Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
2.
Catheter Cardiovasc Interv ; 98(5): 904-913, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34398509

RESUMO

The Society for Cardiovascular Angiography and Interventions (SCAI) Think Tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community annually for high-level field-wide discussions. The 2021 Think Tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease. Each session was moderated by a senior content expert and co-moderated by a member of SCAI's Emerging Leader Mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialog from a broader base, and thereby aid SCAI, the industry community and external stakeholders in developing specific action items to move these areas forward.


Assuntos
Cardiologistas , Cardiologia , Cardiopatias Congênitas , Angiografia , Humanos , Resultado do Tratamento
3.
Cardiol Young ; 31(10): 1563-1570, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34304753

RESUMO

BACKGROUND: Although rare, coronary artery anomalies can have significant clinical implications. Total anomalous origin of the coronary arteries from the pulmonary artery (TCAPA) represents a rare subtype of coronary artery anomaly for which little is known. The aim of this review was to characterise the presentation, utilised diagnostic modalities, associated cardiac lesions, and treatment strategies in patients with TCAPA. METHODS: A systematic review was performed for cases of TCAPA using PubMed, Embase, and Web of Science. Keywords searched included "total anomalous origin of the coronary arteries from the pulmonary artery," "single ostium anomalous coronary artery from the pulmonary artery," and "anomalous origin of both coronary arteries from the pulmonary artery." RESULTS: Fifty-seven cases of TCAPA were identified in 50 manuscripts. Fifty-eight per cent of patients were male and the median age at presentation was 10 days (mean 1.71 ± 6.6 years, range 0 days-39 years). Most patients were symptomatic at the time of presentation; cyanosis (n = 22) and respiratory distress (n = 14) were the most common symptoms. Cases were most commonly diagnosed at autopsy (n = 26, 45.6%), but operative intervention was pursued in 22 cases (45.6%); aortic re-implantation (n = 14) and a Takeuchi-type repair (n = 7) were the most common routes of repair. CONCLUSIONS: The clinical presentation of patients with TCAPA was found to be variable, likely related to the presence of associated cardiac lesions. TCAPA should be considered in patients with suspected anomalous origin of the left coronary artery from the pulmonary artery for the serious consequences that can occur if not promptly corrected.


Assuntos
Doença da Artéria Coronariana , Anomalias dos Vasos Coronários , Anomalias dos Vasos Coronários/diagnóstico , Anomalias dos Vasos Coronários/epidemiologia , Cianose , Humanos , Recém-Nascido , Masculino , Artéria Pulmonar/diagnóstico por imagem
4.
AJP Rep ; 11(2): e84-e90, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34150354

RESUMO

Pulse oximetry oxygen saturation (SpO 2 )-based critical congenital heart disease (CCHD) screening is effective in detection of cyanotic heart lesions. We report a full-term male infant with normal perfusion who had passed the CCHD screening at approximately 24 hours after birth with preductal SpO 2 of 99% and postductal SpO 2 of 97%. Detection of a loud systolic cardiac murmur before discharge led to the diagnosis of pulmonary atresia (PA) with ventricular septal defect (PA-VSD) by echocardiogram. The infant was transferred to a tertiary care center after initiation of prostaglandin E1 (PGE1) therapy. Throughout the initial course, he was breathing comfortably without respiratory distress or desaturations on pulse oximetry. We believe that this is the first documented report of PA missed by CCHD screening. Thorough and serial clinical examinations of the newborn infant proved vital in the timely diagnosis of this critical disease. We review the hemodynamics and the recent literature evaluating utility of CCHD screening in the diagnosis of PA-VSD. Pulse oximetry-based CCHD screening should be considered a tool to enhance CCHD detection with an emphasis on detailed serial physical examinations in newborn infants.

5.
J Invasive Cardiol ; 32(5): E103-E109, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32269177

RESUMO

BACKGROUND: The novel coronavirus (COVID-19) pandemic has placed severe stress on healthcare systems around the world. There is limited information on current practices in pediatric cardiac catheterization laboratories in the United States (US). OBJECTIVES: To describe current practice patterns and make recommendations regarding potential resource allocation for congenital cardiac catheterization during the COVID-19 pandemic. METHODS: A web-based survey was distributed regarding case candidacy and catheterization laboratory preparedness. Centers were categorized based on the current degree of disease burden in that community (as of April 1, 2020). Data and consensus opinion were utilized to develop recommendations. RESULTS: Respondents belonged to 56 unique US centers, with 27 (48.2%) located in counties with a high number of COVID-19 cases. All centers have canceled elective procedures. There was relative uniformity (>88% agreement) among centers as to which procedures were considered elective. To date, only three centers have performed a catheterization on a confirmed COVID-19 positive patient. Centers located in areas with a higher number of COVID-9 cases have been more involved in a simulation of donning and doffing personal protective equipment (PPE) than low-prevalence centers (46.7% vs 10.3%, respectively; P<.001). Currently, only a small fraction of operators has been reassigned to provide clinical services outside their scope of practice. CONCLUSIONS: At this stage in the COVID-19 pandemic, pediatric/congenital catheterization laboratories have dramatically reduced case volumes. This document serves to define current patterns and provides guidance and recommendations on the preservation and repurposing of resources to help pediatric cardiac programs develop strategies for patient care during this unprecedented crisis.


Assuntos
Cateterismo Cardíaco/métodos , Infecções por Coronavirus/complicações , Alocação de Recursos para a Atenção à Saúde/métodos , Pneumonia Viral/complicações , Betacoronavirus , COVID-19 , Criança , Infecções por Coronavirus/epidemiologia , Tomada de Decisões , Cardiopatias Congênitas , Humanos , Unidades de Terapia Intensiva Pediátrica , Pandemias , Equipamento de Proteção Individual , Pneumonia Viral/epidemiologia , Alocação de Recursos , SARS-CoV-2 , Inquéritos e Questionários , Estados Unidos/epidemiologia
7.
Catheter Cardiovasc Interv ; 96(3): 626-632, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32216096

RESUMO

OBJECTIVES: We aimed to evaluate the effect of technical aspects of fetal aortic valvuloplasty (FAV) on procedural risks and pregnancy outcomes. BACKGROUND: FAV is performed in cases of severe mid-gestation aortic stenosis with the goal of preventing hypoplastic left heart syndrome (HLHS). METHODS: The International Fetal Cardiac Intervention Registry was queried for fetuses who underwent FAV from 2002 to 2018, excluding one high-volume center. RESULTS: The 108 fetuses had an attempted cardiac puncture (mean gestational age [GA] 26.1 ± 3.3 weeks). 83.3% of attempted interventions were technically successful (increased forward flow/new aortic insufficiency). The interventional cannula was larger than 19 g in 70.4%. More than one cardiac puncture was performed in 25.0%. Intraprocedural complications occurred in 48.1%, including bradycardia (34.1%), pericardial (22.2%) or pleural effusion (2.7%) requiring drainage, and balloon rupture (5.6%). Death within 48 hr occurred in 16.7% of fetuses. Of the 81 patients born alive, 59 were discharged home, 34 of whom had biventricular circulation. More than one cardiac puncture was associated with higher complication rates (p < .001). Larger cannula size was associated with higher pericardial effusion rates (p = .044). On multivariate analysis, technical success (odds ratio [OR] = 10.9, 95% confidence interval [CI] = 2.2-53.5, p = .003) and later GA at intervention (OR = 1.5, 95% CI = 1.2-1.9, p = .002) were associated with increased odds of live birth. CONCLUSIONS: FAV is an often successful but high-risk procedure. Multiple cardiac punctures are associated with increased complication and fetal mortality rates. Later GA at intervention and technical success were independently associated with increased odds of live birth. However, performing the procedure later in gestation may miss the window to prevent progression to HLHS.


Assuntos
Estenose da Valva Aórtica/terapia , Valvuloplastia com Balão , Cateterismo Cardíaco , Terapias Fetais , Síndrome do Coração Esquerdo Hipoplásico/prevenção & controle , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Europa (Continente) , Feminino , Morte Fetal/etiologia , Terapias Fetais/efeitos adversos , Terapias Fetais/mortalidade , Humanos , Síndrome do Coração Esquerdo Hipoplásico/mortalidade , Nascido Vivo , América do Norte , Gravidez , Sistema de Registros , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento , Ultrassonografia Pré-Natal
8.
Cardiol Young ; 30(2): 256-262, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31831087

RESUMO

OBJECTIVE: Stenting of ostial pulmonary artery stenosis presents several unique challenges. These include difficulty in defining anatomy and need for precise stent placement in order to avoid missing the ostial stenosis or jailing either the contralateral branch pulmonary artery or the ipsilateral upper lobe branch. DESIGN: A retrospective review of outcomes was conducted in 1.5 or 2-ventricle patients who underwent stent placement for ostial branch pulmonary artery stenosis. Specific catheterisation lab techniques were reviewed. RESULTS: Forty-seven branch pulmonary arteries underwent stent placement for ostial stenosis in 43 patients. The median age and weight were 3.7 (0.3-18.1) years and 14.2 (5.6-70.0) kg, respectively. Three (2-8) angiographic projections were needed to profile the ostial stenosis. Open-cell stents were used in 23 and stents were modified in 5 cases. Following stent implantation, the minimum diameter improved from 3.6 (0.8-10.5) to 8.1 (4.2-16.5) mm (p < 0.001). The gradient improved from 21 (0-66) to 4 (0-27) mmHg (p < 0.001). Stent malposition occurred in eight (17%) of the stents placed. Five migrated distally causing suboptimal ostial coverage necessitating placement of a second stent in four. Three migrated proximally and partially jailed the contralateral pulmonary artery. Intentional jailing of the upper lobe branch occurred in four additional cases. At a follow-up of 2.4 (0.3-4.9) years, 15 stents underwent further dilation and 1 had a second stent placed within the exiting stent. CONCLUSION: Ostial branch pulmonary artery stenosis may require additional angiography to accurately define the ostial stenosis. Treatment with stents is effective but carries high rates of stent malposition.


Assuntos
Angioplastia com Balão/efeitos adversos , Migração de Corpo Estranho/etiologia , Artéria Pulmonar/cirurgia , Estenose de Artéria Pulmonar/cirurgia , Stents , Adolescente , Angiografia , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Masculino , Complicações Pós-Operatórias , Estudos Retrospectivos , Estenose de Artéria Pulmonar/etiologia , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 94(4): 598-606, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31441590
10.
Catheter Cardiovasc Interv ; 94(5): 732-737, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30983081

RESUMO

The need for creation or enlargement of a ventricular septal defect (VSD) is a rare occurrence. It is most frequently required in patients with double-outlet right ventricle who develop restriction of a remote muscular VSD or obstruction of a perimembranous VSD secondary to atrioventricular (AV) valve attachments to the interventricular septum. Surgical and transcatheter options for VSD creation or enlargement are associated with several risks including heart block, AV valve injury, and perforation. We report the first description of a hybrid approach to VSD creation and enlargement in two patients.


Assuntos
Cateterismo Cardíaco/instrumentação , Procedimentos Cirúrgicos Cardíacos , Comunicação Interventricular/terapia , Stents , Pré-Escolar , Feminino , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/fisiopatologia , Humanos , Recém-Nascido , Masculino , Desenho de Prótese , Resultado do Tratamento
11.
Cardiol Young ; 29(2): 235-237, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30511601

RESUMO

A 15-month-old child underwent percutaneous expansion of a Melody transcatheter pulmonary valve in the mitral position to accommodate growth after initial surgical implantation during infancy, but transiently decompensated after valvuloplasty owing to stent malformation. The Melody valve in the mitral position of small patients can be further expanded by percutaneous dilation, but there are a number of potential complications and technical improvements to consider.


Assuntos
Anormalidades Múltiplas , Valvuloplastia com Balão/métodos , Cateterismo Cardíaco/métodos , Defeitos dos Septos Cardíacos/diagnóstico , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Bioprótese , Ecocardiografia Transesofagiana , Feminino , Defeitos dos Septos Cardíacos/cirurgia , Humanos , Lactente , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Desenho de Prótese
12.
Pediatrics ; 141(Suppl 5): S416-S420, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29610163

RESUMO

Central venous thromboses are common and pose challenges in the care of chronically ill pediatric patients. Among patients with intestinal failure (most commonly because of short bowel syndrome) who depend on parenteral nutrition, progressive loss of central venous access sites is a potentially fatal complication. We present the case of a 5-year-old girl with parenteral nutrition-dependent short bowel syndrome and no remaining standard central venous access sites despite medical anticoagulation, in whom angioplasty and stent implantations were used to reconstruct chronically occluded central veins. The patient presented with a bloodstream infection necessitating tunneled central venous line removal from the left internal jugular vein. All other standard access sites had known occlusions. The right iliofemoral vein (RIFV) and infrarenal inferior vena cava were recanalized and dilated with high-pressure balloons. The left internal jugular line was removed and a line was placed in the now-patent RIFV for antimicrobial therapy. After treatment, the RIFV line was removed and the vessels were stented open for future access. The occluded left innominate vein was recanalized and dilated to allow a new tunneled line to be placed. At 10 months, the line was functional and uninfected and the RIFV and inferior vena cava stents were patent without in-stent restenosis. We propose a new paradigm that uses these techniques to prevent access site exhaustion in patients who do not respond to anticoagulation therapy. This approach may reduce morbidity and mortality in patients with chronic access needs and the need for intestinal transplantation in patients with intestinal failure.


Assuntos
Angioplastia com Balão , Cateterismo Venoso Central/efeitos adversos , Nutrição Parenteral/métodos , Síndrome do Intestino Curto/terapia , Stents , Trombose Venosa/etiologia , Trombose Venosa/terapia , Pré-Escolar , Feminino , Humanos , Trombose Venosa/diagnóstico por imagem
13.
Cardiol Young ; 28(6): 804-810, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29534778

RESUMO

BACKGROUND: One indication for intervention in coarctation of the aorta is a peak-to-peak gradient >20 mmHg. Gradients may be masked in patients under general anaesthesia and may be higher during exercise. Isoproterenol was given during cardiac catheterisation to simulate a more active physiologic state. OBJECTIVES: We aimed to describe the haemodynamic effects of isoproterenol in patients with coarctation and the impact of intervention on the elicited gradients. METHODS: A retrospective study was performed on two-ventricle patients who underwent cardiac catheterisation for coarctation with isoproterenol testing. RESULTS: 25 patients received isoproterenol before and after intervention. With isoproterenol, the mean diastolic (p=0.0015) and mean arterial (p=0.0065) blood pressures proximal to the coarctation decreased significantly. The mean systolic, diastolic, and mean arterial blood pressures distal to the coarctation decreased significantly (p20 mmHg. Post intervention, the median gradient decreased to 2 (0-29) mmHg, versus baseline, p=0.005, and with isoproterenol it decreased to 8 (0-27) mmHg, versus pre-intervention isoproterenol, p<0.0001. There were significant improvements in the gradients by Doppler (<0.0001) and by blood pressure cuff (p=0.0313). The gradients on isoproterenol best correlated with gradients by blood pressure cuff in the awake state (R2=0.76, p<0.0001). CONCLUSIONS: Isoproterenol can be a useful tool to assess the significance of a coarctation and the effectiveness of an intervention. Percutaneous interventions can effectively reduce the gradients elicited by isoproterenol.


Assuntos
Agonistas Adrenérgicos beta/administração & dosagem , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/fisiopatologia , Cateterismo Cardíaco , Isoproterenol/administração & dosagem , Adolescente , Pressão Arterial/efeitos dos fármacos , Criança , Pré-Escolar , Ecocardiografia Doppler , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Masculino , Contração Miocárdica/efeitos dos fármacos , Estudos Retrospectivos , Adulto Jovem
15.
Am J Cardiol ; 121(2): 262-268, 2018 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-29153244

RESUMO

We sought to describe the acute results and short- to medium-term durability of transcatheter tricuspid valve-in-valve (TVIV) implantation within surgical bioprostheses among patients with Ebstein anomaly (EA). Cases were identified from a voluntary, multicenter, international registry of 29 institutions that perform TVIV. Demographic, clinical, procedural, and follow-up data were analyzed. Eighty-one patients with EA underwent TVIV from 2008 to 2016. Thirty-four patients (42%) were New York Heart Association (NYHA) class 3/4 at time of TVIV. The most common indication for TVIV was the presence of moderate or severe tricuspid regurgitation (40%). Most patients received a Melody valve (64%). TVIV was ultimately successful in all patients, and there was no procedural mortality. Four patients (5%) developed acute valve thrombosis, 4 patients (5%) developed endocarditis, and 9 patients (11%) developed valve dysfunction not related to thrombosis or endocarditis. Eight patients (10%) underwent reintervention (2 transcatheter, 6 surgical) due to thrombosis (3), endocarditis (2), other valve dysfunction (2), and patient-prosthesis mismatch without valve dysfunction (1). Among 69 patients who were alive without reintervention at latest follow-up, 96% of those with NYHA status reported were class 1/2, a significant improvement from baseline (62% NYHA class 1/2, p <0.001). In conclusion, transcatheter TVIV offers a low-risk, minimally invasive alternative to surgical tricuspid valve re-replacement in patients with EA and a failing tricuspid valve bioprosthesis.


Assuntos
Anomalia de Ebstein/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Sistema de Registros , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Adolescente , Adulto , Idoso , Bioprótese , Cateterismo Cardíaco/métodos , Anomalia de Ebstein/complicações , Endocardite/epidemiologia , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Reoperação , Trombose/epidemiologia , Resultado do Tratamento , Insuficiência da Valva Tricúspide/complicações , Adulto Jovem
16.
Pediatr Cardiol ; 39(3): 445-449, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29138879

RESUMO

The aim of this study was to define characteristics of those patients who are referred for device closure of an Atrial septal defect (ASD), but identified to "crossover" surgery. All patients who underwent surgical and device (Amplatzer or Helex occluder) closures of secundum ASDs from 2001 to 2010 were reviewed and organized into three groups: surgical closure, device closure, and "crossover" group. 369 patients underwent ASD closure (265 device, 104 surgical). 42 of the 265 patients referred for device closure "crossed over" to the surgical group at various stages of the catheterization procedure. The device group had defect size measuring 14.2 mm (mean) and an ASD index (Defect Size (mm)/BSA) of 14.0 compared to the corresponding values in the surgical group (20.1 mm, ASD index 25.9) (P < 0.001) and in the "crossover" group (20.7 mm, 22.6 ASD index) (P < 0.001). 79 patients in the device group had a deficient rim, and 86% were located in the retroaortic region. 33 patients in the "crossover" group had deficient rims with 70% deficiency in the posterior/inferior rim. The device group with deficient rims had an ASD index of 14.7 compared with the crossover group ASD index of 23.8 (P < 0.001). Comparing the device and "crossover" groups, an ASD index greater than 23.7 had a 90% specificity in "crossing over" to surgery. The crossover and surgical groups had statistically larger ASD defect size indexes compared with the device group. Deficient rim in the posterior/inferior rim is associated with a large ASD size index which is a predictive factor for crossing over to surgery. Catheterization did not negatively impact surgical results in the "crossover" group.


Assuntos
Cateterismo Cardíaco/métodos , Comunicação Interatrial/cirurgia , Dispositivo para Oclusão Septal/efeitos adversos , Adolescente , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Bases de Dados Factuais , Feminino , Humanos , Masculino , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
17.
Catheter Cardiovasc Interv ; 90(6): 963-971, 2017 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-28862385

RESUMO

BACKGROUND: Unique and small anatomical features often preclude the use of available vascular stents in pediatric patients with congenital heart disease (CHD). OBJECTIVES: To report our experience and outcomes tailoring stents to fit unique anatomy, particularly in small children and infants with CHD. METHODS: Stent tailoring techniques included trimming, folding, and flaring. Patients receiving a tailored stent November 2002 to February 2015 were included in a retrospective analysis. RESULTS: Forty-one tailored stents were implanted in 30 patients with median age and weight of 0.8 years (6 days to 17 years) and 8.1 kg (2.9-47.9 kg). Thirty stents were placed intraoperatively and 11 percutaneously. Sites included branch pulmonary arteries (BPA; n = 32), pulmonary veins (n = 6), SVC (n = 1), and the ventricular septum (n = 2). Twenty-three (56%) stents were trimmed with or without folding to avoid jailing of side branches, 16 (39%) stents were folded or flared with or without trimming to avoid excessive proximal protrusion, and two (5%) stents were folded back at both ends for implantation in ventricular septal defects. Final stent lengths were 6-15 mm. Minimal vessel diameters increased from 2.8 ± 1.4 mm to 6.7 ± 2.6 mm (P < 0.001). Complications included two intraoperative BPA tears, three pinhole balloon leaks, two intraoperative stent dislodgements, one transient heart block, and one lung reperfusion injury. Follow-up catheterization included 36 re-dilations and implantation of four additional stents over a median of 4.1 years. In-stent restenosis was the indication in 25 (69.4%) re-interventions. CONCLUSION: Tailored stents can be safely implanted to fit unique anatomy in small patients. Re-interventions can effectively treat restenosis and accommodate ongoing vessel growth.


Assuntos
Anormalidades Múltiplas/cirurgia , Vasos Sanguíneos/diagnóstico por imagem , Procedimentos Endovasculares/métodos , Cardiopatias Congênitas/cirurgia , Implantação de Prótese/métodos , Stents , Anormalidades Múltiplas/diagnóstico , Adolescente , Criança , Pré-Escolar , Constrição Patológica , Feminino , Cardiopatias Congênitas/diagnóstico , Humanos , Lactente , Recém-Nascido , Masculino , Desenho de Prótese , Estudos Retrospectivos
18.
Pediatr Cardiol ; 38(8): 1583-1591, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28770307

RESUMO

The objective of this study was to compare radiation doses and imaging quality using Philips AlluraClarity (Philips Healthcare, Best, The Netherlands) X-ray system and an older generation reference system. AlluraClarity is a new generation fluoroscopy system designed to reduce radiation without compromising image quality, but reports of its use in pediatric patients are limited. Dose area products (DAP, mGy cm2) and DAP/kg were compared in patients catheterized using Allura Xper and AlluraClarity systems over a year of use for each. Randomly selected studies from each system were assessed for image quality. The 430 patients imaged with Clarity were larger than the 332 imaged with Xper (median BSA: 0.74 vs. 0.64 m2, p = 0.06), and median total fluoroscopic times (TFT) were similar (15.8 vs. 16.1 min, p = 0.37). Median DAPs were 8661 mGy cm2 (IQR: 18,300 mGy cm2) and 4523 mGy cm2 (IQR: 11,596 mGy cm2) with Xper and Clarity, respectively (p < 0.001). There was a reduction in median DAP in all procedure categories. After adjustment for BSA, TFT, and procedure type, using Clarity was associated with a 57.5% (95% CI 51.5-62.8%, p < 0.001) reduction in DAP for all procedures. Reductions did not significantly differ by weight (<10 kg, 10-40 kg, ≥ 40 kg). There was an adjusted percent reduction in DAP for each procedure category ranging from 39.0% (95% CI 25.6-50.1%, p < 0.001) for cardiac biopsies with or without coronary angiography to 67.6% (95% CI 61.2-72.8%, p < 0.001) for device occlusions. Mean overall imaging quality scores (4.3 ± 0.8 with Clarity vs. 4.4 ± 0.6 with Xper, p = 0.62) and scores based on specific quality parameters were similar in the two groups. Use of AlluraClarity substantially reduced radiation doses compared to the older generation reference system without compromising imaging quality in a pediatric cardiac catheterization lab.


Assuntos
Cateterismo Cardíaco/instrumentação , Fluoroscopia/instrumentação , Doses de Radiação , Exposição à Radiação/prevenção & controle , Adolescente , Adulto , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Criança , Pré-Escolar , Angiografia Coronária/instrumentação , Humanos , Lactente , Recém-Nascido , Países Baixos , Fatores de Risco , Adulto Jovem
19.
Cardiol Young ; 26(6): 1187-93, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26593884

RESUMO

OBJECTIVES: The aim of the present study was to determine the outcomes of using the Valeo stent (Bard Peripheral Vascular, Tempe, Arizona, United States of America) in small children with CHD. BACKGROUND: Stenting vascular stenoses is safe and effective in adults and older children with CHD but is limited in smaller children. The design of the Valeo stent addresses these limitations but has not been extensively described. METHODS: Bench testing was conducted to determine the maximum diameter of the stent, foreshortening, and side-cell diameter. A retrospective analysis of Valeo stents implanted between October, 2012 and October, 2014 was performed. Patient profile, pre-implant/post-implant catheterization data, and stent geometry were reviewed. RESULTS: Bench testing: medium and large Valeo stents can be dilated up to 13 mm and 20 mm diameters, respectively. Side-cells are dilatable up to 12 mm. Valeo stents are of low profile - delivered through 6- or 7-Fr sheaths - and show minimal foreshortening. Retrospective analysis: a total of 81 stents were implanted in 61 patients with CHD. The median weight was 15.3 kg, and the median age was 58.9 months. Stents were implanted in the pulmonary artery, systemic vein, aorta, and pulmonary vein. Overall, mean vessel diameters increased from 4.1 to 7.7 mm (121.7%). There was effective mean gradient reduction: 3.7-0.5 mmHg (63%) in the venous systems, 28.2-12.5 mmHg (63.7%) in the pulmonary arteries, and 17.4-4 mmHg (77.1%) in the aorta. The mean stent foreshortening was 2.5%, and the mean recoil was 5.9%. Side-cells that crossed other vessels were dilated in four cases, and stents were re-mounted onto different-sized balloons in seven cases. CONCLUSIONS: The features of the Valeo stent, such as low profile, large maximum diameter, open-cell design, minimal foreshortening, and recoil, make it suitable for treating vascular stenoses in small children with CHD.


Assuntos
Cateterismo/métodos , Cardiopatias Congênitas/cirurgia , Desenho de Prótese/métodos , Stents/normas , Pré-Escolar , Constrição Patológica/cirurgia , Humanos , Lactente , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA