RESUMO

The advent of 3D printing technologies has enabled the development of low-cost prosthetic underactuated hands, with cables working as tendons for flexion. Despite the particular relevance to human grasp, its conception in prosthetics is based on vague intuitions of the designers due to the lack of studies on its relevance to the functionality and performance of the device. In this work, some criteria for designers are provided regarding the carpometacarpal joint of the thumb in these devices. To this end, we studied four prosthetic hands of similar characteristics with the motion of abduction/adduction of the thumb resolved in three different ways: fixed at a certain abduction, coupled with the motion of flexion/extension, and actuated independently of the flexion/extension. The functionality and performance of the hands were assessed for the basic grasps using the Anthropomorphic Hand Assessment Protocol (AHAP) and a reduced version of the Southampton Hand Assessment Procedure (SHAP). As a general rule, it seems desirable that thumb adduction/abduction is performed independently of flexion/extension, although this adds one degree of control. If having this additional degree of control is beyond debate, coupled flexion/extension and adduction/abduction should be avoided in favour of the thumb having a fixed slight palmar abduction.

3.
Biomed Eng Online ; 10: 44, 2011 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-21635759

RESUMO

BACKGROUND: Finite element simulation has been used in last years for analysing the biomechanical performance of post-core restorations in endodontics, but results of these simulations have been interpreted in most of the works using von Mises stress criterion. However, the validity of this failure criterion for brittle materials, which are present in these restorations, is questionable. The objective of the paper is to analyse how finite element results for brittle materials of endodontic restorations should be interpreted to obtain correct conclusions about the possible failure in the restoration. METHODS: Different failure criteria (Von Mises, Rankine, Coulomb-Mohr, Modified Mohr and Christensen) and material strength data (diametral tensile strength and flexural strength) were considered in the study. Three finite element models (FEM) were developed to simulate an endodontic restoration and two typical material tests: diametral tensile test and flexural test. RESULTS: Results showed that the Christensen criterion predicts similar results as the Von Mises criterion for ductile components, while it predicts similar results to all other criteria for brittle components. The different criteria predict different failure points for the diametral tensile test, all of them under multi-axial stress states. All criteria except Von Mises predict failure for flexural test at the same point of the specimen, with this point under uniaxial tensile stress. CONCLUSIONS: From the results it is concluded that the Christensen criterion is recommended for FEM result interpretation in endodontic restorations and that the flexural test is recommended to estimate tensile strength instead of the diametral tensile test.


Assuntos
Falha de Restauração Dentária , Endodontia/métodos , Análise de Falha de Equipamento/métodos , Análise de Elementos Finitos , Fenômenos Mecânicos , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA