RESUMO
OBJECTIVES: The diagnostic yield and clinical impact of image-guided core needle biopsy (ICNB) of suspected vertebral osteomyelitis in adults is heterogenous in published studies owing to small sample sizes, indicating the need for large cohort studies. METHODS: A retrospective analysis of ICNBs was performed from 2010 to 2021 for patients with imaging findings consistent with vertebral osteomyelitis. For each biopsy, a series of factors were analyzed, as well as if histopathology was diagnostic of osteomyelitis and if microbiological cultures were positive. In addition, it was recorded in what way biopsy influenced clinical management regarding antimicrobial treatment. A multivariate statistical analysis was performed to evaluate the factors associated with yield. RESULTS: A total of 570 biopsies performed on 527 patients were included. A histopathologic diagnosis of osteomyelitis was made in 68.4% (359 of 525) of biopsies, and microbiological cultures were positive in 29.6% (169 of 570). Elevated erythrocyte sedimentation rate was positively associated with a histopathologic diagnosis of osteomyelitis (odds ratio [OR] =1.96, P = 0.007) and positive cultures from bone cores (OR = 1.02, P ≤0.001) and aspirate (OR = 1.02, P ≤0.001). Increased total core length was positively associated with a histopathologic diagnosis of osteomyelitis (OR = 1.81, P = 0.013) and positive cultures from bone cores (OR = 1.65, P = 0.049). Clinical management was affected by ICNB in 37.5% (214 of 570) of cases. CONCLUSIONS: In this large cohort, ICNB yielded approximately 30% positive cultures and changed clinical management in over one-third of the patients.
Assuntos
Biópsia Guiada por Imagem , Osteomielite , Humanos , Osteomielite/diagnóstico , Osteomielite/microbiologia , Osteomielite/patologia , Osteomielite/tratamento farmacológico , Estudos Retrospectivos , Masculino , Biópsia Guiada por Imagem/métodos , Feminino , Pessoa de Meia-Idade , Biópsia com Agulha de Grande Calibre/métodos , Idoso , Adulto , Idoso de 80 Anos ou mais , Coluna Vertebral/patologia , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/microbiologia , Doenças da Coluna Vertebral/diagnóstico , Doenças da Coluna Vertebral/microbiologia , Doenças da Coluna Vertebral/patologia , Doenças da Coluna Vertebral/tratamento farmacológicoRESUMO
OBJECTIVES: To evaluate diagnostic yield and accuracy of image-guided core needle biopsy (ICNB) of suspected malignant osseous lesions in a large cohort of adults, evaluate what factors influence these measures, and offer technical recommendations to optimize yield. METHODS: A retrospective analysis of 2321 ICNBs performed from 2010 to 2021 was completed. The diagnostic yield and accuracy of the biopsies as well as a series of patient, lesion-related, and technical factors were retrospectively analyzed. Multivariate statistical analysis was performed to evaluate what factors were associated with yield and accuracy. Different cutoff values of total core length and core number were then tested to determine threshold values in relation to increased diagnostic yield. RESULTS: Diagnostic yield was 98.2% (2279/2321) and accuracy was 97.6% (120/123). Increased total core length (odds ratio [OR] = 2.34, 95% confidence interval [CI] (1.41-3.90), p = 0.001), core number (OR = 1.51, 95% CI (1.06-2.16), p = 0.02) and presence of primary malignancy (OR = 2.81, 95% CI (1.40-5.62), p = 0.004) were associated with improved yield. Lesion location in an extremity (OR = 0.27, 95% CI (0.11-0.68), p = 0.006) and using fluoroscopic imaging guidance (OR = 0.33, 95% CI (0.12-0.90), p = 0.03) were associated with lower yield. Cutoff thresholds in relation to increased diagnostic yield were found to be 20 mm total core length (marginal OR = 4.16, 95% CI = (2.09-9.03), p < 0.001), and three total cores obtained (marginal OR = 2.78, 95% CI (1.34-6.54), p = 0.005). None of the analyzed factors influenced diagnostic accuracy. CONCLUSIONS: ICNB has a high rate of diagnostic yield and accuracy. Several factors influence diagnostic yield; 20 mm core length and three total cores optimize yield. CLINICAL RELEVANCE STATEMENT: Image-guided core needle biopsy of suspected malignant osseous lesions is a safe procedure with a very high rate of diagnostic yield and accuracy. Obtaining 20 mm total core length and three total cores optimizes diagnostic yield. KEY POINTS: ⢠In a retrospective cohort study, image-guided core needle biopsy of suspected osseous malignant lesions in adults was found to have very high rates of diagnostic yield and accuracy. ⢠Increased total core length and core number of biopsies were each associated with increased diagnostic yield, and these relationships reached thresholds at 20 mm total core length and three total cores obtained. ⢠The presence of a known primary malignancy was also associated with increased yield while using fluoroscopic imaging guidance and lesion location in an extremity were associated with decreased yield.