Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 214
Filtrar
1.
Eur J Radiol ; 177: 111542, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38861906

RESUMO

INTRODUCTION: Visualization of scoliosis typically requires ionizing radiation (radiography and CT) to visualize bony anatomy. MRI is often additionally performed to screen for neural axis abnormalities. We propose a 14-minutes radiation-free scoliosis-specific MRI protocol, which combines MRI and MRI-based synthetic CT images to visualize soft and osseous structures in one examination. We assess the ability of the protocol to visualize landmarks needed to detect 3D patho-anatomical changes, screen for neural axis abnormalities, and perform surgical planning and navigation. METHODS: 18 adult volunteers were scanned on 1.5 T MR-scanner using 3D T2-weighted and synthetic CT sequences. A predefined checklist of relevant landmarks was used for the parameter assessment by three readers. Parameters included Cobb angles, rotation, torsion, segmental height, area and centroids of Nucleus Pulposus and Intervertebral Disc. Precision, reliability and agreement between the readers measurements were evaluated. RESULTS: 91 % of Likert-based questions scored ≥ 4, indicating moderate to high confidence. Precision of 3D dot positioning was 1.0 mm. Precision of angle measurement was 0.6° (ICC 0.98). Precision of vertebral and IVD height measurements was 0.4 mm (ICC 0.99). Precision of area measurement for NP was 8 mm2 (ICC 0.55) and for IVD 18 mm2 (ICC 0.62) for IVD. Precision of centroid measurement for NP was 1.3 mm (ICC 0.88-0.92) and for IVD 1.1 mm (ICC 0.88-91). CONCLUSIONS: The proposed MRI protocol with synthetic CT reconstructions, has high precision, reliability and agreement between the readers for multiple scoliosis-specific measurements. It can be used to study scoliosis etiopathogenesis and to assess 3D spinal morphology.

2.
Egypt Heart J ; 76(1): 53, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38696068

RESUMO

BACKGROUND: Four-dimensional flow magnetic resonance imaging (MRI) enables blood flow visualization. The absence of left atrial vortex flow (LAVF) has been implicated in the development of thrombus formation and arrhythmias. However, the clinical relevance of this phenomenon in patients with congenital heart disease (CHD) remains unclear. This study aimed to unravel the relationship of LAVF with left atrial functions in patients with CHD. RESULTS: Twenty-five participants who underwent cardiac MRI examinations were included (8 postoperative patients with CHD aged 17-41 years and 17 volunteers aged 21-31 years). All participants were in sinus rhythm. Four-dimensional flow MRI (velocity encoding 100 cm/s) assessed the presence of LAVF, and its relationship with left atrial function determined by transthoracic echocardiography was explored. LAVF was detected in 16 patients. Upon classification of the participants based on the presence or absence of LAVF, 94% of participants in the LAVF group were volunteers, while 78% of those in the without LAVF group were postoperative patients. Participants without LAVF had a significantly lower left atrial ejection fraction (61% vs. 70%, p = 0.019), reservoir (32% vs. 47%, p = 0.006), and conduit (22% vs. 36%, p = 0.002) function than those with LAVF. CONCLUSIONS: LAVF occurred during the late phase of ventricular systole, and left atrial reservoir function may have contributed to its occurrence. Many postoperative patients with CHD experienced a loss of LAVF. LAVF may indicate early left atrial dysfunction resulting from left atrial remodeling.

3.
Chem Commun (Camb) ; 60(29): 3946-3949, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38497901

RESUMO

We synthesized and evaluated Pam3CSK4-conjugated receptor binding domain (RBD)/deglycosylated RBD as potential anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccine candidates. Our investigation revealed the critical importance of limiting the number of introduced Pam3CSK4 molecules to the RBD in order to preserve its antigenicity. We also confirmed the harmonious integration of the adjuvant-conjugation strategy with the glycan-shield removal strategy.


Assuntos
COVID-19 , Vacinas Virais , Humanos , SARS-CoV-2 , Receptor 1 Toll-Like , Anticorpos Antivirais , COVID-19/prevenção & controle , Ligantes , Adjuvantes Imunológicos/farmacologia
4.
Heart Vessels ; 39(2): 117-122, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37740077

RESUMO

Left atrial (LA) stiffness is one of the most important factors involved in LA remodeling. LA stiffness has rarely been studied postoperatively in patients with congenital heart diseases (CHDs). This study aimed to evaluate LA stiffness in CHD patients postoperatively. Seventy-five patients (CHDs, 67; controls, 8; age range, 10-41 years) who underwent cardiac catheterization at our institution were included in this study. From the pulmonary artery wedge pressure waveform obtained during cardiac catheterization, the pressure range between the v wave and x trough was determined, and this value was divided by the LA reservoir strain obtained by echocardiography to calculate LA stiffness, as previously reported. LA stiffness was significantly higher in postoperative CHD patients than in controls (0.28 ± 0.17 vs. 0.13 ± 0.03, p = 0.001). Nineteen of 52 (37%) patients in their teens, 8 of 11 (73%) patients in their 20 s, and 1 of 4 (25%) patients aged > 30 years had elevated LA stiffness values. In particular, all patients with an LA reservoir strain < 20% had elevated LA stiffness. In postoperative CHD patients, LA stiffness was frequently elevated from a young age. CHD patients with elevated LA stiffness should be cautious of possible LA dysfunction in the future.


Assuntos
Apêndice Atrial , Cardiopatias Congênitas , Adolescente , Humanos , Criança , Adulto Jovem , Adulto , Átrios do Coração/diagnóstico por imagem , Ecocardiografia , Cateterismo Cardíaco , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/cirurgia
5.
Brain Commun ; 5(6): fcad296, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38090279

RESUMO

The clinical presentation of corticobasal degeneration is diverse, while the background pathology of corticobasal syndrome is also heterogeneous. Therefore, predicting the pathological background of corticobasal syndrome is extremely difficult. Herein, we investigated the clinical findings and course in patients with pathologically, genetically and biochemically verified corticobasal degeneration and corticobasal syndrome with background pathology to determine findings suggestive of background disorder. Thirty-two patients were identified as having corticobasal degeneration. The median intervals from the initial symptoms to the onset of key milestones were as follows: gait disturbance, 0.0 year; behavioural changes, 1.0 year; falls, 2.0 years; cognitive impairment, 2.0 years; speech impairment, 2.5 years; supranuclear gaze palsy, 3.0 years; urinary incontinence, 3.0 years; and dysphagia, 5.0 years. The median survival time was 7.0 years; 50% of corticobasal degeneration was diagnosed as corticobasal degeneration/corticobasal syndrome at the final presentation. Background pathologies of corticobasal syndrome (n = 48) included corticobasal degeneration (33.3%), progressive supranuclear palsy (29.2%) and Alzheimer's disease (12.5%). The common course of corticobasal syndrome was initial gait disturbance and early fall. In addition, corticobasal degeneration-corticobasal syndrome manifested behavioural change (2.5 years) and cognitive impairment (3.0 years), as the patient with progressive supranuclear palsy-corticobasal syndrome developed speech impairment (1.0 years) and supranuclear gaze palsy (6.0 years). The Alzheimer's disease-corticobasal syndrome patients showed cognitive impairment (1.0 years). The frequency of frozen gait at onset was higher in the corticobasal degeneration-corticobasal syndrome group than in the progressive supranuclear palsy-corticobasal syndrome group [P = 0.005, odds ratio (95% confidence interval): 31.67 (1.46-685.34)]. Dysarthria at presentation was higher in progressive supranuclear palsy-corticobasal syndrome than in corticobasal degeneration-corticobasal syndrome [P = 0.047, 6.75 (1.16-39.20)]. Pyramidal sign at presentation and personality change during the entire course were higher in Alzheimer's disease-corticobasal syndrome than in progressive supranuclear palsy-corticobasal syndrome [P = 0.011, 27.44 (1.25-601.61), and P = 0.013, 40.00 (1.98-807.14), respectively]. In corticobasal syndrome, decision tree analysis revealed that 'freezing at onset' or 'no dysarthria at presentation and age at onset under 66 years in the case without freezing at onset' predicted corticobasal degeneration pathology with a sensitivity of 81.3% and specificity of 84.4%. 'Dysarthria at presentation and age at onset over 61 years' suggested progressive supranuclear palsy pathology, and 'pyramidal sign at presentation and personality change during the entire course' implied Alzheimer's disease pathology. In conclusion, frozen gait at onset, dysarthria, personality change and pyramidal signs may be useful clinical signs for predicting background pathologies in corticobasal syndrome.

6.
Front Bioeng Biotechnol ; 11: 1244291, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37731762

RESUMO

The generation of subject-specific finite element models of the spine is generally a time-consuming process based on computed tomography (CT) images, where scanning exposes subjects to harmful radiation. In this study, a method is presented for the automatic generation of spine finite element models using images from a single magnetic resonance (MR) sequence. The thoracic and lumbar spine of eight adult volunteers was imaged using a 3D multi-echo-gradient-echo sagittal MR sequence. A deep-learning method was used to generate synthetic CT images from the MR images. A pre-trained deep-learning network was used for the automatic segmentation of vertebrae from the synthetic CT images. Another deep-learning network was trained for the automatic segmentation of intervertebral discs from the MR images. The automatic segmentations were validated against manual segmentations for two subjects, one with scoliosis, and another with a spine implant. A template mesh of the spine was registered to the segmentations in three steps using a Bayesian coherent point drift algorithm. First, rigid registration was applied on the complete spine. Second, non-rigid registration was used for the individual discs and vertebrae. Third, the complete spine was non-rigidly registered to the individually registered discs and vertebrae. Comparison of the automatic and manual segmentations led to dice-scores of 0.93-0.96 for all vertebrae and discs. The lowest dice-score was in the disc at the height of the implant where artifacts led to under-segmentation. The mean distance between the morphed meshes and the segmentations was below 1 mm. In conclusion, the presented method can be used to automatically generate accurate subject-specific spine models.

8.
Front Bioeng Biotechnol ; 11: 1244954, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37691908

RESUMO

Anterior cruciate ligament (ACL) rupture is a very common knee joint injury. Torn ACLs are currently reconstructed using tendon autografts. However, half of the patients develop osteoarthritis (OA) within 10 to 14 years postoperatively. Proposedly, this is caused by altered knee kine(ma)tics originating from changes in graft mechanical properties during the in vivo remodeling response. Therefore, the main aim was to use subject-specific finite element knee models and investigate the influence of decreasing graft stiffness and/or increasing graft laxity on knee kine(ma)tics and cartilage loading. In this research, 4 subject-specific knee geometries were used, and the material properties of the ACL were altered to either match currently used grafts or mimic in vivo graft remodeling, i.e., decreasing graft stiffness and/or increasing graft laxity. The results confirm that the in vivo graft remodeling process increases the knee range of motion, up to >300 percent, and relocates the cartilage contact pressures, up to 4.3 mm. The effect of remodeling-induced graft mechanical properties on knee stability exceeded that of graft mechanical properties at the time of surgery. This indicates that altered mechanical properties of ACL grafts, caused by in vivo remodeling, can initiate the early onset of osteoarthritis, as observed in many patients clinically.

9.
J Biomed Mater Res A ; 111(12): 1903-1915, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37539663

RESUMO

Low back pain is the leading cause of disability worldwide, but current therapeutic interventions are palliative or surgical in nature. Loss of notochordal cells (NCs) and degradation of the healthy matrix in the nucleus pulposus (NP), the central tissue of intervertebral discs (IVDs), has been associated with onset of degenerative disc changes. Recently, we established a protocol for decellularization of notochordal cell derived matrix (NCM) and found that it can provide regenerative cues to nucleus pulposus cells of the IVD. Here, we combined the biologically regenerative properties of decellularized NCM with the mechanical tunability of a poly(ethylene glycol) hydrogel to additionally address biomechanics in the degenerate IVD. We further introduced a hydrolysable PEG-diurethane crosslinker for slow degradation of the gels in vivo. The resulting hydrogels were tunable over a broad range of stiffness's (0.2 to 4.5 kPa), matching that of NC-rich and -poor NP tissues, respectively. Gels formed within 30 min, giving ample time for handling, and remained shear-thinning post-polymerization. Gels also slowly released dNCM over 28 days as measured by GAG effusion. Viability of encapsulated bone marrow stromal cells after extrusion through a needle remained high. Although encapsulated NCs stayed viable over two weeks, their metabolic activity decreased, and their phenotype was lost in physiological medium conditions in vitro. Overall, the obtained gels hold promise for application in degenerated IVDs but require further tuning for combined use with NCs.


Assuntos
Degeneração do Disco Intervertebral , Disco Intervertebral , Núcleo Pulposo , Humanos , Hidrogéis/farmacologia , Hidrogéis/metabolismo , Degeneração do Disco Intervertebral/terapia , Núcleo Pulposo/metabolismo , Células Cultivadas
10.
Clin Biomech (Bristol, Avon) ; 108: 106071, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37597385

RESUMO

BACKGROUND: Proximal junctional failure is a common complication attributed to the rigidity of long pedicle screw fixation constructs used for surgical correction of adult spinal deformity. Semi-rigid junctional fixation achieves a gradual transition in range of motion at the ends of spinal instrumentation, which could lead to reduced junctional stresses, and ultimately reduce the incidence of proximal junctional failure. This study investigates the biomechanical effect of different semi-rigid junctional fixation techniques in a T8-L3 finite element spine segment model. METHODS: First, degeneration of the intervertebral disc was successfully implemented by altering the height. Second, transverse process hooks, one- and two-level clamped tapes, and one- and two-level knotted tapes instrumented proximally to three-level pedicle screw fixation were validated against ex vivo range of motion data of a previous study. Finally, the posterior ligament complex forces and nucleus pulposus stresses were quantified. FINDINGS: Simulated range of motions demonstrated the fidelity of the general model and modelling of semi-rigid junctional fixation techniques. All semi-rigid junctional fixation techniques reduced the posterior ligament complex forces at the junctional zone compared to pedicle screw fixation. Transverse process hooks and knotted tapes reduced nucleus pulposus stresses, whereas clamped tapes increased nucleus pulposus stresses at the junctional zone. INTERPRETATION: The relationship between the range of motion transition and the reductions in posterior ligament complex and nucleus pulposus stresses was complex and dependent on the fixation techniques. Clinical trials are required to compare the effectiveness of semi-rigid junctional fixation techniques in terms of reducing proximal junctional failure incidence rates.


Assuntos
Parafusos Pediculares , Procedimentos de Cirurgia Plástica , Adulto , Humanos , Análise de Elementos Finitos , Movimento (Física) , Amplitude de Movimento Articular
11.
Cureus ; 15(6): e39845, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37397670

RESUMO

Background Central venous pressure (CVP) is one of the most important hemodynamic parameters in patients with congenital heart disease (CHD). In adults, it is well-known that liver fibrosis markers reflect CVP, but this is not well-understood in children. We investigated the liver fibrosis markers in pediatric CHD patients and their ability to predict CVP. Methods We studied 160 patients who underwent cardiac catheterization in our hospital between January 2017 and December 2020. The levels of the fibrotic markers, including type IV collagen 7s, procollagen type III peptide, and hyaluronic acid, were measured. Results Procollagen type III peptide was markedly elevated in infants younger than one year of age. From one to 15 years of age, it was slightly lower than in the infant group, with a peak at around 10 years of age. In the age group of 16 years and older, most of its values were generally high. Type IV collagen 7s and hyaluronic acid levels were high in infants, with no significant differences at later ages. Procollagen type III peptide and hyaluronic acid showed no significant correlation with CVP in any of the age groups, whereas type IV collagen 7s significantly correlated with CVP in the age group above one year old. Conclusions We found that elevated liver fibrosis markers, particularly type IV collagen 7s, correlated with central venous pressure in CHD patients older than one year. Measurement of liver fibrosis markers may allow the early detection of changes in CVP and liver function in patients with CHD.

12.
Front Immunol ; 14: 1173728, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37492571

RESUMO

Immune checkpoint inhibitors highlight the importance of anticancer immunity. However, their clinical utility and safety are limited by the low response rates and adverse effects. We focused on progesterone (P4), a hormone produced by the placenta during pregnancy, because it has multiple biological activities related to anticancer and immune regulation effects. P4 has a reversible immune regulatory function distinct from that of the stress hormone cortisol, which may drive irreversible immune suppression that promotes T cell exhaustion and apoptosis in patients with cancer. Because the anticancer effect of P4 is induced at higher than physiological concentrations, we aimed to develop a new anticancer drug by encapsulating P4 in liposomes. In this study, we prepared liposome-encapsulated anti-programmed death ligand 1 (PD-L1) antibody-conjugated P4 (Lipo-anti-PD-L1-P4) and evaluated the effects on the growth of MDA-MB-231 cells, a PD-L1-expressing triple-negative breast cancer cell line, in vitro and in NOG-hIL-4-Tg mice transplanted with human peripheral blood mononuclear cells (humanized mice). Lipo-anti-PD-L1-P4 at physiological concentrations reduced T cell exhaustion and proliferation of MDA-MB-231 in vitro. Humanized mice bearing MDA-MB-231 cells expressing PD-L1 showed suppressed tumor growth and peripheral tissue inflammation. The proportion of B cells and CD4+ T cells decreased, whereas the proportion of CD8+ T cells increased in Lipo-anti-PD-L1-P4-administrated mice spleens and tumor-infiltrated lymphocytes. Our results suggested that Lipo-anti-PD-L1-P4 establishes a systemic anticancer immune environment with minimal toxicity. Thus, the use of P4 as an anticancer drug may represent a new strategy for cancer treatment.


Assuntos
Lipossomos , Neoplasias , Humanos , Animais , Camundongos , Progesterona , Leucócitos Mononucleares
13.
Adv Healthc Mater ; 12(27): e2301205, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37405830

RESUMO

Human in vitro bone remodeling models, using osteoclast-osteoblast cocultures, can facilitate the investigation of human bone remodeling while reducing the need for animal experiments. Although current in vitro osteoclast-osteoblast cocultures have improved the understanding of bone remodeling, it is still unknown which culture conditions support both cell types. Therefore, in vitro bone remodeling models can benefit from a thorough evaluation of the impact of culture variables on bone turnover outcomes, with the aim to reach balanced osteoclast and osteoblast activity, mimicking healthy bone remodeling. Using a resolution III fractional factorial design, the main effects of commonly used culture variables on bone turnover markers in an in vitro human bone remodeling model are identified. This model is able to capture physiological quantitative resorption-formation coupling along all conditions. Culture conditions of two runs show promising results: conditions of one run can be used as a high bone turnover system and conditions of another run as a self-regulating system as the addition of osteoclastic and osteogenic differentiation factors is not required for remodeling. The results generated with this in vitro model allow for better translation between in vitro studies and in vivo studies, toward improved preclinical bone remodeling drug development.


Assuntos
Remodelação Óssea , Osteogênese , Animais , Humanos , Remodelação Óssea/fisiologia , Osteoclastos/metabolismo , Osteoblastos , Técnicas de Cocultura , Diferenciação Celular
14.
J Am Chem Soc ; 145(29): 15838-15847, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-37344812

RESUMO

We report a promising cancer vaccine candidate comprising antigen/adjuvant-displaying enveloped viral replica as a novel vaccine platform. The artificial viral capsid, which consists of a self-assembled ß-annulus peptide conjugated with an HER2-derived antigenic CH401 peptide, was enveloped within a lipid bilayer containing the lipidic adjuvant α-GalCer. The use of an artificial viral capsid as a scaffold enabled precise control of its size to ∼100 nm, which is generally considered to be optimal for delivery to lymph nodes. The encapsulation of the anionically charged capsid by a cationic lipid bilayer dramatically improved its stability and converted its surface charge to cationic, enhancing its uptake by dendritic cells. The developed CH401/α-GalCer-displaying enveloped viral replica exhibited remarkable antibody-production activity. This study represents a pioneering example of precise vaccine design through bottom-up construction and opens new avenues for the development of effective vaccines.


Assuntos
Vacinas Anticâncer , Neoplasias , Bicamadas Lipídicas , Antígenos , Adjuvantes Imunológicos , Peptídeos
15.
JOR Spine ; 6(2): e1251, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37361332

RESUMO

Background Context: Cervical disc replacement (CDR) aims to restore motion of the treated level to reduce the risk of adjacent segment disease (ASD) compared with spinal fusion. However, first-generation articulating devices are unable to mimic the complex deformation kinematics of a natural disc. Thus, a biomimetic artificial intervertebral CDR (bioAID), containing a hydroxyethylmethacrylate (HEMA)-sodium methacrylate (NaMA) hydrogel core representing the nucleus pulposus, an ultra-high-molecular-weight-polyethylene fiber jacket as annulus fibrosus, and titanium endplates with pins for primary mechanical fixation, was developed. Purpose: To assess the initial biomechanical effect of the bioAID on the kinematic behavior of the canine spine, an ex vivo biomechanical study in 6-degrees-of-freedom was performed. Study Design: A canine cadaveric biomechanical study. Methods: Six cadaveric canine specimens (C3-C6) were tested in flexion-extension (FE), lateral bending (LB) axial rotation (AR) using a spine tester in three conditions: intact, after C4-C5 disc replacement with bioAID, and after C4-C5 interbody fusion. A hybrid protocol was used where first the intact spines were subjected to a pure moment of ±1 Nm, whereafter the treated spines were subjected to the full range of motion (ROM) of the intact condition. 3D segmental motions at all levels were measured while recording the reaction torsion. Biomechanical parameters studied included ROM, neutral zone (NZ), and intradiscal pressure (IDP) at the adjacent cranial level (C3-C4). Results: The bioAID retained the sigmoid shape of the moment-rotation curves with a NZ similar to the intact condition in LB and FE. Additionally, the normalized ROMs at the bioAID-treated level were statistically equivalent to intact during FE and AR while slightly decreased in LB. At the two adjacent levels, ROMs showed similar values for the intact compared to the bioAID for FE and AR and an increase in LB. In contrast, levels adjacent to the fused segment showed an increased motion in FE and LB as compensation for the loss of motion at the treated level. The IDP at the adjacent C3-C4 level after implantation of bioAID was close to intact values. After fusion, increased IDP was found compared with intact but did not reach statistical significance. Conclusion: This study indicates that the bioAID can mimic the kinematic behavior of the replaced intervertebral disc and preserves that for the adjacent levels better than fusion. As a result, CDR using the novel bioAID is a promising alternative treatment for replacing severely degenerated intervertebral discs.

16.
Biotechnol Bioeng ; 120(7): 2013-2026, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37148472

RESUMO

The transition in the field of bone tissue engineering from bone regeneration to in vitro models has come with the challenge of recreating a dense and anisotropic bone-like extracellular matrix (ECM). Although the mechanism by which bone ECM gains its structure is not fully understood, mechanical loading and curvature have been identified as potential contributors. Here, guided by computational simulations, we evaluated cell and bone-like tissue growth and organization in a concave channel with and without directional fluid flow stimulation. Human mesenchymal stromal cells were seeded on donut-shaped silk fibroin scaffolds and osteogenically stimulated for 42 days statically or in a flow perfusion bioreactor. After 14, 28, and 42 days, constructs were investigated for cell and tissue growth and organization. As a result, directional fluid flow was able to improve organic tissue growth but not organization. Cells tended to orient in the tangential direction of the channel, possibly attributed to its curvature. Based on our results, we suggest that organic ECM production but not anisotropy can be stimulated through the application of fluid flow. With this study, an initial attempt in three-dimensions was made to improve the resemblance of in vitro produced bone-like ECM to the physiological bone ECM.


Assuntos
Osso e Ossos , Células-Tronco Mesenquimais , Humanos , Engenharia Tecidual/métodos , Osteogênese , Regeneração Óssea , Alicerces Teciduais , Células Cultivadas , Diferenciação Celular
17.
J Biomed Mater Res A ; 111(9): 1423-1440, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37021718

RESUMO

In tissue engineering, cells are grown often on scaffolds and subjected to chemical/mechanical stimuli. Most such cultures still use fetal bovine serum (FBS) despite its known disadvantages including ethical concerns, safety issues, and variability in composition, which greatly influences the experimental outcomes. To overcome the disadvantages of using FBS, chemically defined serum substitute medium needs to be developed. Development of such medium depends on cell type and application-which makes it impossible to define one universal serum substitute medium for all cells in any application. Here, we developed a serum substitute medium for bone tissue engineering (BTE) in a step-by-step process. Essential components were added to the medium while human bone marrow mesenchymal stromal cells (hBMSCs, osteoblast progenitor cells) were cultured in two-dimensional and three-dimensional substrates. In a 3-week culture, the developed serum substitute medium worked equally well as FBS containing medium in term of cell attachment to the substrate, cell survival, osteoblast differentiation, and deposition of extracellular matrix. In the next step, the use of serum substitute medium was evaluated when culturing cells under mechanical loading in the form of shear stress. The outcomes showed that the application of shear stress is essential to improve extracellular matrix formation while using serum substitute medium. The developed serum substitute medium could pave the way in replacing FBS for BTE studies eliminating the use of controversial FBS and providing a better-defined chemical environment for BTE studies.


Assuntos
Células-Tronco Mesenquimais , Engenharia Tecidual , Humanos , Engenharia Tecidual/métodos , Proliferação de Células , Soro/química , Soro/metabolismo , Osso e Ossos , Diferenciação Celular , Células Cultivadas
18.
Angew Chem Int Ed Engl ; 62(30): e202304779, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-37083035

RESUMO

Antibody dynamics on membranes, such as endocytosis and clustering, are vital in determining antibody functions. In this study, we demonstrated that glycan conjugation can modulate antibody dynamics through the glycan-lectin interaction to regulate its potency. The anti-HER2 antibody, an anti-breast-cancer antibody, was conjugated with galactose-containing N-glycan, and its internalization was suppressed by interaction with galectin-3, leading to enhanced complement-dependent cytotoxic (CDC) activity. This glycan-antibody conjugate is proposed as a new approach to modulate antibody activity and may provide an alternative strategy for redeveloping antibody drugs that do not exhibit sufficient activity.


Assuntos
Antineoplásicos , Imunoconjugados , Lectinas , Polissacarídeos
19.
J Mech Behav Biomed Mater ; 142: 105808, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37087956

RESUMO

A novel biomimetic artificial intervertebral disc (bioAID) replacement implant has been developed containing a swelling hydrogel representing the nucleus pulposus, a tensile strong fiber jacket as annulus fibrosus and titanium endplates with pins to primarily secure the device between the vertebral bodies. In this study, the design safety of this novel implant was evaluated based on several biomechanical parameters, namely compressive strength, shear-compressive strength, risk of subsidence and device expulsion as well as identifying the diurnal creep-recovery characteristics of the device. The bioAID remained intact up to 1 kN under static axial compression and only 0.4 mm of translation was observed under a compressive shear load of 20 N. No subsidence was observed after 0.5 million cycles of sinusoidal compressive loading between 50 and 225 N. After applying 400 N in antero-posterior direction under 100 N axial compressive preload, approximately 2 mm displacement was found, being within the range of displacements reported for other commercially available cervical disc replacement devices. The diurnal creep recovery behavior of the bioAID closely resembled what has been reported for natural intervertebral discs in literature. Overall, these results indicate that the current design can withstand (shear-compression loads and is able to remain fixed in a mechanical design resembling the vertebral bodies. Moreover, it is one of the first implants that can closely mimic the poroelastic and viscoelastic behavior of natural disc under a diurnal loading pattern.


Assuntos
Anel Fibroso , Disco Intervertebral , Biomimética , Vértebras Lombares , Disco Intervertebral/cirurgia , Vértebras Cervicais/cirurgia , Força Compressiva , Estresse Mecânico , Fenômenos Biomecânicos , Suporte de Carga
20.
JOR Spine ; 6(1): e1240, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36994465

RESUMO

Background: Nucleus pulposus (NP) cell density is orchestrated by an interplay between nutrient supply and metabolite accumulation. Physiological loading is essential for tissue homeostasis. However, dynamic loading is also believed to increase metabolic activity and could thereby interfere with cell density regulation and regenerative strategies. The aim of this study was to determine whether dynamic loading could reduce the NP cell density by interacting with its energy metabolism. Methods: Bovine NP explants were cultured in a novel NP bioreactor with and without dynamic loading in milieus mimicking the pathophysiological or physiological NP environment. The extracellular content was evaluated biochemically and by Alcian Blue staining. Metabolic activity was determined by measuring glucose and lactate in tissue and medium supernatants. A lactate-dehydrogenase staining was performed to determine the viable cell density (VCD) in the peripheral and core regions of the NP. Results: The histological appearance and tissue composition of NP explants did not change in any of the groups. Glucose levels in the tissue reached critical values for cell survival (≤0.5 mM) in all groups. Lactate released into the medium was increased in the dynamically loaded compared to the unloaded groups. While the VCD was unchanged on Day 2 in all regions, it was significantly reduced in the dynamically loaded groups on Day 7 (p ≤ 0.01) in the NP core, which led to a gradient formation of VCD in the group with degenerated NP milieu and dynamic loading (p ≤ 0.05). Conclusion: It was demonstrated that dynamic loading in a nutrient deprived environment similar to that during IVD degeneration can increase cell metabolism to the extent that it was associated with changes in cell viability leading to a new equilibrium in the NP core. This should be considered for cell injections and therapies that lead to cell proliferation for treatment of IVD degeneration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA