Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38402485

RESUMO

OBJECTIVES: Aortic valve repair requires the creation of a normal geometry of cusps and aortic root. Of the different dimensions, geometric cusp height is the most difficult to change while annular and sinotubular dimensions can be easily modified. The objective of this study was to investigate, by computer simulation, ideal combinations of annular and sinotubular junction size for a given geometric height. METHODS: Based on a literature review of anatomical data, a computational biomechanics model was generated for a tricuspid aortic valve. We aimed to determine the ideal relationships for the root dimensions, keeping geometric height constant and creating different combinations of the annular and sinotubular junction dimensions. Using this model, 125 virtual anatomies were created, with 25 different combinations of annulus and sinotubular junction. Effective height, coaptation height and mechanical cusp stress were calculated with the valves in closed configuration. RESULTS: Generally, within the analysed range of geometric heights, changes to the annular diameter yielded a stronger impact than sinotubular junction diameter changes for optimal valve configuration. The best results were obtained with the sinotubular junction being 2-4 mm larger than the annulus, leading to higher effective height, normal coaptation height and lower stress. Within the range tested, stenosis did not occur due to annular reduction. CONCLUSIONS: In tricuspid aortic valves, the geometric height can be used to predict ideal post-repair annular and sinotubular junction dimensions for optimal valve configuration. Such an ideal configuration is associated with reduced cusp stress.

2.
J Cardiovasc Med (Hagerstown) ; 25(3): 210-217, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38251434

RESUMO

AIMS: Septal myectomy is the treatment of choice for hypertrophic obstructive cardiomyopathy (HOCM). Around 30-60% of patients with HOCM have a secondary mitral valve regurgitation due to systolic anterior motion (SAM). We report our experience with extended septal myectomy and its impact on the incidence of concomitant mitral valve procedures. METHODS: This is a retrospective study on 84 patients who underwent SM from January 2008 to February 2022. Surgical procedure was performed according to the concept of 'extended myectomy' described by Messmer in 1994. Follow-up outcomes in terms of survival, hospital admissions for heart failure or MV disease, cardiac reoperations, and pacemaker (PMK) implantation were recorded. RESULTS: Mean age was 61 ±â€Š15 years. Mitral valve surgery was performed in seven cases (8%); particularly only one patient without degenerative mitral valve disease underwent mitral valve surgery, with a plicature of the posterior leaflet. In-hospital mortality was 5%. Mitral valve regurgitation greater than mild was present in four patients (5%) at discharge. Twelve-year survival was 78 ±â€Š22%. Cumulative incidence of rehospitalization for heart failure and rehospitalization for mitral valve disease was 10 ±â€Š4 and 2.5 ±â€Š2.5%, respectively. PMK implantation was 5% at discharge, with a cumulative incidence of 15 ±â€Š7%. Freedom from cardiac reoperations was 100%. CONCLUSION: Septal myectomy for HOCM is associated with good outcomes. Although concomitant surgery on the mitral valve to address SAM and associated regurgitation has been advocated, these procedures were needed in our practice only in patients with intrinsic mitral valve disease. Adequate myectomy addresses the underlying pathophysiology in most patients.


Assuntos
Cardiomiopatia Hipertrófica , Insuficiência Cardíaca , Doenças das Valvas Cardíacas , Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Idoso , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Doenças das Valvas Cardíacas/complicações , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/cirurgia , Cardiomiopatia Hipertrófica/complicações , Insuficiência Cardíaca/complicações
3.
Front Surg ; 10: 1302976, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38074286

RESUMO

Background: Temporary intravascular shunts (TIVS) may allow quick revascularization and distal reperfusion, reducing the ischemic time (IT) when an arterial injury occurs. Furthermore, TIVS temporarily restore peripheral perfusion during the treatment of concomitant life-threatening injuries or when patients require evacuation to a higher level of care. Notwithstanding, there are still disputes regarding the use of TIVS, in view of the paucity of evidence in terms of potential benefits and with regard to the anticoagulation during the procedure. The present study aimed to assess TIVS impact, safety, and timing on limb salvage in complex civilian vascular traumas. Patients and methods: Data were retrieved from the prospective database of our department, which included all patients hospitalized with a vascular injury of the extremities between January 2006 and December 2022. Patients undergoing TIVS during vascular injury management were included in group A, and those who could not postpone immediate care for TIVS insertion were included in group B (control group). Data concerning the times required for extremity revascularization or other surgical procedures such as orthopedic interventions and the time of limb ischemia were compared between the two groups. A comparison of the postoperative course between the two groups was also performed. Results: A total of 53 patients were included: group A (TIVS insertion, n = 31) and group B (control, n = 22). Revascularization time significantly differed (p = 0.002) between the two groups, which is lower in group A (4.17 ± 2.37 h vs. 5.81 ± 1.26 h). TIVS positively affected the probability of limb salvage (p = 0.02). At multivariate analysis, the factors independently associated with limb salvage were TIVS usage, the necessity of hyperbaric oxygen therapy, and the total IT. In group A, there were three deaths and one major amputation, and in group B, there were two deaths and four major amputations. Conclusions: The use of TIVS minimizes revascularization time and improves limb salvage probability. A multidisciplinary approach is recommended, and correct surgical timing is key to ensure the best outcome.

4.
J Clin Med ; 12(21)2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37959183

RESUMO

INTRODUCTION: The most common minimally invasive approach for aortic valve replacement (AVR) is the partial upper mini-sternotomy. The aim of this study is to understand which preoperative computed tomography (CT) features are predictive of longer operations in terms of cardio-pulmonary bypass timesand cross-clamp times. METHODS: From 2011 to 2022, we retrospectively selected 246 patients which underwent isolated AVR and had a preoperative ECG-gated CT scan. On these patients, we analysed the baseline anthropometric characteristics and the following CT scan parameters: aortic annular dimensions, valve calcium score, ascending aorta length, ascending aorta inclination and aorta-sternum distance. RESULTS: We identified augmented body surface area (>1.9 m2), augmented annular diameter (>23 mm), high calcium score (>2500 Agatson score) and increased aorta-sternum distance (>30 mm) as independent predictors of elongated operation times (more than two-fold). CONCLUSIONS: Identifying the preoperative predictive factors of longer operations can help surgeons select cases suitable for minimally invasive approaches, especially in a teaching context.

5.
Biomedicines ; 11(10)2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37893238

RESUMO

Epigenetic modifications play a fundamental role in the progression of coronary artery disease (CAD). This panoramic review aims to provide an overview of the current understanding of the epigenetic mechanisms involved in CAD pathogenesis and highlights the potential implications for personalized medicine approaches. Epigenetics is the study of heritable changes that do not influence alterations in the DNA sequence of the genome. It has been shown that epigenetic processes, including DNA/histone methylation, acetylation, and phosphorylation, play an important role. Additionally, miRNAs, lncRNAs, and circRNAs are also involved in epigenetics, regulating gene expression patterns in response to various environmental factors and lifestyle choices. In the context of CAD, epigenetic alterations contribute to the dysregulation of genes involved in inflammation, oxidative stress, lipid metabolism, and vascular function. These epigenetic changes can occur during early developmental stages and persist throughout life, predisposing individuals to an increased risk of CAD. Furthermore, in recent years, the concept of personalized medicine has gained significant attention. Personalized medicine aims to tailor medical interventions based on an individual's unique genetic, epigenetic, environmental, and lifestyle factors. In the context of CAD, understanding the interplay between genetic variants and epigenetic modifications holds promise for the development of more precise diagnostic tools, risk stratification models, and targeted therapies. This review summarizes the current knowledge of epigenetic mechanisms in CAD and discusses the fundamental principles of personalized medicine.

6.
Surg Technol Int ; 422023 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-37466920

RESUMO

Aortic annuloplasty has been clearly demonstrated to have a protective influence in aortic valve repair. Over the past 20 years, different annuloplasty concepts have been proposed by different groups. However, the most appropriate approach to enable long-term annular stability remains highly controversial. The aim of this article is to give a general overview of all types of aortic annuloplasty, particularly focusing on the use of an external Teflon ring, as proposed by our group. In this technique, external root dissection is performed in the same fashion as for reimplantation; the only difference is that it is necessary to go below the coronary ostia take-off. A series of pledgeted sutures (usually between 6 and 9 sutures) are placed at the level of the virtual basal ring. The external ring is made using a Teflon strip with a length of 8 to 9 cm, to reduce the annulus to a diameter of between 21 and 23 mm. The sub-annular sutures are then passed at the appropriate level through the Teflon strip and the strip is parachuted outside the aortic root base, passing under the coronary ostia. The two ends of the Teflon strip are tied at the level of the non-coronary sinus. Aortic annuloplasty is a crucial step to improve valve competence and stabilization. While several techniques offer good mid- to long-term results, annuloplasty with an external Teflon ring appears to be a simple and effective alternative to guarantee stable root diameters. Longer follow-up studies are needed to confirm the mid- to long-term results.

8.
J Thorac Cardiovasc Surg ; 165(4): 1335-1342.e2, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-33985805

RESUMO

OBJECTIVE: During the last decade, special concerns have been raised about the anatomic relationships among the sinotubular junction, ventricular-aortic junction, and virtual basal ring to improve the results of root reconstruction. The aim of this study is to evaluate the in vivo anatomy of the aortic root after reimplantation with the Valsalva graft and the anatomic relationship between its components. METHODS: We analyzed 10 consecutive patients with tricuspid aortic valves who underwent reimplantation with the Valsalva graft between September and December 2019. Surgical clips were applied as markers at the level of proximal annular knots and at the distal reimplanted commissures on the neo-sinotubular junction. Electrocardiogram-gated computed tomography scan of the aortic root was performed. Coordinates of the markers were exported on a 3-dimensional modeling software, and the distances between the virtual basal ring and the Dacron graft basal landmarks were measured. RESULTS: The mean heights of Dacron graft basal landmarks from virtual basal ring were right-left commissure 7.1 ± 5.1 mm; right sinus 4.7 ± 4.1 mm; right-noncoronary commissure 2.8 ± 2.2 mm; noncoronary sinus 1.4 ± 1.6 mm; left-noncoronary commissure 2.2 ± 2.3 mm; and left sinus 2.0 ± 0.9 mm. The mean planar distances of basal Dacron graft landmarks from virtual basal ring (thickness) were right-left commissure 5.3 ± 3.1 mm; right sinus 2.8 ± 1.4 mm; right-noncoronary commissure 2.2 ± 1.5 mm; noncoronary sinus 1.5 ± 1.5 mm; left-noncoronary commissure 1.3 ± 1.0 mm; and left sinus 3.4 ± 2.5 mm. CONCLUSIONS: After reimplantation, despite a complete dissection of the root, slight asymmetry of graft proximal seating exists. The inner annuloplasty is on the virtual basal ring, and the proximal edge of the Dacron graft is on the ventricular-aortic junction at a slightly different thickness and height along the annular circumference. At the level of the right sinus and left/right commissure, the Dacron graft is higher than the virtual basal ring and the relative wall thickness is increased. The annular stabilization is unaffected.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/anatomia & histologia , Aorta Torácica , Polietilenotereftalatos , Aorta/diagnóstico por imagem , Aorta/cirurgia , Reimplante , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia
9.
Eur J Cardiothorac Surg ; 63(3)2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36579861

RESUMO

OBJECTIVES: Over the past 20 years, valve-sparing aortic root replacement has aroused increasing interest because of a progressive attitude towards the preservation of natural tissue. Aortic reimplantation is the most used technique to spare the valve, allowing simultaneously aortic root replacement and aortic annular stabilization. The reimplantation into a graft with sinuses guarantees an optimal anatomic and functional reconstruction with established good results at 15 years. The aim of this study is to report the world longest follow-up (up to 20 years) of aortic valve reimplantation using the Valsalva graft. METHODS: From February 2000 to December 2021, 265 consecutive patients with aortic root aneurysm received aortic valve reimplantation using the Valsalva graft. From 2018, leaflet plication with the routine use of calliper was performed. For each patient, we performed both intraoperative and post-procedural transoesophageal echocardiography. All patients were followed with clinical assessment and echocardiography. The mean duration of follow-up was 85 ± 63 months. RESULTS: The study cohort had a median age of 55 ± 18 and 87.2% were male. The aortic root aneurysm was associated to bicuspid aortic valve in 18.9% of patients and to Marfan syndrome in 10.6% of cases. 55.9% had an aortic regurgitation ≥ 2+. Overall survival at 15 was 87.6 ± 3.4. Freedom from cardiac death was stable at 99.6 ± 0.4 at 5, 10 and 15 years. Freedom from recurrent AR ≥3+ and freedom from reoperation remained stable at 10 and 15 years at 92.2 ± 2.1 and 95.9 ± 1.6, respectively. There was a minimal incidence of infective endocarditis (0.8%), thromboembolism (2.2%) and haemorrhage (2.0%). Six out of 7 patients requiring reoperation had surgery in the first period of our experience (last in 2004). Early suboptimal results had a negative effect on residual aortic regurgitation. Moreover, we hypothesized that the routine use of calliper may have contributed to a further improvement of the outcome, even if these data need to be confirmed by a longer follow-up. CONCLUSIONS: The first long-term follow-up after aortic valve reimplantation using the Valsalva graft demonstrated excellent results. These long-term results gradually improved with learning curve, remaining stable during the second decade of observation. The systematic use of calliper may have contributed to a further improvement of the outcome.


Assuntos
Aneurisma da Aorta Torácica , Insuficiência da Valva Aórtica , Implante de Prótese Vascular , Humanos , Masculino , Feminino , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Resultado do Tratamento , Aneurisma da Aorta Torácica/cirurgia , Reoperação/efeitos adversos , Reimplante/métodos
10.
Eur J Cardiothorac Surg ; 63(1)2022 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-36548399

RESUMO

OBJECTIVES: Diffuse myxomatous mitral valve degeneration (DMD) represents a challenge in the reparative mitral valve surgery. A subgroup of patients with symmetrical DMD can be effectively treated with a simple band-annuloplasty with good early and mid-term results. Here, we evaluate the long-term outcomes in terms of freedom from reoperation, recurrence of moderate or severe mitral regurgitation (MR) and overall survival. METHODS: Between April 2006 and December 2020, patients with DMD causing severe MR and the echocardiographic features of symmetrical bileaflet prolapse, central regurgitant jet(s), annular dilation and no chordal ruptures were treated using a simple annuloplasty with a semi-rigid band. These patients were prospectively collected and retrospectively analysed. RESULTS: Seventy-five patients were enrolled. The mean clinical follow-up time was 104 [standard deviation (SD): 43] months, and echocardiographic follow-up time was 95 (SD: 43) months. The mean age was 54 (SD: 15) years, and 56% were females. Long-term overall survival was 98.2% [standard error (SE): 1.8], 93.7% (SE: 4.7) and 93.7% (SE: 4.7) at 4, 8 and 12 years, respectively. The freedom from reoperation was 100% at 4 and 8 years and 94.1% (SE: 5.7) at 12 years. The freedom from recurrent moderate or severe MR was 98.3% (SE: 1.7), 98.3% (SE: 1.7) and 92.8% (SE: 5.5) at 4, 8 and 12 years, respectively. CONCLUSIONS: Mitral repair with the simple band-annuloplasty for the treatment of MR due to symmetrical DMD seems to be stable and effective in the long term.


Assuntos
Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Feminino , Humanos , Pessoa de Meia-Idade , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Seguimentos , Estudos Retrospectivos , Resultado do Tratamento , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Prolapso da Valva Mitral/complicações , Insuficiência da Valva Mitral/etiologia , Reoperação/efeitos adversos , Anuloplastia da Valva Mitral/efeitos adversos
11.
JTCVS Tech ; 15: 36-45, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36276689

RESUMO

Objective: Bicuspid aortic valve repair can be achieved with the reimplantation technique or external ring annuloplasty. Reimplantation could be an "overtreatment" in nonaneurysmatic aortic roots. External ring repair, on the contrary, could be an "undertreatment" in dilated roots. The aim of this retrospective study is to compare the 2 techniques in patients with borderline aortic root dimensions, analyzing early results, aortic regurgitation recurrence, and root dilation over time. Methods: We selected patients with bicuspid aortic valve and ectasia of the aortic root (40-48 mm) who underwent reimplantation or external ring repair. We compared the 2 techniques, analyzing immediate postoperative and follow-up echocardiography. Only patients with at least 1 year of follow-up were included. Results: We obtained 2 groups of 21 patients (reimplantation) and 22 patients (external ring). Median follow-up time was 36 (40) months. There were no deaths during the follow-up periods. Three patients required reoperation in the external ring group because of recurrent aortic regurgitation, with a freedom from reoperation of 77.8% at 7 years (no reoperation was required in the reimplantation group). In the external ring group, we observed an immediate postoperative root diameter reduction and no significative expansion during follow-up (+0.4 mm/year, P = .184). Conclusions: Excellent results of reimplantation technique are confirmed and stable over time. Root diameter seems to remain stable over time when external ring technique was performed. The greater incidence of reoperation after external ring could be due to the progressive learning curve (256 patients vs 52 patients). Longer follow-up studies are needed.

12.
J Card Surg ; 37(5): 1413-1415, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35152492

RESUMO

We report an unusual case of black discoloration of an aortic root aneurysm and aortic valve cusps due to homogentisic acid deposition in a patient suffering from alkaptonuria. The patient underwent a valve-sparing aortic root replacement after careful and objective evaluation of the valve cusps. Despite alkaptonuria is classically associated with aortic valve stenosis and replacement, in the present case, the affected valve cusps were suitable for repair. To our knowledge, this is the first reported case of aortic valve-sparing procedure performed in a patient with alkaptonuria.


Assuntos
Alcaptonúria , Aneurisma da Aorta Torácica , Estenose da Valva Aórtica , Alcaptonúria/complicações , Aorta , Aneurisma da Aorta Torácica/complicações , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Humanos
13.
Semin Thorac Cardiovasc Surg ; 34(3): 844-851, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34216751

RESUMO

Aortic annuloplasty has demonstrated to be a protective factor in valve-sparing root replacement and aortic valve repair. Both reimplantation for aortic root aneurysms and external ring annuloplasty for isolated aortic regurgitation have demonstrated good long-term results. The aim of this anatomical study is to compare aortic reimplantation with Valsalva graft with aortic external ring annuloplasty in bicuspid aortic valves, analyzing their morphological features with CT scan. We selected 56 patients with bicuspid aortic valve who underwent reimplantation procedure with Valsalva graft or external ring annuloplasty; after propensity-matching, 2 homogeneous groups of 10 patients each were obtained. Through multiplanar ECG-gated CT-Scan reconstructions, pre- and postoperative, aortic annular, and valve geometrical characteristics were compared (diameters, perimeter, area and ellipticity index for the annulus; effective height, coaptation length and commissural height for the valve). Aortic root volume was also analyzed. Postoperative comparison of the two groups showed similar geometric features of the aortic annulus in terms of major and minor diameters, perimeter, area and ellipticity index. Analysis of valve's parameters showed similar results in terms of effective height and coaptation length (respectively 10.9 ± 2.1 mm and 7.5 ± 1.9 mm in External Ring group and 10.1 ± 2.0 mm and 7.6 ± 1.6 mm in the Reimplantation group). Both techniques achieve an efficient annuloplasty with similar anatomical results on bicuspid the aortic valves. The stability of these results needs to be confirmed by long-term clinical and echocardiographic follow-up.


Assuntos
Insuficiência da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Anuloplastia da Valva Cardíaca , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/efeitos adversos , Humanos , Reimplante , Resultado do Tratamento
14.
JACC Basic Transl Sci ; 6(9-10): 719-730, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34754985

RESUMO

Thoracic aortic aneurysms (TAA) pathogenesis and progression include many mechanisms. The authors investigated the role of autophagy, oxidative stress, and endothelial dysfunction in 36 TAA patients and 23 control patients. Univariable and multivariable analyses were performed. TAA patients displayed higher oxidative stress and endothelial dysfunction then control patients. Autophagy in the TAA group was reduced. The association of oxidative stress and autophagy with aortic disease supports the role of these processes in TAA. The authors demonstrate a putative role of Nox2 and autophagy dysregulation in human TAA. These findings could pinpoint novel treatment targets to prevent or limit TAA progression.

15.
Ann Thorac Surg ; 112(4): e303-e305, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33689742

RESUMO

This report discusses the case of a patient with an aortic root aneurysm who had previously undergone aortic valve replacement with a large mechanical prosthesis that proved to be normally functioning at the time of reoperation. This report describes a technique of replacing the aortic root while retaining the existing aortic valve, similar to the completion Bentall procedure, using a 32-mm Valsalva graft by suturing the skirted portion of the graft to the sewing ring of the mechanical valve. The ability of the skirt to increase its diameter is the key to this approach.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Valvopatia Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Próteses Valvulares Cardíacas , Aneurisma da Aorta Torácica/complicações , Valvopatia Aórtica/complicações , Humanos , Masculino , Pessoa de Meia-Idade
16.
Interact Cardiovasc Thorac Surg ; 30(5): 679-684, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32236551

RESUMO

OBJECTIVES: Bentall procedure is the gold standard for aortic root pathologies when valve repair is not feasible. The development of durable bioprosthetic valves and improved vascular conduits allowed the implementation of bioprosthetic composite grafts; hereby, we performed a retrospective analysis of long-term follow-up of Bentall procedure using the Valsalva graft and the Perimount Magna Ease prosthesis. METHODS: From June 2000 to March 2019, 309 patients received an aortic root and valve replacement with a bioprosthetic composite graft. The mean age was 69 ± 6.9 years, and the majority were men (88%); most of them were affected by aortic stenosis (86%) and the mean aortic root diameter was 48.6 ± 5.5 mm. RESULTS: Freedom from cardiac death was 76.8% [confidence interval (CI) 32.5-94.0] at 16 years. Freedom from thromboembolism, haemorrhage, structural valve deterioration and infective endocarditis was 98.2% (CI 96.0-98.9), 95.2% (CI 87.1-98.2), 87.5% (CI 63.2-97.1) and 79.6% (CI 45.3-95.6) at 16 years, respectively. Freedom from reoperation was 74.7% (CI 41.9-90.6). CONCLUSIONS: These data indicate that, in experienced centres, the Bentall procedure is a safe and effective intervention. This is the first long-term follow-up that analyses the results after implantation of a composite graft made with the Perimount Magna Ease aortic valve and the Valsalva graft.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese Vascular/métodos , Implante de Prótese de Valva Cardíaca/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Reimplante , Estudos Retrospectivos , Fatores de Tempo
17.
Surg Technol Int ; 35: 197-201, 2020 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-32120449

RESUMO

INTRODUCTION: Progressive saphenous vein graft (SVG) failure remains a key limitation to the long-term success of coronary artery bypass grafting (CABG). SVG disease after the first year is dominated by intimal hyperplasia, which predisposes the SVG to thrombosis and accelerated atherosclerosis. The objective of this study was to review and summarize the latest experimental and clinical data on the use of mechanical external stents for vein grafts. METHODS: In January 2020, the PubMed database was searched using the terms "external stent", "CABG", "saphenous vein graft" and "intimal hyperplasia". The results were reviewed and only randomized experimental and clinical studies that analyzed the effect of external stenting on venous intimal hyperplasia were included in the analysis, together with studies that investigated the clinical benefit of external stenting. RESULTS: Eight experimental and four clinical trials met the search criteria. Controlled trials in different large animal models concluded that external stenting significantly reduced intimal hyperplasia 3-6 months post implantation, and reduced both thrombosis rates and the development of lumen irregularities. Data from randomized controlled trials with a follow-up period of 1-4.5 years supported the pre-clinical findings and demonstrated that external stents significantly reduced vein graft disease. CONCLUSION: Strong evidence indicates that supporting the vein with external stents is safe and leads to clear advantages at both the anatomical and cellular levels. With the further accumulation of consistent positive results, external stenting of SVG may become the standard of care in future CABG.


Assuntos
Ponte de Artéria Coronária/métodos , Oclusão de Enxerto Vascular/prevenção & controle , Veia Safena/transplante , Stents , Túnica Íntima/patologia , Animais , Aterosclerose/etiologia , Aterosclerose/prevenção & controle , Implante de Prótese Vascular/métodos , Oclusão de Enxerto Vascular/etiologia , Humanos , Hiperplasia/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Veia Safena/cirurgia , Trombose/etiologia , Trombose/prevenção & controle , Túnica Íntima/cirurgia , Grau de Desobstrução Vascular
18.
Interact Cardiovasc Thorac Surg ; 30(5): 666-670, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32031618

RESUMO

OBJECTIVES: The shape of the aortic annulus is still under debate. Recent findings suggest a possible gradual spectrum of circularity from tricuspid aortic valves (TAVs), to type 1 bicuspid aortic valves (BAVs) to type 0 BAVs. BAVs have been recently classified in a symmetrical (type A), asymmetrical (type B) or very asymmetrical (type C) phenotype according to the commissural orientation (CO) (160°-180°, 140°-159° and 120°-139°, respectively). The aim of this study is to verify in BAVs the correlation between the aortic annular shape and the CO of valve cusps and to suggest a new anatomical and geometric classification of BAVs based on CO and annular shape. METHODS: We retrospectively selected 191 consecutive patients who underwent both electrocardiography-gated computed tomography scan of the aortic root and transthoracic echocardiography between January 2016 and June 2019. The population was divided into 2 groups: 54 BAVs and 137 TAVs. We analysed the subgroup of BAV patients and divided them into group A, group B and group C depending on the CO. The shape of the aortic annulus was considered 'circular' or 'elliptic' according to the ellipticity index (EI).We studied the possible correlation between CO and annular shape in BAVs. We also analysed the subgroup of TAV patients studying their annular shape and EI. RESULTS: After univariate linear regression, BAV patients showed a significant correlation between the CO and the EI (R = -0, 445, R2 = 0, 198, P = 0.001). As the CO decreases, the EI increases and approaches an elliptical shape. After grouping BAVs according to the CO, a mean EI of 1.10 ± 0.07 was found in group A, 1.13 ± 0.08 in group B, 1.18 ± 0.07 in group C, P = 0.0097 indicating a gradual spectrum of ellipticity with the decrease of CO. TAVs subgroup showed a mean EI of 1.27 ± 0.09, suggesting that the more the CO is reduced in BAVs, the more the annulus probably tends towards the very elliptical shape of TAVs. CONCLUSIONS: This study shows a linear correlation between CO and annular shape in BAVs. In particular, the aortic annulus follows a continuous spectrum of ellipticity depending on the CO. These findings lay the groundwork for a new anatomical classification of BAVs based on CO and annular shape.


Assuntos
Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Ecocardiografia/métodos , Eletrocardiografia/métodos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Valva Tricúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
19.
Chin J Traumatol ; 23(1): 32-33, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31992479

RESUMO

Blunt traumatic aortic injury is the second leading cause of death after motor vehicle accidents. The most frequent localisation of aortic lesion is the isthmus, especially in those who survived the accident. Here we report a case of blunt traumatic aortic injury with unusual localisation and modality. A 31 years old man sustained a motorcycle accident, being run over by a car. Computed tomography scan showed an atypical ascending aorta lesion, confirmed by intraoperative finding. The patient underwent emergency ascending aorta replacement with Dacron tubular graft. The patient was discharged uneventfully on 35th postoperative day, after multiple maxillofacial surgeries for concomitant injuries.


Assuntos
Aorta/cirurgia , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Traumatismos Torácicos/complicações , Ferimentos não Penetrantes/complicações , Acidentes de Trânsito , Adulto , Dissecção Aórtica/diagnóstico por imagem , Aorta/diagnóstico por imagem , Aorta/patologia , Implante de Prótese Vascular , Emergências , Humanos , Masculino
20.
Surg Technol Int ; 35: 217-232, 2019 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-31476790

RESUMO

This is the third and final part of our update on the latest advances in cardiac valvular replacement. Part 1 was dedicated to cardiac valvular replacement, and Part 2 focused on transcatheter cardiac valvular treatment. This part concerns annuloplasty prostheses for valvular reconstructive surgery. The number of patients undergoing surgical heart valve repair has been increasing, particularly in high-volume centers. Annuloplasty is now considered the gold standard in mitral valve regurgitation repair secondary to degenerative, ischemic and idiopathic dilated cardiomyopathy disease. The techniques of mitral valve reconstruction have been well established, but controversies remain regarding the type of annuloplasty ring to be used. The available annuloplasty rings include rigid, flexible, complete, partial, and semi-rigid/flexible. The choice of annuloplasty ring has been the focus of extensive investigation and debate, but to date it still largely remains a matter of "surgeon's preference" rather than an evidence-based selection. Functional tricuspid regurgitation was traditionally treated by the classic De Vega annuloplasty, but has since evolved after the development of prosthetic tricuspid annuloplasty. Head-to-head comparisons have demonstrated superior long-term outcomes with device-based annuloplasty compared to suture-based surgery, but the type of ring to be used (flexible versus rigid) has recently been questioned, without reaching definitive conclusions. In contrast to mitral and tricuspid valve repair, aortic repair is more difficult with respect to specific valve features. Annuloplasty is considered to play a key role in controlling aortic regurgitation and preventing recurrence after valve repair. Various modifications of annuloplasty have been advocated (internal/external, with/without ring (suture), rigid/flexible ring). but none of them has become a de facto standard. This paper describes the various rings that are available to help orient surgeons and to serve as a reference for students.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Tricúspide , Humanos , Valva Mitral , Anuloplastia da Valva Mitral/métodos , Resultado do Tratamento , Valva Tricúspide , Insuficiência da Valva Tricúspide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA