Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Pharmaceutics ; 15(6)2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37376106

RESUMO

Severe HSV-1 infection can cause blindness due to tissue damage from severe inflammation. Due to the high risk of graft failure in HSV-1-infected individuals, cornea transplantation to restore vision is often contraindicated. We tested the capacity for cell-free biosynthetic implants made from recombinant human collagen type III and 2-methacryloyloxyethyl phosphorylcholine (RHCIII-MPC) to suppress inflammation and promote tissue regeneration in the damaged corneas. To block viral reactivation, we incorporated silica dioxide nanoparticles releasing KR12, the small bioactive core fragment of LL37, an innate cationic host defense peptide produced by corneal cells. KR12 is more reactive and smaller than LL37, so more KR12 molecules can be incorporated into nanoparticles for delivery. Unlike LL37, which was cytotoxic, KR12 was cell-friendly and showed little cytotoxicity at doses that blocked HSV-1 activity in vitro, instead enabling rapid wound closure in cultures of human epithelial cells. Composite implants released KR12 for up to 3 weeks in vitro. The implant was also tested in vivo on HSV-1-infected rabbit corneas where it was grafted by anterior lamellar keratoplasty. Adding KR12 to RHCIII-MPC did not reduce HSV-1 viral loads or the inflammation resulting in neovascularization. Nevertheless, the composite implants reduced viral spread sufficiently to allow stable corneal epithelium, stroma, and nerve regeneration over a 6-month observation period.

2.
Cornea ; 42(5): 615-623, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36455096

RESUMO

PURPOSE: The purpose of this study was to assess the potential of new lipoglycopeptides as novel topical therapies for improved treatment of recalcitrant ocular infections. We evaluated the in vitro antimicrobial activity of oritavancin, dalbavancin, and telavancin compared with vancomycin (VAN) against a large collection of ocular staphylococcal isolates and their cytotoxicity on human corneal epithelial cells (HCECs). METHODS: Antimicrobial susceptibility testing was performed by broth microdilution against 223 Staphylococcus spp. clinical isolates. Time-kill kinetics were determined for methicillin-resistant strains of Staphylococcus aureus (MRSA) (n = 2) and Staphylococcus epidermidis (MRSE) (n = 1). In vitro cytotoxicity assays were performed with AlamarBlue and live/dead staining on HCECs. RESULTS: All new lipoglycopeptides showed strong in vitro potency against ocular staphylococci, including multidrug-resistant MRSA strains, with dalbavancin showing a slightly higher potency overall [minimum inhibitory concentration (MIC) 90 0.06 µg/mL] compared with telavancin and oritavancin (MIC 90 0.12 µg/mL), whereas VAN had the lowest potency (MIC 90 2 µg/mL). Oritavancin exerted rapid bactericidal activity within 1 h for MRSA and 2 h for MRSE. All other drugs were bactericidal within 24 h. At a concentration commonly used for topical preparations (25 mg/mL), cytotoxicity was observed for VAN after 5 min of incubation, whereas reduction in HCEC viability was not seen for telavancin and was less affected by oritavancin and dalbavancin. Cytotoxicity at 25 mg/mL was seen for all drugs at 30 and 60 min but was significantly reduced or undetected for lower concentrations. CONCLUSIONS: Our study demonstrates that new lipoglycopeptides have substantially better in vitro antimicrobial activity against ocular staphylococcal isolates compared with VAN, with a similar or improved toxicity profile on HCECs.


Assuntos
Epitélio Corneano , Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Humanos , Vancomicina/toxicidade , Vancomicina/uso terapêutico , Lipoglicopeptídeos/toxicidade , Lipoglicopeptídeos/uso terapêutico , Staphylococcus , Antibacterianos/toxicidade , Antibacterianos/uso terapêutico , Infecções Estafilocócicas/tratamento farmacológico , Testes de Sensibilidade Microbiana
3.
Sci Rep ; 12(1): 9108, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35650270

RESUMO

Development of an artificial cornea can potentially fulfil the demand of donor corneas for transplantation as the number of donors is far less than needed to treat corneal blindness. Collagen-based artificial corneas stand out as a regenerative option, having promising clinical outcomes. Collagen crosslinked with chemical crosslinkers which modify the parent functional groups of collagen. However, crosslinkers are usually cytotoxic, so crosslinkers need to be removed from implants completely before application in humans. In addition, crosslinked products are mechanically weak and susceptible to enzymatic degradation. We developed a crosslinker free supramolecular gelation strategy using pyrene conjugated dipeptide amphiphile (PyKC) consisting of lysine and cysteine; in which collagen molecules are intertwined inside the PyKC network without any functional group modification of the collagen. The newly developed collagen implants (Coll-PyKC) are optically transparent and can effectively block UV light, are mechanically and enzymatically stable, and can be sutured. The Coll-PyKC implants support the growth and function of all corneal cells, trigger anti-inflammatory differentiation while suppressing the pro-inflammatory differentiation of human monocytes. Coll-PyKC implants can restrict human adenovirus propagation. Therefore, this crosslinker-free strategy can be used for the repair, healing, and regeneration of the cornea, and potentially other damaged organs of the body.


Assuntos
Colágeno , Córnea , Colágeno/metabolismo , Córnea/metabolismo , Humanos , Próteses e Implantes , Regeneração , Raios Ultravioleta
4.
Pharmaceutics ; 13(6)2021 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-34204956

RESUMO

Collagen scaffolds, one of the most used biomaterials in corneal tissue engineering, are frequently crosslinked to improve mechanical properties, enzyme tolerance, and thermal stability. Crosslinkers such as 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) are compatible with tissues but provide low crosslinking density and reduced mechanical properties. Conversely, crosslinkers such as glutaraldehyde (GTA) can generate mechanically more robust scaffolds; however, they can also induce greater toxicity. Herein, we evaluated the effectivity of double-crosslinking with both EDC and GTA together with the capability of sodium metabisulfite (SM) and sodium borohydride (SB) to neutralize the toxicity and restore biocompatibility after crosslinking. The EDC-crosslinked collagen scaffolds were treated with different concentrations of GTA. To neutralize the free unreacted aldehyde groups, scaffolds were treated with SM or SB. The chemistry involved in these reactions together with the mechanical and functional properties of the collagen scaffolds was evaluated. The viability of the cells grown on the scaffolds was studied using different corneal cell types. The effect of each type of scaffold treatment on human monocyte differentiation was evaluated. One-way ANOVA was used for statistical analysis. The addition of GTA as a double-crosslinking agent significantly improved the mechanical properties and enzymatic stability of the EDC crosslinked collagen scaffold. GTA decreased cell biocompatibility but this effect was reversed by treatment with SB or SM. These agents did not affect the mechanical properties, enzymatic stability, or transparency of the double-crosslinked scaffold. Contact of monocytes with the different scaffolds did not trigger their differentiation into activated macrophages. Our results demonstrate that GTA improves the mechanical properties of EDC crosslinked scaffolds in a dose-dependent manner, and that subsequent treatment with SB or SM partially restores biocompatibility. This novel manufacturing approach would facilitate the translation of collagen-based artificial corneas to the clinical setting.

5.
Bioact Mater ; 6(11): 3947-3961, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33937594

RESUMO

Gelatin based adhesives have been used in the last decades in different biomedical applications due to the excellent biocompatibility, easy processability, transparency, non-toxicity, and reasonable mechanical properties to mimic the extracellular matrix (ECM). Gelatin adhesives can be easily tuned to gain different viscoelastic and mechanical properties that facilitate its ocular application. We herein grafted glycidyl methacrylate on the gelatin backbone with a simple chemical modification of the precursor, utilizing epoxide ring-opening reactions and visible light-crosslinking. This chemical modification allows the obtaining of an elastic protein-based hydrogel (GELGYM) with excellent biomimetic properties, approaching those of the native tissue. GELGYM can be modulated to be stretched up to 4 times its initial length and withstand high tensile stresses up to 1.95 MPa with compressive strains as high as 80% compared to Gelatin-methacryloyl (GeIMA), the most studied derivative of gelatin used as a bioadhesive. GELGYM is also highly biocompatible and supports cellular adhesion, proliferation, and migration in both 2 and 3-dimensional cell-cultures. These characteristics along with its super adhesion to biological tissues such as cornea, aorta, heart, muscle, kidney, liver, and spleen suggest widespread applications of this hydrogel in many biomedical areas such as transplantation, tissue adhesive, wound dressing, bioprinting, and drug and cell delivery.

6.
Commun Biol ; 4(1): 608, 2021 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-34021240

RESUMO

The long-term survival of biomaterial implants is often hampered by surgery-induced inflammation that can lead to graft failure. Considering that most corneas receiving grafts are either pathological or inflamed before implantation, the risk of rejection is heightened. Here, we show that bioengineered, fully synthetic, and robust corneal implants can be manufactured from a collagen analog (collagen-like peptide-polyethylene glycol hybrid, CLP-PEG) and inflammation-suppressing polymeric 2-methacryloyloxyethyl phosphorylcholine (MPC) when stabilized with the triazine-based crosslinker 4-(4,6-Dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium chloride. The resulting CLP-PEG-MPC implants led to reduced corneal swelling, haze, and neovascularization in comparison to CLP-PEG only implants when grafted into a mini-pig cornea alkali burn model of inflammation over 12 months. Implants incorporating MPC allowed for faster nerve regeneration and recovery of corneal sensation. CLP-PEG-MPC implants appear to be at a more advanced stage of regeneration than the CLP-PEG only implants, as evidenced by the presence of higher amounts of cornea-specific type V collagen, and a corresponding decrease in the presence of extracellular vesicles and exosomes in the corneal stroma, in keeping with the amounts present in healthy, unoperated corneas.


Assuntos
Álcalis/toxicidade , Queimaduras Químicas/complicações , Colágeno/farmacologia , Córnea/citologia , Hidrogéis/administração & dosagem , Inflamação/prevenção & controle , Fosforilcolina/química , Animais , Materiais Biocompatíveis/química , Queimaduras Químicas/patologia , Colágeno/química , Humanos , Hidrogéis/química , Inflamação/etiologia , Inflamação/patologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Suínos , Porco Miniatura
7.
Ocul Surf ; 20: 176-184, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33667673

RESUMO

PURPOSE: To evaluate the effects of electron-beam (E-beam) irradiation on the human cornea and the potential for E-beam sterilization of Boston keratoprosthesis (BK) devices when pre-assembled with a donor cornea prior to sterilization. METHODS: Human donor corneas and corneas pre-assembled in BK devices were immersed in recombinant human serum albumin (rHSA) media and E-beam irradiated at 25 kGy. Mechanical (tensile strength and modulus, and compression modulus), chemical, optical, structural, and degradation properties of the corneal tissue after irradiation and after 6 months of preservation were evaluated. RESULTS: The mechanical evaluation showed that E-beam irradiation enhanced the tensile and compression moduli of human donor corneas, with no impact on their tensile strength. By chemical and mechanical analysis, E-beam irradiation caused a minor degree of crosslinking between collagen fibrils. No ultrastructural changes due to E-beam irradiation were observed. E-beam irradiation slightly increased the stability of the cornea against collagenase-induced degradation and had no impact on glucose diffusion. The optical evaluation showed transparency of the cornea was maintained. E-beam irradiated corneal tissues and BK-cornea pre-assembled devices were stable for 6 months after room-temperature preservation. CONCLUSIONS: E-beam irradiation generated no detrimental effects on the corneal tissues or BK-cornea pre-assembled devices and improved native properties of the corneal tissue, enabling prolonged preservation at room temperature. The pre-assembly of BK in a donor cornea, followed by E-beam irradiation, offers the potential for an off-the-shelf, ready to implant keratoprosthesis device.


Assuntos
Córnea , Doenças da Córnea , Elétrons , Humanos , Próteses e Implantes , Esterilização
8.
Indian J Hematol Blood Transfus ; 37(1): 162-166, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33707851

RESUMO

Imatinib, the first Tyrosine Kinase Inhibitor (TKI) used for the treatment of chronic myeloid leukaemia (CML) has revolutionized the management by inhibiting BCR-ABL tyrosine kinase. According to earlier reports there are concerns regarding the adverse effect of imatinib on haemostasis by causing platelet dysfunction. Here we studied platelet function using platelet aggregometry, in 19 CML chronic phase (CML-CP) patients on imatinib therapy, in complete haematologic response (CHR). The median duration of imatinib therapy before performing the test was 154 days. This study reveals that there are large inter-individual variations in platelet functions among imatinib treated patients and different levels of variability have been seen for different agonists. Most common aggregation abnormality (< 50% aggregation) was seen with low dose collagen (1 µg/ml) in 31.57% patients. Despite in-vitro platelet aggregation defects, none of the patients showed any bleeding symptoms. This enigma can possibly be explained by the fact that platelet specific agonists, epinephrine and collagen act in synergy for platelet aggregation compared against individual low dose agonists, supported by ex-vivo experiments in normal healthy control group (n = 5) (p value < 0.0004 for epinephrine, p value < 0.0001 for collagen). This experiment was also confirmed in a CML-CP patient. In future, more studies are needed to find out the exact mechanism of this inhibition.

9.
Acta Biomater ; 127: 169-179, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33785451

RESUMO

Inadequate supplies of donor corneas have evoked an escalating interest in corneal xenotransplantation. However, innate immune responses contribute significantly to the mechanism of xenograft rejection. We hypothesized that complement component C5 and TLR co-receptor CD14 inhibition would inhibit porcine cornea induced innate immune responses. Therefore, we measured cytokine release in human blood, induced by three forms of corneal xenografts with or without inhibitors. Native porcine cornea (NPC) induced interleukins (IL-1ß, IL-2, IL-6, IL-8, IL-1ra), chemokines (MCP-1, MIP-1α, MIP-1ß) and other cytokines (TNF, G-CSF, INF-γ, FGF-basic). Decellularized (DPC) and gamma-irradiated cornea (g-DPC) elevated the release of those cytokines. C5-blockade by eculizumab inhibited all the cytokines except G-CSF when induced by NPC. However, C5-blockade failed to reduce DPC and g-DPC induced cytokines. Blockade of CD14 inhibited DPC-induced cytokines except for IL-8, MCP-1, MIP-1α, and G-CSF, while it inhibited all of them when induced by g-DPC. Combined blockade of C5 and CD14 inhibited the maximum number of cytokines regardless of the xenograft type. Finally, by using the TLR4 specific inhibitor Eritoran, we showed that TLR4 activation was the basis for the CD14 effect. Thus, blockade of C5, when combined with TLR4 inhibition, may have therapeutic potential in pig-to-human corneal xenotransplantation. STATEMENT OF SIGNIFICANCE: Bio-engineered corneal xenografts are on the verge of becoming a viable alternative to allogenic human-donor-cornea, but the host's innate immune response is still a critical barrier for graft acceptance. By overruling this barrier, limited graft availability would no longer be an issue for treating corneal diseases. We showed that the xenograft induced inflammation is initiated by the complement system and toll-like receptor activation. Intriguingly, the inflammatory response was efficiently blocked by simultaneously targeting bottleneck molecules in the complement system (C5) and the TLR co-receptor CD14 with pharmaceutical inhibitors. We postulate that a combination of C5 and CD14 inhibition could have a great therapeutic potential to overcome the immunologic barrier in pig-to-human corneal xenotransplantation.


Assuntos
Complemento C5/antagonistas & inibidores , Transplante de Córnea/efeitos adversos , Xenoenxertos , Inflamação/etiologia , Receptores de Lipopolissacarídeos , Animais , Córnea , Citocinas , Humanos , Suínos , Transplante Heterólogo
10.
Macromol Biosci ; 21(4): e2000379, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33624923

RESUMO

Electron beam (E-beam) irradiation is an attractive and efficient method for sterilizing clinically implantable medical devices made of natural and/or synthetic materials such as poly(methyl methacrylate) (PMMA). As ionizing irradiation can affect the physicochemical properties of PMMA, understanding the consequences of E-beam sterilization on the intrinsic properties of PMMA is vital for clinical implementation. A detailed assessment of the chemical, optical, mechanical, morphological, and biological properties of medical-grade PMMA after E-beam sterilization at 25 and 50 kiloGray (kGy) is reported. Fourier transform infrared spectroscopy, thermogravimetric analysis, and differential scanning calorimetry studies indicate that E-beam irradiation has minimal effect on the chemical properties of the PMMA at these doses. While 25 kGy irradiation does not alter the mechanical and optical properties of the PMMA, 50 kGy reduces the flexural strength and transparency by 10% and 2%, respectively. Atomic force microscopy demonstrates that E-beam irradiation reduces the surface roughness of PMMA in a dose dependent manner. Live-Dead, AlamarBlue, immunocytochemistry, and complement activation studies show that E-beam irradiation up to 50 kGy has no adverse effect on the biocompatibility of the PMMA. These findings suggest that E-beam irradiation at 25 kGy may be a safe and efficient alternative for PMMA sterilization.


Assuntos
Polimetil Metacrilato/química , Esterilização/instrumentação , Materiais Biocompatíveis , Varredura Diferencial de Calorimetria , Ativação do Complemento , Córnea/metabolismo , Elétrons , Fibroblastos/metabolismo , Raios gama , Humanos , Microscopia de Força Atômica , Espectroscopia de Infravermelho com Transformada de Fourier , Esterilização/métodos , Estresse Mecânico , Propriedades de Superfície , Temperatura , Termogravimetria , Água
11.
Transl Vis Sci Technol ; 9(13): 41, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33442495

RESUMO

Purpose: To evaluate titanium (Ti) sputtering of the poly(methyl methacrylate) (PMMA) stem of the Boston Keratoprosthesis (BK) as a method to enhance interfacial adhesion between the PMMA and the recipient corneal tissue. Methods: PMMA specimens were plasma treated with Ar/O2 and coated with Ti using a DC magnetron sputtering instrument. The topography and hydrophilicity of the surfaces were characterized using atomic force microscopy and a water contact angle instrument, respectively. Scratch hardness and adhesion of the Ti film were measured using a mechanical tester. Biocompatibility assessments were performed using cultured human corneal fibroblasts and whole blood ex vivo. The optical quality of the Ti sputtered BK was evaluated using a custom-made optical bench. Results: By contact angle studies, the Ti coating improved PMMA hydrophilicity to match that of medical-grade Ti (Ti-6Al-4V-ELI). Ti sputtering of contact surfaces resulted in a plate-like morphology with increased surface roughness, without impacting the transparency of the BK optical component. Scratch testing indicated that the mechanical behavior of the Ti coating was similar to that of casted Ti, and the coating was stable in pull-off adhesion testing. Sputtered Ti film was highly biocompatible based on tests of cell viability, adhesion, proliferation, differentiation, collagen deposition, and keratocan expression, the properties of which exceeded those of uncoated PMMA and did not induce increased complement activation. Conclusions: Titanium coating of the BK stem generated a mechanically and biologically favorable interface, which may help to enhance corneal stromal adhesion and biocompatibility. Translational Relevance: Improving the biocompatibility of the BK PMMA stem may improve long-term outcomes of implantation.


Assuntos
Polimetil Metacrilato , Titânio , Córnea , Humanos , Próteses e Implantes , Propriedades de Superfície
12.
Acta Biomater ; 96: 330-344, 2019 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-31284096

RESUMO

To address the shortcomings associated with corneal transplants, substantial efforts have been focused on developing new modalities such as xenotransplantion. Xenogeneic corneas are anatomically and biomechanically similar to the human cornea, yet their applications require prior decellularization to remove the antigenic components to avoid rejection. In the context of bringing decellularized corneas into clinical use, sterilization is a crucial step that determines the success of the transplantation. Well-standardized sterilization methods, such as gamma irradiation (GI), have been applied to decellularized porcine corneas (DPC) to avoid graft-associated infections in human recipients. However, little is known about the effect of GI on decellularized corneal xenografts. Here, we evaluated the radiation effect on the ultrastructure, optical, mechanical and biological properties of DPC. Transmission electron microscopy revealed that gamma irradiated decellularized porcine cornea (G-DPC) preserved its structural integrity. Moreover, the radiation did not reduce the optical properties of the tissue. Neither DPC nor G-DPC led to further activation of complement system compared to native porcine cornea when exposed to plasma. Although, DPC were mechanically comparable to the native tissue, GI increased the mechanical strength, tissue hydrophobicity and resistance to enzymatic degradation. Despite these changes, human corneal epithelial, stromal, endothelial and hybrid neuroblastoma cells grew and differentiated on DPC and G-DPC. Thus, GI may achieve effective tissue sterilization without affecting critical properties that are essential for corneal transplant survival.


Assuntos
Córnea/química , Transplante de Córnea , Desinfecção , Raios gama , Alicerces Teciduais/química , Animais , Córnea/patologia , Xenoenxertos , Humanos , Suínos
13.
Ocul Surf ; 16(3): 322-330, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29627599

RESUMO

PURPOSE: To make the Boston keratoprosthesis (B-KPro), together with its carrier corneal graft, more easily procured, transported and stored, as well as less expensive, easier for the surgeon to implant and safer for the patient, it is proposed that the B-KPro-graft combination be pre-assembled by an expert technician, followed by sterilization with gamma ray irradiation (GI) allowing long-term storage at room temperature. For this to be possible, it must be shown that the B-KPro itself (not only the graft) remains unharmed by the irradiation. METHODS: Polymethyl methacrylate (PMMA) discs and B-KPros were submitted to either ethylene oxide sterilization or different doses of GI. Cell biocompatibility, mechanical strength and optical quality were evaluated. The feasibility of assembling the B-KPro to a corneal graft, and gamma-radiate afterwards, was also assessed. RESULTS: There were no differences in cell biocompatibility between the samples. The optical evaluation showed high levels of transparency for all the groups. The absorbance of ultraviolet was higher for the groups treated with GI. The mechanical evaluation by nanoindentation showed no alterations of the PMMA discs after GI. The flexure test revealed a similar mechanical behavior. Technically, pre-assembly and GI of the B-KPro revealed no problems. CONCLUSIONS: Sterilization of B-KPro using GI has no detrimental influence on the device. The pre-assembly of B-KPro to a donor cornea, followed by gamma sterilization, emerges as an efficient and safe procedure.


Assuntos
Órgãos Artificiais , Doenças da Córnea/cirurgia , Raios gama , Próteses e Implantes , Esterilização/métodos , Materiais Biocompatíveis , Humanos , Teste de Materiais , Preservação de Órgãos/métodos , Polimetil Metacrilato
14.
Nanoscale ; 8(39): 17213-17222, 2016 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-27714161

RESUMO

To cope with the rapid evolution of the tissue engineering field, it is now essential to incorporate the use of on-site responsive scaffolds. Therefore, it is of utmost importance to find new 'Intelligent' biomaterials that can respond to the physicochemical changes in the microenvironment. In this present report, we have developed biocompatible stimuli responsive polyaniline-multiwalled carbon nanotube/poly(N-isopropylacrylamide), (PANI-MWCNT/PNIPAm) composite nanofiber networks and demonstrated the physiological temperature coordinated cell grafting phenomenon on its surface. The composite nanofibers were prepared by a two-step process initiated with an assisted in situ polymerization followed by electrospinning. To obtain a smooth surface in individual nanofibers with the thinnest diameter, the component ratios and electrospinning conditions were optimized. The temperature-gated rearrangements of the molecular structure are characterized by FTIR spectroscopy with simultaneous macromolecular architecture changes reflected on the surface morphology, average diameter and pore size as determined by scanning electron microscopy. The stimuli responsiveness of the nanofibers has first been optimized with computational modeling of temperature sensitive components (coil-like and globular conformations) to tune the mechanism for temperature dependent interaction during in situ scaffolding with the cell membrane. The nanofiber networks show excellent biocompatibility, tested with fibroblasts and also show excellent sensitivity to inflammation to combat loco-regional acidosis that delay the wound healing process by an in vitro model that has been developed for testing the proposed responsiveness of the composite nanofiber networks. Cellular adhesion and detachment are regulated through physiological temperature and show normal proliferation of the grafted cells on the composite nanofibers. Thus, we report for the first time, the development of physiological temperature gated inflammation-sensitive smart biomaterials for advanced tissue regeneration and regenerative medicine.


Assuntos
Materiais Biocompatíveis , Nanofibras , Medicina Regenerativa , Engenharia Tecidual , Alicerces Teciduais , Animais , Linhagem Celular , Proliferação de Células , Fibroblastos/citologia , Células Endoteliais da Veia Umbilical Humana/citologia , Humanos , Inflamação , Camundongos , Nanocompostos
15.
Methods Mol Biol ; 1014: 45-52, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23690003

RESUMO

Human corneal transplantation to date suffers from the shortage of good-quality donor tissue, and in some conditions, allografting is contraindicated. A range of artificial replacements to donor allograft corneas have been developed. These range from keratoprostheses (KPro) that replace basic corneal functions of light transmission and protection to regenerative medicine strategies for regenerating one or more layers of the human cornea. This chapter reviews the advances made in developing artificial corneas or more accurately, artificial alternatives to donor allograft corneas for ocular application.


Assuntos
Córnea/patologia , Doenças da Córnea/terapia , Animais , Colágeno , Transplante de Córnea/métodos , Humanos , Implantes Experimentais , Organoides/transplante , Próteses e Implantes , Medicina Regenerativa , Engenharia Tecidual , Alicerces Teciduais
16.
Methods Mol Biol ; 1014: 157-64, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23690011

RESUMO

Human recombinant collagen can be cross-linked with a variety of chemical cross-linking agents. Cross-linking methods can be tuned to confer collagen-based scaffolds with specific physical properties, improved antigenicity and thermal stability without impeding the ability of the material to integrate into the surrounding tissue and to promote regeneration. Here, we describe a method to cross-link human recombinant collagen using a water soluble carbodiimide. Carbodiimides are referred to as zero-length cross-linking agents as they are not incorporated into the final cross-link and thus pose minimal risk with respect to cytotoxicity. The resulting collagen-based scaffold possesses properties comparable to that of the human cornea and is thus suitable for use as a corneal substitute.


Assuntos
Carbodi-Imidas/química , Colágeno/química , Engenharia Tecidual , Humanos , Organoides/transplante , Próteses e Implantes , Proteínas Recombinantes/química , Alicerces Teciduais
17.
J Funct Biomater ; 4(3): 162-77, 2013 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-24956085

RESUMO

A bi-functional epoxy-based cross-linker, 1,4-Butanediol diglycidyl ether (BDDGE), was investigated in the fabrication of collagen based corneal substitutes. Two synthetic strategies were explored in the preparation of the cross-linked collagen scaffolds. The lysine residues of Type 1 porcine collagen were directly cross-linked using l,4-Butanediol diglycidyl ether (BDDGE) under basic conditions at pH 11. Alternatively, under conventional methodology, using both BDDGE and 1-Ethyl-3-(3-dimethyl aminopropyl) carbodiimide (EDC)/N-hydroxysuccinimide (NHS) as cross-linkers, hydrogels were fabricated under acidic conditions. In this latter strategy, Cu(BF4)2·XH2O was used to catalyze the formation of secondary amine bonds. To date, we have demonstrated that both methods of chemical cross-linking improved the elasticity and tensile strength of the collagen implants. Differential scanning calorimetry and biocompatibility studies indicate comparable, and in some cases, enhanced properties compared to that of the EDC/NHS controls. In vitro studies showed that human corneal epithelial cells and neuronal progenitor cell lines proliferated on these hydrogels. In addition, improvement of cell proliferation on the surfaces of the materials was observed when neurite promoting laminin epitope, IKVAV, and adhesion peptide, YIGSR, were incorporated. However, the elasticity decreased with peptide incorporation and will require further optimization. Nevertheless, we have shown that epoxy cross-linkers should be further explored in the fabrication of collagen-based hydrogels, as alternatives to or in conjunction with carbodiimide cross-linkers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA