1.
Phys Med Biol ; 69(16)2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-38996425

RESUMO

Objective.This study explores the feasibility of a stationary gantry cardiac gated computed tomography (CT) with carbon nanotube (CNT) linear x-ray source arrays.Approach.We developed a stationary gantry CT system utilizing multipixel CNT x-ray sources. Given the advantages of straightforward x-ray pulse control with these sources, we investigated the potential for gated prospective imaging. We implemented prospective respiratory and cardiac gating control and evaluated the system through dynamic phantom imaging studies followed by imaging of a porcine model.Main Results.The findings revealed minimal anatomical motion artifacts in the heart and lungs, confirming successful physiologic gated acquisition in stationary gantry cardiac CT. This indicates the potential of this imaging approach for reducing artifacts and improving image quality.Significance.This study demonstrates the feasibility of prospective physiological gating with CNT x-ray sources in a stationary gantry setup for cardiac imaging. This approach could potentially alleviate the need for beta blocker administration during cardiac CT scans, thereby increasing the flexibility of the imaging system and enabling the imaging of a wider variety of patient cardiac conditions.


Assuntos
Coração , Nanotubos de Carbono , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Animais , Suínos , Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação , Técnicas de Imagem de Sincronização Cardíaca/métodos , Estudos Prospectivos , Estudos de Viabilidade , Artefatos
2.
Sci Rep ; 14(1): 9886, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38688995

RESUMO

Dual-energy cone beam computed tomography (DE-CBCT) has been shown to provide more information and improve performance compared to a conventional single energy spectrum CBCT. Here we report a low-cost DE-CBCT by spectral filtration of a carbon nanotube x-ray source array. The x-ray photons from two focal spots were filtered respectively by a low and a high energy filter. Projection images were collected by alternatively activating the two beams while the source array and detector rotated around the object, and were processed by a one-step materials decomposition and reconstruction method. The performance of the DE-CBCT scanner was evaluated by imaging a water-equivalent plastic phantom with inserts containing known densities of calcium or iodine and an anthropomorphic head phantom with dental implants. A mean energy separation of 15.5 keV was achieved at acceptable dose rates and imaging time. Accurate materials quantification was obtained by materials decomposition. Metal artifacts were reduced in the virtual monoenergetic images synthesized at high energies. The results demonstrated the feasibility of high quality DE-CBCT imaging by spectral filtration without using either an energy sensitive detector or rapid high voltage switching.

3.
Phys Med Biol ; 69(7)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38471174

RESUMO

Cone beam computed tomography (CBCT) is known to suffer from strong scatter and cone beam artifacts. The purpose of this study is to develop and characterize a rapidly scanning carbon nanotube (CNT) field emission x-ray source array to enable a multisource CBCT (ms-CBCT) image acquisition scheme which has been demonstrated to overcome these limitations. A CNT x-ray source array with eight evenly spaced focal spots was designed and fabricated for a medium field of view ms-CBCT for maxillofacial imaging. An external multisource collimator was used to confine the radiation from each focal spot to a narrow cone angle. For ms-CBCT imaging, the array was placed in the axial direction and rapidly scanned while rotating continuously around the object with a flat panel detector. The x-ray beam profile, temporal and spatial resolutions, energy and dose rate were characterized and evaluated for maxillofacial imaging. The CNT x-ray source array achieved a consistent focal spot size of 1.10 ± 0.04 mm × 0.84 ± 0.03 mm and individual beam cone angle of 2.4°±0.08 after collimation. The x-ray beams were rapidly switched with a rising and damping times of 0.21 ms and 0.19 ms, respectively. Under the designed operating condition of 110 kVp and 15 mA, a dose rate of 8245µGy s-1was obtained at the detector surface with the inherent Al filtration and 2312µGy s-1with an additional 0.3 mm Cu filter. There was negligible change of the x-ray dose rate over many operating cycles. A ms-CBCT scan of an adult head phantom was completed in 14.4 s total exposure time for the imaging dose in the range of that of a clinical CBCT scanner. A spatially distributed CNT x-ray source array was designed and fabricated. It has enabled a new multisource CBCT to overcome some of the main inherent limitations of the conventional CBCT.


Assuntos
Nanotubos de Carbono , Raios X , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
4.
Sci Rep ; 14(1): 3887, 2024 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-38366012

RESUMO

Multisource cone beam computed tomography CBCT (ms-CBCT) has been shown to overcome some of the inherent limitations of a conventional CBCT. The purpose of this study was to evaluate the accuracy of ms-CBCT for measuring the bone mineral density (BMD) of mandible and maxilla compared to the conventional CBCT. The values measured from a multi-detector CT (MDCT) were used as substitutes for the ground truth. An anthropomorphic adult skull and tissue equivalent head phantom and a homemade calibration phantom containing inserts with varying densities of calcium hydroxyapatite were imaged using the ms-CBCT, the ms-CBCT operating in the conventional single source CBCT mode, and two clinical CBCT scanners at similar imaging doses; and a clinical MDCT. The images of the anthropomorphic head phantom were reconstructed and registered, and the cortical and cancellous bones of the mandible and the maxilla were segmented. The measured CT Hounsfield Unit (HU) and Greyscale Value (GV) at multiple region-of-interests were converted to the BMD using scanner-specific calibration functions. The results from the various CBCT scanners were compared to that from the MDCT. Statistical analysis showed a significant improvement in the agreement between the ms-CBCT and MDCT compared to that between the CBCT and MDCT.


Assuntos
Densidade Óssea , Tomografia Computadorizada de Feixe Cônico Espiral , Cabeça , Crânio , Tomografia Computadorizada de Feixe Cônico/métodos , Imagens de Fantasmas
5.
Commun Eng ; 2(1)2023.
Artigo em Inglês | MEDLINE | ID: mdl-38549919

RESUMO

Cone beam computed tomography (CBCT) is widely used in medical and dental imaging. Compared to a multidetector CT, it provides volumetric images with high isotropic resolution at a reduced radiation dose, cost and footprint without the need for patient translation. The current CBCT has several intrinsic limitations including reduced soft tissue contrast, inaccurate quantification of X-ray attenuation, image distortions and artefacts, which have limited its clinical applications primarily to imaging hard tissues and made quantitative analysis challenging. Here we report a multisource CBCT (ms-CBCT) which overcomes the short-comings of the conventional CBCT by using multiple narrowly collimated and rapidly scanning X-ray beams from a carbon nanotube field emission source array. Phantom imaging studies show that, the ms-CBCT increases the accuracy of the Hounsfield unit values by 60%, eliminates the cone beam artefacts, extends the axial coverage, and improves the soft tissue contrast-to-noise ratio by 30-50%, compared to the CBCT configuration.