Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
PLoS One ; 19(2): e0271711, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38421965

RESUMO

PURPOSE: Prior to 90Y radioembolization procedure, a pretherapy simulation using 99mTc-MAA is performed. Alternatively, a small dosage of 90Y microspheres could be used. We aimed to assess the accuracy of lung shunt fraction (LSF) estimation in both high activity 90Y posttreatment and pretreatment scans with isotope activity of ~100 MBq, using different imaging techniques. Additionally, we assessed the feasibility of visualising hot and cold hepatic tumours in PET/CT and Bremsstrahlung SPECT/CT images. MATERIALS AND METHODS: Anthropomorphic phantom including liver (with two spherical tumours) and lung inserts was filled with 90Y chloride to simulate an LSF of 9.8%. The total initial activity in the liver was 1451 MBq, including 19.4 MBq in the hot sphere. Nine measurement sessions including PET/CT, SPECT/CT, and planar images were acquired at activities in the whole phantom ranging from 1618 MBq down to 43 MBq. The visibility of the tumours was appraised based on independent observers' scores. Quantitatively, contrast-to-noise ratio (CNR) was calculated for both spheres in all images. RESULTS: LSF estimation. For high activity in the phantom, PET reconstructions slightly underestimated the LSF; absolute difference was <1.5pp (percent point). For activity <100 MBq, the LSF was overestimated. Both SPECT and planar scintigraphy overestimated the LSF for all activities. Lesion visibility. For SPECT/CT, the cold tumour proved too small to be discernible (CNR <0.5) regardless of the 90Y activity in the liver, while hot sphere was visible for activity >200 MBq (CNR>4). For PET/CT, the cold tumour was only visible with the highest 90Y activity (CNR>4), whereas the hot one was seen for activity >100 MBq (CNR>5). CONCLUSIONS: PET/CT may accurately estimate the LSF in a 90Y posttreatment procedure. However, at low activities of about 100 MBq it seems to provide unreliable estimations. PET imaging provided better visualisation of both hot and cold tumours.


Assuntos
Neoplasias Hepáticas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Radioisótopos de Ítrio/uso terapêutico , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada de Emissão de Fóton Único , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia
2.
Sci Rep ; 11(1): 4472, 2021 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-33627727

RESUMO

We propose a new in vitro model to assess the impact of 90Y-microspheres derived low-dose beta radiation on colorectal cancer cell line under various oxygenation conditions that mimic the tumor environment. Cancer cells (HCT116) proliferation was assessed using Alamar Blue (AB) assay after 48, 72, and 96 h. FLUKA code assessed changes in cancer cell populations relative to the absorbed dose. In normoxia, mitochondrial activity measured by Alamar Blue after 48-72 h was significantly correlated with the number of microspheres (48 h: r = 0.87 and 72 h: r = 0.89, p < 0.05) and absorbed dose (48 h: r = 0.87 and 72 h: r = 0.7, p < 0.05). In hypoxia, the coefficients were r = 0.43 for both the number of spheres and absorbed dose and r = 0.45, r = 0.47, respectively. Impediment of cancer cell proliferation depended on the absorbed dose. Doses below 70 Gy could reduce colorectal cancer cell proliferation in vitro. Hypoxia induced a higher resistance to radiation than that observed under normoxic conditions. Hypoxia and radiation induced senescence in cultured cells. The new in vitro model is useful for the assessment of 90Y radioembolization effects at the micro-scale.


Assuntos
Partículas beta/uso terapêutico , Neoplasias Colorretais/radioterapia , Radioisótopos de Ítrio/administração & dosagem , Proliferação de Células/efeitos da radiação , Células HCT116 , Humanos , Hipóxia/radioterapia , Microesferas , Mitocôndrias/efeitos da radiação , Radiometria/métodos
3.
PLoS One ; 16(2): e0246848, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33566845

RESUMO

INTRODUCTION: We aimed to assess the feasibility of SPECT and PET Y-90 imaging, and to compare these modalities by visualizing hot and cold foci in phantoms for varying isotope concentrations. MATERIALS AND METHODS: The data was acquired from the Jaszczak and NEMA phantoms. In the Jaszczak phantom Y-90 concentrations of 0.1 MBq/ml and 0.2 MBq/ml were used, while higher concentrations, up to 1.0 MBq/ml, were simulated by acquisition time extension with respect to the standard clinical protocol of 30 sec/projection for SPECT and 30 min/bed position for PET imaging. For NEMA phantom, the hot foci had concentrations of about 4 MB/ml and the background 0.1 or 0.0 MBq/ml. All of the acquired data was analysed both qualitatively and quantitatively. Qualitative assessment was conducted by six observers asked to identify the number of visible cold or hot foci. Inter-observer agreement was assessed. Quantitative analysis included calculations of contrast and contrast-to-noise ratio (CNR), and comparisons with the qualitative results. RESULTS: For SPECT data up to two cold foci were discernible, while for PET four foci were visible. We have shown that CNR (with Rose criterion) is a good measure of foci visibility for both modalities. We also found good concordance of qualitative results for the Jaszczak phantom studies between the observers (corresponding Krippendorf's alpha coefficients of 0.76 to 0.84). In the NEMA phantom without background activity all foci were visible in SPECT/CT images. With isotope in the background, 5 of 6 spheres were discernible (CNR of 3.0 for the smallest foci). For PET studies all hot spheres were visible, regardless of the background activity. CONCLUSIONS: PET Y-90 imaging provided better results than Bremsstrahlung based SPECT imaging. This indicates that PET/CT might become the method of choice in Y-90 post radioembolization imaging for visualisation of both necrotic and hot lesions in the liver.


Assuntos
Imagens de Fantasmas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Radioisótopos de Ítrio , Humanos
4.
J Clin Med ; 8(10)2019 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-31554288

RESUMO

Introduction: This study was designed to assess quantitatively a safe position of the microcatheter during the SIRT (Selective Internal Radiation Therapy) procedure, in order to minimize the risk of non-target spheres leaking. Materials and Methods: Retrospective analysis of the distance of the tip of the microcatheter from coiled or patent non-target arteries was measured during 99mTc-MAA work-up procedure. Frequency of extrahepatic leaking during work-up and SIRT procedures was evaluated. Results: There were 85 patients who underwent 98 work-up procedures. There were 64 radioembolizations. There were 44 gastroduodenal, 51 right gastric, and 54 cystic artery embolizations performed. Extrahepatic 99mTc-MAA leaking was observed in 33 cases: 16 to gallbladder, four to a gastric wall, nine to the duodenum, one to the intestinal wall, and three to the abdominal wall. Leak in 99mTc-MAA was also related to the presence of additional arteries (p = 0.009). There were 34 proximal and 31 distal to cystic artery 99mTc-MAA injections resulting in 12 vs. four leaks, respectively (p = 0.039, RR-2.5). Mean distance of the tip of the microcatheter from the origin of the cystic artery was 20 mm (minimum of 2.1 mm and maximum of 53 mm) proximally and 10 mm (minimum 1 mm and maximum 51 mm) distally (ns). Conclusions: Leaking in 99mTc-MAA (99mTc - labelled macroaggregated albumin) was related to the presence of additional arteries. Regardless of cystic artery embolization, it is 2.5 times safer to inject microspheres distal to its origin, compared to proximal injection. Cystic artery origin relative to the right hepatic artery division usually necessitates embolization of the former.

5.
Mater Sci Eng C Mater Biol Appl ; 67: 629-635, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27287162

RESUMO

A new technology for the production of radiopharmaceutical (90)Y microspheres in the form of spherical yttrium oxide grains obtained by sol-gel method has been described. The authors present and discuss the results of investigations performed in the development of new production technology of yttrium microspheres and determination of their physic-chemical properties. The final product has the structure of spherical yttrium oxide grains with a diameter 25-100µm, is stable and free from contaminants. Irradiation of 20mg samples of grains with diameter of 20-50µm in the thermal neutron flux of 1.7×10(14)cm(-2)s(-1) at the core of MARIA research nuclear reactor allowed to obtain microspheres labelled with the (90)Y isotope on the way of the nuclear reaction (89)Y(n, ɤ)(90)Y. Specific activity of irradiated microspheres has been determined by application of absolute triple to double coincidence ratio method (TDCR) and has been evaluated at 190MBq/mg Y. (90)Y microspheres prepared by the proposed technique can be regarded as a promising medical material for radioembolization of liver malignancies.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas/terapia , Microesferas , Compostos Radiofarmacêuticos , Radioisótopos de Ítrio , Humanos , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/farmacocinética , Compostos Radiofarmacêuticos/farmacologia , Radioisótopos de Ítrio/química , Radioisótopos de Ítrio/farmacocinética , Radioisótopos de Ítrio/farmacologia
6.
Appl Radiat Isot ; 75: 115-27, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23501361

RESUMO

The gel composites of WO3-ZrO2, WO3-TiO2, WO3-ZrO2-SiO2 at different molar ratios of oxides were synthesized. The elution profiles of the generator columns packed with gel samples activated at the Polish nuclear research reactor MARIA were studied. The best results of elution were found for WO3-ZrO2 and WO3-TiO2 both at 1:2M ratio annealed at 500°C and 650°C, respectively. Their structure determined with X-ray and neutron diffraction is completely amorphous with spherical grains of ∼23nm diameter. The efficiency of (188)W/(188)Re generators with WO3-ZrO2 gel of natural isotope composition as well as enriched in (186)W were investigated.


Assuntos
Óxidos/química , Radioisótopos/química , Compostos Radiofarmacêuticos/síntese química , Rênio/química , Tungstênio/química , Géis , Óxidos/síntese química , Dióxido de Silício/química , Titânio/química , Zircônio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA