Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Orthop Traumatol ; 24(1): 15, 2023 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-37055638

RESUMO

BACKGROUND: The functional results of total elbow arthroplasty (TEA) are controversial and the medium- to long-term revision rates are relatively high. The aim of the present study was to analyze the stresses of TEA in its classic configuration, identify the areas of greatest stress in the prosthesis-bone-cement interface, and evaluate the most wearing working conditions. MATERIALS AND METHODS: By means of a reverse engineering process and using a 3D laser scanner, CAD (computer-aided drafting) models of a constrained elbow prosthesis were acquired. These CAD models were developed and their elastic properties, resistance, and stresses were studied through finite element analysis (finite element method-FEM). The obtained 3D elbow-prosthesis model was then evaluated in cyclic flexion-extension movements (> 10 million cycles). We highlighted the configuration of the angle at which the highest stresses and the areas most at risk of implant mobilization develop. Finally, we performed a quantitative study of the stress state after varying the positioning of the stem of the ulnar component in the sagittal plane by ± 3°. RESULTS: The greatest von Mises stress state in the bone component for the 90° working configuration was 3.1635 MPa, which occurred in the most proximal portion of the humeral blade and in the proximal middle third of the shaft. At the ulnar level, peaks of 4.1763 MPa were recorded at the proximal coronoid/metaepiphysis level. The minimum elastic resistance and therefore the greatest stress states were recorded in the bone region at the apex of the ulnar stem (0.001967 MPa). The results of the analysis for the working configurations at 0° and 145° showed significant reductions in the stress states for both prosthetic components; similarly, varying the positioning of the ulnar component at 90° (- 3° in the sagittal plane, 0° in the frontal plane) resulted in better working conditions with a greater resulting developed force and a lower stress peak in the ulnar cement. CONCLUSION: The areas of greatest stress occur in specific regions of the ulnar and humeral components at the bone-cement-prosthesis interface. The heaviest configuration in terms of stresses was when the elbow was flexed at 90°. Variations in the positioning in the sagittal plane can mechanically affect the movement, possibly resulting in longer survival of the implant.


Assuntos
Prótese de Cotovelo , Humanos , Análise de Elementos Finitos , Úmero , Ulna , Cimentos Ósseos
2.
Bioengineering (Basel) ; 9(8)2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-36004933

RESUMO

The spine is the load-bearing structure of human beings and may present several disorders, with low back pain the most frequent problem during human life. Signs of a spine disorder or disease vary depending on the location and type of the spine condition. Therefore, we aim to develop a probabilistic atlas of the lumbar spine segment using statistical shape modeling (SSM) and then explore the variability of spine geometry using principal component analysis (PCA). Using computed tomography (CT), the human spine was reconstructed for 24 patients with spine disorders and then the mean shape was deformed upon specific boundaries (e.g., by ±3 or ±1.5 standard deviation). Results demonstrated that principal shape modes are associated with specific morphological features of the spine segment such as Cobb's angle, lordosis degree, spine width and height. The lumbar spine atlas here developed has evinced the potential of SSM to investigate the association between shape and morphological parameters, with the goal of developing new treatments for the management of patients with spine disorders.

3.
Comput Methods Programs Biomed ; 221: 106875, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35588661

RESUMO

BACKGROUND AND OBJECTIVE: In orthopedic medical devices, elasto-plastic behavior differences between bone and metallic materials could lead to mechanical issues at the bone-implant interface, as stress shielding. Those issue are mainly related to knee and hip arthroplasty, and they could be responsible for implant failure. To reduce mismatching-related adverse events between bone and prosthesis mechanical properties, modifying the implant's internal geometry varying the bulk stiffness and density could be the right approach. Therefore, this feasibility study aims to assess which in-body gap geometry improves, by reducing, the bulk stiffness. METHODS: Using five finite element models, a uniaxial compression test in five cubes with a 20 mm thickness was simulated and analyzed. The displacements, strain and Young Modulus were calculated in four cubes, each containing internal prismatic gaps with different transversal sections (squared, hexagonal, octagonal, and circular). Those were compared with a fifth full-volume cube used as control. RESULTS: The most significant difference have been achieved in displacement values, in cubes containing internal gaps with hexagonal and circular transversal sections (82 µm and 82.5 µm, respectively), when compared to the full-volume cube (69.3 µm). CONCLUSIONS: This study suggests that hexagonal and circular shape of the gaps allows obtaining the lower rigidity in a size range of 4 mm, offering a starting approach to achieve a "close-to-bone" material, with a potential use in prosthetic devices with limited thickness.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Módulo de Elasticidade , Estudos de Viabilidade , Análise de Elementos Finitos , Estresse Mecânico
4.
J Exp Orthop ; 8(1): 50, 2021 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-34245384

RESUMO

PURPOSE: The study aims were to assess the kinematic data, Internal-External (IE) rotation, and Antero-Posterior (AP) translation of the contact points between the femoral condyles and polyethylene insert and to develop a combined dynamic RSA-FE (Radiostereometric - Finite Element) model that gives results congruent with the literature. METHODS: A cohort of 15 patients who underwent cemented cruciate-retaining highly congruent mobile-bearing total knee arthroplasty were analyzed during a sit-to-stand motor task. The kinematical data from Dynamic RSA were used as input for a patient-specific FE model to calculate condylar contact points between the femoral component and polyethylene insert. RESULTS: The femoral component showed an overall range about 4 mm of AP translation during the whole motor task, and the majority of the movement was after 40° of flexion. Concerning the IE rotation, the femoral component started from an externally rotate position (- 6.7 ± 10°) at 80° of flexion and performed an internal rotation during the entire motor task. The overall range of the IE rotation was 8.2°. CONCLUSIONS: During the sit to stand, a slight anterior translation from 40° to 0° of flexion of the femoral component with respect to polyethylene insert, which could represent a paradoxical anterior translation. Despite a paradoxical anterior femoral translation was detected, the implants were found to be stable. Dynamic RSA and FE combined technique could provide information about prosthetic component's stress and strain distribution and the influence of the different designs during the movement.

5.
Bioengineering (Basel) ; 8(5)2021 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-34068270

RESUMO

The left ventricle (LV) constantly changes its shape and function as a response to pathological conditions, and this process is known as remodeling. In the presence of aortic stenosis (AS), the degenerative process is not limited to the aortic valve but also involves the remodeling of LV. Statistical shape analysis (SSA) offers a powerful tool for the visualization and quantification of the geometrical and functional patterns of any anatomic changes. In this paper, a SSA method was developed to determine shape descriptors of the LV under different degrees of AS and thus to shed light on the mechanistic link between shape and function. A total of n=86 patients underwent computed tomography (CT) for the evaluation of valvulopathy were segmented to obtain the LV surface and then were automatically aligned to a reference template by rigid registrations and transformations. Shape modes of the anatomical LV variation induced by the degree of AS were assessed by principal component analysis (PCA). The first shape mode represented nearly 50% of the total variance of LV shape in our patient population and was mainly associated to a spherical LV geometry. At Pearson's analysis, the first shape mode was positively correlated to both the end-diastolic volume (p<0.01, R=0.814) and end-systolic volume (p<0.01, and R=0.922), suggesting LV impairment in patients with severe AS. A predictive model built with PCA-related shape modes achieved better performance in stratifying the occurrence of adverse events with respect to a baseline model using clinical demographic data as risk predictors. This study demonstrated the potential of SSA approaches to detect the association of complex 3D shape features with functional LV parameters.

6.
Comput Methods Programs Biomed ; 204: 106072, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33819822

RESUMO

BACKGROUND AND OBJECTIVE: The aim of the present study was to review the literature concerning the analysis of periprosthetic bone remodeling through finite element (FE) simulation. METHODS: A systematic review was conducted on 9 databases, taking into account a ten-year time period (from 2009 until 2020). The inclusion criteria were: articles published in English, publication date after 2009, full text articles, articles containing the keywords both in the abstract and in the title. The articles were classified through the following parameters: dimensionality of the simulation, modelling of the bone-prosthesis interface, output parameters, type of simulated prosthesis, bone remodeling algorithm. RESULTS: Sixty-seven articles were included in the study. Femur and tooth were the most evaluated bone segment (respectively 41.8% and 29.9%). The 55.2% of the evaluated articles used a bonded bone-prosthesis interface, 73% used 3D simulations, 67.2% of the articles (45 articles) evaluate the bone remodeling by the bone density variation. At last, 59.7% of the articles employed algorithms based on a specific remodeling function. CONCLUSIONS: Increasing interest in the bone remodeling FE analysis in different bone segments emerged from the review, and heterogeneous solutions were adopted. An optimal balance between computational cost and accuracy is needed to accurately simulate the bone remodeling phenomenon in the post-operative period.


Assuntos
Remodelação Óssea , Fêmur , Densidade Óssea , Simulação por Computador , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Análise de Elementos Finitos , Modelos Biológicos
7.
Injury ; 50 Suppl 2: S18-S23, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30739762

RESUMO

PURPOSE: Massive rotator cuff tears are common in the aging population. The incidence of failed rotator cuff repairs is still quite high, especially in the treatment of full-thickness tears or revision repairs. In this context, natural and synthetic meshes can be used as augmentation scaffolds or as devices to close the gap between a retracted tendon and the bone. The purpose of this work is to evaluate the ultimate tensile strength of different tendon-patch joints in order to consider their use in the treatment of massive cuff tears. MATERIALS AND METHODS: Porcine tendons and a synthetic low-density polypropylene mesh have been used. A preliminary study on the tensile strength of tendons and patches has been performed. Different patch-tendon joints have been studied by modifying the number and the layout of the sutures. For every joint, the tensile test, performed through an electromechanical machine, has been repeated at least twice to obtain reliable data. RESULTS: Experimental tensile tests on tendons and patches have given good results with very low dispersion data. Mean values of the calculated ultimate tensile stresses are, respectively, about 34 MPa and 16 MPa for tendons and patches. As regards the sutures arrangement, the staggered layout gave, for all joints, a higher tensile strength than the regular (aligned) one. Different ultimate tensile stress values, depending on the sutures number and layout, have been calculated for the joints. CONCLUSION: Synthetic patches could be an interesting option to repair massive cuff tears and to improve, in a significant way, pain, range of motion and strength at time 0, so reducing the rehabilitation time. Obtained results demonstrated that joints with a suitable number and layout of sutures could ensure very good mechanical performances. The failure load of the tendon-patch joint, in fact, is higher than the working load on a healthy tendon.


Assuntos
Lesões do Manguito Rotador/patologia , Manguito Rotador/patologia , Suturas , Tendões/transplante , Resistência à Tração/fisiologia , Animais , Materiais Biocompatíveis , Modelos Animais , Amplitude de Movimento Articular/fisiologia , Procedimentos de Cirurgia Plástica , Técnicas de Sutura , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA