Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Int Heart J ; 64(6): 1025-1031, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38030289

RESUMO

The number of TV-PM implantations in elderly people is increasing. Although frailty syndrome is common in elderly patients, the relationship between the pre-procedural frailty status and clinical outcomes has not been fully elucidated in elderly TV-PM recipients.This study included 103 consecutive patients over 80 years old who were newly implanted with a TV-PM (age 85.7 ± 4.2, 41.7% male). We assessed the relationship between the clinical outcome and predictive factors, especially for the pre-procedural frailty status after the TV-PM implantation. The pre-procedural frailty status was retrospectively assessed from the medical records and classified on the basis of impairments in 3 domains (walking, cognition, and activities of daily living). The primary endpoint was defined as a heart failure admission.During the follow-up period (4.1 ± 2.3 years), 20 patients (19.4%) met the primary endpoint. Frailty syndrome was identified in 40 patients (38.8%). In univariate analysis, the LVEF (HR 0.97, 95% CI 0.96-1.00 P = 0.0492), an RV pacing burden over 40% (HR 1.58, 95% CI 1.00-2.54 P = 0.0473), and presence of a frailty status (HR 1.82, 95% CI 1.13-2.87 P = 0.0134) were found to be statistically significant predictors for the study endpoint. In multivariate analysis, having frailty syndrome was the only predictive factor for a heart failure admission (HR 1.83, 95% CI 1.12-2.93 P = 0.0157).The presence of frailty syndrome and incidence of clinical events were high and a pre-procedural frailty status assessment was key in determining the clinical outcomes in TV-PM recipients over 80 years old.


Assuntos
Fragilidade , Insuficiência Cardíaca , Marca-Passo Artificial , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Fragilidade/epidemiologia , Idoso Fragilizado , Estudos Retrospectivos , Atividades Cotidianas , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia
2.
Langmuir ; 39(37): 12999-13007, 2023 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-37658821

RESUMO

It is important to understand the mechanism of colloidal particle assembly near a substrate for development of drug delivery systems, micro-/nanorobots, batteries, heterogeneous catalysts, paints, and cosmetics. Understanding the mechanism is also important for crystallization of the colloidal particles and proteins. In this study, we calculated the physical adsorption of colloidal particles on a flat wall mainly using the integral equation theory, wherein small and large colloidal particles were employed. In the calculation system, like-charged electric double-layer potentials were used as pair potentials. In some cases, it was found that the small particles are more easily adsorbed. This result is unusual from the viewpoint of the Asakura-Oosawa theory, and we call it a "reversal phenomenon". Theoretical analysis revealed that the reversal phenomenon originates from the nonadditivities of the particle sizes. Using the knowledge obtained from this study, we invented a method to analyze the size nonadditivity hidden in model pair potentials. The method will be useful for confirmation of various simulation results regarding the adsorption and development of force fields for colloidal particles, proteins, and solutes.

3.
Kyobu Geka ; 75(6): 461-465, 2022 Jun.
Artigo em Japonês | MEDLINE | ID: mdl-35618693

RESUMO

There are only few reports on surgery for partial atrioventricular septal defect( pAVSD) in patients aged over 70 years. This report is about successful surgical correction of pAVSD in a 79-year-old women. Echocardiography showed left-sided atrioventricular valve regurgitation with cleft and ostium primum atrial septal defect, but without ventricular septal defect. Accordingly, she was diagnosed with pAVSD. Treatment plan included direct cleft closure, patch closure for the ostium primum atrial septal defect, and right atrioventricular annuloplasty. The postoperative course was uneventful. She was followed up without complications for four years. To the best of our knowledge, our patient is the oldest to undergo such surgical techniques in Japan to date.


Assuntos
Comunicação Interatrial , Comunicação Interventricular , Insuficiência da Valva Mitral , Idoso , Ecocardiografia , Feminino , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Humanos , Insuficiência da Valva Mitral/cirurgia
4.
Int Heart J ; 62(6): 1411-1413, 2021 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-34744145

RESUMO

A 27-year-old Caucasian male traveler with well-controlled asthma was admitted to our hospital because of severe heart failure (HF). He had a history of cocaine use. Transthoracic echocardiography (TTE) showed severe diffuse hypokinesis of the left ventricle (LV) and a large mobile thrombus in the LV. He was treated with diuretics, inotropes and anticoagulants which led to small improvements in the HF and LV thrombus, however, he needed to undergo left ventricular assist device (LVAD) implantation and surgical removal of a residual LV thrombus due to inotrope-dependency.It is necessary to consider the possibility of cocaine or illicit drug use in a young individual with cardiovascular disease or sudden death even in Japan where cocaine and drugs are prohibited by law, as recreational drug use has been increasing in many countries around the world.


Assuntos
Transtornos Relacionados ao Uso de Cocaína/complicações , Insuficiência Cardíaca/etiologia , Adulto , Ecocardiografia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Coração Auxiliar , Humanos , Masculino , Trombectomia , Trombose/diagnóstico por imagem
5.
Pacing Clin Electrophysiol ; 44(11): 1810-1816, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34554589

RESUMO

BACKGROUND: Transvenous implantable cardioverter defibrillator (TV-ICD) systems are commonly implanted in the left anterior chest because of an easier implantation and better defibrillation threshold. This study aimed to evaluate the safety and feasibility of left axillary implantations of TV-ICD systems. METHODS: We performed left axillary TV-ICD implantations and compared that to the major complication rate and operation time of the conventional TV-ICD implantation site (left anterior chest). The electrical parameter trends were also assessed in the left axilla group. RESULTS: Seventy-six consecutive patients were evaluated for the analysis. Thirty-one patients had their system implanted in the left axilla and the reasons for the implantations included 29 patients for cosmetic reasons and two for post-infection conditions. The operation time and major complication rate were similar between the two groups (left anterior chest vs. left axilla: 134±62.4 min vs. 114±33.5 min, p = .11, 1/45 patient, 2.2% [pocket hematoma] vs. 1/31 patient, 3.2% [lead dislodgement], p = .77). During the follow up period (4.9±2.3years), no lead interruptions were observed in either group. The electrical lead parameters at the time of the implantation and follow up were similar in the study group (R wave sensing 20.8±33.4 vs. 11.2±7.42 mv, p = .34; lead impedance 464±64.7 vs. 418±135ohm, p = .22; pacing threshold [at 0.4 ms] 1.0±0.76 vs. 1.21±0.93V, p = .49). CONCLUSION: TV-ICD implantations in the left axilla were performed safely without increasing the operation time as compared to the conventional ICD implantation site. ICD implantations in the left axilla are an alternative in those not suitable for implanting TV-ICDs in the conventional implantation site.


Assuntos
Axila/cirurgia , Desfibriladores Implantáveis , Segurança do Paciente , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos
6.
J Oleo Sci ; 70(9): 1247-1252, 2021 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-34373406

RESUMO

We characterized the adsorption and desorption of α-gel (α-form hydrated crystal) dispersions in aqueous media using a quartz crystal microbalance with dissipation monitoring (QCM-D) technique. The α-gel was formed from a mixture of N-[3-(dimethylamino)propyl]docosanamide (APA-22) L-lactic acid salt, 1-octadecanol (C18OH), and water. The solid substrate employed in this study as a model for hair was silica. The QCM-D measurements revealed that the α-gel dispersions yielded a rigid adsorption film on the negatively charged silica surface. The adsorption mass decreased with decreasing domain size (on the micrometer scale) of the α-gel dispersions. The adsorption film highly restricted the desorption of the α-gel from the silica surface even after rinsing with water. The adsorption film also exhibited excellent lubrication ability in aqueous media both before and after rinsing with water. We expect that the α-gel formed by APA-22 L-lactic acid is a potential ingredient for formulating an environment-friendly hair conditioner owing to its high adsorption, limited desorption, and excellent lubrication abilities on the solid surface.


Assuntos
Adsorção , Amidas/química , Ácido Láctico/química , Lubrificação , Técnicas de Microbalança de Cristal de Quartzo/métodos , Álcoois Graxos/química , Géis , Dióxido de Silício/química , Propriedades de Superfície , Água/química
7.
Heart Vessels ; 36(9): 1438-1444, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33740089

RESUMO

There is increased interest in creating high-power short duration (HPSD) ablation lesions in the field of atrial fibrillation (AF) radiofrequency ablation (RFA). We evaluated the lesion characteristics and collateral damage using two separate RFA protocols setting (HPSD: 50 W and 7 s vs control: 25 W and 30 s) in vitro model. Sixteen freshly killed porcine hearts were obtained, and the atrium and ventricle slabs were harvested for ablation. The each slabs were placed in a tissue bath with circulating 0.9% NaCl at maintained temperature 37 °C. RFA was performed with 4 mm tip irrigated force sensing catheter. All lesions were ablated under recording the electrical parameters using with Ensite Navx system (St. Jude Medical, St. Paul, Minnesota). After RFA, lesion characteristics were assessed for each lesion. Thirty-five lesions were made for each ablation protocol (total 70 lesions for analysis). Ablation parameters were similar between two groups (HPSD vs control; impedance drop (Ω): 34.2 ± 13.1 vs 36.1 ± 8.65 P = 0.49, contact force (g): 13.9 ± 4.37 vs 14.6 ± 5.09, P = 0.51, lesion size index: 4.8 ± 0.52 vs 4.73 ± 0.59, P = 0.62). Although the lesion volume was similar, the HPSD ablation creates wider but more shallower lesions compared to control group (HPSD vs control; lesion volume: 29.6 ± 18.1 mm3 vs 35.5 ± 17.1 mm3 P = 0.16, lesion diameter: 4.98 ± 0.91 mm vs 4.45 ± 0.74 mm P = 0.0095, lesion depth: 2.2 ± 0.76 mm vs 2.8 ± 1.56 mm P = 0.046). Of these, 38 lesions were assessed for adjacent tissue damage and adjacent tissue damages were more frequent seen in control group (HPSD vs control; 1/19 (5.26%) vs 6/19 (31.5%), P = 0.036). Effective lesions were made with HPSD, thereby reducing RFA procedure time. Although the lesion volume was similar between two groups, collateral damage was less seen in HPSD group attributed by lesion characteristics.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ablação por Radiofrequência , Animais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ventrículos do Coração , Suínos , Fatores de Tempo
8.
J Oleo Sci ; 69(12): 1561-1567, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33177284

RESUMO

We determine the effects of the α-gel (α-form hydrated crystal) domain size on the viscosity of water-diluted α-gels consisting of the N-[3-(dimethylamino)propyl]docosanamide (APA-22) L-lactic acid salt, 1-octadecanol (C18OH), and water. A decrease in the C18OH mole content results in increased domain size and viscosity of the water-diluted α-gel system. Additionally, when a sample is prepared by slow cooling and/or at low stirring speed, the domain size and viscosity of the water-diluted α-gel system increase. A similar increase in the domain size and viscosity of the α-gel system is observed for annealed samples. The observed change in the α-gel domain size is explained by the crystal growth theory.


Assuntos
Amidas/química , Géis/química , Ácido Láctico/química , Tamanho da Partícula , Tensoativos/química , Viscosidade , Água/química , Cristalização , Preparações para Cabelo
9.
J Oleo Sci ; 69(11): 1403-1409, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33055438

RESUMO

We studied the structures and properties of gel samples prepared by mixtures of N-[3-(dimethylamino)propyl]docosanamide (APA-22) acid salt (APA-22 L-lactic acid), 1-octadecanol (C18OH), and water. The gel samples prepared at the mole ratios [APA-22 L-lactic acid]:C18OH = 1:3, 1:4, and 1:5 yielded two phases; one being the α-gel (α-form hydrated crystal) phase, incorporating a significant quantity of water between lamellar bilayers, and the other being the excess water phase. The lamellar d-spacing remained practically unaltered at these mole ratios, thus maintaining the quantity of water incorporated between the lamellar bilayers relatively constant. Starting at 30°C, the gel samples transformed into a lamellar liquid crystal phase at high temperatures (85°C) and a ß-gel phase at low temperatures (5°C). Interestingly, following dilution by pure water, the viscosity of the gel samples decreased with increasing C18OH content. We expect that the viscosity change affects the performance of the gel samples as hair conditioners.


Assuntos
Amidas/química , Tensoativos/química , Cristalização , Géis , Preparações para Cabelo , Ácido Láctico/química , Bicamadas Lipídicas/química , Ácidos Esteáricos/química , Temperatura , Viscosidade , Água/química
10.
J Cardiol ; 75(6): 665-672, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31973979

RESUMO

BACKGROUND: Atrial remodeling associated with atrial fibrillation (AF) and sleep apnea is well known. Although sleep apnea is known to be associated with left atrial (LA) remodeling, its association with right atrial (RA) remodeling remains unclear. The study aimed to investigate the effect of sleep apnea on RA remodeling. METHODS: We enrolled 141 AF patients who had undergone ablation. Sleep study results were evaluated using a portable sleep apnea test device. RA and LA volumes were determined by computed tomography (CT), and atrial structural remodeling was defined as atrial volume on CT≥110mL according to previous reports. The atrial substrate was evaluated by three-dimensional electroanatomical mapping. RESULTS: After excluding 30 patients who received more than one catheter ablation or who could not receive enhanced CT, 111 patients were finally analyzed. The patients were classified into four groups according to the presence of RA and/or LA enlargement. Significant differences in AF type, N-terminal pro B-type natriuretic peptide (NT-proBNP) levels, and apnea-hypopnea index (AHI) were observed among the four groups. In univariate analysis, AHI values correlated with NT-proBNP levels (r=0.293, p=0.002), left ventricular ejection fraction (r=-0.198, p=0.044), LA volume (r=0.370, p<0.001), and RA volume (r=0.465, p<0.001). Multiple regression analysis showed that AHI was an independent predictor of increased RA volume, and LA was excluded as a multiple risk factor in AHI. AF type-adjusted AHI levels correlated with RA volume, and RA remodeling correlated with the percentage of LA low-voltage area. CONCLUSIONS: Sleep apnea was strongly associated with RA structural remodeling regardless of paroxysmal and non-paroxysmal AF, and this relationship was more prominent than the effect of LA. Our results suggest that the association between sleep apnea and RA dilatation should be given attention.


Assuntos
Fibrilação Atrial/etiologia , Remodelamento Atrial , Síndromes da Apneia do Sono/complicações , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Síndromes da Apneia do Sono/diagnóstico por imagem , Síndromes da Apneia do Sono/fisiopatologia , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda
13.
Biochemistry ; 55(46): 6355-6358, 2016 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-27933774

RESUMO

In photosystem II, redox potential Em of primary quinone QA shifts by approximately +150 mV upon inactivation of the Mn4CaO5 cluster. Although this phenomenon is important in photoprotection, the molecular mechanism of the positive Em(QA-/QA) shift remains unclear. Here, we investigated the effect of Mn depletion on the interaction of QA using light-induced ATR-FTIR spectroscopy. It was shown that Mn depletion hardly changed a QA-/QA FTIR difference spectrum, indicating that the H-bond interaction of QA and its immediate surroundings were virtually unchanged by Mn4CaO5 cluster inactivation. On the basis of this result, a possible mechanism of the Em(QA-/QA) shift is discussed.


Assuntos
Manganês/metabolismo , Complexo de Proteína do Fotossistema II/metabolismo , Quinonas/metabolismo , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Tilacoides/metabolismo , Transporte de Elétrons , Luz , Oxirredução/efeitos da radiação , Spinacia oleracea/metabolismo
14.
Circ J ; 80(4): 878-86, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26888267

RESUMO

BACKGROUND: To reduce myocardial damage caused by implantable cardioverter defibrillator (ICD) shock, the left axilla was studied as an alternative pulse generator implantation site, and compared with the traditional implantation site, the left anterior chest. METHODS AND RESULTS: Computer simulation was used to study the defibrillation conduction pattern and estimate the simulated defibrillation threshold (DFT) and myocardial damage when pulse generators were placed in the left axilla and left anterior chest, respectively; pulse generators were also newly implanted in the left axilla (n=30) and anterior chest (n=40) to compare the corresponding DFT. On simulation, when ICD generators were implanted in the left axilla, compared with the left anterior chest, the whole heart may be defibrillated with a lower defibrillation energy (left axilla 6.4 J vs. left anterior chest 12.0 J) and thus the proportion of cardiac myocardial damage may be reduced (2.1 vs. 4.2%). Clinically, ventricular fibrillation was successfully terminated with a defibrillation output ≤5 J in 86.7% (26/30) of the left axillary group, and in 27.5% (11/40) of the left anterior group (P<0.001). CONCLUSIONS: Clinically and theoretically, the left axilla was shown to be an improved ICD implantation site that may reduce DFT and lessen myocardial damage due to shock. Lower DFT also facilitates less myocardial damage, as a result of the lower shock required.


Assuntos
Axila , Simulação por Computador , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica , Modelos Cardiovasculares , Miocárdio/patologia , Fibrilação Ventricular , Adulto , Idoso , Idoso de 80 Anos ou mais , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Ventricular/patologia , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/terapia
15.
Circ J ; 80(1): 85-92, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26581624

RESUMO

BACKGROUND: Subcutaneous implantable cardiac defibrillator (S-ICD) systems have a lower invasiveness than traditional ICD systems, and expand the indications of ICD implantations. The S-ICD standard defibrillation shock output energy, however, is approximately 4 times that of the traditional ICD system. This raises concern about the efficacy of the defibrillation and myocardial injury. In this study, we investigated the defibrillation efficacy and myocardial injury with S-ICD systems based on computer simulations. METHODS AND RESULTS: First, computer simulations were performed based on the S-ICD system configurations proposed in a previous study. Furthermore, simulations were performed by placing the lead at the left or right parasternal margin and the pulse generator in the superior and inferior positions (0-10 cm) of the recommended site. The simulated defibrillation threshold (DFT) for the 4 S-ICD system configurations were 30.1, 41.6, 40.6, and 32.8 J, which were generally similar to the corresponding clinical results of 33.5, 40.4, 40.1, and 34.3 J. CONCLUSIONS: The simulated DFT were generally similar to their clinical counterparts. In the simulation, the S-ICD system had a higher DFT but relatively less severe myocardial injury compared with the traditional ICD system. Further, the lead at the right parasternal margin may correspond to a lower DFT and cause less myocardial injury.


Assuntos
Simulação por Computador , Desfibriladores Implantáveis/efeitos adversos , Traumatismos Cardíacos/fisiopatologia , Coração/fisiopatologia , Modelos Cardiovasculares , Traumatismos Cardíacos/etiologia , Humanos
16.
J Nat Prod ; 76(4): 769-73, 2013 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-23506561

RESUMO

Three new compounds, 1-3, together with 22 known compounds, were isolated from the fruits of Piper retrofractum. The structures of the new compounds were elucidated on the basis of spectroscopic data analysis and comparison with literature values. Compound 1 was found to enhance the neurite outgrowth of NGF-mediated PC12 cells at concentrations ranging from 0.1 to 10 µM.


Assuntos
Piper/química , Terpenos/isolamento & purificação , Terpenos/farmacologia , Animais , Frutas/química , Estrutura Molecular , Fatores de Crescimento Neural/efeitos dos fármacos , Neuritos/efeitos dos fármacos , Ratos , Terpenos/química
17.
Biochem Biophys Res Commun ; 297(2): 323-8, 2002 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-12237121

RESUMO

The IF3 gene was isolated by expression cloning from a cDNA library of mouse oocytes. This gene was revealed to have no homology to any known gene and its cDNA encodes a 202-amino acid protein that contains a signal-peptide sequence. Moreover, an IF3 isoform, IF3(2), was expressed in both liver and ovary. Its cDNA encoded a 92-amino acid protein contains a signal-peptide sequence, which may be an alternative splice and frameshift form of IF3. The mRNA of IF3s was expressed in oocytes, ovary, and liver. Moreover, the gene expression of IF3s was regulated in a development-dependent manner in preimplantation-embryo and liver. Both IF3(1) and IF3(2) isoforms induced the differentiation of 2T3 and ATDC5 cells to the osteogenic and chondrogenic phenotype, respectively, suggesting that IF3s may modulate the differentiation status. Our findings suggest that IF3 may be one of the secreted factors that regulate oogenesis and certain liver functions.


Assuntos
Diferenciação Celular/fisiologia , Fígado/metabolismo , Ovário/metabolismo , Proteínas/metabolismo , Sequência de Aminoácidos , Animais , Sequência de Bases , Linhagem Celular , Feminino , Biblioteca Gênica , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Dados de Sequência Molecular , Oócitos/química , Oócitos/metabolismo , Isoformas de Proteínas , Sinais Direcionadores de Proteínas , Proteínas/química , Proteínas/genética , Distribuição Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA