Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
2.
Cytometry B Clin Cytom ; 88(3): 194-203, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-24753208

RESUMO

Multiparameter flow cytometry is a highly sensitive, fast, and specific diagnostic technology with a wide range of applicability in hematology. Although well-established eight-color immunophenotyping panels are already available, most Brazilian clinical laboratories are equipped with four-color flow cytometer facilities. Based on this fact, the Brazilian Group of Flow Cytometry (Grupo Brasileiro de Citometria de Fluxo, GBCFLUX) for standardization of clinical flow cytometry has proposed an antibody panel designed to allow precise diagnosis and characterization of acute leukemia (AL) within resource-restricted areas. Morphological analysis of bone marrow smears, together with the screening panel, is mandatory for the primary identification of AL. The disease-oriented panels proposed here are divided into three levels of recommendations (mandatory, recommendable, and optional) in order to provide an accurate final diagnosis, as well as allow some degree of flexibility based on available local resources and patient-specific needs. The proposed panels will be subsequently validated in an interlaboratory study to evaluate its effectiveness on the diagnosis and classification of AL. (Assoc editor comm. 2).


Assuntos
Biomarcadores Tumorais/imunologia , Citometria de Fluxo/normas , Imunofenotipagem/normas , Leucemia Mieloide Aguda/diagnóstico , Linfócitos/imunologia , Células Mieloides/imunologia , Leucemia-Linfoma Linfoblástico de Células Precursoras/diagnóstico , Anticorpos/química , Antígenos CD/genética , Antígenos CD/imunologia , Biomarcadores Tumorais/genética , Brasil , Cor , Análise Citogenética , Citometria de Fluxo/métodos , Corantes Fluorescentes , Humanos , Imunofenotipagem/métodos , Leucemia Mieloide Aguda/genética , Leucemia Mieloide Aguda/imunologia , Leucemia Mieloide Aguda/patologia , Linfócitos/classificação , Linfócitos/patologia , Células Mieloides/classificação , Células Mieloides/patologia , Guias de Prática Clínica como Assunto , Leucemia-Linfoma Linfoblástico de Células Precursoras/genética , Leucemia-Linfoma Linfoblástico de Células Precursoras/imunologia , Leucemia-Linfoma Linfoblástico de Células Precursoras/patologia
3.
Artigo em Inglês | MEDLINE | ID: mdl-24700616

RESUMO

Multiparameter flow cytometry (MFC) is a highly sensitive, fast and specific diagnostic technology with a wide range of applicability in hematology. Although well-established eight-color immunophenotyping panels are already available, most Brazilian clinical laboratories are equipped with four-color flow cytometer facilities. Based on this fact, the Brazilian Group of Flow Cytometry (Grupo Brasileiro de Citometria de Fluxo, GBCFLUX) for standardization of clinical flow cytometry has proposed an antibody panel designed to allow precise diagnosis and characterization of acute leukemia (AL) within resource-restricted areas. Morphological analysis of bone marrow smears, together with the screening panel, is mandatory for the primary identification of AL. The disease-oriented panels proposed here are divided into three levels of recommendations (mandatory, recommendable and optional) in order to provide an accurate final diagnosis, as well as allow some degree of flexibility based on available local resources and patient-specific needs. The proposed panels will be subsequently validated in an inter-laboratory study to evaluate its effectiveness on the diagnosis and classification of AL. © 2014 Clinical Cytometry Society.

4.
Theriogenology ; 80(7): 730-7, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-23932173

RESUMO

Cryopreservation of spermatozoa is a pivotal tool in assisted reproduction, and studies aiming to establish optimal freezing/thawing protocols are essential to enhance sperm survival. The objectives of the present study were to (1) compare the cryoprotective efficiency of three different glycerol concentrations (3%, 5%, and 7%) on the basis of post-thaw sperm quality and (2) investigate whether the incidence of morphologically abnormal sperm in fresh samples is related to cryodamage sensitivity. Semen was collected from six tomcats using an artificial vagina (total 18 ejaculates). Each ejaculate was diluted using Tris-egg yolk-based extender (TEY), evaluated, equally divided into three aliquots, and rediluted using TEY with and without glycerol to achieve final concentrations of 3%, 5%, and 7%. Samples were loaded into 0.25 mL straws, equilibrated for 60 minutes at 5 °C, frozen, and then thawed at 46 °C for 12 seconds. Fresh and frozen-thawed samples were evaluated for sperm motion parameters (computer-assisted sperm analysis), plasma membrane integrity (PMI; propidium iodide and carboxyfluorescein diacetate), and DNA integrity (acridine orange). Plasma and acrosomal membrane integrity were assessed by flow cytometry (propidium iodide and fluorescein isothiocyanate-conjugated pea (Pisum sativum) agglutinin) immediately after thawing. Sperm motion parameters were also evaluated at 30 and 60 minutes of postincubation. For all treatment groups, cryopreservation significantly impaired the PMI and sperm motion parameters, except for straightness and amplitude of lateral head displacement. DNA integrity showed a slight reduction (P < 0.05) when 3% glycerol was used. The percentage of total motility, progressive motility, and rapid spermatozoa were significantly lower immediately after thawing and up to 60 minutes of incubation for the 3% glycerol group when compared with 5% and 7%. No difference (P > 0.05) was found for PMI, acrosome integrity, and DNA integrity among post-thaw groups. However, higher (P < 0.05) incidence of viable cells with reacted acrosome and dead cells with intact acrosome were observed with 7% and 3% glycerol, respectively. Percentage of morphologically abnormal spermatozoa in fresh sample was positively correlated with PMI only in the 3% glycerol group and negatively correlated with sperm motility in the 5% and 7% groups. In conclusion, the final concentration of 5% glycerol offered better cryoprotective effect for ejaculated cat sperm, and the relationship found between prefreezing sperm morphology and post-thaw sperm quality showed to be dependent on final glycerol concentration.


Assuntos
Crioprotetores/farmacologia , Glicerol/farmacologia , Espermatozoides/efeitos dos fármacos , Acrossomo/efeitos dos fármacos , Animais , Gatos , Criopreservação/métodos , Criopreservação/veterinária , Masculino , Análise do Sêmen/veterinária
5.
Leuk Res ; 33(1): 19-27, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18789822

RESUMO

Myelodysplastic syndrome (MDS) is a rare hematological malignancy in children. It was performed FISH analysis in 19 pediatric MDS patients to investigate deletions involving the PPARgamma and TP53 genes. Significant losses in the PPARgamma gene and deletions in the tumor suppressor gene TP53 were observed in 17 and 18 cases, respectively. Using quantitative RT-PCR, it was detected PPARgamma transcript downexpression in a subset of these cases. G-banding analysis revealed 17p deletions in a small number of these cases. One MDS therapy-related patient had neither a loss of PPARgamma nor TP53. These data suggest that the PPARgamma and TP53 genes may be candidates for molecular markers in pediatric MDS, and that these potentially recurrent deletions could contribute to the identification of therapeutic approaches in primary pediatric MDS.


Assuntos
Deleção de Genes , Síndromes Mielodisplásicas/genética , PPAR gama/genética , Proteína Supressora de Tumor p53/genética , Adolescente , Criança , Pré-Escolar , Bandeamento Cromossômico , Feminino , Humanos , Hibridização in Situ Fluorescente , Lactente , Cariotipagem , Masculino , Reação em Cadeia da Polimerase Via Transcriptase Reversa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA