procedure in several guidelines. Several reports stated that computed tomography urography is also useful for staging. However, no educational and practical reviews detailing the T staging of upper urinary tract urothelial carcinomas using imaging are available. We discuss the scanning protocol, T staging using computed tomography urography, limitations, magnetic resonance imaging, computed tomography comparison and pitfalls in imaging of upper urinary tract urothelial carcinoma. A recent study reported the high diagnostic accuracy of computed tomography urography with respect to T3 or higher stage tumors. To date, images that show a Tis-T2 stage have not been reported, but various studies are ongoing. Although magnetic resonance imaging has lower spatial resolution than computed tomography urography, magnetic resonance imaging can be carried out without radiation exposure or contrast agents. Magnetic resonance imaging also offers the unique ability of diffusion-weighted imaging without contrast agent use. Some researchers reported that diffusion-weighted imaging is useful not only for detecting lesions, but for predicting the T stage and tumor grade. We recommend the appropriate use of computed tomography and magnetic resonance while considering the limitations of each modality and the pitfalls in upper urinary tract urothelial carcinoma imaging.


Assuntos
Carcinoma de Células de Transição/diagnóstico por imagem , Urografia , Neoplasias Urológicas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Estadiamento de Neoplasias , Tomografia Computadorizada por Raios X
5.
Cardiovasc Intervent Radiol ; 42(9): 1352-1357, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31076840

RESUMO

PURPOSE: We evaluated the usefulness of the Amplatzer vascular plug (AVP) for preoperative embolization before distal pancreatectomy with en bloc celiac axis resection (DP-CAR). MATERIALS AND METHODS: Between April 2010 and September 2017, 19 patients with locally advanced pancreatic body cancer underwent preoperative embolization of the common hepatic and the left gastric artery (CHA, LGA) with AVP or coils. We compared the embolization success rate, embolization-related complications, the time required for preoperative embolization before DP-CAR and the procedure costs in patients whose CHA was AVP- (n = 7) or coil (n = 12) embolized. RESULTS: The success rate for preoperative AVP and coil embolization was 100% and 83.3%, respectively. The median procedure time was shorter in patients whose CHA was embolized with AVP than coils; the difference was not significant (p = 0.045). The total cost was significantly lower for AVP than coil embolization (p = 0.01). CONCLUSION: The AVP is useful for the preoperative embolization of the CHA before DP-CAR.


Assuntos
Artéria Celíaca/cirurgia , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Pancreatectomia , Neoplasias Pancreáticas/cirurgia , Cuidados Pré-Operatórios/métodos , Idoso , Feminino , Artéria Gástrica/diagnóstico por imagem , Artéria Gástrica/cirurgia , Artéria Hepática/diagnóstico por imagem , Artéria Hepática/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Pâncreas/cirurgia , Neoplasias Pancreáticas/diagnóstico por imagem , Radiografia , Dispositivo para Oclusão Septal
6.
Eur Radiol ; 29(10): 5322-5329, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30963270

RESUMO

OBJECTIVES: The purpose of this study was to compare the image quality of coronary computed tomography angiography (CTA) subjected to deep learning-based image restoration (DLR) method with images subjected to hybrid iterative reconstruction (IR). METHODS: We enrolled 30 patients (22 men, 8 women) who underwent coronary CTA on a 320-slice CT scanner. The images were reconstructed with hybrid IR and with DLR. The image noise in the ascending aorta, left atrium, and septal wall of the ventricle was measured on all images and the contrast-to-noise ratio (CNR) in the proximal coronary arteries was calculated. We also generated CT attenuation profiles across the proximal coronary arteries and measured the width of the edge rise distance (ERD) and the edge rise slope (ERS). Two observers visually evaluated the overall image quality using a 4-point scale (1 = poor, 4 = excellent). RESULTS: On DLR images, the mean image noise was lower than that on hybrid IR images (18.5 ± 2.8 HU vs. 23.0 ± 4.6 HU, p < 0.01) and the CNR was significantly higher (p < 0.01). The mean ERD was significantly shorter on DLR than on hybrid IR images, whereas the mean ERS was steeper on DLR than on hybrid IR images. The mean image quality score for hybrid IR and DLR images was 2.96 and 3.58, respectively (p < 0.01). CONCLUSIONS: DLR reduces the image noise and improves the image quality at coronary CTA. KEY POINTS: • Deep learning-based image restoration is a new technique that employs the deep convolutional neural network for image quality improvement. • Deep learning-based restoration reduces the image noise and improves image quality at coronary CT angiography. • This method may allow for a reduction in radiation exposure.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Aprendizado Profundo , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Razão Sinal-Ruído
7.
Radiol Artif Intell ; 1(6): e180011, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33937803

RESUMO

PURPOSE: To evaluate the effect of a deep learning-based reconstruction (DLR) method on the conspicuity of hypovascular hepatic metastases on abdominal CT images. MATERIALS AND METHODS: This retrospective study with institutional review board approval included 58 patients with hypovascular hepatic metastases. A radiologist recorded the standard deviation of attenuation in the paraspinal muscle as the image noise and the contrast-to-noise ratio (CNR). CNR was calculated as region of interest ([ROI]L - ROIT)/N, where ROIL is the mean liver parenchyma attenuation, ROIT, the mean tumor attenuation, and N, the noise. Two other radiologists graded the conspicuity of the liver lesion on a five-point scale where 1 is unidentifiable and 5 is detected without diagnostic compromise. Only the smallest liver lesion in each patient, classified as smaller or larger than 10 mm, was evaluated. The difference between hybrid iterative reconstruction (IR) and DLR images was determined by using a two-sided Wilcoxon signed-rank test. RESULTS: The image noise was significantly lower, and the CNR was significantly higher on DLR images than hybrid IR images (median image noise: 19.2 vs 12.8 HU, P < .001; median CNR: tumors < 10 mm: 1.9 vs 2.5; tumors > 10 mm: 1.7 vs 2.2, both P < .001). The scores for liver lesions were significantly higher for DLR images than hybrid IR images (P < .01 for both in tumors smaller or larger than 10 mm). CONCLUSION: DLR improved the quality of abdominal CT images for the evaluation of hypovascular hepatic metastases.© RSNA, 2019Supplemental material is available for this article.

8.
Eur Radiol ; 29(1): 161-167, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29934669

RESUMO

OBJECTIVES: The objective of this study was to investigate the usefulness of model-based iterative reconstruction (IR) for detecting neointimal formations after carotid artery stenting. METHODS: In a cervical phantom harbouring carotid artery stents, we placed simulated neointimal formations measuring 0.40, 0.60, 0.80 and 1.00 mm along the stent wall. The thickness of in-stent neointimal formations was measured on images reconstructed with filtered-back projection (FBP), hybrid IR (AIDR 3D), and model-based IR (FIRST). The clinical study included 43 patients with carotid stents. Cervical computed tomography (CT) images obtained on a 320-slice scanner were reconstructed with AIDR 3D and FIRST. Five blinded observers visually graded the likelihood of neointimal formations on AIDR 3D and AIDR 3D plus FIRST images. Carotid ultrasound images were the reference standard. We analysed results of visual grading by using a Jack-knife type receiver observer characteristics analysis software. RESULTS: In the phantom study, the difference between the measured and the true diameter of the neointimal formations was smaller on FIRST than FBP or AIDR 3D images. In the clinical study, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of AIDR 3D were 58%, 88%, 83%, 67% and 73%, respectively. For AIDR 3D plus FIRST images they were 84%, 78%, 80%, 82% and 81%, respectively. The mean area under the curve was significantly higher on AIDR 3D plus FIRST than AIDR 3D images (0.82 vs 0.72; p < 0.01). CONCLUSIONS: The model-based IR algorithm helped to improve diagnostic performance for the detection of neointimal formations after carotid artery stenting. KEY POINTS: • Neointimal formations can be visualised more accurately with model-based IR. • Model-based IR improves the detection of neointimal formations after carotid artery stenting. • Model-based IR is suitable for follow up after carotid artery stenting.


Assuntos
Artéria Carótida Primitiva/cirurgia , Estenose das Carótidas/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Imageamento Tridimensional , Tomografia Computadorizada Multidetectores/métodos , Stents , Procedimentos Cirúrgicos Vasculares/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artéria Carótida Primitiva/diagnóstico por imagem , Estenose das Carótidas/diagnóstico , Feminino , Humanos , Masculino , Neointima/diagnóstico por imagem , Imagens de Fantasmas , Curva ROC
9.
BJR Case Rep ; 4(2): 20170022, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30363145

RESUMO

Anastomosing haemangioma is a rare subtype of capillary haemangioma. Pathologically, anastomosing haemangioma presents with anastomosing sinusoidal capillary-sized vessels in an architecture reminiscent of the splenic parenchyma. Its anastomosing architecture pathologically can lead to concern for angiosarcoma. Many cases of anastomosing haemangioma, which often occurred in the retroperitoneum, were well circumscribed, hyperdense on plain CT, revealed avid contrast enhancement and some of them exhibited fatty changes. In cases of tumours with fat of retroperitoneal occurrence, images frequently do not allow for easy differentiation from liposarcoma. Although anastomosing haemangioma with fatty changes and liposarcoma can be difficult to differentiate, no previous report has addressed this diagnostic difficulty. We have encountered a case of anastomosing haemangioma with fatty changes occurring in the perirenal space that was difficult to differentiate from liposarcoma. With retroperitoneal tumours accompanied by fatty changes and including a strongly enhanced area, the possibility of anastomosing haemangioma-which is a benign tumour-may also be considered. In such cases, biopsy is an effective means of diagnosis.

10.
Medicine (Baltimore) ; 97(32): e11670, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30095624

RESUMO

The purpose of this study was to investigate the value of the cerebral blood volume (CBV) obtained with perfusion computed tomography (CT) and the electron density (ED) measured by dual-energy CT for differentiating high- from low-grade glioma (HGG, LGG).The CBV and ED were obtained in 9 LGG and 7 HGG patients. The CBV and ED of LGGs and HGGs were compared. Receiver operating characteristic (ROC) curves were generated for CBV, ED, and CBV plus ED. The correlation between CBV, ED, and the MIB-1 labeling index of the tumors was examined. All of these analyses were also performed using relative CBV (rCBV) and ED (rED) (the value of tumors/the value of contralateral white matter).The mean CBV, ED, rCBV, and rED values were significantly higher in HGG than LGG (P < .05). By ROC analysis, the combination of rCBV plus rED as well as CBV plus ED were more accurate than CBV, ED, rCBV, rED alone. There was a significant correlation between ED and MIB-1 (P = .04).ED improved diagnostic accuracy of perfusion CT for differentiating HGG from LGG.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Glioma/diagnóstico por imagem , Imagem de Perfusão/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Neoplasias Encefálicas/patologia , Feminino , Glioma/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estudos Retrospectivos
11.
Radiographics ; 38(4): 1131-1144, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29995614

RESUMO

Diffusion-weighted (DW) imaging is a magnetic resonance (MR) imaging method. It is an indispensable sequence for the diagnosis of acute cerebral infarction and is recognized as a standard tool in oncologic imaging. Computed DW imaging refers to the synthesizing of arbitrary b-value DW images from a set of measured b-value images by voxelwise fitting. Computed DW imaging is advantageous because it generates DW images with a higher diffusion effect than that achievable by using the MR imaging units in use today. Additionally, computed DW imaging can reduce imaging time while producing images characterized by a higher signal-to-noise ratio than what the acquired DW images would display at the corresponding b values. By fitting input images acquired at a lower b value and correspondingly a shorter echo time, the signal intensity of the resulting computed DW image is closer to the ideal case. Computed DW images are generated by employing mathematical models that use mono-, bi-, or triexponential equations. To generate accurate computed DW images, the appropriate model must be selected, and the image parameters for the input data must be chosen accordingly. In addition, to reduce artifacts on computed DW images, the misalignment of input data must be corrected with the aid of image registration techniques. ©RSNA, 2018.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Artefatos , Meios de Contraste , Humanos , Física
12.
Abdom Radiol (NY) ; 43(7): 1540-1545, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29796844

RESUMO

Tubulocystic renal cell carcinoma (TC-RCC) has been classified as an independent subtype according to the 2016 World Health Organization (WHO) classification. It is a rare subtype that predominantly affects men. Although few in number, radiological imaging reports have suggested that TC-RCC is characterized by multilocular cystic lesions, which are categorized as the Bosniak classification II-IV, with signature pathological characteristics comprising numerous small cysts or a tubular structure. The Bosniak classification system facilitates patient management; however, the differentiation of cystic tumors exhibiting similar imaging findings remains impossible; in fact, the differentiation of multilocular cystic RCC, adult cystic nephroma, and mixed epithelial and stromal tumor remains challenging. This review aims to discuss TC-RCC with a focus on implications of radiological findings in the differential diagnosis of TC-RCC.


Assuntos
Carcinoma de Células Renais/diagnóstico por imagem , Doenças Renais Císticas/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Rim/diagnóstico por imagem , Masculino , Tomografia Computadorizada por Raios X
13.
PLoS One ; 13(2): e0191347, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29474457

RESUMO

Arterial peak enhancement on contrast-enhanced CT (CECT) images is thought to be higher in patients with low cardiac function. Using computer simulations, we tested the hypothesis that the relationship between the cardiac index and the aortic peak CT number (PCTN) is affected by the contrast material (CM) injection duration. We created computer simulation software for the contrast enhancement of various organs and vessels based on the Bae pharmacokinetics model and implemented models for CM transmission within organs and CM diffusion in blood plasma based on the osmotic pressure. Aortic contrast enhancement at coronary- and abdominal CT angiographs (CTA) was simulated for a representative 60-year-old Japanese male 166 cm in height and 65.0 kg in weight. The injection protocol for coronary CTA was: CM dose 45.5 ml, iodine dose, 245 mg/kg body weight (BW); injection duration 8-20 sec in 2-sec increments. For abdominal CTA it was CM dose 74.3 ml; iodine dose 400 mg/kg BW; injection duration 10-40 sec in 5-sec increments. In both protocols the iodine concentration was 350 mgI/ml, osmotic pressure was 590 mOsm/kgH2O, and the cardiac index ranged from 0.1-6.0 l/min/m2. Under all protocols, the aortic PCTN increased as the injection duration decreased and as the cardiac index rose to the cardiac index value. It then decreased as it exceeded the cardiac index value. At coronary CTA, at an injection duration of 8 or 10 sec, the PCTN exceeded 350 Hounsfield units (HU) at a cardiac index from 0.9-5.6 l/min/m2. At an HU value greater than 350, the range of the cardiac index narrowed when the injection duration was 12 sec or longer. On abdominal CTA scans performed with an injection duration of 10-, 15-, or 20 sec, the PCTN exceeded 350 HU at a cardiac index ranging from 0.4-5.3 l/min/m2. When the injection duration ranged from 25-40 sec, there was narrowing of the range of the cardiac index at which the PCTN exceeded 350 HU. For coronary and abdominal CTA, contrast enhancement protocols with shorter injection durations yield a diagnostically adequate aortic PCTN at a wide range of cardiac indices.


Assuntos
Débito Cardíaco/fisiologia , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Simulação por Computador , Meios de Contraste/farmacocinética , Feminino , Hemodinâmica , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Estudos Retrospectivos , Software , Fatores de Tempo
14.
J Magn Reson Imaging ; 47(4): 928-935, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28842935

RESUMO

BACKGROUND: We developed a method to quantify the volume flow rate (VFR) using the time-spatial labeling inversion pulse (Time-SLIP) technique to evaluate salivary function. PURPOSE/HYPOTHESIS: To investigate the accuracy of quantification of the salivary VFR using the Time-SLIP technique in phantoms and to examine the feasibility of its use in human subjects. STUDY TYPE: This was a prospective phantom and volunteer study. POPULATION/SUBJECTS/PHANTOM/SPECIMEN/ANIMAL MODEL: A phantom and 23 normal volunteers who fasted at least 2 hours study was performed. FIELD STRENGTH/SEQUENCE: Flow images of the phantom and the parotid duct of 23 volunteers were acquired on a 3T-MRI scanner using the Time-SLIP technique. ASSESSMENT: Hypothesizing that flow aggregates in the conducting duct, we measured the VFR on flow images. In the phantom study, the actual VFR (slow, medium, fast flow) was controlled by an automatic pump system and the measured VFR was compared with the actual VFR on flow images. In the human study we injected citric acid into the mouth of healthy volunteers to stimulate saliva secretion and recorded the VFR. STATISTICAL TESTS: As this study was a feasibility study, statistical tests were not performed. RESULTS: In the phantom study, the VFR at slow, medium, and fast flow was 5.7 ± 0.4 (SD), 8.4 ± 0.3, and 12.2 ± 1.1 mm3 /sec, respectively. The error between the measured and actual VFR values was 2.8-3.7%. Salivary flow in the parotid duct was visualized in 22 of the 23 volunteers. The mean VFR was 8760 mm3 /10 min. DATA CONCLUSION: When salivary flow was stimulated with citric acid in normal volunteers, the salivary VFR could be obtained using the Time-SLIP technique. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:928-935.


Assuntos
Imageamento por Ressonância Magnética/métodos , Glândula Parótida/diagnóstico por imagem , Glândula Parótida/fisiologia , Saliva/diagnóstico por imagem , Processamento de Sinais Assistido por Computador , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes , Saliva/fisiologia , Tempo , Adulto Jovem
15.
Eur J Radiol ; 98: 41-49, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29279169

RESUMO

OBJECTIVES: To investigate whether hepatic perfusion CT yields early imaging biomarkers predictive of the prognosis of hepatocellular carcinoma (HCC) patients treated with sorafenib. METHODS: We evaluated 36 HCC patients who underwent hepatic perfusion CT before- and one week after sorafenib therapy. We measured arterial and portal perfusion in the hepatic tumor and liver parenchyma [(AP)(PP)tumor], [(AP)(PP)liver]. The perfusion ratio was calculated by dividing the post- by the pre-sorafenib value. The effect of each value on the overall survival rate was analyzed with the Cox proportional hazards model; statistically significant parameters were subjected to receiver operating characteristic analysis based on median survival after sorafenib administration to determine the overall survival rate with the Kaplan-Meier method. RESULTS: Pre-APtumor was significantly associated with the overall survival rate (hazard ratio (HR) and 95% confidence interval (CI), 0.16 and 0.02-0.84, p=0.03). The APtumor ratio tended to be associated with the overall survival rate (HR and 95% CI, 2.94 and 0.94-7.88, p=0.06). The overall survival rate was higher in patients with pre-APtumor>71.7mL/min/100mL, and with APtumor ratio≦1.1 (p<0.01 and 0.03, respectively, in Kaplan-Meier method with log-rank). CONCLUSION: Hepatic perfusion CT yields early imaging biomarkers for predicting overall survival in HCC patients treated with sorafenib.


Assuntos
Carcinoma Hepatocelular/tratamento farmacológico , Meios de Contraste , Neoplasias Hepáticas/tratamento farmacológico , Niacinamida/análogos & derivados , Compostos de Fenilureia/uso terapêutico , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Antineoplásicos/uso terapêutico , Biomarcadores , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Niacinamida/uso terapêutico , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Sorafenibe , Taxa de Sobrevida , Resultado do Tratamento
16.
J Comput Assist Tomogr ; 42(3): 373-379, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29287019

RESUMO

OBJECTIVE: To compare the utility of high-precision computed diffusion-weighted imaging (hc-DWI) and conventional computed DWI (cc-DWI) for the diagnosis of hepatocellular carcinoma (HCC) at 3 T. METHODS: We subjected 75 HCC patients to DWI (b-value 150 and 600 s/mm). To generate hc-DWI we applied non-rigid image registration to avoid the mis-registration of images obtained with different b-values. We defined c-DWI with a b-value of 1500 s/mm using DWI with b-value 150 and 600 s/mm as cc-DWI, and c-DWI with b-value 1500 s/mm using registered DWI with b-value 150 and 600 s/mm as hc-DWI. A radiologist recorded the contrast ratio (CR) between HCC and the surrounding hepatic parenchyma. RESULTS: The CR for HCC was significantly higher on hc- than cc-DWIs (median 2.0 vs. 1.8, P < 0.01). CONCLUSION: The CR of HCC can be improved with image registration, indicating that hc-DWI is more useful than cc-DWI for the diagnosis of HCC.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
17.
Br J Radiol ; 91(1082): 20170598, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29022741

RESUMO

OBJECTIVE: The purpose of our study was to compare the diagnostic performance of coronary CT angiography (CTA) subjected to model-based iterative reconstruction (IR) or hybrid IR to rule out coronary in-stent restenosis. METHODS: We enrolled 16 patients who harboured 22 coronary stents. They underwent coronary CTA on a 320-slice CT scanner. The images were reconstructed with hybrid IR (AIDR 3D) and model-based IR (FIRST) algorithms. We calculated the stent lumen attenuation increase ratio and measured the visible stent lumen diameter. Two blinded observers visually graded the likelihood of in-stent restenosis (lesions ≥ 50%) on hybrid IR and FIRST images. RESULTS: The stent lumen attenuation increase ratio on FIRST- was lower than on AIDR 3D images (0.20 vs 0.32). The ratio of the visible- compared to the true stent lumen diameter was higher on FIRST- than AIDR 3D images (52.5 vs 47.5%). Invasive coronary angiography identified five stents (22.7%) with significant in-stent restenosis. The use of FIRST improved the sensitivity (60 vs 100%), positive (75.0 vs 83.3%) and negative predictive value (88.9 vs 100%) and the accuracy (86.4 vs 95.5%) for the detection of in-stent restenosis. Specificity was 94.1% for both reconstruction methods. CONCLUSION: The model-based IR algorithm may improve diagnostic performance for the detection of in-stent restenosis. Advances in knowledge: Compared to hybrid IR, the new model-based IR algorithm reduced blooming artefacts and improved the image quality. It can be expected to improve diagnostic performance for the detection of in-stent restenosis on coronary CTA images.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Stents , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Sensibilidade e Especificidade
18.
Cardiovasc Intervent Radiol ; 41(4): 618-627, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29101449

RESUMO

PURPOSE: To identify factors benefiting from computed tomography during hepatic arteriography (CTHA) in addition to dynamic CT studies at the preoperative evaluation of the hypervascularity of hepatocellular carcinoma (HCC). MATERIALS AND METHODS: We retrospectively divided 45 patients with HCC, who underwent both dynamic CT (dCT) and CTHA, into two groups based on the number of hypervascular HCCs identified on dCT and CTHA studies. In group A, the number of HCCs identified by dCT and CTHA was the same and additive CTHA had not been indicated. In group B, fewer HCCs were counted on dCT than on CTHA images, indicating that additive CTHA studies had been appropriate. We compared the patient characteristics, the serum alpha-fetoprotein level, and the tumor-liver contrast (TLC) of the main tumor on dCT scans of both groups. To identify factors alerting to the benefit of additional CTHA studies, we performed univariate logistic regression analysis. Statistically significant parameters were subjected to receiver operating characteristic analysis for obtaining the optimal cutoff value indicative of the benefit of CTHA. RESULTS: Univariate analysis identified only the TLC of the main tumor on dCT images as a significant factor for the benefit of CTHA images (P < 0.01). At the optimal cutoff value for the TLC of the main tumor on dCT images (15.9 Hounsfield units), the sensitivity and specificity for the benefit of CTHA were 85.0 and 92.0%, respectively. CONCLUSION: Evaluation of the TLC of the main tumor on dCT scans identifies patients in whom additive CTHA studies are beneficial.


Assuntos
Angiografia/métodos , Carcinoma Hepatocelular/irrigação sanguínea , Artéria Hepática/diagnóstico por imagem , Neoplasias Hepáticas/irrigação sanguínea , Neovascularização Patológica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade
20.
Data Brief ; 13: 437-443, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28702482

RESUMO

This article describes a quantitative evaluation of visualizing small vessels using several image reconstruction methods in computed tomography. Simulated vessels with diameters of 1-6 mm made by 3D printer was scanned using 320-row detector computed tomography (CT). Hybrid iterative reconstruction (hybrid IR) and model-based iterative reconstruction (MBIR) were performed for the image reconstruction.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA